메뉴 건너뛰기




Volumn 6, Issue 3, 2004, Pages 130-141

A three-year follow-up report of a comparative study of ITI Dental Implants® and Brånemark System® implants in the treatment of the partially edentulous maxilla

Author keywords

Br nemark System implants; Comparative study; ITI dental implants; Marginal bone change; Randomized study

Indexed keywords

CLINDAMYCIN; GOLD; PENICILLIN V;

EID: 9644257307     PISSN: 15230899     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1708-8208.2004.tb00213.x     Document Type: Article
Times cited : (112)

References (30)
  • 1
    • 0031989768 scopus 로고    scopus 로고
    • Biological factors contributing to failures of osseointegrated oral implants (1). Success criteria and epidemiology
    • Esposito M, Hirsch J-M, Lekholm U, Thomsen P. Biological factors contributing to failures of osseointegrated oral implants (1). Success criteria and epidemiology. Eur J Oral Sci 1998; 106:527-551.
    • (1998) Eur J Oral Sci , vol.106 , pp. 527-551
    • Esposito, M.1    Hirsch, J.-M.2    Lekholm, U.3    Thomsen, P.4
  • 2
    • 18944386736 scopus 로고    scopus 로고
    • Interventions for replacing missing teeth: Different types of dental implants
    • Chichester, UK: John Wiley & Sons, Ltd. Cochrane Library number: CD003815
    • Esposito M, Worthington HV, Thomsen P, Coulthard P. Interventions for replacing missing teeth: different types of dental implants (Cochrane Review). In: The Cochrane Library, Issue 3, 2004. Chichester, UK: John Wiley & Sons, Ltd. Cochrane Library number: CD003815.
    • (2004) The Cochrane Library , Issue.3
    • Esposito, M.1    Worthington, H.V.2    Thomsen, P.3    Coulthard, P.4
  • 3
    • 0037928812 scopus 로고    scopus 로고
    • A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years
    • Berglundh T, Persson L, Klinge B. A systematic review of the incidence of biological and technical complications in implant dentistry reported in prospective longitudinal studies of at least 5 years. J Clin Periodontol 2002; 29(Suppl 3):197-212.
    • (2002) J Clin Periodontol , vol.29 , Issue.3 SUPPL. , pp. 197-212
    • Berglundh, T.1    Persson, L.2    Klinge, B.3
  • 4
    • 0024673831 scopus 로고
    • A comparative study of results with various endosseous implant systems
    • D'Hoedt B, Schulte W. A comparative study of results with various endosseous implant systems. Int J Oral Maxillofac Implants 1989; 4:95-105.
    • (1989) Int J Oral Maxillofac Implants , vol.4 , pp. 95-105
    • D'Hoedt, B.1    Schulte, W.2
  • 6
    • 0026836584 scopus 로고
    • A comparative study of the clinical efficacy of Screw Vent implants versus Brånemark fixtures installed in a periodontic clinic
    • De Bruyn H, Collaert B, Lindén U, Flygare L. A comparative study of the clinical efficacy of Screw Vent implants versus Brånemark fixtures installed in a periodontic clinic. Clin Oral Implants Res 1992; 3:32-41.
    • (1992) Clin Oral Implants Res , vol.3 , pp. 32-41
    • De Bruyn, H.1    Collaert, B.2    Lindén, U.3    Flygare, L.4
  • 7
    • 0027566663 scopus 로고
    • Overdentures: An alternative implant methodology for edentulous patients
    • Mericske-Stern R, Zarb G. Overdentures: an alternative implant methodology for edentulous patients. Int J Prosthodont 1993; 6:203-208.
    • (1993) Int J Prosthodont , vol.6 , pp. 203-208
    • Mericske-Stern, R.1    Zarb, G.2
  • 9
    • 0031116313 scopus 로고    scopus 로고
    • A comparative prospective clinical study of two single tooth implants: A preliminary report of 102 implants
    • Kemppainen P, Eskola S, Ylipaavaniemi P. A comparative prospective clinical study of two single tooth implants: a preliminary report of 102 implants. J Prosthet Dent 1997; 77:382-387.
    • (1997) J Prosthet Dent , vol.77 , pp. 382-387
    • Kemppainen, P.1    Eskola, S.2    Ylipaavaniemi, P.3
  • 10
    • 0032229337 scopus 로고    scopus 로고
    • Mandibular overdentures supported by two Brånemark, IMZ or ITI implants. A prospective comparative preliminary study: One year results
    • Batenburg R, Meijer H, Raghoebar G, van Oort R, Boering G. Mandibular overdentures supported by two Brånemark, IMZ or ITI implants. A prospective comparative preliminary study: one year results. Clin Oral Implants Res 1998; 9:374-383.
    • (1998) Clin Oral Implants Res , vol.9 , pp. 374-383
    • Batenburg, R.1    Meijer, H.2    Raghoebar, G.3    Van Oort, R.4    Boering, G.5
  • 12
    • 0034208063 scopus 로고    scopus 로고
    • Prospective split-mouth comparative study of two screw-shaped self-tapping pure titanium implant systems
    • Van Steenberghe D, De Mmars G, Quirynen M, Jacobs R, Naert I.A. Prospective split-mouth comparative study of two screw-shaped self-tapping pure titanium implant systems. Clin Oral Implants Res 2000; 11:202-209.
    • (2000) Clin Oral Implants Res , vol.11 , pp. 202-209
    • Van Steenberghe, D.1    De Mmars, G.2    Quirynen, M.3    Jacobs, R.4    Naert, I.A.5
  • 13
    • 0035491604 scopus 로고    scopus 로고
    • Brånemark System and ITI Dental Implant System for treatment of mandibular edentulism. A comparative randomized study: 3-Year follow-up
    • Moberg LE, Kondell PA, Sagulin GB, Bolin A, Heimdahl A, Gynther GW. Brånemark System and ITI Dental Implant System for treatment of mandibular edentulism. A comparative randomized study: 3-year follow-up. Clin Oral Implants Res 2001; 12:450-461.
    • (2001) Clin Oral Implants Res , vol.12 , pp. 450-461
    • Moberg, L.E.1    Kondell, P.A.2    Sagulin, G.B.3    Bolin, A.4    Heimdahl, A.5    Gynther, G.W.6
  • 14
    • 0036985577 scopus 로고    scopus 로고
    • Nonsubmerged and submerged implants in the treatment of the partially edentulous maxilla
    • Åstrand P, Engquist B, Anzén B, et al. Nonsubmerged and submerged implants in the treatment of the partially edentulous maxilla. Clin Implant Dent Relat Res 2002; 4:115-127.
    • (2002) Clin Implant Dent Relat Res , vol.4 , pp. 115-127
    • Åstrand, P.1    Engquist, B.2    Anzén, B.3
  • 18
    • 0022726532 scopus 로고
    • The long-term efficacy of currently used dental implants: A review and proposed criteria of success
    • Albrektsson T, Zarb G, Worthington P, Eriksson A. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986; 1:11-25.
    • (1986) Int J Oral Maxillofac Implants , vol.1 , pp. 11-25
    • Albrektsson, T.1    Zarb, G.2    Worthington, P.3    Eriksson, A.4
  • 19
    • 0025583364 scopus 로고
    • A long-term follow-up study of osseointegrated implants in the treatment of the totally edentulous jaw
    • Adell R, Eriksson B, Lekholm U, Brånemark P-I, Jemt A. A long-term follow-up study of osseointegrated implants in the treatment of the totally edentulous jaw. Int J Oral Maxillofac Implants 1990; 5:347-359.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 347-359
    • Adell, R.1    Eriksson, B.2    Lekholm, U.3    Brånemark, P.-I.4    Jemt, A.5
  • 20
    • 0025493944 scopus 로고
    • The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: A prospective multicenter study on 558 fixtures
    • van Steenberghe D, Lekholm U, Holender C, et al. The applicability of osseointegrated oral implants in the rehabilitation of partial edentulism: a prospective multicenter study on 558 fixtures. Int J Oral Maxillofac Implants 1990; 5:272-281.
    • (1990) Int J Oral Maxillofac Implants , vol.5 , pp. 272-281
    • Van Steenberghe, D.1    Lekholm, U.2    Holender, C.3
  • 21
    • 0030322726 scopus 로고    scopus 로고
    • A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants
    • Lindquist LW, Carlsson GE, Jemt T. A prospective 15-year follow-up study of mandibular fixed prostheses supported by osseointegrated implants. Clin Oral Implants Res 1996; 7:329-336.
    • (1996) Clin Oral Implants Res , vol.7 , pp. 329-336
    • Lindquist, L.W.1    Carlsson, G.E.2    Jemt, T.3
  • 22
    • 0031261467 scopus 로고    scopus 로고
    • Hard and soft tissue reactions to ITI screw implants: 3-year longitudinal results of a prospective study
    • Behneke A, Behneke N, d'Hoedt B, Wagner W. Hard and soft tissue reactions to ITI screw implants: 3-year longitudinal results of a prospective study. Int J Oral Maxillofac Implants 1997; 12:749-757.
    • (1997) Int J Oral Maxillofac Implants , vol.12 , pp. 749-757
    • Behneke, A.1    Behneke, N.2    D'Hoedt, B.3    Wagner, W.4
  • 23
    • 0031152016 scopus 로고    scopus 로고
    • Long-term evaluation of non-submerged ITI implants. Part 1: 8-Year life table analysis of a prospective multi-center study with 2359 implants
    • Buser D, Mericske-Stern R, Bernard JP, et al. Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants. Clin Oral Implants Res 1997; 8:161-172.
    • (1997) Clin Oral Implants Res , vol.8 , pp. 161-172
    • Buser, D.1    Mericske-Stern, R.2    Bernard, J.P.3
  • 24
    • 0034575061 scopus 로고    scopus 로고
    • Nonsubmerged implants in the treatment of the edentulous upper jaw. A prospective clinical and radiographic study of ITI implants - Results after 1 year
    • Åstrand P, Anzén B, Karlsson U, Sahlholm S, Svärdström P, Hellem S. Nonsubmerged implants in the treatment of the edentulous upper jaw. A prospective clinical and radiographic study of ITI implants - results after 1 year. Clin Implant Dent Relat Res 2000; 2:166-174.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 166-174
    • Åstrand, P.1    Anzén, B.2    Karlsson, U.3    Sahlholm, S.4    Svärdström, P.5    Hellem, S.6
  • 25
    • 0034574917 scopus 로고    scopus 로고
    • A prospective multicenter clinical trial comparing one- and two-stage titanium screw-shaped fixtures with one-stage plasma-sprayed solid-screw fixtures
    • Becker W, Becker BE, Ricci A, et al. A prospective multicenter clinical trial comparing one- and two-stage titanium screw-shaped fixtures with one-stage plasma-sprayed solid-screw fixtures. Clin Implant Dent Relat Res 2002; 2: 159-165.
    • (2002) Clin Implant Dent Relat Res , vol.2 , pp. 159-165
    • Becker, W.1    Becker, B.E.2    Ricci, A.3
  • 27
    • 0035222876 scopus 로고    scopus 로고
    • Nonsubmerged implants in the treatment of the edentulous lower jaw: A 5-year prospective longitudinal study of ITI hollow screws
    • Hellem S, Karlsson U, Almfeldt I, Brunell G, Hamp SE, Åstrand P. Nonsubmerged implants in the treatment of the edentulous lower jaw: a 5-year prospective longitudinal study of ITI hollow screws. Clin Implant Dent Relat Res 2001; 3:20-29.
    • (2001) Clin Implant Dent Relat Res , vol.3 , pp. 20-29
    • Hellem, S.1    Karlsson, U.2    Almfeldt, I.3    Brunell, G.4    Hamp, S.E.5    Åstrand, P.6
  • 28
    • 0035463298 scopus 로고    scopus 로고
    • A prospective study of treatment of severely resorbed maxillae with narrow nonsubmerged implants: Results after 1 year of loading
    • Hallman M. A prospective study of treatment of severely resorbed maxillae with narrow nonsubmerged implants: results after 1 year of loading. Int J Oral Maxillofac Implants 2001; 16:731-736.
    • (2001) Int J Oral Maxillofac Implants , vol.16 , pp. 731-736
    • Hallman, M.1
  • 29
    • 0041881768 scopus 로고    scopus 로고
    • Long-term implant prognosis in patients with and without a history of chronic periodontitis: A 10 year prospective cohort study of the ITI Dental Implant System
    • Karoussis IK, Salvi GE, Heitz-Mayfield LJ, Brägger U, Hämmerle CH, Lang NP. Long-term implant prognosis in patients with and without a history of chronic periodontitis: a 10 year prospective cohort study of the ITI Dental Implant System. Clin Oral Implants Res 2003; 14:329-339.
    • (2003) Clin Oral Implants Res , vol.14 , pp. 329-339
    • Karoussis, I.K.1    Salvi, G.E.2    Heitz-Mayfield, L.J.3    Brägger, U.4    Hämmerle, C.H.5    Lang, N.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.