메뉴 건너뛰기




Volumn 17, Issue 1, 2008, Pages 3-8

Influence of fixation mode and superstructure span upon strain development of implant fixed partial dentures

Author keywords

Bridge span; Cement retention; Passive fit; Screw retention; Strain development; Superstructure accuracy

Indexed keywords

TOOTH CEMENT;

EID: 38049060005     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/j.1532-849X.2007.00236.x     Document Type: Article
Times cited : (27)

References (24)
  • 2
    • 0034305429 scopus 로고    scopus 로고
    • An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses
    • Pietrabissa R, Gionso L, Quaglini V, et al : An in vitro study on compensation of mismatch of screw versus cement-retained implant supported fixed prostheses. Clin Oral Implants Res 2000 11 : 448 457
    • (2000) Clin Oral Implants Res , vol.11 , pp. 448-457
    • Pietrabissa, R.1    Gionso, L.2    Quaglini, V.3
  • 3
    • 0026271905 scopus 로고
    • In vivo load measurements on osseointegrated implants supporting fixed or removable prostheses: A comparative pilot study
    • Jemt T, Carlsson L, Boss A, et al : In vivo load measurements on osseointegrated implants supporting fixed or removable prostheses: a comparative pilot study. Int J Oral Maxillofac Implants 1991 6 : 413 417
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 413-417
    • Jemt, T.1    Carlsson, L.2    Boss, A.3
  • 4
    • 0030090665 scopus 로고    scopus 로고
    • On the influence of superstructure connection on implant preload: A methodological and clinical study
    • Smedberg JI, Nilner K, Rangert B, et al : On the influence of superstructure connection on implant preload: a methodological and clinical study. Clin Oral Implants Res 1996 7 : 55 63
    • (1996) Clin Oral Implants Res , vol.7 , pp. 55-63
    • Smedberg, J.I.1    Nilner, K.2    Rangert, B.3
  • 5
    • 0029439074 scopus 로고
    • Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit
    • Clelland NL, Papazoglou E, Carr AB, et al : Comparison of strains transferred to a bone simulant among implant overdenture bars with various levels of misfit. J Prosthodont 1995 4 : 243 250
    • (1995) J Prosthodont , vol.4 , pp. 243-250
    • Clelland, N.L.1    Papazoglou, E.2    Carr, A.B.3
  • 6
    • 0030226140 scopus 로고    scopus 로고
    • Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant- supported fixed prosthesis
    • Clelland NL, Carr AB, Gilat A : Comparison of strains transferred to a bone simulant between as-cast and postsoldered implant frameworks for a five-implant- supported fixed prosthesis. J Prosthodont 1996 5 : 193 200
    • (1996) J Prosthodont , vol.5 , pp. 193-200
    • Clelland, N.L.1    Carr, A.B.2    Gilat, A.3
  • 7
    • 0034154709 scopus 로고    scopus 로고
    • Analysis of stress distribution in a screw-retained implant prosthesis
    • Watanabe F, Uno I, Hata Y, et al : Analysis of stress distribution in a screw-retained implant prosthesis. Int J Oral Maxillofac Implants 2000 15 : 209 218
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 209-218
    • Watanabe, F.1    Uno, I.2    Hata, Y.3
  • 8
    • 0026311384 scopus 로고
    • Comparison of impression techniques for a five-implant mandibular model
    • Carr AB : Comparison of impression techniques for a five-implant mandibular model. Int J Oral Maxillofac Implants 1991 6 : 448 455
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 448-455
    • Carr, A.B.1
  • 9
    • 0027031321 scopus 로고
    • Comparison of impression techniques for a two-implant 15-degree divergent model
    • Carr AB : Comparison of impression techniques for a two-implant 15-degree divergent model. Int J Oral Maxillofac Implants 1992 7 : 468 475
    • (1992) Int J Oral Maxillofac Implants , vol.7 , pp. 468-475
    • Carr, A.B.1
  • 10
    • 0034186663 scopus 로고    scopus 로고
    • In vitro comparison of master cast accuracy for single-tooth implant replacement
    • Vigolo P, Majzoub Z, Cordioli G : In vitro comparison of master cast accuracy for single-tooth implant replacement. J Prosthet Dent 2000 83 : 562 566
    • (2000) J Prosthet Dent , vol.83 , pp. 562-566
    • Vigolo, P.1    Majzoub, Z.2    Cordioli, G.3
  • 11
    • 0034185646 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for osseointegrated implant supported superstructures
    • Herbst D, Nel JC, Driessen CH, et al : Evaluation of impression accuracy for osseointegrated implant supported superstructures. J Prosthet Dent 2000 83 : 555 561
    • (2000) J Prosthet Dent , vol.83 , pp. 555-561
    • Herbst, D.1    Nel, J.C.2    Driessen, C.H.3
  • 13
    • 0029185973 scopus 로고
    • The clinical significance of distortion in implant prosthodontics: Is there such a thing as passive fit?
    • Tan KB : The clinical significance of distortion in implant prosthodontics: is there such a thing as passive fit? Ann Acad Med Singapore 1995 24 : 138 157
    • (1995) Ann Acad Med Singapore , vol.24 , pp. 138-157
    • Tan, K.B.1
  • 14
    • 0033129453 scopus 로고    scopus 로고
    • Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments
    • Keith SE, Miller BH, Woody RD, et al : Marginal discrepancy of screw-retained and cemented metal-ceramic crowns on implants abutments. Int J Oral Maxillofac Implants 1999 14 : 369 378
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 369-378
    • Keith, S.E.1    Miller, B.H.2    Woody, R.D.3
  • 15
    • 0030279335 scopus 로고    scopus 로고
    • An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructures
    • Cheshire PD, Hobkirk JA : An in vivo quantitative analysis of the fit of Nobel Biocare implant superstructures. J Oral Rehabil 1996 23 : 782 789
    • (1996) J Oral Rehabil , vol.23 , pp. 782-789
    • Cheshire, P.D.1    Hobkirk, J.A.2
  • 16
    • 0030238164 scopus 로고    scopus 로고
    • Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders
    • Carr AB, Brunski JB, Hurley E : Effects of fabrication, finishing, and polishing procedures on preload in prostheses using conventional "gold" and plastic cylinders. Int J Oral Maxillofac Implants 1996 11 : 589 598
    • (1996) Int J Oral Maxillofac Implants , vol.11 , pp. 589-598
    • Carr, A.B.1    Brunski, J.B.2    Hurley, E.3
  • 17
    • 0029395889 scopus 로고
    • Screw-retained versus cement-retained implant-supported prostheses
    • Misch CE : Screw-retained versus cement-retained implant-supported prostheses. Pract Periodontics Aesthet Dent 1995 7 : 15 18
    • (1995) Pract Periodontics Aesthet Dent , vol.7 , pp. 15-18
    • Misch, C.E.1
  • 18
    • 0030635617 scopus 로고    scopus 로고
    • Cement-retained versus screw-retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry
    • Hebel KS, Gajjar RC : Cement-retained versus screw-retained implant restorations: achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997 77 : 28 35
    • (1997) J Prosthet Dent , vol.77 , pp. 28-35
    • Hebel, K.S.1    Gajjar, R.C.2
  • 19
    • 0032602123 scopus 로고    scopus 로고
    • Cemented versus screw-retained implant prostheses: Which is better?
    • Chee W, Felton DA, Johnson PF, et al : Cemented versus screw-retained implant prostheses: which is better? Int J Oral Maxillofac Implants 1999 14 : 137 141
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 137-141
    • Chee, W.1    Felton, D.A.2    Johnson, P.F.3
  • 20
    • 0034151536 scopus 로고    scopus 로고
    • Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs
    • Guichet DL, Caputo AA, Choi H, et al : Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs. Int J Oral Maxillofac Implants 2000 15 : 239 246
    • (2000) Int J Oral Maxillofac Implants , vol.15 , pp. 239-246
    • Guichet, D.L.1    Caputo, A.A.2    Choi, H.3
  • 21
    • 4644336254 scopus 로고    scopus 로고
    • Cement fixation and screw retention: Parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures
    • Heckmann SM, Karl M, Wichmann MG, et al : Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures. Clin Oral Implants Res 2004 15 : 466 473
    • (2004) Clin Oral Implants Res , vol.15 , pp. 466-473
    • Heckmann, S.M.1    Karl, M.2    Wichmann, M.G.3
  • 22
    • 1342322624 scopus 로고    scopus 로고
    • In vitro study on passive fit in implant-supported 5-unit fixed partial dentures
    • Karl M, Winter W, Taylor TD, et al : In vitro study on passive fit in implant-supported 5-unit fixed partial dentures. Int J Oral Maxillofac Implants 2004 19 : 30 37
    • (2004) Int J Oral Maxillofac Implants , vol.19 , pp. 30-37
    • Karl, M.1    Winter, W.2    Taylor, T.D.3
  • 23
    • 0028504004 scopus 로고
    • Trabecular bone exhibits fully linear elastic behavior and yields at low strains
    • Keaveny TM, Guo XE, Wachtel EF, et al : Trabecular bone exhibits fully linear elastic behavior and yields at low strains. J Biomech 1994 27 : 1127 1136
    • (1994) J Biomech , vol.27 , pp. 1127-1136
    • Keaveny, T.M.1    Guo, X.E.2    Wachtel, E.F.3
  • 24
    • 0029377054 scopus 로고
    • Elongation and preload stress in dental implant abutment screws
    • Haack JE, Sakaguchi RL, Sun T, et al : Elongation and preload stress in dental implant abutment screws. Int J Oral Maxillofac Implants 1995 10 : 529 536
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 529-536
    • Haack, J.E.1    Sakaguchi, R.L.2    Sun, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.