-
1
-
-
0004232630
-
-
2nd ed. Cambridge: Royal Society of Chemistry
-
Adams, M.R., M.O. Moss. Food Microbiology, 2nd ed. Cambridge: Royal Society of Chemistry, 2000, pp 395-438.
-
(2000)
Food Microbiology
, pp. 395-438
-
-
Adams, M.R.1
Moss, M.O.2
-
5
-
-
0003850783
-
-
Cambridge: Royal Society of Chemistry
-
Scott, A.O. Biosensors for food analysis. Cambridge: Royal Society of Chemistry, 1998, pp 1-9.
-
(1998)
Biosensors for food analysis
, pp. 1-9
-
-
Scott, A.O.1
-
7
-
-
0014191637
-
Enzyme electrode
-
Updike, S., G. Hicks. Enzyme electrode. Nature 214:986, 1967.
-
(1967)
Nature
, vol.214
, pp. 986
-
-
Updike, S.1
Hicks, G.2
-
8
-
-
85133986766
-
Investigation of organic phase biosensor for measuring glucose in flow injection analysis system
-
[In press]
-
Adanyi, N., M. Toth-Markus, E.E. Szabo, M. Varadi, M.P. Sammartino, M. Tomassetti, L. Campanella. Investigation of organic phase biosensor for measuring glucose in flow injection analysis system. Anal. Chim. Acta, 2003. [In press]
-
(2003)
Anal. Chim. Acta
-
-
Adanyi, N.1
Toth-Markus, M.2
Szabo, E.E.3
Varadi, M.4
Sammartino, M.P.5
Tomassetti, M.6
Campanella, L.7
-
9
-
-
0038324427
-
Prussian blue and enzyme bulk-modified screen-printed electrodes for hydrogen peroxide and glucose determination with improved storage and operational stability
-
Ricci, F., A. Amine, C.S. Tuta, A.A. Ciucu, F. Lucarelli, G. Palleschi, D. Moscone. Prussian blue and enzyme bulk-modified screen-printed electrodes for hydrogen peroxide and glucose determination with improved storage and operational stability. Anal. Chim. Acta 485:111-120, 2003.
-
(2003)
Anal. Chim. Acta
, vol.485
, pp. 111-120
-
-
Ricci, F.1
Amine, A.2
Tuta, C.S.3
Ciucu, A.A.4
Lucarelli, F.5
Palleschi, G.6
Moscone, D.7
-
10
-
-
0037671541
-
Simultaneous detection of ethanol, glucose and glycerol in wines using pyrroloquinoline quinone-dependent dehydrogenases based biosensors
-
Niculescu, M., R. Mieliauskiene, V. Laurinavicius, E. Csöregi. Simultaneous detection of ethanol, glucose and glycerol in wines using pyrroloquinoline quinone-dependent dehydrogenases based biosensors. Food Chem. 82:481-489, 2003.
-
(2003)
Food Chem
, vol.82
, pp. 481-489
-
-
Niculescu, M.1
Mieliauskiene, R.2
Laurinavicius, V.3
Csöregi, E.4
-
11
-
-
0035955837
-
Prussian blue-based optical glucose biosensor in flow-injection analysis
-
Lenarczuk, T., D. Wencel, S. Glab, R. Koncki. Prussian blue-based optical glucose biosensor in flow-injection analysis. Anal. Chim. Acta 447:23-32, 2001.
-
(2001)
Anal. Chim. Acta
, vol.447
, pp. 23-32
-
-
Lenarczuk, T.1
Wencel, D.2
Glab, S.3
Koncki, R.4
-
13
-
-
0034325046
-
Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films
-
Palmisano, F., R. Rizzi, D. Centonze, P.G. Zambonin. Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films. Biosens. Bioelectron. 15:531-539, 2000.
-
(2000)
Biosens. Bioelectron
, vol.15
, pp. 531-539
-
-
Palmisano, F.1
Rizzi, R.2
Centonze, D.3
Zambonin, P.G.4
-
14
-
-
0032671297
-
Renewable silica sol-gel derived carbon composite based glucose biosensor
-
Chia, J.L.L.S., N.K. Goh, S.N. Tan. Renewable silica sol-gel derived carbon composite based glucose biosensor. J. Electroanal. Chem. 460:234-241, 1999.
-
(1999)
J. Electroanal. Chem
, vol.460
, pp. 234-241
-
-
Chia, J.L.L.S.1
Goh, N.K.2
Tan, S.N.3
-
15
-
-
0032939591
-
Dual electrode signal-subtracted biosensor for simultaneous flow injection determination of sucrose and glucose
-
Surareungchai, W., W. Supinda, P. Sritongkum, M. Tanticharoen, K. Kirtikara. Dual electrode signal-subtracted biosensor for simultaneous flow injection determination of sucrose and glucose. Anal. Chim. Acta 380:7-15, 1999.
-
(1999)
Anal. Chim. Acta
, vol.380
, pp. 7-15
-
-
Surareungchai, W.1
Supinda, W.2
Sritongkum, P.3
Tanticharoen, M.4
Kirtikara, K.5
-
16
-
-
0032117892
-
Determination of glucose, ascorbic and citric acids by two-ISFET multienzyme sensor
-
Volotovsky, V., N. Kim. Determination of glucose, ascorbic and citric acids by two-ISFET multienzyme sensor. Sens. Actuators B 49:253-257, 1998.
-
(1998)
Sens. Actuators B
, vol.49
, pp. 253-257
-
-
Volotovsky, V.1
Kim, N.2
-
17
-
-
0037210262
-
Adaptation of a manometric biosensor to measure glucose and lactose
-
Jenkins, D.M., M.J. Delwiche. Adaptation of a manometric biosensor to measure glucose and lactose. Biosens. Bioelectron. 18:101-107, 2003.
-
(2003)
Biosens. Bioelectron
, vol.18
, pp. 101-107
-
-
Jenkins, D.M.1
Delwiche, M.J.2
-
18
-
-
0343652762
-
Rapid determination of lactulose in milk by microdialysis and biosensors
-
Moscone, D., R.A. Bernardo, E. Marconi, A. Amine, G. Palleschi. Rapid determination of lactulose in milk by microdialysis and biosensors. Analyst 124:325-329, 1999.
-
(1999)
Analyst
, vol.124
, pp. 325-329
-
-
Moscone, D.1
Bernardo, R.A.2
Marconi, E.3
Amine, A.4
Palleschi, G.5
-
19
-
-
0002770174
-
Determination of D-fructose in foodstuffs by an improved amperometric biosensor based on a solid binding matrix
-
Stredansky, M., A. Pizzariello, S. Stredanska, S. Miertus. Determination of D-fructose in foodstuffs by an improved amperometric biosensor based on a solid binding matrix. Anal. Commun. 36:57-61, 1999.
-
(1999)
Anal. Commun
, vol.36
, pp. 57-61
-
-
Stredansky, M.1
Pizzariello, A.2
Stredanska, S.3
Miertus, S.4
-
20
-
-
0035105117
-
Amperometric flow-injection determination of sucrose with a mediated tri-enzyme electrode based on sucrose phosphorylase and electro-catalytic oxidation of NADH
-
Maestre, E., I. Katakis, E. Dominguez. Amperometric flow-injection determination of sucrose with a mediated tri-enzyme electrode based on sucrose phosphorylase and electro-catalytic oxidation of NADH. Biosens. Bioelectron. 16:61-68, 2001.
-
(2001)
Biosens. Bioelectron
, vol.16
, pp. 61-68
-
-
Maestre, E.1
Katakis, I.2
Dominguez, E.3
-
21
-
-
85133989336
-
Screen-printed enzyme electrodes for the detection of marker analytes during winemaking
-
Lupu, A., D. Companone, G. Palleschi. Screen-printed enzyme electrodes for the detection of marker analytes during winemaking. Anal. Chim. Acta 2003.
-
(2003)
Anal. Chim. Acta
-
-
Lupu, A.1
Companone, D.2
Palleschi, G.3
-
22
-
-
0038482031
-
Graphite-teflon composite bienzyme amperometric biosensors for monitoring of alcohols
-
De Prada, A.G.V., N. Pena, M.L. Mena, A.J. Reviejo, J.M. Pingarron. Graphite-teflon composite bienzyme amperometric biosensors for monitoring of alcohols. Biosens. Bioelectron. 18:1279-1288, 2003.
-
(2003)
Biosens. Bioelectron
, vol.18
, pp. 1279-1288
-
-
De Prada, A.G.V.1
Pena, N.2
Mena, M.L.3
Reviejo, A.J.4
Pingarron, J.M.5
-
23
-
-
0037118792
-
Quinohemoprotein alcohol dehydrogenase-based reagentless amperometric biosensor for ethanol monitoring during wine fermentation
-
Niculescu, M., T. Erichsen, V. Sukharev, Z. Kerenyi, E. Csöregi, W. Schuhmann. Quinohemoprotein alcohol dehydrogenase-based reagentless amperometric biosensor for ethanol monitoring during wine fermentation. Anal. Chim. Acta 463:39-51, 2002.
-
(2002)
Anal. Chim. Acta
, vol.463
, pp. 39-51
-
-
Niculescu, M.1
Erichsen, T.2
Sukharev, V.3
Kerenyi, Z.4
Csöregi, E.5
Schuhmann, W.6
-
24
-
-
0344464873
-
HRP-based amperometric biosensor for the polyphenols determination in vegetables extract
-
Mello, L.D., M.P. Taboada Sotomayor, L.T. Kubota. HRP-based amperometric biosensor for the polyphenols determination in vegetables extract. Sens. Actuators. B 96:636-645, 2003.
-
(2003)
Sens. Actuators. B
, vol.96
, pp. 636-645
-
-
Mello, L.D.1
Taboada Sotomayor, M.P.2
Kubota, L.T.3
-
25
-
-
0033829089
-
Electrochemical sensor and biosensor for polyphenols detection in olive oils
-
Capannesi, C., I. Palchetti, M. Mascini, A. Parenti. Electrochemical sensor and biosensor for polyphenols detection in olive oils. Food Chem. 71:553-562, 2000.
-
(2000)
Food Chem
, vol.71
, pp. 553-562
-
-
Capannesi, C.1
Palchetti, I.2
Mascini, M.3
Parenti, A.4
-
26
-
-
0037193052
-
Screen-printed biosensors for the control of wine quality based on lactate and acetaldehyde determination
-
Avramescu, A., T. Noguer, M. Avramescu, J.L. Marty. Screen-printed biosensors for the control of wine quality based on lactate and acetaldehyde determination. Anal. Chim. Acta 458:203-213, 2002.
-
(2002)
Anal. Chim. Acta
, vol.458
, pp. 203-213
-
-
Avramescu, A.1
Noguer, T.2
Avramescu, M.3
Marty, J.L.4
-
27
-
-
0032911638
-
Biosensors for L-malate and L-lactate based on solid binding matrix
-
Katrlik, J., A. Pizzariello, V. Mastihuba, J. Svorc, M. Stredansky, S. Miertus. Biosensors for L-malate and L-lactate based on solid binding matrix. Anal. Chim. Acta 379:193-200, 1999.
-
(1999)
Anal. Chim. Acta
, vol.379
, pp. 193-200
-
-
Katrlik, J.1
Pizzariello, A.2
Mastihuba, V.3
Svorc, J.4
Stredansky, M.5
Miertus, S.6
-
28
-
-
0033620592
-
Graphite-teflon composite bienzyme electrodes for the determination of L-lactate: Application to food samples
-
Serra, B., A.J. Reviejo, C. Parrado, J.M. Pingarron. Graphite-teflon composite bienzyme electrodes for the determination of L-lactate: application to food samples. Biosens. Bioelectron. 14:505-513, 1999.
-
(1999)
Biosens. Bioelectron
, vol.14
, pp. 505-513
-
-
Serra, B.1
Reviejo, A.J.2
Parrado, C.3
Pingarron, J.M.4
-
29
-
-
12444326802
-
Flow injection analysis of acetic acid in food samples by using trienzyme/poly(dimethylsiloxane)-bilayer membrane-based electrode as the detector
-
Mizutani, F., Y. Hirata, S. Yabuki, S. Iijima. Flow injection analysis of acetic acid in food samples by using trienzyme/poly(dimethylsiloxane)-bilayer membrane-based electrode as the detector. Sens. Actuators B 91:195-198, 2003.
-
(2003)
Sens. Actuators B
, vol.91
, pp. 195-198
-
-
Mizutani, F.1
Hirata, Y.2
Yabuki, S.3
Iijima, S.4
-
30
-
-
0033659396
-
An enzyme electrode for extended linearity citrate measurements based on modified polymeric membranes
-
Maines, A., M.I. Prodromidis, S.M. Tzouwara-Karayanni, M.I. Karayannis, D. Ashworth, P. Vadgama. An enzyme electrode for extended linearity citrate measurements based on modified polymeric membranes. Electroanalysis 12:1118-1123, 2000.
-
(2000)
Electroanalysis
, vol.12
, pp. 1118-1123
-
-
Maines, A.1
Prodromidis, M.I.2
Tzouwara-Karayanni, S.M.3
Karayannis, M.I.4
Ashworth, D.5
Vadgama, P.6
-
31
-
-
0345466569
-
A new enzyme electrode based on ascorbate oxidase immobilized in gelatin for specific determination of L-ascorbic acid
-
Akyilmaz, E., E. Dinckaya. A new enzyme electrode based on ascorbate oxidase immobilized in gelatin for specific determination of L-ascorbic acid. Talanta 50:87-93, 1999.
-
(1999)
Talanta
, vol.50
, pp. 87-93
-
-
Akyilmaz, E.1
Dinckaya, E.2
-
32
-
-
0343526454
-
Biosensor-based determination of folic acid in fortified food
-
Caselunghe, M.B., J. Lindeberg. Biosensor-based determination of folic acid in fortified food. Food Chem. 70:523-532, 2000.
-
(2000)
Food Chem
, vol.70
, pp. 523-532
-
-
Caselunghe, M.B.1
Lindeberg, J.2
-
33
-
-
0042977468
-
Hydrogel network entrapping cholesterol oxidase and octadecylsil-ica for optical biosensing in hydrophobic organic or aqueous micelle solvents
-
Wu, X.J., M.M.F. Choi. Hydrogel network entrapping cholesterol oxidase and octadecylsil-ica for optical biosensing in hydrophobic organic or aqueous micelle solvents. Anal. Chem. 75:4019-4027, 2003.
-
(2003)
Anal. Chem
, vol.75
, pp. 4019-4027
-
-
Wu, X.J.1
Choi, M.M.F.2
-
34
-
-
0035892690
-
Chiral analysis of amino acids using electrochemical composite bienzyme biosensors
-
Dominguez, R., B. Serra, A.J. Reviejo, J.M. Pingarron. Chiral analysis of amino acids using electrochemical composite bienzyme biosensors. Anal. Biochem. 298:275-282, 2001.
-
(2001)
Anal. Biochem
, vol.298
, pp. 275-282
-
-
Dominguez, R.1
Serra, B.2
Reviejo, A.J.3
Pingarron, J.M.4
-
35
-
-
0034621522
-
Development of an interferent free amperometric biosensor for determination of L-lysine in food
-
Kelly, S.C., P.J. O'Connell, C.K. O'Sullivan, G.G. Guilbault. Development of an interferent free amperometric biosensor for determination of L-lysine in food. Anal. Chim. Acta 412:111-119, 2000.
-
(2000)
Anal. Chim. Acta
, vol.412
, pp. 111-119
-
-
Kelly, S.C.1
O'Connell, P.J.2
O'Sullivan, C.K.3
Guilbault, G.G.4
-
36
-
-
0034034017
-
Redox hydrogel based amperometric bienzyme electrodes for fish freshness monitoring
-
Niculescu, M., C. Nistor, I. Frebort, P. Pec, B. Mattiasson, E. Csoregi. Redox hydrogel based amperometric bienzyme electrodes for fish freshness monitoring. Anal. Chem. 72, 2000.
-
(2000)
Anal. Chem
, pp. 72
-
-
Niculescu, M.1
Nistor, C.2
Frebort, I.3
Pec, P.4
Mattiasson, B.5
Csoregi, E.6
-
37
-
-
0034621356
-
Biosensor for detection of hypoxanthine based on xanthine oxidase immobilised on chemically modified carbon paste electrode
-
Hu, S., C. Xu, J. Luo, D. Cui. Biosensor for detection of hypoxanthine based on xanthine oxidase immobilised on chemically modified carbon paste electrode. Anal. Chim. Acta 412:55-61, 2000.
-
(2000)
Anal. Chim. Acta
, vol.412
, pp. 55-61
-
-
Hu, S.1
Xu, C.2
Luo, J.3
Cui, D.4
-
38
-
-
0000869268
-
A bienzyme electrode (alkaline phosphatase - polyphenol oxidase) for the amperometric determination of phosphate
-
Cosnier, S., C. Gondran, J.C. Watelet, W. Giovani, R.P.M. Furriel, F.A. Leone. A bienzyme electrode (alkaline phosphatase - polyphenol oxidase) for the amperometric determination of phosphate. Anal. Chem. 70:3952-3956, 1998.
-
(1998)
Anal. Chem
, vol.70
, pp. 3952-3956
-
-
Cosnier, S.1
Gondran, C.2
Watelet, J.C.3
Giovani, W.4
Furriel, R.P.M.5
Leone, F.A.6
-
39
-
-
0033899627
-
Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer
-
Abass, A.K., J.P. Hart, D. Cowell. Development of an amperometric sulfite biosensor based on sulfite oxidase with cytochrome c, as electron acceptor, and a screen-printed transducer. Sens. Actuators B 62:148-153, 2000.
-
(2000)
Sens. Actuators B
, vol.62
, pp. 148-153
-
-
Abass, A.K.1
Hart, J.P.2
Cowell, D.3
-
40
-
-
0037086224
-
A biosensor for Escherichia coli based on a potentiometric alternating biosensing (PAB) transducer
-
Ercole, C., M. Del Gallo, M. Pantalone, S. Santucci, L. Mosiello, C. Laconi, A. Lepidi. A biosensor for Escherichia coli based on a potentiometric alternating biosensing (PAB) transducer. Sens. Actuators B. 83:48-52, 2002.
-
(2002)
Sens. Actuators B
, vol.83
, pp. 48-52
-
-
Ercole, C.1
Del Gallo, M.2
Pantalone, M.3
Santucci, S.4
Mosiello, L.5
Laconi, C.6
Lepidi, A.7
-
41
-
-
0035971749
-
Piezoelectric quartz crystal based veterinary diagnosis for Salmonella enteritidis infection in chicken and egg
-
Su, X., S. Low, J. Kwang, V.H.T. Chew, S.F.Y. Li. Piezoelectric quartz crystal based veterinary diagnosis for Salmonella enteritidis infection in chicken and egg. Sens. Actuators B. 75:29-35, 2001.
-
(2001)
Sens. Actuators B
, vol.75
, pp. 29-35
-
-
Su, X.1
Low, S.2
Kwang, J.3
Chew, V.H.T.4
Li, S.F.Y.5
-
42
-
-
0038664279
-
Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor
-
Bokken, G.C.A.M., R.J. Corbee, F. Knapen, A.A. Bergwerff. Immunochemical detection of Salmonella group B, D and E using an optical surface plasmon resonance biosensor. FEMS Microbiol. Lett. 222:75-82, 2003.
-
(2003)
FEMS Microbiol. Lett
, vol.222
, pp. 75-82
-
-
Bokken, G.C.A.M.1
Corbee, R.J.2
Knapen, F.3
Bergwerff, A.A.4
-
43
-
-
0034666508
-
Multitoxin biosensor-mass spectrometry analysis: A new approach for rapid, real-time, sensitive analysis of staphylococcal toxins in food
-
Nedelkov, D., A. Rasooly, R.W. Nelson. Multitoxin biosensor-mass spectrometry analysis: a new approach for rapid, real-time, sensitive analysis of staphylococcal toxins in food. Int. J. Food Microb. 60:1-13, 2000.
-
(2000)
Int. J. Food Microb
, vol.60
, pp. 1-13
-
-
Nedelkov, D.1
Rasooly, A.2
Nelson, R.W.3
-
44
-
-
0037210445
-
Detection of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor
-
Pogacnik, L., M. Franko. Detection of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor. Biosens. Bioelectron. 18:1-9, 2003.
-
(2003)
Biosens. Bioelectron
, vol.18
, pp. 1-9
-
-
Pogacnik, L.1
Franko, M.2
-
45
-
-
0035979850
-
Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology
-
Albareda-Sirvent, M., A. Merkoci, S. Alegret. Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology. Anal. Chim. Acta 442:35-44, 2001.
-
(2001)
Anal. Chim. Acta
, vol.442
, pp. 35-44
-
-
Albareda-Sirvent, M.1
Merkoci, A.2
Alegret, S.3
-
46
-
-
0037057093
-
Biosensor analysis of penicillin G in milk based on the inhibition of carboxypeptidase activity
-
Gustavsson, E., P. Bjurling, Å. Sternesjö. Biosensor analysis of penicillin G in milk based on the inhibition of carboxypeptidase activity. Anal. Chim. Acta 468:153-159, 2002.
-
(2002)
Anal. Chim. Acta
, vol.468
, pp. 153-159
-
-
Gustavsson, E.1
Bjurling, P.2
Sternesjö, A.3
-
47
-
-
0035849631
-
Screening of penicillin residues in milk by a surface plasmon resonance-based biosensor assay: Comparison of chemical and enzymatic sample pre-treatment
-
Gaudin, V., J. Fontaine, P. Maris. Screening of penicillin residues in milk by a surface plasmon resonance-based biosensor assay: comparison of chemical and enzymatic sample pre-treatment. Anal. Chim. Acta 436:191-198, 2001.
-
(2001)
Anal. Chim. Acta
, vol.436
, pp. 191-198
-
-
Gaudin, V.1
Fontaine, J.2
Maris, P.3
-
48
-
-
0034351361
-
Inhibitive determination of mercury and other metal ions by potentiometric urea biosensor
-
Krawczyk, T.K., M. Moszczynska, M. Trojanowicz. Inhibitive determination of mercury and other metal ions by potentiometric urea biosensor. Biosens. Bioelectron. 15:681-691, 2000.
-
(2000)
Biosens. Bioelectron
, vol.15
, pp. 681-691
-
-
Krawczyk, T.K.1
Moszczynska, M.2
Trojanowicz, M.3
-
49
-
-
0036096757
-
Review of the use of biosensors as analytical tools in the food and drink industries
-
Mello, L.D., L.T. Kubota. Review of the use of biosensors as analytical tools in the food and drink industries. Food Chem. 77:237-256, 2002.
-
(2002)
Food Chem
, vol.77
, pp. 237-256
-
-
Mello, L.D.1
Kubota, L.T.2
-
50
-
-
12444320087
-
Amperometric enzymebased biosensors for application in food and beverage industry
-
de Cuyper, M., J.W.M. Bulte, eds., Dordrecht: Kluwer
-
Csöregi, E., S. Gáspár, M. Niculescu, B. Mattiasson, W. Schuhmann. Amperometric enzymebased biosensors for application in food and beverage industry. In: Focus on Biotechnology Series: Physics and Chemistry Basis of Biotechnology, de Cuyper, M., J.W.M. Bulte, eds., Dordrecht: Kluwer, 2001, pp 105-129.
-
(2001)
Focus on Biotechnology Series: Physics and Chemistry Basis of Biotechnology
, pp. 105-129
-
-
Csöregi, E.1
Gáspár, S.2
Niculescu, M.3
Mattiasson, B.4
Schuhmann, W.5
-
51
-
-
0035974963
-
Amperometric detection of glucose and ethanol in beverages using flow cell and immobilised on screen-printed carbon electrode PQQ-dependent glucose or alcohol dehydrogenases
-
Razumiene, J., V. Gureviciene, V. Laurinavicius, J.V. Gražulevicius. Amperometric detection of glucose and ethanol in beverages using flow cell and immobilised on screen-printed carbon electrode PQQ-dependent glucose or alcohol dehydrogenases. Sens. Actuators B. 78(1-3):243-248, 2001.
-
(2001)
Sens. Actuators B
, vol.78
, Issue.1-3
, pp. 243-248
-
-
Razumiene, J.1
Gureviciene, V.2
Laurinavicius, V.3
Gražulevicius, J.V.4
-
52
-
-
0037450021
-
New bioorganometallic ferrocene derivatives as efficient mediators for glucose and ethanol biosensors based on PQQ-dependent dehydrogenases
-
Razumiene, J., A. Vilkanauskyte, V. Gureviciene, V. Laurinavicius, N.V. Roznyatovskaya, Y.V. Ageeva, M.D. Reshetova, A.D. Ryabov. New bioorganometallic ferrocene derivatives as efficient mediators for glucose and ethanol biosensors based on PQQ-dependent dehydrogenases. J. Org. Chem. 668(1,2):83-90, 2003.
-
(2003)
J. Org. Chem
, vol.668
, Issue.1-2
, pp. 83-90
-
-
Razumiene, J.1
Vilkanauskyte, A.2
Gureviciene, V.3
Laurinavicius, V.4
Roznyatovskaya, N.V.5
Ageeva, Y.V.6
Reshetova, M.D.7
Ryabov, A.D.8
-
53
-
-
0035927844
-
Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases
-
de Mattos, I.L., L.V. Lukachova, L. Gorton, T. Laurell, A.A. Karyakin. Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases. Talanta 54(5):963-974, 2001.
-
(2001)
Talanta
, vol.54
, Issue.5
, pp. 963-974
-
-
de Mattos, I.L.1
Lukachova, L.V.2
Gorton, L.3
Laurell, T.4
Karyakin, A.A.5
-
54
-
-
0035902637
-
Fructose biosensor based on D-fructose dehydrogenase immobilised on a ferrocene-embedded cellulose acetate membrane
-
Tkác, J., I. Voštiar, E. Šturdík, P. Gemeiner, V. Mastihuba, J. Annus. Fructose biosensor based on D-fructose dehydrogenase immobilised on a ferrocene-embedded cellulose acetate membrane Anal. Chim. Acta 439(1):39-46, 2001.
-
(2001)
Anal. Chim. Acta
, vol.439
, Issue.1
, pp. 39-46
-
-
Tkác, J.1
Voštiar, I.2
Šturdík, E.3
Gemeiner, P.4
Mastihuba, V.5
Annus, J.6
-
55
-
-
0037193044
-
Yeast cells sucrose biosensor based on a potentiometric oxygen electrode
-
Rotariu, L., C. Bala, V. Magearu. Yeast cells sucrose biosensor based on a potentiometric oxygen electrode. Anal. Chim. Acta 458(1):215-222, 2002.
-
(2002)
Anal. Chim. Acta
, vol.458
, Issue.1
, pp. 215-222
-
-
Rotariu, L.1
Bala, C.2
Magearu, V.3
-
56
-
-
0036381542
-
Reticulated vitreous carbon based composite bienzyme electrodes for the determination of alcohols in beer samples
-
Pena, N., R. Tàrrega, A.J. Reviejo, J.M. Pingarròn. Reticulated vitreous carbon based composite bienzyme electrodes for the determination of alcohols in beer samples. Anal. Lett. 35(12):1931-1944, 2002.
-
(2002)
Anal. Lett
, vol.35
, Issue.12
, pp. 1931-1944
-
-
Pena, N.1
Tàrrega, R.2
Reviejo, A.J.3
Pingarròn, J.M.4
-
57
-
-
0037093904
-
Monitoring of ethanol during fermentation using a microbial biosensor with enhanced selectivity
-
Tkac, J., I. Vostiar, P. Gemeiner, E. Sturdik. Monitoring of ethanol during fermentation using a microbial biosensor with enhanced selectivity. Bioelectrochemistry 56(1,2):127-129, 2002.
-
(2002)
Bioelectrochemistry
, vol.56
, Issue.1-2
, pp. 127-129
-
-
Tkac, J.1
Vostiar, I.2
Gemeiner, P.3
Sturdik, E.4
-
58
-
-
85133992445
-
Comparison between three amperometric sensors for phenol determination in olive oil samples
-
Campo Dall'Orto, V., C. Danilowicz, I. Rezzano, M. Del Carlo, M. Mascini. Comparison between three amperometric sensors for phenol determination in olive oil samples. Anal. Lett. 231:124-131, 1999.
-
(1999)
Anal. Lett
, vol.231
, pp. 124-131
-
-
Campo Dall'Orto, V.1
Danilowicz, C.2
Rezzano, I.3
Del Carlo, M.4
Mascini, M.5
-
59
-
-
0034012473
-
Comparison among differential pulse voltammetry, amperometric biosensor, and HPLC/ DAD analysis for polyphenol determination
-
Romani, A., M. Minunni, N. Mulinacci, P. Pinelli, F.F. Vincieri, M. Del Carlo, M. Mascini. Comparison among differential pulse voltammetry, amperometric biosensor, and HPLC/ DAD analysis for polyphenol determination. J. Agric. Food Chem. 48(4):1197-1203, 2000.
-
(2000)
J. Agric. Food Chem
, vol.48
, Issue.4
, pp. 1197-1203
-
-
Romani, A.1
Minunni, M.2
Mulinacci, N.3
Pinelli, P.4
Vincieri, F.F.5
Del Carlo, M.6
Mascini, M.7
-
60
-
-
0036136865
-
Measurement of protein using an electrochemical bi-enzyme sensor
-
Setford, S.J., S.F. White, J.A. Bolbot. Measurement of protein using an electrochemical bi-enzyme sensor. Biosens. Bioelectron. 17(1,2):79-86, 2002.
-
(2002)
Biosens. Bioelectron
, vol.17
, Issue.1-2
, pp. 79-86
-
-
Setford, S.J.1
White, S.F.2
Bolbot, J.A.3
-
61
-
-
0036329224
-
An amperometric biosensor for determining amino acids using a bienzymatic system containing amino acid oxidase and protease
-
Kwan, R.C.H., C. Chan, R. Renneberg. An amperometric biosensor for determining amino acids using a bienzymatic system containing amino acid oxidase and protease. Biotechnol. Lett. 24(14):1203-1207, 2002.
-
(2002)
Biotechnol. Lett
, vol.24
, Issue.14
, pp. 1203-1207
-
-
Kwan, R.C.H.1
Chan, C.2
Renneberg, R.3
-
62
-
-
0036178322
-
Biosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine
-
Moser, I., G. Jobst, G.A. Urban. Biosensor arrays for simultaneous measurement of glucose, lactate, glutamate, and glutamine. Biosens. Bioelectron. 17(4):297-302, 2002.
-
(2002)
Biosens. Bioelectron
, vol.17
, Issue.4
, pp. 297-302
-
-
Moser, I.1
Jobst, G.2
Urban, G.A.3
-
63
-
-
0037120989
-
Rapid measurement of fish freshness indices by an amperometric flow-injection system with a 16-way switching valve and immobilized enzyme reactors
-
Nanjyo, Y., T. Yao. Rapid measurement of fish freshness indices by an amperometric flow-injection system with a 16-way switching valve and immobilized enzyme reactors. Anal. Chim. Acta 470(2):175-183, 2002.
-
(2002)
Anal. Chim. Acta
, vol.470
, Issue.2
, pp. 175-183
-
-
Nanjyo, Y.1
Yao, T.2
-
64
-
-
0037021758
-
Assay of fish freshness using trimethylamine vapor probe based on a sensitive membrane on piezoelectric quartz crystal
-
Zhao, C., Y. Pan, L. Ma, Z. Tang, G. Zhao, L. Wang. Assay of fish freshness using trimethylamine vapor probe based on a sensitive membrane on piezoelectric quartz crystal. Sens. Actuators B 81(2,3):218-222, 2002.
-
(2002)
Sens. Actuators B
, vol.81
, Issue.2-3
, pp. 218-222
-
-
Zhao, C.1
Pan, Y.2
Ma, L.3
Tang, Z.4
Zhao, G.5
Wang, L.6
-
65
-
-
0007956010
-
Characterization and application of glycerol dehydrogenase from Gluconobacter sp. 33
-
Marcinkeviciene, L., I. Bachmatova, R. Semenaite, I. Lapenaite, B. Kurtinaitiene, V. Laurinavicius, R. Meskys. Characterization and application of glycerol dehydrogenase from Gluconobacter sp. 33. Biologija 2:49-51, 2000.
-
(2000)
Biologija
, vol.2
, pp. 49-51
-
-
Marcinkeviciene, L.1
Bachmatova, I.2
Semenaite, R.3
Lapenaite, I.4
Kurtinaitiene, B.5
Laurinavicius, V.6
Meskys, R.7
-
66
-
-
0000164035
-
Purification and characterization of alcoholdehydrogenase from Gluconobacter sp. 33
-
Marcinkeviciene, L., I. Bachmatova, R. Semenaite, R. Rudomanskis, G. Brazenas, R. Meskiene, R. Meskys. Purification and characterization of alcoholdehydrogenase from Gluconobacter sp. 33. Biologija 2:25-30, 1999.
-
(1999)
Biologija
, vol.2
, pp. 25-30
-
-
Marcinkeviciene, L.1
Bachmatova, I.2
Semenaite, R.3
Rudomanskis, R.4
Brazenas, G.5
Meskiene, R.6
Meskys, R.7
-
67
-
-
0342387160
-
Purification and characterization of PQQ-dependent glucose dehy-drogenase from Erwinia sp.34-1
-
Marcinkeviciene, L., I. Bachmatova, R. Semenaite, R. Rudomanskis, G. Brazenas, R. Meskiene, R. Meskys. Purification and characterization of PQQ-dependent glucose dehy-drogenase from Erwinia sp.34-1. Biotech. Lett. 21:187-192, 1999.
-
(1999)
Biotech. Lett
, vol.21
, pp. 187-192
-
-
Marcinkeviciene, L.1
Bachmatova, I.2
Semenaite, R.3
Rudomanskis, R.4
Brazenas, G.5
Meskiene, R.6
Meskys, R.7
-
68
-
-
0141535353
-
Biogenic amines in dry fermented sausages: A review
-
Suzzi, G., F. Gardini. Biogenic amines in dry fermented sausages: a review. Int. J. Food Microb. 88:41-54, 2003.
-
(2003)
Int. J. Food Microb
, vol.88
, pp. 41-54
-
-
Suzzi, G.1
Gardini, F.2
-
69
-
-
0032745921
-
Biosensors for the detection of pathogenic bacteria
-
Invitski, D., I. Abdel-Hamid, P. Atanasov, E. Wilkins. Biosensors for the detection of pathogenic bacteria. Biosens. Bioelectron. 14:599-624, 1999.
-
(1999)
Biosens. Bioelectron
, vol.14
, pp. 599-624
-
-
Invitski, D.1
Abdel-Hamid, I.2
Atanasov, P.3
Wilkins, E.4
-
70
-
-
33645107123
-
Waterborne pathogens kill 10M-20M people/year
-
June 6
-
Anonymous. Waterborne pathogens kill 10M-20M people/year. World Water Environ. Eng. June 6, 1996.
-
(1996)
World Water Environ. Eng
-
-
-
71
-
-
0034973415
-
Listeria monocytogenes: A continuing challenge
-
Donnelly, C.W. Listeria monocytogenes: a continuing challenge. Nutr. Rev. 59:183-94, 2001.
-
(2001)
Nutr. Rev
, vol.59
, pp. 183-194
-
-
Donnelly, C.W.1
-
72
-
-
0034456080
-
Foodborne listeriosis
-
Schlech,W.F., III. Foodborne listeriosis. Clin. Infect. Dis. 31:770-775, 2000.
-
(2000)
Clin. Infect. Dis
, vol.31
, pp. 770-775
-
-
Schlech, W.F.1
-
73
-
-
0032810172
-
Methodology for detection and typing of foodborne microorganisms
-
De Boer, E., R.R. Beumer. Methodology for detection and typing of foodborne microorganisms. Int. J. Food. Microbiol. (50):119-130, 1999.
-
(1999)
Int. J. Food. Microbiol
, Issue.50
, pp. 119-130
-
-
De Boer, E.1
Beumer, R.R.2
-
74
-
-
2242487518
-
Detecting Listeria monocytogenes in food
-
Artault, S., J.L. Blind, J. Delaval, Y. Dureuil, N. Gaillard. Detecting Listeria monocytogenes in food. Int. Food. Hyg. 12(3):23, 2001.
-
(2001)
Int. Food. Hyg
, vol.12
, Issue.3
, pp. 23
-
-
Artault, S.1
Blind, J.L.2
Delaval, J.3
Dureuil, Y.4
Gaillard, N.5
-
75
-
-
0032828437
-
PCR and the detection of microbial pathogens in water and wastewater
-
Toze, S. PCR and the detection of microbial pathogens in water and wastewater. Water Res. 33:3545-3556, 1999.
-
(1999)
Water Res
, vol.33
, pp. 3545-3556
-
-
Toze, S.1
-
76
-
-
0028442744
-
Food safety applications of nucleic acid-based assays
-
Bsat, N., M. Weidmenn, J. Czajka, F. Barany, M. Piani, C.A. Batt. Food safety applications of nucleic acid-based assays. Food Technol. 48:142-145, 1994.
-
(1994)
Food Technol
, vol.48
, pp. 142-145
-
-
Bsat, N.1
Weidmenn, M.2
Czajka, J.3
Barany, F.4
Piani, M.5
Batt, C.A.6
-
77
-
-
2242432760
-
Immunoaffinity concentration and purification of waterborne enteric viruses for detection by reverse transcriptase PCR
-
Schwab, K.J., R. De Leon, M.D. Sobsey. Immunoaffinity concentration and purification of waterborne enteric viruses for detection by reverse transcriptase PCR. Appl. Environ. Microbiol. 63:4401-4407, 1996.
-
(1996)
Appl. Environ. Microbiol
, vol.63
, pp. 4401-4407
-
-
Schwab, K.J.1
De Leon, R.2
Sobsey, M.D.3
-
78
-
-
0027461618
-
Rapid identification of bacteria on the basis of poly-merase chain reaction-amplified ribosomal DNA spacer polymorphisms
-
Jensen, M., J.A. Webster, N. Straus. Rapid identification of bacteria on the basis of poly-merase chain reaction-amplified ribosomal DNA spacer polymorphisms. Appl. Environ. Microbiol. 59:945-52, 1993.
-
(1993)
Appl. Environ. Microbiol
, vol.59
, pp. 945-952
-
-
Jensen, M.1
Webster, J.A.2
Straus, N.3
-
79
-
-
0031035648
-
Comparison of primers and optimization of PCR conditions for detection of Crypotosporidium parvum and Giardia lamblia in water
-
Rochelle, P.A., R. De Leon, M.H. Stewart, R.L. Wolfe. Comparison of primers and optimization of PCR conditions for detection of Crypotosporidium parvum and Giardia lamblia in water. Appl. Environ. Microbiol. 63:106-114, 1997.
-
(1997)
Appl. Environ. Microbiol
, vol.63
, pp. 106-114
-
-
Rochelle, P.A.1
De Leon, R.2
Stewart, M.H.3
Wolfe, R.L.4
-
80
-
-
0029818576
-
Approaching helminth biology from the molecular direction
-
Geary, T.G. Approaching helminth biology from the molecular direction. Parasitol. Today 12:373-375, 1996.
-
(1996)
Parasitol. Today
, vol.12
, pp. 373-375
-
-
Geary, T.G.1
-
81
-
-
0000150675
-
Continuous cultures of fused cells secreting antibody of predefined specificity
-
Köhler, G., C. Milstein. Continuous cultures of fused cells secreting antibody of predefined specificity. Nature 310:792-794, 1975.
-
(1975)
Nature
, vol.310
, pp. 792-794
-
-
Köhler, G.1
Milstein, C.2
-
82
-
-
0034351350
-
A review of molecular recognition technologies for detection of biological threat agents
-
Iqbal, S.S., M.W. Mayo, J.G. Bruno, B.V. Bronk, C.A. Batt, P. Chambers. A review of molecular recognition technologies for detection of biological threat agents. Biosens. Bioelectron. 15:549-578, 2000.
-
(2000)
Biosens. Bioelectron
, vol.15
, pp. 549-578
-
-
Iqbal, S.S.1
Mayo, M.W.2
Bruno, J.G.3
Bronk, B.V.4
Batt, C.A.5
Chambers, P.6
-
83
-
-
2042487157
-
-
Hauck, S., C. Kosslinger, S. Drost, H. Wolf. Lebensmittelchemie 52:158-167, 1998.
-
(1998)
Lebensmittelchemie
, vol.52
, pp. 158-167
-
-
Hauck, S.1
Kosslinger, C.2
Drost, S.3
Wolf, H.4
-
85
-
-
85133982582
-
A planar indium phosphate monomode waveguide evanescent field immunosensor
-
Sloper, A.N., J.K. Deacon, M.T. Flannagan. A planar indium phosphate monomode waveguide evanescent field immunosensor. Sens. Actuators B. 1:285-297, 2001.
-
(2001)
Sens. Actuators B
, vol.1
, pp. 285-297
-
-
Sloper, A.N.1
Deacon, J.K.2
Flannagan, M.T.3
-
86
-
-
0025649114
-
Immunoassay and nucleic acid detection with a biosensor based on surface plasmon resonance
-
Pollard-Knight, D.V., E. Hawkins, D. Yeung, D.P. Paswhby, M. Simpson, A. McDougall, P. Buckle, S.A. Charles. Immunoassay and nucleic acid detection with a biosensor based on surface plasmon resonance. Ann. Biol. Clin. 48:642-646, 1990.
-
(1990)
Ann. Biol. Clin
, vol.48
, pp. 642-646
-
-
Pollard-Knight, D.V.1
Hawkins, E.2
Yeung, D.3
Paswhby, D.P.4
Simpson, M.5
McDougall, A.6
Buckle, P.7
Charles, S.A.8
-
87
-
-
0025876152
-
Kinetic analysis of monoclonal antibody-antigen interactions with a new biosensor based analytical system
-
Karlsson, R., A. Michaelsson, L. Mattsson. Kinetic analysis of monoclonal antibody-antigen interactions with a new biosensor based analytical system J. Immunol. Meth. 145:229-240, 1991.
-
(1991)
J. Immunol. Meth
, vol.145
, pp. 229-240
-
-
Karlsson, R.1
Michaelsson, A.2
Mattsson, L.3
-
88
-
-
0026768221
-
Detection of receptor ligand interactions using surface plasmon resonance: Model studies employing the HIV-1 GP120/CD4 interactions
-
Brigham-Burke, M., J.R. Edwards, D.J. O'Shannessy. Detection of receptor ligand interactions using surface plasmon resonance: model studies employing the HIV-1 GP120/CD4 interactions. J. Anal. Biochem. 205:125-131, 1992.
-
(1992)
J. Anal. Biochem
, vol.205
, pp. 125-131
-
-
Brigham-Burke, M.1
Edwards, J.R.2
O'Shannessy, D.J.3
-
89
-
-
0030988945
-
Real time analysis of antibody binding interactions with immobilized E.coli 0157:H7 cells using the BIAcore
-
Medina, M.B., L. Van Houten, P. Cooke, S.I. Tu. Real time analysis of antibody binding interactions with immobilized E.coli 0157:H7 cells using the BIAcore. Biotechnol. Tech. 11(3):173-176, 1997.
-
(1997)
Biotechnol. Tech
, vol.11
, Issue.3
, pp. 173-176
-
-
Medina, M.B.1
Van Houten, L.2
Cooke, P.3
Tu, S.I.4
-
90
-
-
0031872669
-
Detection of Escherichia coli 0157:H7 using a surface plasmon resonance biosensor
-
Fratamico, P.M., T.P. Strobaugh, M.B. Medina, A.G. Gehring. Detection of Escherichia coli 0157:H7 using a surface plasmon resonance biosensor. Biotechnol. Tech. 12(7):571-576, 1998.
-
(1998)
Biotechnol. Tech
, vol.12
, Issue.7
, pp. 571-576
-
-
Fratamico, P.M.1
Strobaugh, T.P.2
Medina, M.B.3
Gehring, A.G.4
-
91
-
-
0025874066
-
Electrochemical detection of viable bacteria in urine and antibiotic selection
-
Nakamura, N., A. Shigematsu, T. Matsunaga. Electrochemical detection of viable bacteria in urine and antibiotic selection. Biosens. Bioelectron. 6(7):575-580, 1991.
-
(1991)
Biosens. Bioelectron
, vol.6
, Issue.7
, pp. 575-580
-
-
Nakamura, N.1
Shigematsu, A.2
Matsunaga, T.3
-
92
-
-
0030766396
-
Hartman interferometer: Versatile integrated optic sensor for label-free, real time quantification of nucleic acids, proteins and pathogens
-
Schneider, B.H., J.G. Edwards, N.F. Hartman. Hartman interferometer: versatile integrated optic sensor for label-free, real time quantification of nucleic acids, proteins and pathogens. Clin. Chem. 43(9):1757-1763, 1997.
-
(1997)
Clin. Chem
, vol.43
, Issue.9
, pp. 1757-1763
-
-
Schneider, B.H.1
Edwards, J.G.2
Hartman, N.F.3
-
93
-
-
0027396036
-
A rapid luminescent phage-based MPN method for the enumeration of Salmonella typhimurium in environmental samples
-
Turpin, P.E., K.A. Maycroft, J. Bedford, C.L. Rowlands, E.M.H. Wellington. A rapid luminescent phage-based MPN method for the enumeration of Salmonella typhimurium in environmental samples. Lett. Appl. Microbiol. 16:24-27, 1993.
-
(1993)
Lett. Appl. Microbiol
, vol.16
, pp. 24-27
-
-
Turpin, P.E.1
Maycroft, K.A.2
Bedford, J.3
Rowlands, C.L.4
Wellington, E.M.H.5
-
94
-
-
0029818119
-
Salmonella detection in eggs using lux bacteriophages
-
Chen, J., M.W. Griffiths. Salmonella detection in eggs using lux bacteriophages. J. Food Protect. 59:908-914, 1996.
-
(1996)
J. Food Protect
, vol.59
, pp. 908-914
-
-
Chen, J.1
Griffiths, M.W.2
-
95
-
-
0029930408
-
Construction of luciferase reporter bacteriophage A511:lux AB for rapid and sensitive detection of viable Listeria cells
-
Loessner, M.J., C.E.D. Rees, G.S.A.B. Stewart, S. Scherer. Construction of luciferase reporter bacteriophage A511:lux AB for rapid and sensitive detection of viable Listeria cells. Appl. Environ. Microbiol. 62:1133-1140, 1996.
-
(1996)
Appl. Environ. Microbiol
, vol.62
, pp. 1133-1140
-
-
Loessner, M.J.1
Rees, C.E.D.2
Stewart, G.S.A.B.3
Scherer, S.4
-
96
-
-
0031801703
-
Specific assays for bacteria using phage mediated release of adenylate kinase
-
Blasco, R., M.J. Murphy, M.F. Sanders, D.J. Squirrell. Specific assays for bacteria using phage mediated release of adenylate kinase. J. Appl. Microbiol. 84:661-666, 1998.
-
(1998)
J. Appl. Microbiol
, vol.84
, pp. 661-666
-
-
Blasco, R.1
Murphy, M.J.2
Sanders, M.F.3
Squirrell, D.J.4
-
97
-
-
0030030001
-
Determination of microorganisms with a quartz crystal microbalance sensor
-
Bao, L., L. Deng, L. Nie, S. Yao, W. Wie. Determination of microorganisms with a quartz crystal microbalance sensor. Anal. Chim. Acta 319:97-101, 1996.
-
(1996)
Anal. Chim. Acta
, vol.319
, pp. 97-101
-
-
Bao, L.1
Deng, L.2
Nie, L.3
Yao, S.4
Wie, W.5
-
98
-
-
0030006268
-
Microbial Detection
-
Hobson, N.S., I. Tothill, A.P.F. Turner. Microbial Detection. Biosens. Bioelectron. 11(5):455-477, 1996.
-
(1996)
Biosens. Bioelectron
, vol.11
, Issue.5
, pp. 455-477
-
-
Hobson, N.S.1
Tothill, I.2
Turner, A.P.F.3
-
99
-
-
0001287053
-
Piezoelectric immunosensor for the detection of Candida albicans microbes
-
Muramatsu, H., K. Kajiwara, E. Tamiya, I. Karube. Piezoelectric immunosensor for the detection of Candida albicans microbes. Anal. Chim. Acta 188:257-261, 1986.
-
(1986)
Anal. Chim. Acta
, vol.188
, pp. 257-261
-
-
Muramatsu, H.1
Kajiwara, K.2
Tamiya, E.3
Karube, I.4
-
101
-
-
0036189726
-
Piezoelectric flow injection analysis biosensor for the detection of
-
Babacan, S., P. Pivarnick, S. Letcher, A. Rand. Piezoelectric flow injection analysis biosensor for the detection of Salmonella typhimurium. J. Food Sci. 67(1):314-320, 2002.
-
(2002)
Salmonella typhimurium. J. Food Sci
, vol.67
, Issue.1
, pp. 314-320
-
-
Babacan, S.1
Pivarnick, P.2
Letcher, S.3
Rand, A.4
-
102
-
-
0029345735
-
A piezoelectric biosensor for
-
Jacobs, M.B., R.M. Cater, G.J. Lubrano, G.G. Guilbault. A piezoelectric biosensor for Listeria monocytogenes. Am. Lab. 27(11):26-28, 1995.
-
(1995)
Listeria monocytogenes. Am. Lab
, vol.27
, Issue.11
, pp. 26-28
-
-
Jacobs, M.B.1
Cater, R.M.2
Lubrano, G.J.3
Guilbault, G.G.4
-
103
-
-
84865280983
-
Detection of viruses and bacteria with piezoelectric immunosensors
-
Koenig, B., M. Gratzel. Detection of viruses and bacteria with piezoelectric immunosensors. Anal. Lett. 26(8):1567-1585, 1993.
-
(1993)
Anal. Lett
, vol.26
, Issue.8
, pp. 1567-1585
-
-
Koenig, B.1
Gratzel, M.2
-
104
-
-
15444356204
-
Piezoelectric biosensor for detection of
-
Ye, J.M., S.V. Letcher, A.G. Rand. Piezoelectric biosensor for detection of Salmonella typhimurium. J. Food Sci. 62(5):1067-1072, 1997.
-
(1997)
Salmonella typhimurium. J. Food Sci
, vol.62
, Issue.5
, pp. 1067-1072
-
-
Ye, J.M.1
Letcher, S.V.2
Rand, A.G.3
-
105
-
-
0030865852
-
Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor
-
Harteveld, J.L.N., M.S. Nieuwenhuizen, E.R.J. Wils. Detection of Staphylococcal Enterotoxin B employing a piezoelectric crystal immunosensor. Biosens. Bioelectron. 12:661-667, 1997.
-
(1997)
Biosens. Bioelectron
, vol.12
, pp. 661-667
-
-
Harteveld, J.L.N.1
Nieuwenhuizen, M.S.2
Wils, E.R.J.3
-
106
-
-
0034256062
-
A DNA piezoelectric biosensor assay coupled with a polymerase chain reaction for bacterial toxicity determination in environmental samples
-
Tombelli, S., M. Mascini, C. Sacco, A.P.F. Turner. A DNA piezoelectric biosensor assay coupled with a polymerase chain reaction for bacterial toxicity determination in environmental samples. Anal. Chim. Acta 418:1-9, 2001.
-
(2001)
Anal. Chim. Acta
, vol.418
, pp. 1-9
-
-
Tombelli, S.1
Mascini, M.2
Sacco, C.3
Turner, A.P.F.4
-
107
-
-
0001287053
-
Piezoelectric immunosensor for the detection of Candida albicans microbes
-
Maramatsu, H., K. Kajiwara, E. Tamiya, I. Karube. Piezoelectric immunosensor for the detection of Candida albicans microbes. Anal. Chim. Acta 188:257-261, 1986.
-
(1986)
Anal. Chim. Acta
, vol.188
, pp. 257-261
-
-
Maramatsu, H.1
Kajiwara, K.2
Tamiya, E.3
Karube, I.4
-
108
-
-
0029345735
-
A piezoelectric biosensor for
-
Jacobs, M.B., R.M. Cater, G.J. Lubrano, G.G. Guilbault. A piezoelectric biosensor for Listeria monocytogenes. Am. Lab. 27(11):26-28, 1995.
-
(1995)
Listeria monocytogenes. Am. Lab
, vol.27
, Issue.11
, pp. 26-28
-
-
Jacobs, M.B.1
Cater, R.M.2
Lubrano, G.J.3
Guilbault, G.G.4
-
110
-
-
0028785980
-
Quartz crystal microbalance detection of Vibro cholerae 0139 serotype
-
Cater, R.M., J.J. Mekalanos, M.B. Jacobs, G.J. Lubrano, G.G. Guilbault. Quartz crystal microbalance detection of Vibro cholerae 0139 serotype. J. Immunol. Methods 187:121-125, 1995.
-
(1995)
J. Immunol. Methods
, vol.187
, pp. 121-125
-
-
Cater, R.M.1
Mekalanos, J.J.2
Jacobs, M.B.3
Lubrano, G.J.4
Guilbault, G.G.5
-
111
-
-
0035971749
-
Piezoelectric quartz crystal based veterinary diagnosis for Salmonella enteritidis infection in chicken and egg
-
Su, X., S. Low, J. Kwang, V.H.T. Chew, S.F.Y. Li. Piezoelectric quartz crystal based veterinary diagnosis for Salmonella enteritidis infection in chicken and egg. Sens. Actuators B. 75:29-35, 2001.
-
(2001)
Sens. Actuators B
, vol.75
, pp. 29-35
-
-
Su, X.1
Low, S.2
Kwang, J.3
Chew, V.H.T.4
Li, S.F.Y.5
-
112
-
-
0030576967
-
Enzyme-linked immunomagnetic electrochemical detection of
-
Gehring, A.G., C.G. Crawford, R.S. Mazenko, L.J. Van Houten, J.D. Brewster. Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium. J. Immunol. Methods 195:15-25, 1996.
-
(1996)
Salmonella typhimurium. J. Immunol. Methods
, vol.195
, pp. 15-25
-
-
Gehring, A.G.1
Crawford, C.G.2
Mazenko, R.S.3
Van Houten, L.J.4
Brewster, J.D.5
-
113
-
-
0031020389
-
Towards amperometric immunosensor devices
-
Tiefenauer, L.X., S. Kossek, C. Padeste, P. Thiébaud. Towards amperometric immunosensor devices. Biosens. Bioelectron. 12(3):213-223, 1997.
-
(1997)
Biosens. Bioelectron
, vol.12
, Issue.3
, pp. 213-223
-
-
Tiefenauer, L.X.1
Kossek, S.2
Padeste, C.3
Thiébaud, P.4
-
114
-
-
0025201260
-
A semi-homogeneous amperometric immunosensor for protein A-bearing Staphylococcus aureus in foods
-
Mirhabibollahi, B., J.L. Brooks, R.G. Krool. A semi-homogeneous amperometric immunosensor for protein A-bearing Staphylococcus aureus in foods. Appl. Microb. Biotechnol. 34:242-247, 1990.
-
(1990)
Appl. Microb. Biotechnol
, vol.34
, pp. 242-247
-
-
Mirhabibollahi, B.1
Brooks, J.L.2
Krool, R.G.3
-
115
-
-
0028868170
-
A novel liposome based electrochemical biosensor for the detection of haemolytic microorganisms
-
H.J. Kim, H.P. Bennetto, M.A. Halablab. A novel liposome based electrochemical biosensor for the detection of haemolytic microorganisms. Biotechnol. Tech. 9(6):389-394, 1995.
-
(1995)
Biotechnol. Tech
, vol.9
, Issue.6
, pp. 389-394
-
-
Kim, H.J.1
Bennetto, H.P.2
Halablab, M.A.3
-
116
-
-
0032004074
-
Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli 0157:H7
-
Brewster, J.D., R.S. Mazenko. Filtration capture and immunoelectrochemical detection for rapid assay of Escherichia coli 0157:H7. J. Immunol. Methods 211:1-8, 1998.
-
(1998)
J. Immunol. Methods
, vol.211
, pp. 1-8
-
-
Brewster, J.D.1
Mazenko, R.S.2
-
117
-
-
0031026620
-
An amperometric enzyme-channeling immunosensor
-
Rishpon, J., D. Ivnitski. An amperometric enzyme-channeling immunosensor. Biosens. Bioelectron. 12(2):195-204, 1997.
-
(1997)
Biosens. Bioelectron
, vol.12
, Issue.2
, pp. 195-204
-
-
Rishpon, J.1
Ivnitski, D.2
-
118
-
-
0033833996
-
Electrochemical biosensor based on supported planar lipid bilayers for fast detection of pathogenic bacteria
-
Ivnitski, D., E. Wilkins, H.T. Tien, A. Ottova. Electrochemical biosensor based on supported planar lipid bilayers for fast detection of pathogenic bacteria. ELECOM 2:457-460, 2000.
-
(2000)
ELECOM
, vol.2
, pp. 457-460
-
-
Ivnitski, D.1
Wilkins, E.2
Tien, H.T.3
Ottova, A.4
-
119
-
-
0037414731
-
Coupling conducting polymers and mediated electrochemical responses for the detection of
-
Minett, A.I., J.N. Barisci, G.G. Wallace. Coupling conducting polymers and mediated electrochemical responses for the detection of Listeria. Anal. Chim. Acta 475(1-2):37-45, 2003.
-
(2003)
Listeria. Anal. Chim. Acta
, vol.475
, Issue.1-2
, pp. 37-45
-
-
Minett, A.I.1
Barisci, J.N.2
Wallace, G.G.3
-
120
-
-
0642340797
-
RNA biosensor for the rapid detection of viable Escherichia coli in drinking water
-
Baeumner, A.J., R.N. Cohen, V. Miksic, J. Min. RNA biosensor for the rapid detection of viable Escherichia coli in drinking water. Biosens. Bioelectron. 18(4):405-413, 2003.
-
(2003)
Biosens. Bioelectron
, vol.18
, Issue.4
, pp. 405-413
-
-
Baeumner, A.J.1
Cohen, R.N.2
Miksic, V.3
Min, J.4
-
121
-
-
0037067111
-
Direct selective detection of genomic DNA from coliform using a fiber optic biosensor
-
Almadidy, A., J. Watterson, P.A.E. Piunno, S. Raha, I.V. Foulds, P.A. Horgen, A. Castle, U. Krull. Direct selective detection of genomic DNA from coliform using a fiber optic biosensor. Anal. Chim. Acta 461(1):37-47, 2002.
-
(2002)
Anal. Chim. Acta
, vol.461
, Issue.1
, pp. 37-47
-
-
Almadidy, A.1
Watterson, J.2
Piunno, P.A.E.3
Raha, S.4
Foulds, I.V.5
Horgen, P.A.6
Castle, A.7
Krull, U.8
-
122
-
-
0037178192
-
A miniature fiber optic surface plasmon resonance sensor for fast detection of staphylococcal enterotoxin B
-
Slavík, R., J. Homola, E. Brynda. A miniature fiber optic surface plasmon resonance sensor for fast detection of staphylococcal enterotoxin B. Biosens. Bioelectron. 17(6-7):591-595, 2002.
-
(2002)
Biosens. Bioelectron
, vol.17
, Issue.6-7
, pp. 591-595
-
-
Slavík, R.1
Homola, J.2
Brynda, E.3
-
123
-
-
1842835762
-
Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organism (GMOs) detection
-
Mannelli, I., M. Minunni, S. Tombelli M. Mascini. Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organism (GMOs) detection. Biosens. Bioelectron. 18:129-140, 2003.
-
(2003)
Biosens. Bioelectron
, vol.18
, pp. 129-140
-
-
Mannelli, I.1
Minunni, M.2
Tombelli, S.3
Mascini, M.4
-
124
-
-
0027050755
-
Control of microbial activity by flow injection analysis during high cell density cultivation of
-
Ding, T., U. Bilitewski, R.D. Schmid, D.J. Korz, E.A. Sanders. Control of microbial activity by flow injection analysis during high cell density cultivation of E. coli. J. Biotechnol. 27:143-157, 1993.
-
(1993)
E. coli. J. Biotechnol
, vol.27
, pp. 143-157
-
-
Ding, T.1
Bilitewski, U.2
Schmid, R.D.3
Korz, D.J.4
Sanders, E.A.5
-
125
-
-
43949163527
-
Mediated electrocatalysis at biocatalyst electrode based on a bacterium luconobacter industrius
-
Takayama, K., T. Kurosaki, T. Ikeda. Mediated electrocatalysis at biocatalyst electrode based on a bacterium luconobacter industrius. J. Electroanal. Chem. 356:295-301, 1993.
-
(1993)
J. Electroanal. Chem
, vol.356
, pp. 295-301
-
-
Takayama, K.1
Kurosaki, T.2
Ikeda, T.3
-
126
-
-
0030576967
-
Enzyme-linked immunomagnetic electrochemical detection of
-
Gehring, A.G., C.G. Crawford, R.S. Mazenko, L.J. Van Houten, J.D. Brewster. Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium. J. Immunol. Methods 195:15-25, 1996.
-
(1996)
Salmonella typhimurium. J. Immunol. Methods
, vol.195
, pp. 15-25
-
-
Gehring, A.G.1
Crawford, C.G.2
Mazenko, R.S.3
Van Houten, L.J.4
Brewster, J.D.5
-
127
-
-
0032089052
-
Immunomagnetic separation with mediated flow-injection analysis amperometric detection of viable E. coli O157
-
Perez, F.G., M. Mascini, I.E. Tothill, A.P.F. Turner. Immunomagnetic separation with mediated flow-injection analysis amperometric detection of viable E. coli O157. Anal. Chem. 70:2380-2386, 1998.
-
(1998)
Anal. Chem
, vol.70
, pp. 2380-2386
-
-
Perez, F.G.1
Mascini, M.2
Tothill, I.E.3
Turner, A.P.F.4
-
128
-
-
0034994845
-
Biosensors for direct determination of organophosphate pesticides
-
Mulchandani, A., W. Chen, P. Mulchandani, J. Wang, K.R. Rogers. Biosensors for direct determination of organophosphate pesticides. Biosens. Bioelectron. 16:225-230, 2001.
-
(2001)
Biosens. Bioelectron
, vol.16
, pp. 225-230
-
-
Mulchandani, A.1
Chen, W.2
Mulchandani, P.3
Wang, J.4
Rogers, K.R.5
-
129
-
-
0037210445
-
Detection of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor
-
Pogačnik, L., M. Franko. Detection of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor. Biosens. Bioelectron. 18(1):1-9, 2003.
-
(2003)
Biosens. Bioelectron
, vol.18
, Issue.1
, pp. 1-9
-
-
Pogačnik, L.1
Franko, M.2
-
130
-
-
0031590953
-
Determination of anticholinesterase pesticides in real samples using a disposable biosensor
-
Palchetti, I., A. Cagnini, M. Del Carlo, C. Coppi, M. Mascini, A.P.F. Turner. Determination of anticholinesterase pesticides in real samples using a disposable biosensor. Anal. Chim. Acta 337:315-321, 1997.
-
(1997)
Anal. Chim. Acta
, vol.337
, pp. 315-321
-
-
Palchetti, I.1
Cagnini, A.2
Del Carlo, M.3
Coppi, C.4
Mascini, M.5
Turner, A.P.F.6
-
131
-
-
0345628021
-
Determination of carbamate residues in crop samples by cholinesterase-based biosensors and chromatographic techniques
-
Nunes, G.S., P. Skládal, H. Yamanaka, D. Barceló. Determination of carbamate residues in crop samples by cholinesterase-based biosensors and chromatographic techniques. Anal. Chim. Acta 362(1):59-68, 1998.
-
(1998)
Anal. Chim. Acta
, vol.362
, Issue.1
, pp. 59-68
-
-
Nunes, G.S.1
Skládal, P.2
Yamanaka, H.3
Barceló, D.4
-
132
-
-
0032834319
-
Evaluation of a highly sensitive amperometric biosensor with low cholinesterase charge immobilized on a chemically modified carbon paste electrode for trace determination of carbamates in fruit, vegetable and water samples
-
G.S. Nunes, D. Barceló, B.S. Grabaric, J.M. Díaz-Cruz, M.L. Ribeiro. Evaluation of a highly sensitive amperometric biosensor with low cholinesterase charge immobilized on a chemically modified carbon paste electrode for trace determination of carbamates in fruit, vegetable and water samples. Anal. Chim. Acta. 399(1,2):37-49, 1999.
-
(1999)
Anal. Chim. Acta
, vol.399
, Issue.1-2
, pp. 37-49
-
-
Nunes, G.S.1
Barceló, D.2
Grabaric, B.S.3
Díaz-Cruz, J.M.4
Ribeiro, M.L.5
-
133
-
-
0035979850
-
Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology
-
Albareda-Sirvent, M., A. Merkoçi, S. Alegret. Pesticide determination in tap water and juice samples using disposable amperometric biosensors made using thick-film technology. Anal. Chim. Acta 442(1):35-44, 2001.
-
(2001)
Anal. Chim. Acta
, vol.442
, Issue.1
, pp. 35-44
-
-
Albareda-Sirvent, M.1
Merkoçi, A.2
Alegret, S.3
-
134
-
-
0037021588
-
Electrochemical bio-assay for the investigation of chlorpyrifos methyl in vine samples
-
Del Carlo, M., M. Mascini, A. Pepe, D. Compagnone, M. Mascini. Electrochemical bio-assay for the investigation of chlorpyrifos methyl in vine samples. J. Agric. Food Chem. 50:7206-7210, 2002.
-
(2002)
J. Agric. Food Chem
, vol.50
, pp. 7206-7210
-
-
Del Carlo, M.1
Mascini, M.2
Pepe, A.3
Compagnone, D.4
Mascini, M.5
-
135
-
-
85133992810
-
1999/50/EC of 25 May 1999 amending Directive 91/321/EEC on infant formulae and follow-on formulae
-
No L 139, 02/06/1999
-
Commission Directive 1999/50/EC of 25 May 1999 amending Directive 91/321/EEC on infant formulae and follow-on formulae, Official Journal of the European Communities No L 139, 02/06/1999, p 29.
-
Official Journal of the European Communities
, pp. 29
-
-
-
136
-
-
0036368626
-
Rapid detection of neurotoxic insecticides in food using disposable acetylcholinesterase-biosensors and simple solvent extraction
-
Schulze, H., R.D. Schmid, T.T. Bachmann. Rapid detection of neurotoxic insecticides in food using disposable acetylcholinesterase-biosensors and simple solvent extraction. Anal. Bioanal. Chem. 372:268-272, 2002.
-
(2002)
Anal. Bioanal. Chem
, vol.372
, pp. 268-272
-
-
Schulze, H.1
Schmid, R.D.2
Bachmann, T.T.3
-
137
-
-
0036883617
-
Development, validation, and application of an acetylcholinesterase biosensor test for the direct detection of insecticide residues in infant food
-
Schulze, H., E. Scherbaum, M. Anastassiades, S. Vorlova, R.D. Schmid, T.T. Bachmann. Development, validation, and application of an acetylcholinesterase biosensor test for the direct detection of insecticide residues in infant food. Biosens. Bioelectron. 17:1095-1105, 2002.
-
(2002)
Biosens. Bioelectron
, vol.17
, pp. 1095-1105
-
-
Schulze, H.1
Scherbaum, E.2
Anastassiades, M.3
Vorlova, S.4
Schmid, R.D.5
Bachmann, T.T.6
-
138
-
-
17944373680
-
Optical biosensors: Monitoring studies of glycopeptide antibiotic fermentation using white light interference
-
Tuennemann, R., M. Mehlmann, R.D. Suessmuth, B. Buehler, S. Pelzer, W. Wohlleben, H.P. Fiedler, K.H. Wiesmueller, G. Gauglitz, G. Jung. Optical biosensors: monitoring studies of glycopeptide antibiotic fermentation using white light interference. Anal. Chem. 73(17):4313-4318, 2001.
-
(2001)
Anal. Chem
, vol.73
, Issue.17
, pp. 4313-4318
-
-
Tuennemann, R.1
Mehlmann, M.2
Suessmuth, R.D.3
Buehler, B.4
Pelzer, S.5
Wohlleben, W.6
Fiedler, H.P.7
Wiesmueller, K.H.8
Gauglitz, G.9
Jung, G.10
-
139
-
-
0033798535
-
Binding of vancomycin group antibiotics to D-Alanine and D-Lactate presenting self-assembled monolayers
-
Cooper, M.A., M.T. Fiorini, C. Abell, D.H. Williams. Binding of vancomycin group antibiotics to D-Alanine and D-Lactate presenting self-assembled monolayers. Bioorg. Med. Chem. 8(11):2609-2616, 2000.
-
(2000)
Bioorg. Med. Chem
, vol.8
, Issue.11
, pp. 2609-2616
-
-
Cooper, M.A.1
Fiorini, M.T.2
Abell, C.3
Williams, D.H.4
-
140
-
-
0035849631
-
Screening of penicillin residues in milk by a surface plasmon resonance-based biosensor assay: Comparison of chemical and enzymatic sample pre-treatment
-
Gaudin, V., J. Fontaine, P. Maris. Screening of penicillin residues in milk by a surface plasmon resonance-based biosensor assay: comparison of chemical and enzymatic sample pre-treatment. Anal. Chim. Acta 436(2):191-198, 2001.
-
(2001)
Anal. Chim. Acta
, vol.436
, Issue.2
, pp. 191-198
-
-
Gaudin, V.1
Fontaine, J.2
Maris, P.3
-
141
-
-
0037057093
-
Biosensor analysis of penicillin G in milk based on the inhibition of carboxypeptidase activity
-
Gustavsson, E., P. Bjurling, Å. Sternesjö. Biosensor analysis of penicillin G in milk based on the inhibition of carboxypeptidase activity. Anal. Chim. Acta 468(1):153-159, 2002.
-
(2002)
Anal. Chim. Acta
, vol.468
, Issue.1
, pp. 153-159
-
-
Gustavsson, E.1
Bjurling, P.2
Sternesjö, A.3
-
142
-
-
0036324581
-
Detection of streptomycin and dihydrostreptomycin residues in milk, honey and meat samples using an optical biosensor
-
Ferguson, J.P., G.A. Baxter, J.D.G. McEvoy, S. Stead, E. Rawlings, M. Sharman. Detection of streptomycin and dihydrostreptomycin residues in milk, honey and meat samples using an optical biosensor. Analyst 127:951-956, 2002.
-
(2002)
Analyst
, vol.127
, pp. 951-956
-
-
Ferguson, J.P.1
Baxter, G.A.2
McEvoy, J.D.G.3
Stead, S.4
Rawlings, E.5
Sharman, M.6
-
144
-
-
0031000343
-
Determination of organomercury compounds using immobilized peroxidase
-
Shekhovtsova, T.N., S.V. Muginova, N.A. Bagirova. Determination of organomercury compounds using immobilized peroxidase. Anal. Chim. Acta 344:145-151, 1997.
-
(1997)
Anal. Chim. Acta
, vol.344
, pp. 145-151
-
-
Shekhovtsova, T.N.1
Muginova, S.V.2
Bagirova, N.A.3
-
145
-
-
0000957536
-
Influence and role of metal ions in enzymatic catalysis with E.C. 1.2.3.2. xanthine oxidase: Application to trace analysis
-
Ghe, A.M., C. Stefanelli, D. Carati. Influence and role of metal ions in enzymatic catalysis with E.C. 1.2.3.2. xanthine oxidase: application to trace analysis. Talanta 31:241-247, 1984.
-
(1984)
Talanta
, vol.31
, pp. 241-247
-
-
Ghe, A.M.1
Stefanelli, C.2
Carati, D.3
-
146
-
-
0005375858
-
Applications of enzyme-catalysed reactions in trace analysis, I: Determination of mercury and silver by their inhibition of invertase
-
Mealor, D., A. Townshend. Applications of enzyme-catalysed reactions in trace analysis, I: determination of mercury and silver by their inhibition of invertase. Talanta 15:747-758, 1986.
-
(1986)
Talanta
, vol.15
, pp. 747-758
-
-
Mealor, D.1
Townshend, A.2
-
147
-
-
0021932463
-
An enzyme-catalysed method for the determination of mercury traces in carbonated soft drinks, by the Hg+2 inhibition of B-fructofuranosidase
-
Maslowska, J., J. Leszczynska. An enzyme-catalysed method for the determination of mercury traces in carbonated soft drinks, by the Hg+2 inhibition of B-fructofuranosidase. Talanta 32:883-886, 1985.
-
(1985)
Talanta
, vol.32
, pp. 883-886
-
-
Maslowska, J.1
Leszczynska, J.2
-
148
-
-
0029481520
-
Detection of mercury compounds using invertase-glucose oxidase-based biosensor. In: Environmental Monitoring and Hazardous Waste Remediation
-
Vo-Dinh, T., R. Niebner, eds
-
Amine, A., Cremisini, C., G. Palleschi. Detection of mercury compounds using invertase-glucose oxidase-based biosensor. In: Environmental Monitoring and Hazardous Waste Remediation, Vo-Dinh, T., R. Niebner, eds., SPIE Ser. 2504:209-220, 1995.
-
(1995)
SPIE Ser
, vol.2504
, pp. 209-220
-
-
Amine, A.1
Cremisini, C.2
Palleschi, G.3
-
149
-
-
0024386793
-
A prospect for the analysis of species acting as enzyme inhibitors as illustrated by heavy metal inhibition
-
Donlan, A.M., G.J. Moody, J.D.R. Thomas. A prospect for the analysis of species acting as enzyme inhibitors as illustrated by heavy metal inhibition. Anal. Lett. 22:1873-1896, 1989.
-
(1989)
Anal. Lett
, vol.22
, pp. 1873-1896
-
-
Donlan, A.M.1
Moody, G.J.2
Thomas, J.D.R.3
-
150
-
-
0026645812
-
A new enzyme inhibition sensor for organophosphorus pesticides analysis
-
Campanella, L., R. Cocco, M.P. Sammartino, M. Tomassetti. A new enzyme inhibition sensor for organophosphorus pesticides analysis. Sci. Total Environ. 123(124):1-16, 1992.
-
(1992)
Sci. Total Environ
, vol.123
, Issue.124
, pp. 1-16
-
-
Campanella, L.1
Cocco, R.2
Sammartino, M.P.3
Tomassetti, M.4
-
151
-
-
33947334239
-
Effect of metals on the activation and inhibition of isocitric dehydrogenase
-
Kratochvil, B., S.L. Boyer, G.P. Hicks. Effect of metals on the activation and inhibition of isocitric dehydrogenase. Anal. Chem. 39:45-51, 1967.
-
(1967)
Anal. Chem
, vol.39
, pp. 45-51
-
-
Kratochvil, B.1
Boyer, S.L.2
Hicks, G.P.3
-
152
-
-
0032185791
-
Detection of heavy metal ions at femtomolar levels using proteinbased biosensors
-
Bontidean, I., C. Berggren, G. Johansson, E. Csöregi, B. Mattiasson, J.R. Lloyd, K.J. Jakeman, N.L. Brown. Detection of heavy metal ions at femtomolar levels using proteinbased biosensors. Anal. Chem. 12(70):4162-4169, 1998.
-
(1998)
Anal. Chem
, vol.12
, Issue.70
, pp. 4162-4169
-
-
Bontidean, I.1
Berggren, C.2
Johansson, G.3
Csöregi, E.4
Mattiasson, B.5
Lloyd, J.R.6
Jakeman, K.J.7
Brown, N.L.8
-
153
-
-
85133998092
-
-
http://www.cranfield.ac.uk
-
-
-
-
154
-
-
0030756407
-
Developments and applications of biosensors in food analysis
-
Luong, J.H.T., P. Bouvrete, K.B. Male. Developments and applications of biosensors in food analysis. TIBTECH 15:369-377, 1997.
-
(1997)
TIBTECH
, vol.15
, pp. 369-377
-
-
Luong, J.H.T.1
Bouvrete, P.2
Male, K.B.3
|