메뉴 건너뛰기




Volumn 14, Issue 5, 1999, Pages 505-513

Graphite-Teflon composite bienzyme electrodes for the determination of L-lactate: Application to food samples

Author keywords

Composite enzyme electrodes; Food; Graphite Teflon; L lactate

Indexed keywords

COMPOSITE MATERIALS; ENZYMES; FOOD PRODUCTS; GRAPHITE; MICROELECTRODES; ORGANIC ACIDS; PH; POLYTETRAFLUOROETHYLENES; PROTEINS; WINE;

EID: 0033620592     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(99)00022-6     Document Type: Article
Times cited : (89)

References (18)
  • 2
    • 0031943860 scopus 로고    scopus 로고
    • Development of a bienzymatic Graphite-Teflon composite electrode for the determination of hypoxanthine in fish
    • Cayuela G., Pena N., Reviejo A.J., Pingarron J.M. Development of a bienzymatic Graphite-Teflon composite electrode for the determination of hypoxanthine in fish. The Analyst. 123:1998;371-377.
    • (1998) The Analyst , vol.123 , pp. 371-377
    • Cayuela, G.1    Pena, N.2    Reviejo, A.J.3    Pingarron, J.M.4
  • 3
    • 0000064956 scopus 로고    scopus 로고
    • Graphite-Teflon-peroxidase electrodes: Application to the direct determination of glucose in musts and wines
    • del Cerro M.A., Cayuela G., Reviejo A.J., Pingarron J.M. Graphite-Teflon-peroxidase electrodes: application to the direct determination of glucose in musts and wines. Electroanalysis. 9:1997;1113-1119.
    • (1997) Electroanalysis , vol.9 , pp. 1113-1119
    • Del Cerro, M.A.1    Cayuela, G.2    Reviejo, A.J.3    Pingarron, J.M.4
  • 5
    • 0002380336 scopus 로고    scopus 로고
    • Electrochemical biosensors for assays of L-malic and D-lactic acids in wines
    • Gilis H., Durliat H., Comtat M. Electrochemical biosensors for assays of L-malic and D-lactic acids in wines. Am. J. Enol. Vitic. 47:1996;11.
    • (1996) Am. J. Enol. Vitic. , vol.47 , pp. 11
    • Gilis, H.1    Durliat, H.2    Comtat, M.3
  • 9
    • 0000072440 scopus 로고    scopus 로고
    • Design of enzyme electrodes for extended use and storage life
    • Khan G.F., Wernet W. Design of enzyme electrodes for extended use and storage life. Anal. Chem. 69:1997;2682-2687.
    • (1997) Anal. Chem. , vol.69 , pp. 2682-2687
    • Khan, G.F.1    Wernet, W.2
  • 10
    • 0030739976 scopus 로고    scopus 로고
    • A bienzyme-poly-(o-phenylenediamine)-modified carbon paste electrode for the amperometric detection of L-lactate
    • Lobo-Castanon M.J., Miranda-Ordieres A.J., Tunon-Blanco P. A bienzyme-poly-(o-phenylenediamine)-modified carbon paste electrode for the amperometric detection of L-lactate. Anal. Chim. Acta. 346:1997;165-174.
    • (1997) Anal. Chim. Acta , vol.346 , pp. 165-174
    • Lobo-Castanon, M.J.1    Miranda-Ordieres, A.J.2    Tunon-Blanco, P.3
  • 11
    • 0030271629 scopus 로고    scopus 로고
    • Flow injection analysis of L-lactic acid using an enzyme-poly-ion complex coated electrode as the detector
    • Mizutani F., Yabuki S., Hirata Y. Flow injection analysis of L-lactic acid using an enzyme-poly-ion complex coated electrode as the detector. Talanta. 43:1996;1815-1820.
    • (1996) Talanta , vol.43 , pp. 1815-1820
    • Mizutani, F.1    Yabuki, S.2    Hirata, Y.3
  • 12
    • 0031234222 scopus 로고    scopus 로고
    • Graphite-Teflon composite enzyme electrodes as suitable biosensors in predominantly non-aqueous media
    • Ortiz G., Gonzalez M.C., Reviejo M.J., Pingarron J.M. Graphite-Teflon composite enzyme electrodes as suitable biosensors in predominantly non-aqueous media. Anal. Chem. 69:1997;3521-3526.
    • (1997) Anal. Chem. , vol.69 , pp. 3521-3526
    • Ortiz, G.1    Gonzalez, M.C.2    Reviejo, M.J.3    Pingarron, J.M.4
  • 14
    • 0030030872 scopus 로고    scopus 로고
    • A bienzyme modified carbon paste electrode for the amperometric detection of L-lactate at low potentials
    • Spohn U., Narasaiah D., Pfeiffer D., Gorton L. A bienzyme modified carbon paste electrode for the amperometric detection of L-lactate at low potentials. Anal. Chim. Acta. 319:1996;79-90.
    • (1996) Anal. Chim. Acta , vol.319 , pp. 79-90
    • Spohn, U.1    Narasaiah, D.2    Pfeiffer, D.3    Gorton, L.4
  • 15
    • 0030617170 scopus 로고    scopus 로고
    • Detection of silage effluent pollution in river water using biosensors
    • Stephens S.K., Tothill I.E., Warner P.J., Turner A.P.F. Detection of silage effluent pollution in river water using biosensors. Wat. Res. 31(1):1997;41-48.
    • (1997) Wat. Res. , vol.31 , Issue.1 , pp. 41-48
    • Stephens, S.K.1    Tothill, I.E.2    Warner, P.J.3    Turner, A.P.F.4
  • 16
    • 0022090237 scopus 로고
    • Improved on-line stripping voltammetry using a large volume wall-jet detector
    • Wang J., Freiha B. Improved on-line stripping voltammetry using a large volume wall-jet detector. Anal. Chem. 47:1985;1776-1778.
    • (1985) Anal. Chem. , vol.47 , pp. 1776-1778
    • Wang, J.1    Freiha, B.2
  • 18
    • 0343369138 scopus 로고
    • Simultaneous determination of L(+)- And D(-)-lactic acid by use of immobilized enzymes in a flow-injection system
    • Yao T., Wasa T. Simultaneous determination of L(+)- and D(-)-lactic acid by use of immobilized enzymes in a flow-injection system. Anal. Chim. Acta. 175:1985;301-304.
    • (1985) Anal. Chim. Acta , vol.175 , pp. 301-304
    • Yao, T.1    Wasa, T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.