메뉴 건너뛰기




Volumn 91, Issue 1-3, 2003, Pages 195-198

Flow injection analysis of acetic acid in food samples by using trienzyme/poly(dimethylsiloxane)-bilayer membrane-based electrode as the detector

Author keywords

Acetic acid; Amperometric sensor; Flow injection analysis; Food samples

Indexed keywords

AMPEROMETRIC SENSORS; CATALYSIS; ELECTRODES; ENZYME IMMOBILIZATION; ENZYMES; FOOD PRODUCTS; OXYGEN; PHOSPHORS; POLYMERIC MEMBRANES; SENSORS;

EID: 12444326802     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(03)00088-1     Document Type: Article
Times cited : (18)

References (16)
  • 1
    • 0016475946 scopus 로고
    • Amperometric determination of alcohols, aldehydes and carboxylic acids with an immobilized alcohol oxidase enzyme electrode
    • Nanjo M., Guilbault G.G. Amperometric determination of alcohols, aldehydes and carboxylic acids with an immobilized alcohol oxidase enzyme electrode. Anal. Chim. Acta. 75:1975;169.
    • (1975) Anal. Chim. Acta , vol.75 , pp. 169
    • Nanjo, M.1    Guilbault, G.G.2
  • 2
    • 0002608210 scopus 로고
    • Amperometric determination of acetic acid with immobilized Trichosporon brassicae
    • Hikuma M., Kubo T., Yasuda T., Karube I., Suzuki S. Amperometric determination of acetic acid with immobilized Trichosporon brassicae. Anal. Chim. Acta. 109:1979;33.
    • (1979) Anal. Chim. Acta , vol.109 , pp. 33
    • Hikuma, M.1    Kubo, T.2    Yasuda, T.3    Karube, I.4    Suzuki, S.5
  • 3
    • 0035638284 scopus 로고    scopus 로고
    • An interference-free, amperometric biosensor for acetic acid based on a trienzyme/polydimethylsiloxane-bilayer membrane
    • F. Mizutani, T. Sawaguchi, S. Iijima, An interference-free, amperometric biosensor for acetic acid based on a trienzyme/polydimethylsiloxane-bilayer membrane, Chem. Lett. (2001) 556.
    • (2001) Chem. Lett. , pp. 556
    • Mizutani, F.1    Sawaguchi, T.2    Iijima, S.3
  • 4
    • 0035580978 scopus 로고    scopus 로고
    • Amperometric determination of acetic acid with a trienzyme/poly(dimethylsiloxane)-bilayer-based sensor
    • Mizutani F., Sawaguchi T., Sato Y., Yabuki S., Iijima S. Amperometric determination of acetic acid with a trienzyme/poly(dimethylsiloxane)-bilayer-based sensor. Anal. Chem. 73:2001;5738.
    • (2001) Anal. Chem. , vol.73 , pp. 5738
    • Mizutani, F.1    Sawaguchi, T.2    Sato, Y.3    Yabuki, S.4    Iijima, S.5
  • 5
    • 0001590748 scopus 로고    scopus 로고
    • Amperometric glucose sensor based on a polydimethyl siloxane/enzyme-bilayer membrane
    • Mizutani F., Sawaguchi T., Yabuki S., Iijima S. Amperometric glucose sensor based on a polydimethyl siloxane/enzyme-bilayer membrane. Electrochemistry. 67:1999;1138.
    • (1999) Electrochemistry , vol.67 , pp. 1138
    • Mizutani, F.1    Sawaguchi, T.2    Yabuki, S.3    Iijima, S.4
  • 6
    • 0034339594 scopus 로고    scopus 로고
    • Amperometric measurement of nitric oxide (NO) using an electrode coated with polydimethylsiloxane
    • F. Mizutani, Y. Hirata, S. Yabuki, S. Iijima, Amperometric measurement of nitric oxide (NO) using an electrode coated with polydimethylsiloxane, Chem. Lett. (2000) 802.
    • (2000) Chem. Lett. , pp. 802
    • Mizutani, F.1    Hirata, Y.2    Yabuki, S.3    Iijima, S.4
  • 7
    • 0035306413 scopus 로고    scopus 로고
    • Use of polydimethylsiloxane for constructing amperometric glucose-sensing enzyme electrode with low interference level
    • Mizutani F., Yabuki S., Iijima S. Use of polydimethylsiloxane for constructing amperometric glucose-sensing enzyme electrode with low interference level. Electroanalysis. 13:2001;370.
    • (2001) Electroanalysis , vol.13 , pp. 370
    • Mizutani, F.1    Yabuki, S.2    Iijima, S.3
  • 8
    • 0017889735 scopus 로고
    • Purification and properties of acetate kinase from Bacilius stearothermophilus
    • Nakajima H., Suzuki K., Imahori K. Purification and properties of acetate kinase from Bacilius stearothermophilus. J. Biochem. 84:1978;193.
    • (1978) J. Biochem. , vol.84 , pp. 193
    • Nakajima, H.1    Suzuki, K.2    Imahori, K.3
  • 9
    • 0000460846 scopus 로고
    • Equilibrium and kinetic studies of the pyruvic kinase reaction
    • McQuate J.T., Utter M.F. Equilibrium and kinetic studies of the pyruvic kinase reaction. J. Biol. Chem. 234:1959;2151.
    • (1959) J. Biol. Chem. , vol.234 , pp. 2151
    • McQuate, J.T.1    Utter, M.F.2
  • 11
    • 85004620468 scopus 로고
    • Determination of glutamate pyruvate transaminase and pyruvate with an amperometric pyruvate oxidase sensor
    • Mizutani F., Tsuda K., Karube I., Suzuki S., Matsumoto K. Determination of glutamate pyruvate transaminase and pyruvate with an amperometric pyruvate oxidase sensor. Anal. Chim. Acta. 118:1980;65.
    • (1980) Anal. Chim. Acta , vol.118 , pp. 65
    • Mizutani, F.1    Tsuda, K.2    Karube, I.3    Suzuki, S.4    Matsumoto, K.5
  • 12
    • 0001130885 scopus 로고
    • Determination of lactate dehydrogenase in serum using a pyruvate sensor
    • Minoura N., Yamada S., Karube I., Kubo I., Suzuki S. Determination of lactate dehydrogenase in serum using a pyruvate sensor. Anal. Chim. Acta. 135:1982;335.
    • (1982) Anal. Chim. Acta , vol.135 , pp. 335
    • Minoura, N.1    Yamada, S.2    Karube, I.3    Kubo, I.4    Suzuki, S.5
  • 13
    • 0002723070 scopus 로고
    • Determination of glutamate-pyruvate transaminase activity in blood serum with a pyruvate oxidase/poly(vinyl chloride) membrane sensor
    • Kihara K., Yasukawa E., Hayashi M., Hirose S. Determination of glutamate-pyruvate transaminase activity in blood serum with a pyruvate oxidase/poly(vinyl chloride) membrane sensor. Anal. Chim. Acta. 159:1984;81.
    • (1984) Anal. Chim. Acta , vol.159 , pp. 81
    • Kihara, K.1    Yasukawa, E.2    Hayashi, M.3    Hirose, S.4
  • 14
    • 0023236616 scopus 로고
    • Amperometric sensor for pyruvate with immobilized pyruvate oxidase
    • Mascini M., Mazzei F. Amperometric sensor for pyruvate with immobilized pyruvate oxidase. Anal. Chim. Acta. 192:1987;9.
    • (1987) Anal. Chim. Acta , vol.192 , pp. 9
    • Mascini, M.1    Mazzei, F.2
  • 15
    • 0025977574 scopus 로고
    • Oxidase peroxidase bilayer-modified electrodes as sensors for lactate, pyruvate, cholesterol and uric acid
    • Tatsuma T., Watanabe T. Oxidase peroxidase bilayer-modified electrodes as sensors for lactate, pyruvate, cholesterol and uric acid. Anal. Chim. Acta. 242:1991;85.
    • (1991) Anal. Chim. Acta , vol.242 , pp. 85
    • Tatsuma, T.1    Watanabe, T.2
  • 16
    • 12444284482 scopus 로고    scopus 로고
    • Simultaneous determination of acetic acid and glycerol in wines using amperometric trienzyme electrodes
    • Mizutani F., Yabuki S., Hirata Y., Iijima S. Simultaneous determination of acetic acid and glycerol in wines using amperometric trienzyme electrodes. Anal. Sci. 17(Suppl.):2001;301.
    • (2001) Anal. Sci. , vol.17 , Issue.SUPPL. , pp. 301
    • Mizutani, F.1    Yabuki, S.2    Hirata, Y.3    Iijima, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.