-
1
-
-
0003580722
-
-
Berlin, Germany: Springer-Verlag, May 15
-
D. Popovic and T. Sinkjaer, Control of the Movement for the Physically Disabled, 1st ed. Berlin, Germany: Springer-Verlag, May 15, 2000.
-
(2000)
Control of the Movement for the Physically Disabled, 1st Ed.
-
-
Popovic, D.1
Sinkjaer, T.2
-
2
-
-
27644591279
-
A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems
-
X. Navarro, T. B. Krueger, N. Lago, S. Micera, P. Dario, and T. Stieglitz, "A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems," J. Pher. Nerv. Syst., vol. 10, no. 3, pp. 229-258, 2005.
-
(2005)
J. Pher. Nerv. Syst.
, vol.10
, Issue.3
, pp. 229-258
-
-
Navarro, X.1
Krueger, T.B.2
Lago, N.3
Micera, S.4
Dario, P.5
Stieglitz, T.6
-
3
-
-
2942653497
-
Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode
-
Jun.
-
M. D. Tarler and J. T. Mortimer, "Selective and independent activation of four motor fascicles using a four contact nerve-cuff electrode," IEEE Trans. Neural Syst. Rehab. Eng., vol. 12, no. 2, pp. 251-257, Jun. 2004.
-
(2004)
IEEE Trans. Neural Syst. Rehab. Eng.
, vol.12
, Issue.2
, pp. 251-257
-
-
Tarler, M.D.1
Mortimer, J.T.2
-
4
-
-
9644252908
-
Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the peripheral nerve
-
N. Lago, D. Ceballos, F. Rodriguez, T. Stieglitz, and X. Navarro, "Long term assessment of axonal regeneration through polyimide regenerative electrodes to interface the peripheral nerve," Biomaterials, vol. 26, no. 14, pp. 2021-2031, 2005.
-
(2005)
Biomaterials
, vol.26
, Issue.14
, pp. 2021-2031
-
-
Lago, N.1
Ceballos, D.2
Rodriguez, F.3
Stieglitz, T.4
Navarro, X.5
-
5
-
-
4544278497
-
Acute peripheral nerve recording characteristics of polymer-based longitudinal intrafascicular electrodes
-
Sep.
-
S. M. Lawrence, G. S. Dhillon, W. Jensen, K. Yoshida, and K. W. Horch, "Acute peripheral nerve recording characteristics of polymer-based longitudinal intrafascicular electrodes," IEEE Trans. Neural Syst. Rehab. Eng., vol. 12, no. 3, pp. 345-348, Sep. 2004.
-
(2004)
IEEE Trans. Neural Syst. Rehab. Eng.
, vol.12
, Issue.3
, pp. 345-348
-
-
Lawrence, S.M.1
Dhillon, G.S.2
Jensen, W.3
Yoshida, K.4
Horch, K.W.5
-
6
-
-
33845589976
-
Characterization of tLIFE neural response for the control of a cybernetic hand
-
presented at the, Pisa, Italy
-
L. Citi, S. Micera, J. Carpaneto, K. Yoshida, K. P. Hoffmann, K. P. Koch, and P. Dario, "Characterization of tLIFE neural response for the control of a cybernetic hand," presented at the 1st IEEE RAS/EMBS Conf. Biorobotics and Biomechatronics (BioRob), Pisa, Italy, 2006.
-
(2006)
1st IEEE RAS/EMBS Conf. Biorobotics and Biomechatronics (BioRob)
-
-
Citi, L.1
Micera, S.2
Carpaneto, J.3
Yoshida, K.4
Hoffmann, K.P.5
Koch, K.P.6
Dario, P.7
-
7
-
-
2942677561
-
Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses
-
Jun.
-
D. McDonnall, G. A. Clark, and R. A. Normann, "Interleaved, multisite electrical stimulation of cat sciatic nerve produces fatigue-resistant, ripple-free motor responses," IEEE Trans Neural Syst. Rehab. Eng., vol. 12, no. 2, pp. 208-215, Jun. 2004.
-
(2004)
IEEE Trans. Neural Syst. Rehab. Eng.
, vol.12
, Issue.2
, pp. 208-215
-
-
McDonnall, D.1
Clark, G.A.2
Normann, R.A.3
-
8
-
-
0029879624
-
Biomechanical properties of peripheral nerves
-
R. Grewal, J. Xu, D. G. Soteranos, and S. L.-Y. Woo, "Biomechanical properties of peripheral nerves," Hand Clin., vol. 12, no. 2, pp. 195-204, 1996.
-
(1996)
Hand Clin.
, vol.12
, Issue.2
, pp. 195-204
-
-
Grewal, R.1
Xu, J.2
Soteranos, D.G.3
Woo, S.L.-Y.4
-
9
-
-
0141961579
-
Mechanical properties of acellular peripheral nerve
-
G. H. Borschel, K. F. Kia, W. M. Kuzon, Jr., and R. G. Dennis, "Mechanical properties of acellular peripheral nerve," J. Surgical Res., vol. 114, pp. 133-139, 2003.
-
(2003)
J. Surgical Res.
, vol.114
, pp. 133-139
-
-
Borschel, G.H.1
Kia, K.F.2
Kuzon Jr., W.M.3
Dennis, R.G.4
-
10
-
-
0025486307
-
An in vitro mechanical and histological study of acute stretching on rabbit tibial nerve
-
B. L. Rydevik, M. K. Kwan, R. R. Myers, R. A. Brown, K. J. Triggs, S. L. Woo, and S. R. Garfin, "An in vitro mechanical and histological study of acute stretching on rabbit tibial nerve," J. Orthop. Res., vol. 8, no. 5, pp. 694-701, 1990.
-
(1990)
J. Orthop. Res.
, vol.8
, Issue.5
, pp. 694-701
-
-
Rydevik, B.L.1
Kwan, M.K.2
Myers, R.R.3
Brown, R.A.4
Triggs, K.J.5
Woo, S.L.6
Garfin, S.R.7
-
11
-
-
2942716734
-
Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force
-
S. P. Davis, B. J. Landis, Z. H. Adams, G. M. Allen, and M. R. Prausnitz, "Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force," J. Biomech., vol. 37, pp. 1155-1163, 2004.
-
(2004)
J. Biomech.
, vol.37
, pp. 1155-1163
-
-
Davis, S.P.1
Landis, B.J.2
Adams, Z.H.3
Allen, G.M.4
Prausnitz, M.R.5
-
12
-
-
3042572777
-
Force modelling for needle insertion into soft tissue
-
Oct.
-
A. M. Okamura, C. Simone, and M. D. O'Leary, "Force modelling for needle insertion into soft tissue," IEEE Trans. Biomed. Eng., vol. 51, no. 10, pp. 1707-1716, Oct. 2004.
-
(2004)
IEEE Trans. Biomed. Eng.
, vol.51
, Issue.10
, pp. 1707-1716
-
-
Okamura, A.M.1
Simone, C.2
O'Leary, M.D.3
-
13
-
-
0344014251
-
Needle insertion and radioactive seed implantation in human tissues: Simulation and sensitivity analysis
-
R. Alterovitz, J. Pouliot, R. Taschereau, J. Hsu, and K. Goldberg, "Needle insertion and radioactive seed implantation in human tissues: simulation and sensitivity analysis," in Proc 2003 IEEE Int. Conf. Robotics and Automation (ICRA 2003), 2003, pp. 1793-1799.
-
(2003)
Proc. 2003 IEEE Int. Conf. Robotics and Automation (ICRA 2003)
, pp. 1793-1799
-
-
Alterovitz, R.1
Pouliot, J.2
Taschereau, R.3
Hsu, J.4
Goldberg, K.5
-
14
-
-
20444448852
-
Interactive simulation of needle insertion models
-
Jul.
-
S. P. DiMaio and S. E. Salcudean, "Interactive simulation of needle insertion models," IEEE Trans. Biomed. Eng., vol. 52, no. 7, pp. 1167-1179, Jul. 2005.
-
(2005)
IEEE Trans. Biomed. Eng.
, vol.52
, Issue.7
, pp. 1167-1179
-
-
DiMaio, S.P.1
Salcudean, S.E.2
-
15
-
-
20444437666
-
Needle steering and motion planning in soft tissues
-
Jun.
-
_, "Needle steering and motion planning in soft tissues," IEEE Trans. Biomed. Eng., vol. 52, no. 6, pp. 965-974, Jun. 2005.
-
(2005)
IEEE Trans. Biomed. Eng.
, vol.52
, Issue.6
, pp. 965-974
-
-
-
16
-
-
33846121622
-
Trajectory optimization for dynamic needle insertion
-
Barcelona, Spain
-
H. Heverly, P. Dupont, and J. Triedman, "Trajectory optimization for dynamic needle insertion," in Proc IEEE Int. Conf. Robotics and Automation, Barcelona, Spain, 2005, pp. 1658-1663.
-
(2005)
Proc. IEEE Int. Conf. Robotics and Automation
, pp. 1658-1663
-
-
Heverly, H.1
Dupont, P.2
Triedman, J.3
-
17
-
-
23644450228
-
Virtual remote center of motion control for needle placement robots
-
E. M. Boctor, R. J. Webster, III, H. Mathieu, A. M. Okamura, and G. Fichtinger, "Virtual remote center of motion control for needle placement robots," Comput. Aided. Surg., vol. 9, no. 5. pp. 175-183, 2004.
-
(2004)
Comput. Aided. Surg.
, vol.9
, Issue.5
, pp. 175-183
-
-
Boctor, E.M.1
Webster III, R.J.2
Mathieu, H.3
Okamura, A.M.4
Fichtinger, G.5
-
18
-
-
3042572777
-
Force modeling for needle insertion into soft tissue
-
Oct.
-
A. M. Okamura, C. Simone, and M. D. O'Leary, "Force modeling for needle insertion into soft tissue," IEEE Trans. Biomed. Eng., vol. 51, no. 10, pp. 1707-1716, Oct. 2004.
-
(2004)
IEEE Trans. Biomed. Eng.
, vol.51
, Issue.10
, pp. 1707-1716
-
-
Okamura, A.M.1
Simone, C.2
O'Leary, M.D.3
-
19
-
-
0018921334
-
The biomechanical responses to tension in a peripheral nerve
-
F. W. Bora, Jr., S. Richardson, and J. Black, "The biomechanical responses to tension in a peripheral nerve," J. Hand Surg., vol. 5, no. 1, pp. 21-25, 1980.
-
(1980)
J. Hand Surg.
, vol.5
, Issue.1
, pp. 21-25
-
-
Bora Jr., F.W.1
Richardson, S.2
Black, J.3
-
20
-
-
0029042746
-
Mechanical properties of peripheral nerves
-
H. Millesi, G. Zoch, and R. Reihsner, "Mechanical properties of peripheral nerves," Clin. Orthop. Related Res., vol. 314, pp. 76-83, 1995.
-
(1995)
Clin. Orthop. Related Res.
, vol.314
, pp. 76-83
-
-
Millesi, H.1
Zoch, G.2
Reihsner, R.3
-
21
-
-
0028917901
-
Effects of freeze/thaw conditioning on the tensile properties and failure mode of bone-muscle-bone units: A biomechanical and histological study in dogs
-
F. Gottsauner-Wolf, J. J. Grabowski, E. Y. S. Chao, and K. N. An, "Effects of freeze/thaw conditioning on the tensile properties and failure mode of bone-muscle-bone units: a biomechanical and histological study in dogs," J. Orthop. Res., vol. 13, no. 1, pp. 90-95, 2005.
-
(2005)
J. Orthop. Res.
, vol.13
, Issue.1
, pp. 90-95
-
-
Gottsauner-Wolf, F.1
Grabowski, J.J.2
Chao, E.Y.S.3
An, K.N.4
-
22
-
-
0030175411
-
Biomechanical and histological changes in the patellar tendon after in situ freezing
-
K. Ohno, Y. Yasuda, N. Yamamoto, K. Kaneda, and K. Hayashi, "Biomechanical and histological changes in the patellar tendon after in situ freezing," Clin. Biomech., vol. 11, no. 4, pp. 207-213, 1996.
-
(1996)
Clin. Biomech.
, vol.11
, Issue.4
, pp. 207-213
-
-
Ohno, K.1
Yasuda, Y.2
Yamamoto, N.3
Kaneda, K.4
Hayashi, K.5
-
24
-
-
0032943180
-
Mechanical properties of collagen fascicles from stress-shielded patellar tendons in the rabbit
-
E. Yamamoto, K. Hayashi, and N. Yamamoto, "Mechanical properties of collagen fascicles from stress-shielded patellar tendons in the rabbit," Clin. Biomech., vol. 14, no. 6, pp. 418-425, 1999.
-
(1999)
Clin. Biomech.
, vol.14
, Issue.6
, pp. 418-425
-
-
Yamamoto, E.1
Hayashi, K.2
Yamamoto, N.3
-
25
-
-
0032023387
-
Mechanical properties of biomedical titanium alloys
-
M. Niinomi, "Mechanical properties of biomedical titanium alloys," Mater. Sci. Eng., vol. A243, no. 1-2, pp. 231-236, 1998.
-
(1998)
Mater. Sci. Eng.
, vol.A243
, Issue.1-2
, pp. 231-236
-
-
Niinomi, M.1
-
26
-
-
0035095902
-
Flexible polyimide-based intracortical electrode arrays with bioactive capability
-
Mar.
-
P. J. Rousche, D. S. Pellinen, D. P. Pivin, J. C. Williams, R. J. Vetter, and D. R. Kipke, "Flexible polyimide-based intracortical electrode arrays with bioactive capability," IEEE Trans. Biomed. Eng., vol. 48, no. 3, pp. 361-371, Mar. 2001.
-
(2001)
IEEE Trans. Biomed. Eng.
, vol.48
, Issue.3
, pp. 361-371
-
-
Rousche, P.J.1
Pellinen, D.S.2
Pivin, D.P.3
Williams, J.C.4
Vetter, R.J.5
Kipke, D.R.6
-
28
-
-
0031123654
-
The influence of young's modulus on roundness in silicon sphere fabrication
-
Apr.
-
J. G. Collins, W. J. Giardini, A. J. Leistner, and M. J. Kenny, "The influence of young's modulus on roundness in silicon sphere fabrication," IEEE Trans. Instrum. Meas., vol. 46, no. 2, pp. 572-575, Apr. 1997.
-
(1997)
IEEE Trans. Instrum. Meas.
, vol.46
, Issue.2
, pp. 572-575
-
-
Collins, J.G.1
Giardini, W.J.2
Leistner, A.J.3
Kenny, M.J.4
-
29
-
-
0030869870
-
Micromechanical and tribological characterization of doped single-crystal silicon and polysilicon films for microelectromechanical system devices
-
B. Bhushan and X. Li, "Micromechanical and tribological characterization of doped single-crystal silicon and polysilicon films for microelectromechanical system devices," J. Mater. Res., vol. 12, no. 1, pp. 54-63, 1997.
-
(1997)
J. Mater. Res.
, vol.12
, Issue.1
, pp. 54-63
-
-
Bhushan, B.1
Li, X.2
-
31
-
-
0030213903
-
Effect of out-of-plane properties of a polyimide film on the stress fields in microelectronic structures
-
J. Dolbow and M. Gosz, "Effect of out-of-plane properties of a polyimide film on the stress fields in microelectronic structures," Mech. Mater., vol. 23, no. 4, pp. 311-321, 1996.
-
(1996)
Mech. Mater.
, vol.23
, Issue.4
, pp. 311-321
-
-
Dolbow, J.1
Gosz, M.2
-
33
-
-
0012692851
-
Modeling and finite element analysis of ultra-microhardness indentation of thin films
-
L. Gan, B. Ben-Nissan, and A. Ben-David, "Modeling and finite element analysis of ultra-microhardness indentation of thin films," Thin Solid Films, vol. 290-291, pp. 362-366, 1996.
-
(1996)
Thin Solid Films
, vol.290-291
, pp. 362-366
-
-
Gan, L.1
Ben-Nissan, B.2
Ben-David, A.3
-
34
-
-
0030064588
-
Application of finite elements to the stress analysis of articular cartilage
-
A. A. J. Goldsmith, A. Hayes, and S. E. Clift, "Application of finite elements to the stress analysis of articular cartilage," Med. Eng. Phys., vol. 18, no. 2, pp. 89-98, 1996.
-
(1996)
Med. Eng. Phys.
, vol.18
, Issue.2
, pp. 89-98
-
-
Goldsmith, A.A.J.1
Hayes, A.2
Clift, S.E.3
-
35
-
-
0038048151
-
A novel ultrasound indentation system for measuring biomechanical proprieties of in vivo soft tissue
-
L. Han, J. A. Noble, and M. Burcher, "A novel ultrasound indentation system for measuring biomechanical proprieties of in vivo soft tissue," Ultrasound Med. Biol., vol. 29, no. 6, pp. 813-823, 2003.
-
(2003)
Ultrasound Med. Biol.
, vol.29
, Issue.6
, pp. 813-823
-
-
Han, L.1
Noble, J.A.2
Burcher, M.3
-
36
-
-
0031238905
-
Estimating the effective Young's modulus of soft tissues from indentation tests- non linear finite elements analysis of effects of friction and large deformation
-
M. Zhang, Y. P. Zheng, and F. T. A. Mark, "Estimating the effective Young's modulus of soft tissues from indentation tests- non linear finite elements analysis of effects of friction and large deformation," Med. Eng. Phys., vol. 19, no. 6, pp. 512-517, 1997.
-
(1997)
Med. Eng. Phys.
, vol.19
, Issue.6
, pp. 512-517
-
-
Zhang, M.1
Zheng, Y.P.2
Mark, F.T.A.3
-
37
-
-
0033118271
-
Microscopic anatomy of the posterior intraosseus and median nerves at sites of potential entrapment in the forearm
-
S. Hill and S. Hall, "Microscopic anatomy of the posterior intraosseus and median nerves at sites of potential entrapment in the forearm," J. Hand Surg. (British and European Volume), vol. 24B, no. 2, pp. 170-176, 1999.
-
(1999)
J. Hand Surg. (British and European Volume)
, vol.24 B
, Issue.2
, pp. 170-176
-
-
Hill, S.1
Hall, S.2
-
38
-
-
0025435155
-
Strength characterization of silicon microprobes in neurophysiological tissues
-
May
-
K. Najafi and J. F. Hetke, "Strength characterization of silicon microprobes in neurophysiological tissues," IEEE Trans. Biomed. Eng., vol. 37, no. 5, pp. 474-481, May 1990.
-
(1990)
IEEE Trans. Biomed. Eng.
, vol.37
, Issue.5
, pp. 474-481
-
-
Najafi, K.1
Hetke, J.F.2
-
40
-
-
0026735250
-
A glass/silicon composite intracortical electrode array
-
E. J. Jones, P. K. Campbell, and R. A. Normann, "A glass/silicon composite intracortical electrode array," Ann. Biomed. Eng., vol. 20, no. 4, pp. 423-437, 1992.
-
(1992)
Ann. Biomed. Eng.
, vol.20
, Issue.4
, pp. 423-437
-
-
Jones, E.J.1
Campbell, P.K.2
Normann, R.A.3
-
41
-
-
0034001259
-
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
-
A. Branner and R. A. Normann, "A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats," Brain Res. Bull., vol. 51, no. 4, pp. 293-306, 2000.
-
(2000)
Brain Res. Bull.
, vol.51
, Issue.4
, pp. 293-306
-
-
Branner, A.1
Normann, R.A.2
-
42
-
-
0348147669
-
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
-
Jan.
-
A. Branner, R. B. Stein, E. Fernandez, Y. Aoyagi, and R. A. Normann, "Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve," IEEE Trans. Biomed. Eng., vol. 51, no. 1, pp. 146-157, Jan. 2004.
-
(2004)
IEEE Trans. Biomed. Eng.
, vol.51
, Issue.1
, pp. 146-157
-
-
Branner, A.1
Stein, R.B.2
Fernandez, E.3
Aoyagi, Y.4
Normann, R.A.5
-
43
-
-
0041387461
-
Capabilities of a penetrating microelectrode array for recording single units in dorsal root ganglia of the cat
-
Y. Aoyagi, R. B. Stein, A. Branner, K. G. Pearson, and R. A. Normann, "Capabilities of a penetrating microelectrode array for recording single units in dorsal root ganglia of the cat," J. Neurosci. Meth., vol. 128, no. 1-2, pp. 9-20, 2003.
-
(2003)
J. Neurosci. Meth.
, vol.128
, Issue.1-2
, pp. 9-20
-
-
Aoyagi, Y.1
Stein, R.B.2
Branner, A.3
Pearson, K.G.4
Normann, R.A.5
-
44
-
-
0032125652
-
Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex
-
P. J. Rousche and R. A. Normann, "Chronic recording capability of the Utah intracortical electrode array in cat sensory cortex," J. Neurosci. Meth., vol. 82, no. 1, pp. 1-15, 1998.
-
(1998)
J. Neurosci. Meth.
, vol.82
, Issue.1
, pp. 1-15
-
-
Rousche, P.J.1
Normann, R.A.2
|