Volumn 13, Issue 1, 1995, Pages 90-95
|
Effects of freeze/thaw conditioning on the tensile properties and failure mode of bone‐muscle‐bone units: A biomechanical and histological study in dogs
a a a a |
Author keywords
[No Author keywords available]
|
Indexed keywords
BIOMECHANICS;
FAILURE (MECHANICAL);
ORTHOPEDICS;
TENSILE PROPERTIES;
TENSILE TESTING;
FREEZE THAW CONDITIONING;
HISTOLOGY;
MUSCULOTENDINOUS JUNCTION;
POSTMORTEM AUTOLYSIS;
STIFFNESS;
ULTIMATE STRENGTH;
MUSCULOSKELETAL SYSTEM;
ANIMAL TISSUE;
ARTICLE;
BONE STRESS;
DOG;
FREEZING;
LOW TEMPERATURE;
NONHUMAN;
PRIORITY JOURNAL;
TENSILE STRENGTH;
THAWING;
|