메뉴 건너뛰기




Volumn 82, Issue 1, 1998, Pages 1-15

Chronic recording capability of the utah intracortical electrode array in cat sensory cortex

Author keywords

Chronic implant; Cortical histology; Multielectrode array; Neural recordings

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; CAT; CONTROLLED STUDY; ELECTROSTIMULATION; IMPEDANCE; IMPLANTATION; MACROGLIA; MICROELECTRODE; NONHUMAN; PRIORITY JOURNAL; RAT; SENSORY CORTEX;

EID: 0032125652     PISSN: 01650270     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0165-0270(98)00031-4     Document Type: Article
Times cited : (517)

References (30)
  • 2
    • 0014284770 scopus 로고
    • The sensations produced by electrical stimulation of the visual cortex
    • Brindley G.S., Lewin W.S. The sensations produced by electrical stimulation of the visual cortex. J Physiol. 196:1968;479-493.
    • (1968) J Physiol , vol.196 , pp. 479-493
    • Brindley, G.S.1    Lewin, W.S.2
  • 4
    • 0000688812 scopus 로고
    • Histopathological changes produced by implanted electrodes in cat brains. Comparison with histopatholgoical changes in human and experimental puncture wounds
    • Collias J.C., Manuelidis E.E. Histopathological changes produced by implanted electrodes in cat brains. Comparison with histopatholgoical changes in human and experimental puncture wounds. J Neurosurg. 14:1957;302-328.
    • (1957) J Neurosurg , vol.14 , pp. 302-328
    • Collias, J.C.1    Manuelidis, E.E.2
  • 6
    • 0016222161 scopus 로고
    • Phosphenes produced by electrical stimulation of human occipital cortex, and their application to the development of a prosthesis for the blind
    • Dobelle W.H., Mladejovsky M.G. Phosphenes produced by electrical stimulation of human occipital cortex, and their application to the development of a prosthesis for the blind. J Physiol. 243:1974;553-576.
    • (1974) J Physiol , vol.243 , pp. 553-576
    • Dobelle, W.H.1    Mladejovsky, M.G.2
  • 7
    • 0026882265 scopus 로고
    • Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
    • Edell D.J., Toi V.V., McNeil V.M., Clark L.D. Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex. IEEE Trans Biomed Eng. 39(6):1992;635-643.
    • (1992) IEEE Trans Biomed Eng , vol.39 , Issue.6 , pp. 635-643
    • Edell, D.J.1    Toi, V.V.2    McNeil, V.M.3    Clark, L.D.4
  • 8
    • 0022448771 scopus 로고
    • Extracellular neural recording with multichannel microelectrodes
    • Eichenbaum H., Kuperstein M. Extracellular neural recording with multichannel microelectrodes. J Electrophysiol Tech. 13:1986;189-209.
    • (1986) J Electrophysiol Tech , vol.13 , pp. 189-209
    • Eichenbaum, H.1    Kuperstein, M.2
  • 9
    • 0002882779 scopus 로고
    • Single unit activity in the auditory cortex of the cat
    • Erulkar S.D., Rose J.E. Single unit activity in the auditory cortex of the cat. Bull Johns Hopkins Hosp. 99:1956;55-86.
    • (1956) Bull Johns Hopkins Hosp , vol.99 , pp. 55-86
    • Erulkar, S.D.1    Rose, J.E.2
  • 10
    • 0028662508 scopus 로고
    • A three dimensional microelectrode array for chronic neural recording
    • Hoogerwerf A.C., Wise K.D. A three dimensional microelectrode array for chronic neural recording. IEEE Trans Biomed Eng. 41(12):1994;1136-1146.
    • (1994) IEEE Trans Biomed Eng , vol.41 , Issue.12 , pp. 1136-1146
    • Hoogerwerf, A.C.1    Wise, K.D.2
  • 11
    • 0025363295 scopus 로고
    • A multi-wire microelectrode for single unit recording in deep brain structures
    • Jaeger D., Gilman S., Aldridge J.W. A multi-wire microelectrode for single unit recording in deep brain structures. J Neurosci Methods. 32:1990;143-148.
    • (1990) J Neurosci Methods , vol.32 , pp. 143-148
    • Jaeger, D.1    Gilman, S.2    Aldridge, J.W.3
  • 12
    • 0026323286 scopus 로고
    • A slim needle shaped multi-wire microelectrode for intracerebral recording
    • Jellema T., Weijnen J.A. A slim needle shaped multi-wire microelectrode for intracerebral recording. J Neurosci Methods. 40(2-3):1991;203-209.
    • (1991) J Neurosci Methods , vol.40 , Issue.2-3 , pp. 203-209
    • Jellema, T.1    Weijnen, J.A.2
  • 14
    • 0019505585 scopus 로고
    • Simultaneous recording with 30 microelectrodes in monkey visual cortex
    • Kruger J., Bach M. Simultaneous recording with 30 microelectrodes in monkey visual cortex. Exp Brain Res. 41:1981;191-194.
    • (1981) Exp Brain Res , vol.41 , pp. 191-194
    • Kruger, J.1    Bach, M.2
  • 15
    • 0021325674 scopus 로고
    • A drivable bundle of microwires for collecting single-unit data from freely moving rats
    • Kubie J.L. A drivable bundle of microwires for collecting single-unit data from freely moving rats. Physiol Behav. 32:1984;115-118.
    • (1984) Physiol Behav , vol.32 , pp. 115-118
    • Kubie, J.L.1
  • 16
    • 0017462442 scopus 로고
    • Histological reaction to various conductive and dielectric films chronically implanted in the subdural space
    • Loeb G.E. Histological reaction to various conductive and dielectric films chronically implanted in the subdural space. J Biomed Mat Res. 11:1977;195-210.
    • (1977) J Biomed Mat Res , vol.11 , pp. 195-210
    • Loeb, G.E.1
  • 17
    • 0031106324 scopus 로고    scopus 로고
    • The Utah intracortical electrode array: A recording structure for potential brain-computer interfaces
    • Maynard EM, Nordhausen CT, Normann RA. The Utah intracortical electrode array: a recording structure for potential brain-computer interfaces. Electroenceph Clin Neurophysiol 1997;102(3):228-39.
    • (1997) Electroenceph Clin Neurophysiol , vol.102 , Issue.3 , pp. 228-239
    • Maynard, E.M.1    Nordhausen, C.T.2    Normann, R.A.3
  • 18
    • 0016703883 scopus 로고
    • Representation of the cochlea within the primary auditory cortex of the cat
    • Merzenich M.M., Knight P.L., Roth G.L. Representation of the cochlea within the primary auditory cortex of the cat. J Neurophysiol. 38:1975;231-249.
    • (1975) J Neurophysiol , vol.38 , pp. 231-249
    • Merzenich, M.M.1    Knight, P.L.2    Roth, G.L.3
  • 19
    • 0028144251 scopus 로고
    • Optimizing recording capabilities of the Utah Intracortical Electrode Array
    • Nordhausen C.T., Rousche P.J., Normann R.A. Optimizing recording capabilities of the Utah Intracortical Electrode Array. Brain Res. 637:1994;27-36.
    • (1994) Brain Res , vol.637 , pp. 27-36
    • Nordhausen, C.T.1    Rousche, P.J.2    Normann, R.A.3
  • 21
    • 0026547554 scopus 로고
    • Prediction of the side of hand movements from single-trial multi-channel EEG data using neural networks
    • Pfurtscheller G., Flotzinger D., Mohl W., Peltoranta M. Prediction of the side of hand movements from single-trial multi-channel EEG data using neural networks. Electroenceph Clin Neurophysiol. 82:1992;313-315.
    • (1992) Electroenceph Clin Neurophysiol , vol.82 , pp. 313-315
    • Pfurtscheller, G.1    Flotzinger, D.2    Mohl, W.3    Peltoranta, M.4
  • 22
    • 0022559398 scopus 로고
    • Thin-film multiple electrode probes: Possibilities and limitations
    • Prohaska O.J., Olcaytug F., Pfunder P., Dragaun H. Thin-film multiple electrode probes: possibilities and limitations. IEEE Trans Biomed Eng. 33(2):1986;223-229.
    • (1986) IEEE Trans Biomed Eng , vol.33 , Issue.2 , pp. 223-229
    • Prohaska, O.J.1    Olcaytug, F.2    Pfunder, P.3    Dragaun, H.4
  • 23
    • 0026637518 scopus 로고
    • A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
    • Rousche P.J., Normann R.A. A method for pneumatically inserting an array of penetrating electrodes into cortical tissue. Ann Biomed Eng. 20(4):1992;413-422.
    • (1992) Ann Biomed Eng , vol.20 , Issue.4 , pp. 413-422
    • Rousche, P.J.1    Normann, R.A.2
  • 24
    • 0015640136 scopus 로고
    • Design, fabrication, and in-vivo behavior of chronic recording intracortical microelectrodes
    • Salcman M., Bak M.J. Design, fabrication, and in-vivo behavior of chronic recording intracortical microelectrodes. IEEE Trans Biomed Eng. 20(4):1973;253-260.
    • (1973) IEEE Trans Biomed Eng , vol.20 , Issue.4 , pp. 253-260
    • Salcman, M.1    Bak, M.J.2
  • 25
    • 0027069396 scopus 로고
    • Macrophage response to microtextured silicone
    • Schimdt J.A., von Recum A.F. Macrophage response to microtextured silicone. Biomaterials. 13(15):1992;1059-1069.
    • (1992) Biomaterials , vol.13 , Issue.15 , pp. 1059-1069
    • Schimdt, J.A.1    Von Recum, A.F.2
  • 26
    • 0029964253 scopus 로고    scopus 로고
    • Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex
    • Schmidt E.M., Bak M.J., Hambrecht F.T., Kafta C.V., O'Rourke D.K., Vallabhanath P. Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex. Brain. 119:1996;407-422.
    • (1996) Brain , vol.119 , pp. 407-422
    • Schmidt, E.M.1    Bak, M.J.2    Hambrecht, F.T.3    Kafta, C.V.4    O'Rourke, D.K.5    Vallabhanath, P.6
  • 27
    • 0017178865 scopus 로고
    • Long-term chronic recording from cortical neurons
    • Schmidt E.M., Bak M.J. Long-term chronic recording from cortical neurons. Exp Neurol. 52:1976;496-506.
    • (1976) Exp Neurol , vol.52 , pp. 496-506
    • Schmidt, E.M.1    Bak, M.J.2
  • 28
    • 0018163887 scopus 로고
    • Histopathological evaluation of materials implanted in the cerebral cortex
    • Stensaas S.S., Stensaas L.J. Histopathological evaluation of materials implanted in the cerebral cortex. Acta Neuropathol (Berl). 41(2):1978;145-155.
    • (1978) Acta Neuropathol (Berl) , vol.41 , Issue.2 , pp. 145-155
    • Stensaas, S.S.1    Stensaas, L.J.2
  • 29
    • 0018359539 scopus 로고
    • Spike separation in multi-unit records: A multivariate analysis of spike descriptive parameters
    • Vibert J.F., Costa J. Spike separation in multi-unit records: a multivariate analysis of spike descriptive parameters. Electroenceph Clin Neurophysiol. 47(2):1979;172-182.
    • (1979) Electroenceph Clin Neurophysiol , vol.47 , Issue.2 , pp. 172-182
    • Vibert, J.F.1    Costa, J.2
  • 30
    • 0016499925 scopus 로고
    • A low-capacitance multielectrode probe for use in extracellular neurophysiology
    • Wise K.D., Angell J.B. A low-capacitance multielectrode probe for use in extracellular neurophysiology. IEEE Trans Biomed Eng. 22(3):1975;212-219.
    • (1975) IEEE Trans Biomed Eng , vol.22 , Issue.3 , pp. 212-219
    • Wise, K.D.1    Angell, J.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.