-
2
-
-
0021804032
-
Acute and chronic implantation of coiled wire intraneural electrodes during cyclical electrical stimulation
-
Bowman B.R., Erickson R.C. Acute and chronic implantation of coiled wire intraneural electrodes during cyclical electrical stimulation. Ann. Biomed. Eng. 13:1985;75-93.
-
(1985)
Ann. Biomed. Eng.
, vol.13
, pp. 75-93
-
-
Bowman, B.R.1
Erickson, R.C.2
-
3
-
-
0342657470
-
A 20 channel peripheral nerve interface: Recording and stimulation in mammalian sciatic nerve
-
Branner A., Kolb H., Normann R.A. A 20 channel peripheral nerve interface Recording and stimulation in mammalian sciatic nerve . Soc. Neurosci. Abstr. 22:1996;668.
-
(1996)
Soc. Neurosci. Abstr.
, vol.22
, pp. 668
-
-
Branner, A.1
Kolb, H.2
Normann, R.A.3
-
4
-
-
0031239099
-
Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs
-
Cameron T., Loeb G.E., Peck R.A., Schulman J.H., Strojnik P., Troyk P.R. Micromodular implants to provide electrical stimulation of paralyzed muscles and limbs. IEEE Trans. Biomed. Eng. 44:1997;781-790.
-
(1997)
IEEE Trans. Biomed. Eng.
, vol.44
, pp. 781-790
-
-
Cameron, T.1
Loeb, G.E.2
Peck, R.A.3
Schulman, J.H.4
Strojnik, P.5
Troyk, P.R.6
-
5
-
-
0026205082
-
A silicon-based, three-dimensional neural interface: Manufacturing processes for an intracortical electrode array
-
Campbell P.K., Jones K.E., Huber R.J., Horch K.W., Normann R.A. A silicon-based, three-dimensional neural interface Manufacturing processes for an intracortical electrode array . IEEE Trans. Biomed. Eng. 38:1991;758-768.
-
(1991)
IEEE Trans. Biomed. Eng.
, vol.38
, pp. 758-768
-
-
Campbell, P.K.1
Jones, K.E.2
Huber, R.J.3
Horch, K.W.4
Normann, R.A.5
-
6
-
-
0018196363
-
Compound action potentials recorded from mammalian peripheral nerves following ligation or resuturing
-
Davis L.A., Gordon T., Hoffer J.A., Jhamandas J., Stein R.B. Compound action potentials recorded from mammalian peripheral nerves following ligation or resuturing. J. Physiol. 285:1978;543-559.
-
(1978)
J. Physiol.
, vol.285
, pp. 543-559
-
-
Davis, L.A.1
Gordon, T.2
Hoffer, J.A.3
Jhamandas, J.4
Stein, R.B.5
-
7
-
-
0001440005
-
The recording of nerve action potentials through skin in man
-
Dawson G.D., Scott J.W. The recording of nerve action potentials through skin in man. J. Neurol. Neurosurg. Psychiat. 12:1949;259-267.
-
(1949)
J. Neurol. Neurosurg. Psychiat.
, vol.12
, pp. 259-267
-
-
Dawson, G.D.1
Scott, J.W.2
-
8
-
-
0024528092
-
De- And regeneration of axons after minor lesions in the rat sciatic nerve. Effects of microneurography electrode penetrations
-
Fried K., Frisen J., Mozart M. De- and regeneration of axons after minor lesions in the rat sciatic nerve. Effects of microneurography electrode penetrations. Pain. 36:1989;93-102.
-
(1989)
Pain
, vol.36
, pp. 93-102
-
-
Fried, K.1
Frisen, J.2
Mozart, M.3
-
9
-
-
0025948750
-
Axotomy-induced changes in rabbit hindlimb nerves and the effects of chronic electrical stimulation
-
Gordon T., Gillespie J., Orozco R., Davis L. Axotomy-induced changes in rabbit hindlimb nerves and the effects of chronic electrical stimulation. J. Neurosci. 11:1991;2157-2169.
-
(1991)
J. Neurosci.
, vol.11
, pp. 2157-2169
-
-
Gordon, T.1
Gillespie, J.2
Orozco, R.3
Davis, L.4
-
10
-
-
0030008272
-
Non-invasive measurement of the input-output properties of peripheral nerve stimulating electrodes
-
Grill W.M., Mortimer J.T. Non-invasive measurement of the input-output properties of peripheral nerve stimulating electrodes. J. Neurosci. Methods. 65:1996;43-50.
-
(1996)
J. Neurosci. Methods
, vol.65
, pp. 43-50
-
-
Grill, W.M.1
Mortimer, J.T.2
-
11
-
-
0014042268
-
Mechanoreceptor activity recorded percutaneously with semi-microelectrodes in human peripheral nerves
-
Hagbarth K.E., Vallbo A.B. Mechanoreceptor activity recorded percutaneously with semi-microelectrodes in human peripheral nerves. Acta. Physiol. Scand. 69:1967;121-122.
-
(1967)
Acta. Physiol. Scand.
, vol.69
, pp. 121-122
-
-
Hagbarth, K.E.1
Vallbo, A.B.2
-
12
-
-
0022468385
-
Percutaneous microneurography in man does not cause pressure block of almost all axons in the impaled nerve fascicle
-
Hallin R.G., Wiesenfeld-Hallin Z., Duranti R. Percutaneous microneurography in man does not cause pressure block of almost all axons in the impaled nerve fascicle. Neurosc. Lett. 68:1986;356-361.
-
(1986)
Neurosc. Lett.
, vol.68
, pp. 356-361
-
-
Hallin, R.G.1
Wiesenfeld-Hallin, Z.2
Duranti, R.3
-
13
-
-
0031868320
-
Protocol for microneurography with concentric needle electrodes
-
Hallin R.G., Wu G. Protocol for microneurography with concentric needle electrodes. Brain Res. Brain Res. Protoc. 2:1998;120-132.
-
(1998)
Brain Res. Brain Res. Protoc.
, vol.2
, pp. 120-132
-
-
Hallin, R.G.1
Wu, G.2
-
14
-
-
0001586581
-
Afferent impulses in cutaneous sensory nerves in human subjects
-
Hensel H., Boman K.K.A. Afferent impulses in cutaneous sensory nerves in human subjects. J. Neurophysiol. 23:1960;564-578.
-
(1960)
J. Neurophysiol.
, vol.23
, pp. 564-578
-
-
Hensel, H.1
Boman, K.K.A.2
-
15
-
-
0002797562
-
Techniques to study spinal-cord, peripheral nerve, and muscle activity in freely moving animals
-
A.A. Boulton, G.B. Baker, Vanderwolf C.H. Clifton, NJ: Humana Press
-
Hoffer J.A. Techniques to study spinal-cord, peripheral nerve, and muscle activity in freely moving animals. Boulton A.A., Baker G.B., Vanderwolf C.H. Neurophysiological techniques Applications to neural systems . vol. 15:1990;65-145 Humana Press, Clifton, NJ.
-
(1990)
Neurophysiological Techniques: Applications to Neural Systems
, vol.15
, pp. 65-145
-
-
Hoffer, J.A.1
-
16
-
-
0001996384
-
Signals from tactile sensors in glabrous skin suitable for restoring motor function in paralyzed humans
-
R.B. Stein, P.H. Peckham, & D.B. Popovic. New York: Oxford University Press
-
Hoffer J.A., Haugland M.K. Signals from tactile sensors in glabrous skin suitable for restoring motor function in paralyzed humans. Stein R.B., Peckham P.H., Popovic D.B. Neural prosthesis Replacing motor function after disease or disability . 1992;99-125 Oxford University Press, New York.
-
(1992)
Neural Prosthesis: Replacing Motor Function after Disease or Disability
, pp. 99-125
-
-
Hoffer, J.A.1
Haugland, M.K.2
-
17
-
-
0030130946
-
Neural signals for command control and feedback in functional neuromuscular stimulation: A review
-
Hoffer J.A., Stein R.B., Haugland M.K., Sinkjaer T., Durfee W.K., Schwartz A.B., Loeb G.E., Kantor C. Neural signals for command control and feedback in functional neuromuscular stimulation A review . J. Rehabil. Res. Dev. 33:1996;145-157.
-
(1996)
J. Rehabil. Res. Dev.
, vol.33
, pp. 145-157
-
-
Hoffer, J.A.1
Stein, R.B.2
Haugland, M.K.3
Sinkjaer, T.4
Durfee, W.K.5
Schwartz, A.B.6
Loeb, G.E.7
Kantor, C.8
-
18
-
-
0026735250
-
A glass/silicon composite intracortical electrode array
-
Jones K.E., Campbell P.K., Normann R.A. A glass/silicon composite intracortical electrode array. Ann. Biomed. Eng. 20:1992;423-437.
-
(1992)
Ann. Biomed. Eng.
, vol.20
, pp. 423-437
-
-
Jones, K.E.1
Campbell, P.K.2
Normann, R.A.3
-
19
-
-
0026512434
-
Long-term results of nervous tissue alterations caused by epineurial electrode application: An experimental study in rat sciatic nerve
-
Koller R., Girsch W., Liegl C., Gruber H., Holle J., Losert U., Mayr W., Thoma H. Long-term results of nervous tissue alterations caused by epineurial electrode application An experimental study in rat sciatic nerve . Pacing Clin. Electrophysiol. 15:1992;108-115.
-
(1992)
Pacing Clin. Electrophysiol.
, vol.15
, pp. 108-115
-
-
Koller, R.1
Girsch, W.2
Liegl, C.3
Gruber, H.4
Holle, J.5
Losert, U.6
Mayr, W.7
Thoma, H.8
-
20
-
-
0028450429
-
Silicon-substrate microelectrode arrays for parallel recording of neural activity in peripheral and cranial nerves
-
Kovacs G.T., Storment C.W., Halks Miller M., Belczynski C.R. Jr, Della Santina C.C., Lewis E.R., Maluf N.I. Silicon-substrate microelectrode arrays for parallel recording of neural activity in peripheral and cranial nerves. IEEE Trans. Biomed. Eng. 41:1994;567-577.
-
(1994)
IEEE Trans. Biomed. Eng.
, vol.41
, pp. 567-577
-
-
Kovacs, G.T.1
Storment, C.W.2
Halks Miller, M.3
Belczynski C.R., Jr.4
Della Santina, C.C.5
Lewis, E.R.6
Maluf, N.I.7
-
21
-
-
0025818911
-
Chronically implanted intrafascicular recording electrodes
-
Lefurge T., Goodall E., Horch K.W., Stensaas L., Schoenberg A.A. Chronically implanted intrafascicular recording electrodes. Ann. Biomed. Eng. 19:1991;197-207.
-
(1991)
Ann. Biomed. Eng.
, vol.19
, pp. 197-207
-
-
Lefurge, T.1
Goodall, E.2
Horch, K.W.3
Stensaas, L.4
Schoenberg, A.A.5
-
22
-
-
0026153728
-
A method for evaluating the selectivity of electrodes implanted for nerve simulation
-
Liang D.H., Kovacs G.T., Storment C.W., White R.L. A method for evaluating the selectivity of electrodes implanted for nerve simulation. IEEE Trans. Biomed. Eng. 38:1991;443-449.
-
(1991)
IEEE Trans. Biomed. Eng.
, vol.38
, pp. 443-449
-
-
Liang, D.H.1
Kovacs, G.T.2
Storment, C.W.3
White, R.L.4
-
23
-
-
0030066135
-
Cuff electrodes for chronic stimulation and recording of peripheral nerve activity
-
Loeb G.E., Peck R.A. Cuff electrodes for chronic stimulation and recording of peripheral nerve activity. J. Neurosci. Methods. 64:1996;95-103.
-
(1996)
J. Neurosci. Methods
, vol.64
, pp. 95-103
-
-
Loeb, G.E.1
Peck, R.A.2
-
24
-
-
0031106324
-
The Utah Intracortical Electrode Array: A recording structure for potential brain-computer interfaces
-
Maynard E.M., Nordhausen C.T., Normann R.A. The Utah Intracortical Electrode Array A recording structure for potential brain-computer interfaces . Electroencephalogr. Clin. Neurophysiol. 102:1997;228-239.
-
(1997)
Electroencephalogr. Clin. Neurophysiol.
, vol.102
, pp. 228-239
-
-
Maynard, E.M.1
Nordhausen, C.T.2
Normann, R.A.3
-
25
-
-
0024637198
-
Recruitment data for nerve cuff electrodes: Implications for design of implantable stimulators
-
McNeal D.R., Baker L.L., Symons J.T. Recruitment data for nerve cuff electrodes Implications for design of implantable stimulators . IEEE Trans. Biomed. Eng. 36:1989;301-308.
-
(1989)
IEEE Trans. Biomed. Eng.
, vol.36
, pp. 301-308
-
-
McNeal, D.R.1
Baker, L.L.2
Symons, J.T.3
-
26
-
-
0022061146
-
Selective activation of muscles using peripheral nerve electrodes
-
McNeal D.R., Bowman B.R. Selective activation of muscles using peripheral nerve electrodes. Med. Biolog. Eng. Comput. 23:1985;249-253.
-
(1985)
Med. Biolog. Eng. Comput.
, vol.23
, pp. 249-253
-
-
McNeal, D.R.1
Bowman, B.R.2
-
27
-
-
0029294490
-
Force recruitment during electrical nerve stimulation with multipolar intrafascicular electrodes
-
Meier J.H., Rutten W.L., Boom H.B. Force recruitment during electrical nerve stimulation with multipolar intrafascicular electrodes. Med. Biol. Eng. Comput. 33:1995;409-417.
-
(1995)
Med. Biol. Eng. Comput.
, vol.33
, pp. 409-417
-
-
Meier, J.H.1
Rutten, W.L.2
Boom, H.B.3
-
28
-
-
0026206943
-
Muscle recruitment with intrafascicular electrodes
-
Nannini N., Horch K.W. Muscle recruitment with intrafascicular electrodes. IEEE Trans. Biomed. Eng. 38:1991;769-776.
-
(1991)
IEEE Trans. Biomed. Eng.
, vol.38
, pp. 769-776
-
-
Nannini, N.1
Horch, K.W.2
-
29
-
-
0030575296
-
Single unit recording capabilities of a 100 microelectrode array
-
Nordhausen C.T., Maynard E.M., Normann R.A. Single unit recording capabilities of a 100 microelectrode array. Brain Res. 726:1996;129-140.
-
(1996)
Brain Res.
, vol.726
, pp. 129-140
-
-
Nordhausen, C.T.1
Maynard, E.M.2
Normann, R.A.3
-
30
-
-
0020536928
-
Physiological characterization of motor unit properties in intact cats
-
O'Donovan M., Hoffer J.A., Loeb G.E. Physiological characterization of motor unit properties in intact cats. J. Neurosci. Methods. 7:1983;137-149.
-
(1983)
J. Neurosci. Methods
, vol.7
, pp. 137-149
-
-
O'Donovan, M.1
Hoffer, J.A.2
Loeb, G.E.3
-
31
-
-
0028598274
-
The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man
-
Rice A.S.C., Andreev N.Y., McMahon S.B. The consequences of microneurography electrode-induced injury of peripheral nerves observed in the rat and man. Pain. 59:1994;385-393.
-
(1994)
Pain
, vol.59
, pp. 385-393
-
-
Rice, A.S.C.1
Andreev, N.Y.2
McMahon, S.B.3
-
32
-
-
0026480968
-
Peripheral nerve injury caused by injection needles used in regional anesthesia: Influence of bevel configuration, studied in a rat model
-
Rice A.S.C., McMahon S.B. Peripheral nerve injury caused by injection needles used in regional anesthesia Influence of bevel configuration, studied in a rat model . Br. J. Anaesth. 69:1992;433-438.
-
(1992)
Br. J. Anaesth.
, vol.69
, pp. 433-438
-
-
Rice, A.S.C.1
McMahon, S.B.2
-
33
-
-
0027787432
-
The electrophysiological consequences of electrode impalement of peripheral nerves in the rat
-
Rice A.S.C., McMahon S.B., Wall P.D. The electrophysiological consequences of electrode impalement of peripheral nerves in the rat. Brain Res. 631:1993;221-226.
-
(1993)
Brain Res.
, vol.631
, pp. 221-226
-
-
Rice, A.S.C.1
McMahon, S.B.2
Wall, P.D.3
-
34
-
-
0031018908
-
Urinary bladder control by electrical stimulation: Review of electrical stimulation techniques in spinal cord injury
-
Rijkhoff N.J.M., Wijkstra H., van Kerrebroeck P.E.V., Debruyne F.M.J. Urinary bladder control by electrical stimulation Review of electrical stimulation techniques in spinal cord injury . Neurourol. Urodyn. 16:1997;39-53.
-
(1997)
Neurourol. Urodyn.
, vol.16
, pp. 39-53
-
-
Rijkhoff, N.J.M.1
Wijkstra, H.2
Van Kerrebroeck, P.E.V.3
Debruyne, F.M.J.4
-
35
-
-
0026637518
-
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
-
Rousche P.J., Normann R.A. A method for pneumatically inserting an array of penetrating electrodes into cortical tissue. Ann. Biomed. Eng. 20:1992;413-422.
-
(1992)
Ann. Biomed. Eng.
, vol.20
, pp. 413-422
-
-
Rousche, P.J.1
Normann, R.A.2
-
36
-
-
0028392638
-
Implantable stimulator for selective stimulation of the common peroneal nerve: A preliminary report
-
Rozman J., Acimovic Janezic R., Tekavcic I., Kljajic M., Trlep M. Implantable stimulator for selective stimulation of the common peroneal nerve A preliminary report . J. Med. Eng. Technol. 18:1994;47-53.
-
(1994)
J. Med. Eng. Technol.
, vol.18
, pp. 47-53
-
-
Rozman, J.1
Acimovic Janezic, R.2
Tekavcic, I.3
Kljajic, M.4
Trlep, M.5
-
37
-
-
0027510672
-
Multielectrode spiral cuff for ordered and reversed activation of nerve fibres
-
Rozman J., Sovinec B., Trlep M., Zorko B. Multielectrode spiral cuff for ordered and reversed activation of nerve fibres. J. Biomed. Eng. 15:1993;113-120.
-
(1993)
J. Biomed. Eng.
, vol.15
, pp. 113-120
-
-
Rozman, J.1
Sovinec, B.2
Trlep, M.3
Zorko, B.4
-
38
-
-
0026253721
-
Selectivity of intraneural prosthetic interfaces for muscular control
-
Rutten W.L., Meier J.H. Selectivity of intraneural prosthetic interfaces for muscular control. Med. Biol. Eng. Comput. 29:1991;Ns3-Ns7.
-
(1991)
Med. Biol. Eng. Comput.
, vol.29
-
-
Rutten, W.L.1
Meier, J.H.2
-
39
-
-
0026106143
-
Sensitivity and selectivity of intraneural stimulation using a silicon electrode array
-
Rutten W.L., van Wier H.J., Put J.H. Sensitivity and selectivity of intraneural stimulation using a silicon electrode array. IEEE Trans. Biomed. Eng. 38:1991;192-198.
-
(1991)
IEEE Trans. Biomed. Eng.
, vol.38
, pp. 192-198
-
-
Rutten, W.L.1
Van Wier, H.J.2
Put, J.H.3
-
40
-
-
0027703631
-
Biocompatibility of silicon based electrode arrays implanted in feline cortical tissue
-
Schmidt S., Horch K.W., Normann R.A. Biocompatibility of silicon based electrode arrays implanted in feline cortical tissue. J. Biomed. Mat. Res. 27:1993;1393-1399.
-
(1993)
J. Biomed. Mat. Res.
, vol.27
, pp. 1393-1399
-
-
Schmidt, S.1
Horch, K.W.2
Normann, R.A.3
-
41
-
-
0030897606
-
Effect of long-term implanted nerve cuff electrodes on the electrophysiological properties of human sensory nerves
-
Slot P.J., Selmar P., Rasmussen A., Sinkjaer T. Effect of long-term implanted nerve cuff electrodes on the electrophysiological properties of human sensory nerves. Artif. Organs. 21:1997;207-209.
-
(1997)
Artif. Organs
, vol.21
, pp. 207-209
-
-
Slot, P.J.1
Selmar, P.2
Rasmussen, A.3
Sinkjaer, T.4
-
42
-
-
0029294523
-
Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays
-
Sweeney J.D., Crawford N.R., Brandon T.A. Neuromuscular stimulation selectivity of multiple-contact nerve cuff electrode arrays. Med. Biol. Eng. Comput. 33:1995;418-425.
-
(1995)
Med. Biol. Eng. Comput.
, vol.33
, pp. 418-425
-
-
Sweeney, J.D.1
Crawford, N.R.2
Brandon, T.A.3
-
43
-
-
0026666252
-
Clinical experience with a helical bipolar stimulating lead
-
Tarver W.B., George R.E., Maschino S.E., Holder L.K., Wernicke J.F. Clinical experience with a helical bipolar stimulating lead. Pacing Clin. Electrophysiol. 15:1992;1545-1556.
-
(1992)
Pacing Clin. Electrophysiol.
, vol.15
, pp. 1545-1556
-
-
Tarver, W.B.1
George, R.E.2
Maschino, S.E.3
Holder, L.K.4
Wernicke, J.F.5
-
44
-
-
0027454683
-
The vitality of the sciatic nerve of the frog and rat in a chamber which allows maintained in vitro recording of the compound nerve action potentials
-
[letter]
-
Theophilidis G., Pavlidou P. The vitality of the sciatic nerve of the frog and rat in a chamber which allows maintained in vitro recording of the compound nerve action potentials. Muscle Nerve. 16:1993;113-114. [letter].
-
(1993)
Muscle Nerve
, vol.16
, pp. 113-114
-
-
Theophilidis, G.1
Pavlidou, P.2
-
45
-
-
0026883619
-
Closed-loop class E transcutaneous power and data link for microimplants
-
Troyk P.R., Schwan M.A. Closed-loop class E transcutaneous power and data link for microimplants. IEEE Trans. Biomed. Eng. 39:1992;589-599.
-
(1992)
IEEE Trans. Biomed. Eng.
, vol.39
, pp. 589-599
-
-
Troyk, P.R.1
Schwan, M.A.2
-
46
-
-
0031105670
-
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
-
Tyler D.J., Durand D.M. A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves. IEEE Trans. Rehabil. Eng. 5:1997;51-61.
-
(1997)
IEEE Trans. Rehabil. Eng.
, vol.5
, pp. 51-61
-
-
Tyler, D.J.1
Durand, D.M.2
-
47
-
-
0017165586
-
Prediction of propagation block on the basis of impulse shape in single unit recordings from human nerves
-
Vallbo A.B. Prediction of propagation block on the basis of impulse shape in single unit recordings from human nerves. Acta Physiol. Scand. 97:1976;66-74.
-
(1976)
Acta Physiol. Scand.
, vol.97
, pp. 66-74
-
-
Vallbo, A.B.1
-
48
-
-
0018566312
-
Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves
-
Vallbo A.B., Hagbarth K.E., Torebjoerk H.E., Wallin B.G. Somatosensory, proprioceptive, and sympathetic activity in human peripheral nerves. Physiol. Rev. 59:1979;919-957.
-
(1979)
Physiol. Rev.
, vol.59
, pp. 919-957
-
-
Vallbo, A.B.1
Hagbarth, K.E.2
Torebjoerk, H.E.3
Wallin, B.G.4
-
50
-
-
0027717896
-
Selective control of muscle activation with a multipolar nerve cuff electrode
-
Veraart C., Grill W.M., Mortimer J.T. Selective control of muscle activation with a multipolar nerve cuff electrode. IEEE Trans. Biomed. Eng. 40:1993;640-653.
-
(1993)
IEEE Trans. Biomed. Eng.
, vol.40
, pp. 640-653
-
-
Veraart, C.1
Grill, W.M.2
Mortimer, J.T.3
-
51
-
-
0021920630
-
Microneurography and its relation to perceived sensation. A critical review
-
Wall P.D., McMahon S.B. Microneurography and its relation to perceived sensation. A critical review. Pain. 21:1985;209-229.
-
(1985)
Pain
, vol.21
, pp. 209-229
-
-
Wall, P.D.1
McMahon, S.B.2
-
52
-
-
0342788586
-
Direct membrane resting and action potential from single myelinated nerve fibers
-
Woodbury J.W. Direct membrane resting and action potential from single myelinated nerve fibers. J. Cell. Comp. Physiol. 39:1952;323-339.
-
(1952)
J. Cell. Comp. Physiol.
, vol.39
, pp. 323-339
-
-
Woodbury, J.W.1
-
53
-
-
0027588996
-
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
-
Yoshida K., Horch K. Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes. IEEE Trans. Biomed. Eng. 40:1993;492-494.
-
(1993)
IEEE Trans. Biomed. Eng.
, vol.40
, pp. 492-494
-
-
Yoshida, K.1
Horch, K.2
-
54
-
-
0030088097
-
Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation
-
Yoshida K., Horch K. Closed-loop control of ankle position using muscle afferent feedback with functional neuromuscular stimulation. IEEE Trans. Biomed. Eng. 43:1996;167-176.
-
(1996)
IEEE Trans. Biomed. Eng.
, vol.43
, pp. 167-176
-
-
Yoshida, K.1
Horch, K.2
-
55
-
-
0031260315
-
A single-channel implantable microstimulator for functional neuromuscular stimulation
-
Ziaie B., Nardin M.D., Coghlan A.R., Najafi K. A single-channel implantable microstimulator for functional neuromuscular stimulation. IEEE Trans. Biomed. Eng. 44:1997;909-920.
-
(1997)
IEEE Trans. Biomed. Eng.
, vol.44
, pp. 909-920
-
-
Ziaie, B.1
Nardin, M.D.2
Coghlan, A.R.3
Najafi, K.4
|