메뉴 건너뛰기




Volumn 35, Issue 4, 2019, Pages 16-33

Partial discharge detection and diagnosis in gas insulated switchgear: State of the art

Author keywords

detection methods; gas insulated switchgear; partial discharge; PD classification

Indexed keywords

ELECTRIC SWITCHGEAR; GASES; INSULATION; OUTAGES; PARTIAL DISCHARGES; SULFUR HEXAFLUORIDE;

EID: 85067365957     PISSN: 08837554     EISSN: 15584402     Source Type: Journal    
DOI: 10.1109/MEI.2019.8735667     Document Type: Article
Times cited : (130)

References (148)
  • 1
    • 67651111713 scopus 로고    scopus 로고
    • Life Management of SF6 Circuit Breakers based on Monitoring and Diagnosis
    • Z. Zhang, J. Zhang, E. Gockenbach, and H. Borsi, "Life Management of SF6 Circuit Breakers based on Monitoring and Diagnosis," IEEE Elec. Insul. Mag., vol. 25, no. 3, pp. 21-29, 2009.
    • (2009) IEEE Elec. Insul. Mag. , vol.25 , Issue.3 , pp. 21-29
    • Zhang, Z.1    Zhang, J.2    Gockenbach, E.3    Borsi, H.4
  • 2
    • 0028410148 scopus 로고
    • Assessing the risk of failure due to particle contamination of gis using the uhf technique
    • A. G. Sellars, O. Farish, and B. F. Hampton, "Assessing The Risk of Failure Due to Particle Contamination of GIS Using The UHF Technique," IEEE Trans. Dielectr. Electr. Insul., vol. 1, no. 2, pp. 323-331, 1994.
    • (1994) IEEE Trans. Dielectr. Electr. Insul. , vol.1 , Issue.2 , pp. 323-331
    • Sellars, A.G.1    Farish, O.2    Hampton, B.F.3
  • 3
    • 58149138785 scopus 로고    scopus 로고
    • Determination of a failure probability prognosis based on PD-Diagnostics in GIS
    • K. Dreisbusch, H. G. Kranz, and A. Schnettler, "Determination of a failure probability prognosis based on PD-Diagnostics in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 15, no. 6, pp. 1707-1714, 2008.
    • (2008) IEEE Trans. Dielectr. Electr. Insul. , vol.15 , Issue.6 , pp. 1707-1714
    • Dreisbusch, K.1    Kranz, H.G.2    Schnettler, A.3
  • 4
    • 84906318014 scopus 로고    scopus 로고
    • Gas-insulated and hybrid substations: Substation modernization in the Mexican petrochemical industry
    • Sep.
    • L. I. Ruiz Flores, N. A. Hernandez Munoz, I. Salazar Castro, and V. Martinez Torres, "Gas-insulated and hybrid substations: Substation modernization in the Mexican petrochemical industry," IEEE Ind. Appl. Mag., vol. 20, no. 5, pp. 64-70, Sep. 2014.
    • (2014) IEEE Ind. Appl. Mag. , vol.20 , Issue.5 , pp. 64-70
    • Ruiz Flores, L.I.1    Hernandez Munoz, N.A.2    Salazar Castro, I.3    Martinez Torres, V.4
  • 5
    • 84911885174 scopus 로고    scopus 로고
    • Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components
    • X. Zhang, H. Liu, J. Ren, J. Li, and X. Li, "Fourier transform infrared spectroscopy quantitative analysis of SF6 partial discharge decomposition components," Spectrochim. Acta-Part A Mol. Biomol. Spectrosc., vol. 136, no. PB, pp. 884-889, 2015.
    • (2015) Spectrochim. Acta-Part A Mol. Biomol. Spectrosc. , vol.136 , Issue.PB , pp. 884-889
    • Zhang, X.1    Liu, H.2    Ren, J.3    Li, J.4    Li, X.5
  • 6
    • 84986296780 scopus 로고    scopus 로고
    • State of the art in insulation of gas insulated substations: Main issues, achievements, and trends
    • G. Mazzanti, G. Stomeo, and S. Mancini, "State of the art in insulation of gas insulated substations: Main issues, achievements, and trends," IEEE Elec. Insul. Mag., vol. 32, no. 5, pp. 18-31, 2016.
    • (2016) IEEE Elec. Insul. Mag. , vol.32 , Issue.5 , pp. 18-31
    • Mazzanti, G.1    Stomeo, G.2    Mancini, S.3
  • 10
    • 0023834593 scopus 로고
    • A study on effects of conducting particles in SF6, gas and test methods for GIS
    • T. Hattori, M. Honda, H. Aoyagi, N. Kobayashi, and K. Terasaka, "A study on effects of conducting particles in SF6, gas and test methods for GIS," IEEE Trans. Power Deliv., vol. 3, no. 1, pp. 197-204, 1988.
    • (1988) IEEE Trans. Power Deliv. , vol.3 , Issue.1 , pp. 197-204
    • Hattori, T.1    Honda, M.2    Aoyagi, H.3    Kobayashi, N.4    Terasaka, K.5
  • 11
    • 0022865230 scopus 로고
    • Diagnostic methods for gas-insulated substations
    • Y. Takahashi, "Diagnostic methods for gas-insulated substations," IEEE Trans. Electr. Insul., vol. EI-21, no. 6, pp. 1037-1043, 1986.
    • (1986) IEEE Trans. Electr. Insul. , vol.EI-21 , Issue.6 , pp. 1037-1043
    • Takahashi, Y.1
  • 12
    • 0029254136 scopus 로고
    • On-line fault diagnosis of power substation using connectionist expert system
    • H. T. Yang, W. Y. Chang, and C. L. Huang, "On-line fault diagnosis of power substation using connectionist expert system," IEEE Trans. Power Syst., vol. 10, no. 1, pp. 323-331, 1995.
    • (1995) IEEE Trans. Power Syst. , vol.10 , Issue.1 , pp. 323-331
    • Yang, H.T.1    Chang, W.Y.2    Huang, C.L.3
  • 13
    • 0025383298 scopus 로고
    • Detection of Partial Discharges (Corona) in Electrical Apparatus
    • R. Bartnikas, "Detection of Partial Discharges (Corona) in Electrical Apparatus," IEEE Trans. Electr. Insul., vol. 25, no. 1, pp. 111-124, 1990.
    • (1990) IEEE Trans. Electr. Insul. , vol.25 , Issue.1 , pp. 111-124
    • Bartnikas, R.1
  • 15
    • 84924974508 scopus 로고    scopus 로고
    • Partial discharge classifications: Review of recent progress
    • May.
    • W. J. K. Raymond, H. A. Illias, A. H. A. Bakar, and H. Mokhlis, "Partial discharge classifications: Review of recent progress," Measurement, vol. 68, pp. 164-181, May. 2015.
    • (2015) Measurement , vol.68 , pp. 164-181
    • Raymond, W.J.K.1    Illias, H.A.2    Bakar, A.H.A.3    Mokhlis, H.4
  • 16
    • 0027808474 scopus 로고
    • Neural Networks as a Tool for Recognition of Partial Discharges
    • E. Gulski and A. Krivda, "Neural Networks as a Tool for Recognition of Partial Discharges," IEEE Trans. Electr. Insul., vol. 28, no. 6, pp. 984-1001, 1993.
    • (1993) IEEE Trans. Electr. Insul. , vol.28 , Issue.6 , pp. 984-1001
    • Gulski, E.1    Krivda, A.2
  • 17
    • 84960097967 scopus 로고    scopus 로고
    • Multiple partial discharge source discrimination with multiclass support vector machines
    • G. Robles, E. Parrado-Hernández, J. Ardila-Rey, and J. M. Martínez-Tarifa, "Multiple partial discharge source discrimination with multiclass support vector machines," Expert Syst. Appl., vol. 55, pp. 417-428, 2016.
    • (2016) Expert Syst. Appl. , vol.55 , pp. 417-428
    • Robles, G.1    Parrado-Hernández, E.2    Ardila-Rey, J.3    Martínez-Tarifa, J.M.4
  • 18
    • 0033741077 scopus 로고    scopus 로고
    • Application of genetic algorithms to pattern recognition of defects in GIS
    • W. Ziomek, M. Reformat, and E. Kuffel, "Application of genetic algorithms to pattern recognition of defects in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 7, no. 2, pp. 161-168, 2000.
    • (2000) IEEE Trans. Dielectr. Electr. Insul. , vol.7 , Issue.2 , pp. 161-168
    • Ziomek, W.1    Reformat, M.2    Kuffel, E.3
  • 19
    • 84946826810 scopus 로고    scopus 로고
    • An overview of state-of-the-art partial discharge analysis techniques for condition monitoring
    • M. Wu, H. Cao, J. Cao, H. L. Nguyen, J. B. Gomes, and S. P. Krishnaswamy, "An overview of state-of-the-art partial discharge analysis techniques for condition monitoring," IEEE Elec. Insul. Mag., vol. 31, no. 6, pp. 22-35, 2015.
    • (2015) IEEE Elec. Insul. Mag. , vol.31 , Issue.6 , pp. 22-35
    • Wu, M.1    Cao, H.2    Cao, J.3    Nguyen, H.L.4    Gomes, J.B.5    Krishnaswamy, S.P.6
  • 21
    • 85044113768 scopus 로고    scopus 로고
    • Recent trends in development of high voltage circuit breakers with SF6 alternative gases
    • M. Seeger, et al, "Recent Trends in Development of High Voltage Circuit Breakers with SF6 Alternative Gases," Plasma Phys. Technol. J., vol. 4, no. 1, pp. 18-22, 2017.
    • (2017) Plasma Phys. Technol. J. , vol.4 , Issue.1 , pp. 18-22
    • Seeger, M.1
  • 22
    • 0037252821 scopus 로고    scopus 로고
    • Condition Monitoring Techniques for Electrical Equipment - A Literature Survey
    • Y. Han and Y. H. Song, "Condition Monitoring Techniques for Electrical Equipment - A Literature Survey," IEEE Trans. Power Deliv., vol. 18, no. 1, pp. 4-13, 2003.
    • (2003) IEEE Trans. Power Deliv. , vol.18 , Issue.1 , pp. 4-13
    • Han, Y.1    Song, Y.H.2
  • 23
    • 0004001114 scopus 로고    scopus 로고
    • High voltage engineering, fundamentals
    • E. Kuffel, et al, "High Voltage Engineering, Fundamentals," High Volt. Eng., vol. 1, no. c, p. 552 2001.
    • (2001) High Volt. Eng. , vol.1 , Issue.C , pp. 552
    • Kuffel, E.1
  • 25
    • 79953183073 scopus 로고    scopus 로고
    • Recent trend and future perspectives in electrical insulation techniques in relation to sulfur hexafluoride (SF6) substitutes for high voltage electric power equipment
    • H. Okubo and A. Beroual, "Recent trend and future perspectives in electrical insulation techniques in relation to sulfur hexafluoride (SF6) substitutes for high voltage electric power equipment," IEEE Elec. Insul. Mag., vol. 27, no. 2, pp. 34-42, 2011.
    • (2011) IEEE Elec. Insul. Mag. , vol.27 , Issue.2 , pp. 34-42
    • Okubo, H.1    Beroual, A.2
  • 27
    • 34848909552 scopus 로고    scopus 로고
    • The decomposition products of sulfur hexafluoride (SF6): Reviews of environmental and health risk analysis
    • W.-T. T. Tsai, "The decomposition products of sulfur hexafluoride (SF6): Reviews of environmental and health risk analysis," J. Fluor. Chem., vol. 128, no. 11, pp. 1345-1352, 2007.
    • (2007) J. Fluor. Chem. , vol.128 , Issue.11 , pp. 1345-1352
    • Tsai, W.-T.T.1
  • 32
    • 85067363765 scopus 로고    scopus 로고
    • Effect of fixed copper particle on pd characteristcs of Sf6-N2 (10: 90) gas mixtures
    • B. R. Kamath and J. S. Rajan, "Effect of Fixed Copper Particle on PD Characteristcs of Sf6-N2 (10: 90) Gas Mixtures," Int. J. Electron. Eng. Res., vol. 1, no. 1, pp. 1-11, 2009.
    • (2009) Int. J. Electron. Eng. Res. , vol.1 , Issue.1 , pp. 1-11
    • Kamath, B.R.1    Rajan, J.S.2
  • 33
    • 0043064040 scopus 로고    scopus 로고
    • The influence of the dielectric strength of the N2/SF 6-insulation by conducting particle on the spacer surface
    • A. Moukengué Imano, "The influence of the dielectric strength of the N2/SF 6-insulation by conducting particle on the spacer surface," IEEE Trans. Dielectr. Electr. Insul., vol. 10, no. 3, pp. 483-490, 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , Issue.3 , pp. 483-490
    • Imano, A.M.1
  • 34
    • 85008065166 scopus 로고    scopus 로고
    • SF6 reclaimer from SF6/ N2 mixtures by gas separation with molecular sieving effect
    • M. Toyoda, et al, "SF6 Reclaimer from SF6/ N2 Mixtures by Gas Separation with Molecular Sieving Effect," IEEE Power Eng. Rev., vol. 22, no. 6, p. 61 2002.
    • (2002) IEEE Power Eng. Rev. , vol.22 , Issue.6 , pp. 61
    • Toyoda, M.1
  • 37
    • 0027004004 scopus 로고
    • Comparisons of direct-current breakdown characteristics in dry air and SF6 gaps using a parallelplane arrangement with variable height protrusion
    • K. Nishijima and I. Tsuneyasu, "Comparisons of direct-current breakdown characteristics in dry air and SF6 gaps using a parallelplane arrangement with variable height protrusion," Electr. Eng. Jpn., vol. 112, no. 7, pp. 46-54, 1992.
    • (1992) Electr. Eng. Jpn. , vol.112 , Issue.7 , pp. 46-54
    • Nishijima, K.1    Tsuneyasu, I.2
  • 39
    • 84945307476 scopus 로고    scopus 로고
    • Study on Oxygen / Nitrogen Gas Mixtures for the Surface Insulation Performance in Gas Insulated Switchgear
    • D. Lim and S. Bae, "Study on Oxygen / Nitrogen Gas Mixtures for the Surface Insulation Performance in Gas Insulated Switchgear," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 3, pp. 1567-1576, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul. , vol.22 , Issue.3 , pp. 1567-1576
    • Lim, D.1    Bae, S.2
  • 40
    • 84907012538 scopus 로고    scopus 로고
    • Partial discharges and breakdown in C3F8
    • M. Koch and C. M. Franck, "Partial discharges and breakdown in C3F8," J. Phys. D Appl. Phys., vol. 47, no. 40, 2014.
    • (2014) J. Phys. D Appl. Phys. , vol.47 , Issue.40
    • Koch, M.1    Franck, C.M.2
  • 41
    • 84961962653 scopus 로고    scopus 로고
    • Analysis of the feasibility of CF3I/CO2 used in C-GIS by partial discharge inception voltages in positive half cycle and breakdown voltages
    • X. Zhang, S. Xiao, Y. Han, and Q. Dai, "Analysis of the feasibility of CF3I/CO2 used in C-GIS by partial discharge inception voltages in positive half cycle and breakdown voltages," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 6, pp. 3234-3243, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul. , vol.22 , Issue.6 , pp. 3234-3243
    • Zhang, X.1    Xiao, S.2    Han, Y.3    Dai, Q.4
  • 42
    • 85014880777 scopus 로고    scopus 로고
    • Insulation Characteristics of c-C4F8-N2and CF3I-N2Mixtures as Possible Substitutes for SF6
    • Feb.
    • H. Zhao, X. Li, and H. Lin, "Insulation Characteristics of c-C4F8-N2and CF3I-N2Mixtures as Possible Substitutes for SF6," IEEE Trans. Power Deliv., vol. 32, no. 1, pp. 254-262, Feb. 2017.
    • (2017) IEEE Trans. Power Deliv. , vol.32 , Issue.1 , pp. 254-262
    • Zhao, H.1    Li, X.2    Lin, H.3
  • 43
    • 85034051379 scopus 로고    scopus 로고
    • Decomposition mechanism of the C5-PFK/CO 2 gas mixture as an alternative gas for SF 6
    • X. Zhang, et al, "Decomposition mechanism of the C5-PFK/CO 2 gas mixture as an alternative gas for SF 6," Chem. Eng. J., vol. 336, pp. 38-46, 2018.
    • (2018) Chem. Eng. J. , vol.336 , pp. 38-46
    • Zhang, X.1
  • 44
    • 0344081237 scopus 로고    scopus 로고
    • Status review on partial discharge measurement techniques in gas-insulated switchgear/lines
    • I. A. Metwally, "Status review on partial discharge measurement techniques in gas-insulated switchgear/lines," Electr. Power Syst. Res., vol. 69, no. 1, pp. 25-36, 2004.
    • (2004) Electr. Power Syst. Res. , vol.69 , Issue.1 , pp. 25-36
    • Metwally, I.A.1
  • 46
    • 0034171758 scopus 로고    scopus 로고
    • Dynamics of metallic particle contaminants in GIS with dielectric-coated electrodes
    • M. M. Morcos, S. Zhang, K. D. Srivastava, and S. M. Gubanski, "Dynamics of metallic particle contaminants in GIS with dielectric-coated electrodes," IEEE Trans. Power Deliv., vol. 15, no. 2, pp. 455-460, 2000.
    • (2000) IEEE Trans. Power Deliv. , vol.15 , Issue.2 , pp. 455-460
    • Morcos, M.M.1    Zhang, S.2    Srivastava, K.D.3    Gubanski, S.M.4
  • 47
    • 0026139640 scopus 로고
    • Development of preventive maintenance system for highly reliable gas insulated switchgear
    • T. Yamagiwa, H. Yamada, F. Endo, Y. Ohshita, S. Izumi, and I. Yamada, "Development of Preventive Maintenance System for Highly Reliable Gas Insulated Switchgear," IEEE Trans. Power Deliv., vol. 6, no. 2, pp. 840-848, 1991.
    • (1991) IEEE Trans. Power Deliv. , vol.6 , Issue.2 , pp. 840-848
    • Yamagiwa, T.1    Yamada, H.2    Endo, F.3    Ohshita, Y.4    Izumi, S.5    Yamada, I.6
  • 48
    • 77957005758 scopus 로고    scopus 로고
    • Thirty-Six Years of Service Experience with a National Population of Gas-Insulated Substations
    • M. Istad and M. Runde, "Thirty-Six Years of Service Experience with a National Population of Gas-Insulated Substations," IEEE Trans. Power Deliv., vol. 25, no. 4, pp. 2448-2454, 2010.
    • (2010) IEEE Trans. Power Deliv. , vol.25 , Issue.4 , pp. 2448-2454
    • Istad, M.1    Runde, M.2
  • 49
    • 84894442440 scopus 로고    scopus 로고
    • Uhf detection of partial discharge on typical defects in GIS
    • L. Dai, L. Liu, and C. Li, "Uhf detection of partial discharge on typical defects in GIS," Sensors and Transducers, vol. 160, no. 12, pp. 533-540, 2013.
    • (2013) Sensors and Transducers , vol.160 , Issue.12 , pp. 533-540
    • Dai, L.1    Liu, L.2    Li, C.3
  • 50
    • 85067336525 scopus 로고    scopus 로고
    • Application of PNN optimized by MEA in GIS partial discharge recognition
    • Y. Li, et al, "Application of PNN Optimized by MEA in GIS Partial Discharge Recognition," Adv. Eng. Res., vol. 141, pp. 652-657, 2017.
    • (2017) Adv. Eng. Res. , vol.141 , pp. 652-657
    • Li, Y.1
  • 51
    • 84947905543 scopus 로고    scopus 로고
    • Investigation of disc-type sensors using the UHF method to detect partial discharge in GIS
    • Y. Xu, W. Liu, and W. Gao, "Investigation of disc-type sensors using the UHF method to detect partial discharge in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 5, pp. 3019-3027, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul. , vol.22 , Issue.5 , pp. 3019-3027
    • Xu, Y.1    Liu, W.2    Gao, W.3
  • 52
    • 36448961281 scopus 로고    scopus 로고
    • Thermal stability of SF6 associated with metallic conductors incorporated in gas insulated switchgear power substations
    • C. T. Dervos, P. Vassiliou, and J. A. Mergos, "Thermal stability of SF6 associated with metallic conductors incorporated in gas insulated switchgear power substations," J. Phys. D Appl. Phys., vol. 40, no. 22, pp. 6942-6952, 2007.
    • (2007) J. Phys. D Appl. Phys. , vol.40 , Issue.22 , pp. 6942-6952
    • Dervos, C.T.1    Vassiliou, P.2    Mergos, J.A.3
  • 53
    • 22044449245 scopus 로고    scopus 로고
    • Temperature rise prediction of EHV GIS bus bar by coupled magnetothermal finite element method
    • J. K. Kim, S. C. Hahn, K. Y. Park, H. K. Kim, and Y. H. Oh, "Temperature rise prediction of EHV GIS bus bar by coupled magnetothermal finite element method," IEEE Trans. Magn., vol. 41, no. 5, pp. 1636-1639, 2005.
    • (2005) IEEE Trans. Magn. , vol.41 , Issue.5 , pp. 1636-1639
    • Kim, J.K.1    Hahn, S.C.2    Park, K.Y.3    Kim, H.K.4    Oh, Y.H.5
  • 54
    • 85061747523 scopus 로고    scopus 로고
    • The method for measuring the loop resistance and the temperature rise calculation of gis conductor pole
    • L. Zhou, T. Lu, and B. Zhang, "The Method for Measuring the Loop Resistance and the Temperature Rise Calculation of GIS Conductor Pole," J. Power Energy Eng., vol. 03, no. 04, pp. 306-312, 2015.
    • (2015) J. Power Energy Eng. , vol.3 , Issue.4 , pp. 306-312
    • Zhou, L.1    Lu, T.2    Zhang, B.3
  • 55
    • 84973499920 scopus 로고    scopus 로고
    • Influence of voltage waveforms on partial discharge characteristics of protrusion defect in GIS
    • H. X. Ji, G. M. Ma, C. R. Li, Z. K. Pang, and S. S. Zheng, "Influence of voltage waveforms on partial discharge characteristics of protrusion defect in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 23, no. 2, pp. 1058-1067, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul. , vol.23 , Issue.2 , pp. 1058-1067
    • Ji, H.X.1    Ma, G.M.2    Li, C.R.3    Pang, Z.K.4    Zheng, S.S.5
  • 56
    • 84971468788 scopus 로고    scopus 로고
    • A wireless and passive online temperature monitoring system for gis based on surface-acoustic-wave sensor
    • G. M. Ma, et al, "A Wireless and Passive Online Temperature Monitoring System for GIS Based on Surface-Acoustic-Wave Sensor," IEEE Trans. Power Deliv., vol. 31, no. 3, pp. 1270-1280, 2016.
    • (2016) IEEE Trans. Power Deliv. , vol.31 , Issue.3 , pp. 1270-1280
    • Ma, G.M.1
  • 57
    • 85010379009 scopus 로고    scopus 로고
    • Moving behaviors and harmfulness analysis of multiple linear metal particles in GIS
    • H. Ji, et al, "Moving behaviors and harmfulness analysis of multiple linear metal particles in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 23, no. 6, pp. 3355-3363, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul. , vol.23 , Issue.6 , pp. 3355-3363
    • Ji, H.1
  • 58
    • 51849111551 scopus 로고    scopus 로고
    • Experiences in on-site partial discharge measurements and prospects for PD monitoring
    • K. Rethmeier, et al, "Experiences in on-site partial discharge measurements and prospects for PD monitoring," Proc. 2008 Int. Conf. Cond. Monit. Diagnosis, C. 2008, pp. 1279-1283, 2007.
    • (2007) Proc. 2008 Int. Conf. Cond. Monit. Diagnosis, C. 2008 , pp. 1279-1283
    • Rethmeier, K.1
  • 59
    • 84925967543 scopus 로고    scopus 로고
    • Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment
    • Mar.
    • F. Álvarez, F. Garnacho, J. Ortego, and M. Á. Sánchez-Urán, "Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment," Sensors (Switzerland), vol. 15, no. 4, pp. 7360-7387, Mar. 2015.
    • (2015) Sensors (Switzerland) , vol.15 , Issue.4 , pp. 7360-7387
    • Álvarez, F.1    Garnacho, F.2    Ortego, J.3    Sánchez-Urán, M.Á.4
  • 60
    • 6044264182 scopus 로고
    • Partial Discharge - Part IX: PD in Gas-Insulated Substations - Fundamental Considerations
    • R. Baumgartner, B. Fruth, W. Lanz, and K. Pettersson, "Partial Discharge - Part IX: PD in Gas-Insulated Substations - Fundamental Considerations," IEEE Elec. Insul. Mag., vol. 7, no. 6, pp. 5-13, 1991.
    • (1991) IEEE Elec. Insul. Mag. , vol.7 , Issue.6 , pp. 5-13
    • Baumgartner, R.1    Fruth, B.2    Lanz, W.3    Pettersson, K.4
  • 61
    • 84861497745 scopus 로고    scopus 로고
    • Characterization of metallic-particle dynamics in compressed SF 6-insulated systems under different voltage stresses
    • L. A. Metwally and A. A. A-Rahim, "Characterization of metallic-particle dynamics in compressed SF 6-insulated systems under different voltage stresses," in 2003 IEEE Bologna PowerTech-Conference Proceedings, 2003, vol. 2, pp. 107-112.
    • (2003) 2003 IEEE Bologna PowerTech-Conference Proceedings , vol.2 , pp. 107-112
    • Metwally, L.A.1    A-Rahim, A.A.2
  • 62
    • 0026223049 scopus 로고
    • Metallic particle movement, corona, and breakdown in compressed gas insulated transmission line systems
    • M. M. Morcos, H. I. Anis, and K. D. Srivastava, "Metallic Particle Movement, Corona, and Breakdown in Compressed Gas Insulated Transmission Line Systems," IEEE Trans. Ind. Appl., vol. 27, no. 5, pp. 816-823, 1991.
    • (1991) IEEE Trans. Ind. Appl. , vol.27 , Issue.5 , pp. 816-823
    • Morcos, M.M.1    Anis, H.I.2    Srivastava, K.D.3
  • 63
    • 28744439467 scopus 로고    scopus 로고
    • Degradation of solid dielectrics due to internal partial discharge: Some thoughts on progress made and where to go now
    • P. H. F. Morshuis, "Degradation of solid dielectrics due to internal partial discharge: Some thoughts on progress made and where to go now," IEEE Trans. Dielectr. Electr. Insul., vol. 12, no. 5, pp. 905-913, 2005.
    • (2005) IEEE Trans. Dielectr. Electr. Insul. , vol.12 , Issue.5 , pp. 905-913
    • Morshuis, P.H.F.1
  • 65
    • 0026898607 scopus 로고
    • Detection of partial discharges in gas insulated substations
    • A. Bargigia, W. Koltunowicz, and A. Pigin, "Detection of partial discharges in gas insulated substations," IEEE Trans. Power Deliv., vol. 7, no. 3, pp. 1239-1249, 1992.
    • (1992) IEEE Trans. Power Deliv. , vol.7 , Issue.3 , pp. 1239-1249
    • Bargigia, A.1    Koltunowicz, W.2    Pigin, A.3
  • 66
    • 85015771946 scopus 로고    scopus 로고
    • Influence of tip corona of free particle on PD patterns in GIS
    • H. X. Ji, et al, "Influence of tip corona of free particle on PD patterns in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 24, no. 1, pp. 259-267, 2017.
    • (2017) IEEE Trans. Dielectr. Electr. Insul. , vol.24 , Issue.1 , pp. 259-267
    • Ji, H.X.1
  • 67
    • 84859295093 scopus 로고    scopus 로고
    • Ultra-wide bandwidth measurement of partial discharge current pulses in SF 6
    • A. J. Reid and M. D. Judd, "Ultra-wide bandwidth measurement of partial discharge current pulses in SF 6," J. Phys. D Appl. Phys., vol. 45, no. 16, 2012.
    • (2012) J. Phys. D Appl. Phys. , vol.45 , Issue.16
    • Reid, A.J.1    Judd, M.D.2
  • 68
    • 84947810603 scopus 로고    scopus 로고
    • Study on miniaturized UHF antennas for partial discharge detection in high-voltage electrical equipment
    • J. Liu, G. Zhang, J. Dong, and J. Wang, "Study on miniaturized UHF antennas for partial discharge detection in high-voltage electrical equipment," Sensors (Switzerland), vol. 15, no. 11, pp. 29434-29451, 2015.
    • (2015) Sensors (Switzerland) , vol.15 , Issue.11 , pp. 29434-29451
    • Liu, J.1    Zhang, G.2    Dong, J.3    Wang, J.4
  • 69
    • 84986882188 scopus 로고    scopus 로고
    • Partial discharge occurrence induced by crack defect on GIS insulator operated at 1100 kV
    • H. X. Ji, et al, "Partial discharge occurrence induced by crack defect on GIS insulator operated at 1100 kV," IEEE Trans. Dielectr. Electr. Insul., vol. 23, no. 4, pp. 2250-2257, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul. , vol.23 , Issue.4 , pp. 2250-2257
    • Ji, H.X.1
  • 70
    • 84971321395 scopus 로고    scopus 로고
    • Measurement and analysis of partial discharges in SF6 gas under HVDC
    • G. Wang, H.-E. Jo, S.-J. Kim, S.-W. Kim, and G.-S. Kil, "Measurement and analysis of partial discharges in SF6 gas under HVDC," Meas. J. Int. Meas. Confed., vol. 91, pp. 351-359, 2016.
    • (2016) Meas. J. Int. Meas. Confed. , vol.91 , pp. 351-359
    • Wang, G.1    Jo, H.-E.2    Kim, S.-J.3    Kim, S.-W.4    Kil, G.-S.5
  • 72
    • 0029322314 scopus 로고
    • Using the UHF technique to investigate pd produced by defects in solid insulation
    • A. G. Sellars, O. Farish, B. F. Hampton, and L. S. Pritchard, "Using the UHF Technique to Investigate PD Produced by Defects in Solid Insulation," IEEE Trans. Dielectr. Electr. Insul., vol. 2, no. 3, pp. 448-459, 1995.
    • (1995) IEEE Trans. Dielectr. Electr. Insul. , vol.2 , Issue.3 , pp. 448-459
    • Sellars, A.G.1    Farish, O.2    Hampton, B.F.3    Pritchard, L.S.4
  • 73
    • 84864653939 scopus 로고    scopus 로고
    • The comparison of sensitivity between the UHF and ultrasonic methods for partial discharge detecting in GIS
    • B. Geng, C. Li, B. Qi, L. Yu, and J. Gao, "The comparison of sensitivity between the UHF and ultrasonic methods for partial discharge detecting in GIS," Annu. Rep.-Conf. Electr. Insul. Dielectr. Phenomena, CEIDP, pp. 468-471, 2011.
    • (2011) Annu. Rep.-Conf. Electr. Insul. Dielectr. Phenomena, CEIDP , pp. 468-471
    • Geng, B.1    Li, C.2    Qi, B.3    Yu, L.4    Gao, J.5
  • 74
    • 84982144425 scopus 로고    scopus 로고
    • UHF partial discharge detection system for GIS: Application guide for sensitivity verification: CIGRE WG D1.25
    • U. Schichler, et al, "UHF partial discharge detection system for GIS: Application guide for sensitivity verification: CIGRE WG D1.25," IEEE Trans. Dielectr. Electr. Insul., vol. 23, no. 3, pp. 1313-1321, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul. , vol.23 , Issue.3 , pp. 1313-1321
    • Schichler, U.1
  • 75
    • 33750096816 scopus 로고    scopus 로고
    • Comparison of sensitivity between UHF method and IEC 60270 for onsite calibration in various GIS
    • T. Hoshino, H. Koyama, S. Maruyama, and M. Hanai, "Comparison of sensitivity between UHF method and IEC 60270 for onsite calibration in various GIS," IEEE Trans. Power Deliv., vol. 21, no. 4, pp. 1948-1953, 2006.
    • (2006) IEEE Trans. Power Deliv. , vol.21 , Issue.4 , pp. 1948-1953
    • Hoshino, T.1    Koyama, H.2    Maruyama, S.3    Hanai, M.4
  • 76
    • 20744453841 scopus 로고    scopus 로고
    • UHF defect evaluation in gas insulated equipment
    • S. Meijer and J. J. Smit, "UHF defect evaluation in gas insulated equipment," IEEE Trans. Dielectr. Electr. Insul., vol. 12, no. 2, pp. 285-296, 2005.
    • (2005) IEEE Trans. Dielectr. Electr. Insul. , vol.12 , Issue.2 , pp. 285-296
    • Meijer, S.1    Smit, J.J.2
  • 77
    • 0032186852 scopus 로고    scopus 로고
    • UHF partial discharge monitoring and expert system diagnosis
    • T. Huecker and J. Gorablenkow, "UHF partial discharge monitoring and expert system diagnosis," IEEE Trans. Power Deliv., vol. 13, no. 4, pp. 1162-1167, 1998.
    • (1998) IEEE Trans. Power Deliv. , vol.13 , Issue.4 , pp. 1162-1167
    • Huecker, T.1    Gorablenkow, J.2
  • 79
    • 84862677617 scopus 로고    scopus 로고
    • Sensitivity comparison of disc-and loop-type sensors using the UHF method to detect partial discharges in GIS
    • T. Hoshino, S. Maruyama, S. Ohtsuka, M. Hikita, J. Wada, and S. Okabe, "Sensitivity comparison of disc-and loop-type sensors using the UHF method to detect partial discharges in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 19, no. 3, pp. 910-916, 2012.
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , Issue.3 , pp. 910-916
    • Hoshino, T.1    Maruyama, S.2    Ohtsuka, S.3    Hikita, M.4    Wada, J.5    Okabe, S.6
  • 80
    • 84864947648 scopus 로고    scopus 로고
    • Development simulation and experiment study on UHF partial discharge sensor in GIS
    • T. Li, M. Rong, C. Zheng, and X. Wang, "Development simulation and experiment study on UHF partial discharge sensor in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 19, no. 4, pp. 1421-1430, 2012.
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , Issue.4 , pp. 1421-1430
    • Li, T.1    Rong, M.2    Zheng, C.3    Wang, X.4
  • 81
    • 85008042407 scopus 로고    scopus 로고
    • High-voltage on-site commissioning tests for gas-insulated substations using UHF partial discharge detection
    • R. Bell, C. Charlson, S. Halliday, T. Irwin, J. Lopez-Roldan, and J. Nixon, "High-Voltage On-Site Commissioning Tests for Gas-Insulated Substations Using UHF Partial Discharge Detection," IEEE Power Eng. Rev., vol. 22, no. 6, p. 612002.
    • IEEE Power Eng. Rev. , vol.22 , Issue.6 , pp. 612002
    • Bell, R.1    Charlson, C.2    Halliday, S.3    Irwin, T.4    Lopez-Roldan, J.5    Nixon, J.6
  • 82
    • 84903792666 scopus 로고    scopus 로고
    • Partial discharge pattern of various defects measured by spiral antenna as UHF external sensor on 66 kV GIS model
    • U. Khayam, et al, "Partial discharge pattern of various defects measured by spiral antenna as UHF external sensor on 66 kV GIS model," Int. J. Electr. Eng. Informatics, vol. 6, no. 2, pp. 404-420, 2014.
    • (2014) Int. J. Electr. Eng. Informatics , vol.6 , Issue.2 , pp. 404-420
    • Khayam, U.1
  • 83
    • 0029249025 scopus 로고
    • UHF detection of leader discharges in SF6
    • M. M. Peterson, "UHF Detection of Leader Discharges in SF6," IEEE Trans. Dielectr. Electr. Insul., vol. 2, no. 1, pp. 143-154, 1995.
    • (1995) IEEE Trans. Dielectr. Electr. Insul. , vol.2 , Issue.1 , pp. 143-154
    • Peterson, M.M.1
  • 84
    • 80054081620 scopus 로고    scopus 로고
    • Research on the typical partial discharge using the uhf detection method for GIS
    • W. Gao, D. Ding, and W. Liu, "Research on the typical partial discharge using the uhf detection method for GIS," IEEE Trans. Power Deliv., vol. 26, no. 4, pp. 2621-2629, 2011.
    • (2011) IEEE Trans. Power Deliv. , vol.26 , Issue.4 , pp. 2621-2629
    • Gao, W.1    Ding, D.2    Liu, W.3
  • 86
    • 55149118716 scopus 로고    scopus 로고
    • Application of complex wavelet transform to suppress white noise in GIS UHF PD signals
    • X. Zhongrong, T. Ju, and S. Caixin, "Application of complex wavelet transform to suppress white noise in GIS UHF PD signals," IEEE Trans. Power Deliv., vol. 22, no. 3, pp. 1498-1504, 2007.
    • (2007) IEEE Trans. Power Deliv. , vol.22 , Issue.3 , pp. 1498-1504
    • Zhongrong, X.1    Ju, T.2    Caixin, S.3
  • 87
    • 45849152625 scopus 로고    scopus 로고
    • Detection of harmful metallic particles inside gas insulated switchgear using UHF sensor
    • S. Okabe, T. Yamagiwa, and H. Okubo, "Detection of harmful metallic particles inside gas insulated switchgear using UHF sensor," IEEE Trans. Dielectr. Electr. Insul., vol. 15, no. 3, pp. 701-709, 2008.
    • (2008) IEEE Trans. Dielectr. Electr. Insul. , vol.15 , Issue.3 , pp. 701-709
    • Okabe, S.1    Yamagiwa, T.2    Okubo, H.3
  • 88
    • 3242804456 scopus 로고    scopus 로고
    • Real-time PD identification in diagnosis of GIS using symmetric and asymmetric UHF sensors
    • T. Hoshino, K. Nojima, and M. Hanai, "Real-time PD identification in diagnosis of GIS using symmetric and asymmetric UHF sensors," IEEE Trans. Power Deliv., vol. 19, no. 3, pp. 1072-1077, 2004.
    • (2004) IEEE Trans. Power Deliv. , vol.19 , Issue.3 , pp. 1072-1077
    • Hoshino, T.1    Nojima, K.2    Hanai, M.3
  • 89
    • 79953676042 scopus 로고    scopus 로고
    • Evaluation of UHF method for partial discharge measurement by simultaneous observation of UHF signal and current pulse waveforms
    • M. Yoshida, H. Kojima, N. Hayakawa, F. Endo, and H. Okubo, "Evaluation of UHF method for partial discharge measurement by simultaneous observation of UHF signal and current pulse waveforms," IEEE Trans. Dielectr. Electr. Insul., vol. 18, no. 2, pp. 425-431, 2011.
    • (2011) IEEE Trans. Dielectr. Electr. Insul. , vol.18 , Issue.2 , pp. 425-431
    • Yoshida, M.1    Kojima, H.2    Hayakawa, N.3    Endo, F.4    Okubo, H.5
  • 90
    • 85038077034 scopus 로고    scopus 로고
    • Study of comparison between Ultra-high Frequency (UHF) method and ultrasonic method on PD detection for GIS
    • Nov.
    • Y. Li, D. Chen, L. Li, J. Zhang, G. Li, and H. Liu, "Study of comparison between Ultra-high Frequency (UHF) method and ultrasonic method on PD detection for GIS," IOP Conf. Ser. Earth Environ. Sci., vol. 94, p. 012086, Nov. 2017.
    • (2017) IOP Conf. Ser. Earth Environ. Sci. , vol.94 , pp. 012086
    • Li, Y.1    Chen, D.2    Li, L.3    Zhang, J.4    Li, G.5    Liu, H.6
  • 91
    • 84863358483 scopus 로고    scopus 로고
    • Detection of partial discharge in SF6 decomposition gas based on modified carbon nanotubes sensors
    • X. Zhang, B. Yang, W. Liu, and J. Zhang, "Detection of Partial Discharge in SF6 Decomposition Gas Based on Modified Carbon Nanotubes Sensors," Procedia Eng., vol. 29, pp. 4107-4111, 2012.
    • (2012) Procedia Eng. , vol.29 , pp. 4107-4111
    • Zhang, X.1    Yang, B.2    Liu, W.3    Zhang, J.4
  • 92
    • 0035909252 scopus 로고    scopus 로고
    • Estimation of partial discharge parameters in GIS using acoustic emission techniques
    • N. Gupta and T. S. Ramu, "Estimation of partial discharge parameters in GIS using acoustic emission techniques," J. Sound Vibrat., vol. 247, no. 2, pp. 243-260, 2001.
    • (2001) J. Sound Vibrat. , vol.247 , Issue.2 , pp. 243-260
    • Gupta, N.1    Ramu, T.S.2
  • 93
    • 84898687493 scopus 로고    scopus 로고
    • Partial discharge initiated by free moving metallic particles on GIS insulator surface: Severity diagnosis and assessment
    • B. Qi, C. Li, Z. Xing, and Z. Wei, "Partial discharge initiated by free moving metallic particles on GIS insulator surface: Severity diagnosis and assessment," IEEE Trans. Dielectr. Electr. Insul., vol. 21, no. 2, pp. 766-774, 2014.
    • (2014) IEEE Trans. Dielectr. Electr. Insul. , vol.21 , Issue.2 , pp. 766-774
    • Qi, B.1    Li, C.2    Xing, Z.3    Wei, Z.4
  • 94
    • 73649140236 scopus 로고    scopus 로고
    • Application of grey clustering approach and genetic algorithm to partial discharge pattern recognition
    • W. Chang, "Application of Grey Clustering Approach and Genetic Algorithm to Partial Discharge Pattern Recognition," WSEAS Trans. Syst., vol. 8, no. 12, pp. 1273-1283, 2009.
    • (2009) WSEAS Trans. Syst. , vol.8 , Issue.12 , pp. 1273-1283
    • Chang, W.1
  • 96
    • 84898681868 scopus 로고    scopus 로고
    • GIS partial discharge pattern recognition based on the chaos theory
    • X. Zhang, S. Xiao, N. Shu, J. Tang, and W. Li, "GIS partial discharge pattern recognition based on the chaos theory," IEEE Trans. Dielectr. Electr. Insul., vol. 21, no. 2, pp. 783-790, 2014.
    • (2014) IEEE Trans. Dielectr. Electr. Insul. , vol.21 , Issue.2 , pp. 783-790
    • Zhang, X.1    Xiao, S.2    Shu, N.3    Tang, J.4    Li, W.5
  • 97
    • 84898999482 scopus 로고    scopus 로고
    • Classification of partial discharge events in GILBS using probabilistic neural networks and the fuzzy c-means clustering approach
    • M.-S. S. Su, C.-C. C. Chia, C.-Y. Y. Chen, and J.-F. F. Chen, "Classification of partial discharge events in GILBS using probabilistic neural networks and the fuzzy c-means clustering approach," Int. J. Electr. Power Energy Syst., vol. 61, pp. 173-179, 2014.
    • (2014) Int. J. Electr. Power Energy Syst. , vol.61 , pp. 173-179
    • Su, M.-S.S.1    Chia, C.-C.C.2    Chen, C.-Y.Y.3    Chen, J.-F.F.4
  • 98
    • 84923107842 scopus 로고    scopus 로고
    • Partial discharge analysis of gas insulated systems at high voltage AC and DC
    • R. Piccin, A. Mor, P. Morshuis, A. Girodet, and J. Smit, "Partial discharge analysis of gas insulated systems at high voltage AC and DC," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 1, pp. 218-228, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul. , vol.22 , Issue.1 , pp. 218-228
    • Piccin, R.1    Mor, A.2    Morshuis, P.3    Girodet, A.4    Smit, J.5
  • 100
    • 0037732564 scopus 로고    scopus 로고
    • Wavelet-based denoising of partial discharge signals buried in excessive noise and interference
    • Apr.
    • L. Satish and B. Nazneen, "Wavelet-based denoising of partial discharge signals buried in excessive noise and interference," IEEE Trans. Dielectr. Electr. Insul., vol. 10, no. 2, pp. 354-367, Apr. 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul. , vol.10 , Issue.2 , pp. 354-367
    • Satish, L.1    Nazneen, B.2
  • 101
    • 78651500131 scopus 로고    scopus 로고
    • Feature extraction of partial discharge signals using the wavelet packet transform and classification with a probabilistic neural network
    • D. Evagorou, et al, "Feature extraction of partial discharge signals using the wavelet packet transform and classification with a probabilistic neural network," IET Sci. Measur. Technol., vol. 4, no. 3, p. 177 2010.
    • (2010) IET Sci. Measur. Technol. , vol.4 , Issue.3 , pp. 177
    • Evagorou, D.1
  • 104
    • 84919674755 scopus 로고    scopus 로고
    • Review on partial discharge detection techniques related to high voltage power equipment using different sensors
    • M. M. Yaacob, M. A. Alsaedi, J. R. Rashed, A. M. Dakhil, and S. F. Atyah, "Review on partial discharge detection techniques related to high voltage power equipment using different sensors," Photonic Sens., vol. 4, no. 4, pp. 325-337, 2014.
    • (2014) Photonic Sens. , vol.4 , Issue.4 , pp. 325-337
    • Yaacob, M.M.1    Alsaedi, M.A.2    Rashed, J.R.3    Dakhil, A.M.4    Atyah, S.F.5
  • 105
    • 0036464576 scopus 로고    scopus 로고
    • Analysis and design of two-arm conical spiral antennas
    • T. W. Hertel and G. S. Smith, "Analysis and design of two-arm conical spiral antennas," IEEE Trans. Electromagn. Compat., vol. 44, no. 1, pp. 25-37, 2002.
    • (2002) IEEE Trans. Electromagn. Compat. , vol.44 , Issue.1 , pp. 25-37
    • Hertel, T.W.1    Smith, G.S.2
  • 108
    • 85018952662 scopus 로고    scopus 로고
    • UHF moore fractal antennas for online GIS PD detection
    • Y. Wang, Z. Wang, and J. Li, "UHF Moore Fractal Antennas for Online GIS PD Detection," IEEE Antennas Wirel. Propag. Lett., vol. 16, pp. 852-855, 2017.
    • (2017) IEEE Antennas Wirel. Propag. Lett. , vol.16 , pp. 852-855
    • Wang, Y.1    Wang, Z.2    Li, J.3
  • 109
    • 84878475598 scopus 로고    scopus 로고
    • Analysis of the intrinsic characteristics of the partial discharge induced by typical defects in GIS
    • W. Gao, D. Ding, W. Liu, and X. Huang, "Analysis of the intrinsic characteristics of the partial discharge induced by typical defects in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 20, no. 3, pp. 782-790, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul. , vol.20 , Issue.3 , pp. 782-790
    • Gao, W.1    Ding, D.2    Liu, W.3    Huang, X.4
  • 110
    • 35348893998 scopus 로고    scopus 로고
    • Electromagnetic wave propagation in a coaxial pipe GIS model
    • S. Okabe and S. Kaneko, "Electromagnetic wave propagation in a coaxial pipe GIS model," IEEE Trans. Dielectr. Electr. Insul., vol. 14, no. 5, pp. 1161-1169, 2007.
    • (2007) IEEE Trans. Dielectr. Electr. Insul. , vol.14 , Issue.5 , pp. 1161-1169
    • Okabe, S.1    Kaneko, S.2
  • 111
    • 84885638561 scopus 로고    scopus 로고
    • Propagation attenuation properties of partial discharge in typical in-field GIS structures
    • W. Gao, D. Ding, W. Liu, and X. Huang, "Propagation attenuation properties of partial discharge in typical in-field GIS structures," IEEE Trans. Power Deliv., vol. 28, no. 4, pp. 2540-2549, 2013.
    • (2013) IEEE Trans. Power Deliv. , vol.28 , Issue.4 , pp. 2540-2549
    • Gao, W.1    Ding, D.2    Liu, W.3    Huang, X.4
  • 112
    • 84863136548 scopus 로고    scopus 로고
    • Influence of GIS structure on propagation of electromagnetic waves of partial discharge
    • Q. Li, et al, "Influence of GIS structure on propagation of electromagnetic waves of partial discharge," in PEAM 2011-Proceedings: 2011 IEEE Power Engineering and Automation Conference, 2011, vol. 2, pp. 128-135.
    • (2011) PEAM 2011-Proceedings: 2011 IEEE Power Engineering and Automation Conference , vol.2 , pp. 128-135
    • Li, Q.1
  • 113
    • 84982273850 scopus 로고    scopus 로고
    • Investigation on polarization characteristics of PD-induced electromagnetic wave leakage in GIS with metal belt
    • H. Guo, H. Qiu, L. Yao, F. Huang, and K. F. Ren, "Investigation on polarization characteristics of PD-induced electromagnetic wave leakage in GIS with metal belt," IEEE Trans. Dielectr. Electr. Insul., vol. 23, no. 3, pp. 1475-1481, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul. , vol.23 , Issue.3 , pp. 1475-1481
    • Guo, H.1    Qiu, H.2    Yao, L.3    Huang, F.4    Ren, K.F.5
  • 114
    • 0024479945 scopus 로고
    • On-line monitoring and diagnostics of gas circuit breakers
    • K. Goto, T. Sakakibara, I. Kamata, and S. Ikeda, "On-line monitoring and diagnostics of gas circuit breakers," IEEE Trans. Power Deliv., vol. 4, no. 1, pp. 375-381, 1989.
    • (1989) IEEE Trans. Power Deliv. , vol.4 , Issue.1 , pp. 375-381
    • Goto, K.1    Sakakibara, T.2    Kamata, I.3    Ikeda, S.4
  • 115
    • 84903191103 scopus 로고    scopus 로고
    • Investigation on the placement effect of UHF sensor and propagation characteristics of PD-induced electromagnetic wave in GIS based on FDTD method
    • Jun.
    • T. Li, X. Wang, C. Zheng, D. Liu, and M. Rong, "Investigation on the placement effect of UHF sensor and propagation characteristics of PD-induced electromagnetic wave in GIS based on FDTD method," IEEE Trans. Dielectr. Electr. Insul., vol. 21, no. 3, pp. 1015-1025, Jun. 2014.
    • (2014) IEEE Trans. Dielectr. Electr. Insul. , vol.21 , Issue.3 , pp. 1015-1025
    • Li, T.1    Wang, X.2    Zheng, C.3    Liu, D.4    Rong, M.5
  • 116
    • 84907342212 scopus 로고    scopus 로고
    • Simulation and measurement of PD-induced electromagnetic wave leakage in GIS with metal belt
    • H. Guo, F. Lü, and K. Ren, "Simulation and measurement of PD-induced electromagnetic wave leakage in GIS with metal belt," IEEE Trans. Dielectr. Electr. Insul., vol. 21, no. 4, pp. 1942-1949, 2014.
    • (2014) IEEE Trans. Dielectr. Electr. Insul. , vol.21 , Issue.4 , pp. 1942-1949
    • Guo, H.1    Lü, F.2    Ren, K.3
  • 117
    • 0030127101 scopus 로고    scopus 로고
    • The excitation of UHF signals by partial discharges in GIS
    • M. D. Judd, O. Farish, and B. F. Hampton, "The excitation of UHF signals by partial discharges in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 3, no. 2, pp. 213-228, 1996.
    • (1996) IEEE Trans. Dielectr. Electr. Insul. , vol.3 , Issue.2 , pp. 213-228
    • Judd, M.D.1    Farish, O.2    Hampton, B.F.3
  • 118
    • 85046760397 scopus 로고    scopus 로고
    • A novel GIS partial discharge detection sensor with integrated optical and UHF methods
    • J. Li, H. Xutao, Z. Liu, and X. Yao, "A Novel GIS Partial Discharge Detection Sensor with Integrated Optical and UHF Methods," IEEE Trans. Power Deliv., vol. 8977, no. c, pp. 1-1, 2016.
    • (2016) IEEE Trans. Power Deliv. , vol.8977 , Issue.C , pp. 1
    • Li, J.1    Xutao, H.2    Liu, Z.3    Yao, X.4
  • 119
    • 0025502877 scopus 로고
    • Acoustic diagnosis of gas insulated substations: A theoretical and experimental basis
    • L. E. Lundgaard, M. Runde, and B. Skyberg, "Acoustic diagnosis of gas insulated substations: a theoretical and experimental basis," IEEE Trans. Power Deliv., vol. 5, no. 4, pp. 1751-1759, 1990.
    • (1990) IEEE Trans. Power Deliv. , vol.5 , Issue.4 , pp. 1751-1759
    • Lundgaard, L.E.1    Runde, M.2    Skyberg, B.3
  • 120
    • 27744532945 scopus 로고    scopus 로고
    • A novel technique for partial discharge and breakdown investigation based on current pulse waveform analysis
    • H. Okubo and N. Hayakawa, "A novel technique for partial discharge and breakdown investigation based on current pulse waveform analysis," IEEE Trans. Dielectr. Electr. Insul., vol. 12, no. 4, pp. 736-744, 2005.
    • (2005) IEEE Trans. Dielectr. Electr. Insul. , vol.12 , Issue.4 , pp. 736-744
    • Okubo, H.1    Hayakawa, N.2
  • 121
    • 85008023942 scopus 로고    scopus 로고
    • Health monitoring and prognostics of electronics subject to vibration load conditions
    • J. Gu, D. Barker, and M. Pecht, "Health Monitoring and Prognostics of Electronics Subject to Vibration Load Conditions," Sensors Journal, IEEE, vol. 9, no. 11, pp. 1479-1485, 2009.
    • (2009) Sensors Journal, IEEE , vol.9 , Issue.11 , pp. 1479-1485
    • Gu, J.1    Barker, D.2    Pecht, M.3
  • 122
    • 0025418682 scopus 로고
    • Optical discharge detection in sf6-insulated systems
    • D. F. Binns, A. H. Mufti, and N. H. Malik, "Optical Discharge Detection in SF6-insulated Systems," IEEE Trans. Electr. Insul., vol. 25, no. 2, pp. 405-414, 1990.
    • (1990) IEEE Trans. Electr. Insul. , vol.25 , Issue.2 , pp. 405-414
    • Binns, D.F.1    Mufti, A.H.2    Malik, N.H.3
  • 125
    • 84962835293 scopus 로고    scopus 로고
    • Statistical Analysis of Partial Discharges in SF6 Gas via Optical Detection in Various Spectral Ranges
    • M. Ren, M. Dong, and J. Liu, "Statistical Analysis of Partial Discharges in SF6 Gas via Optical Detection in Various Spectral Ranges," Energies, vol. 9, no. 3, p. 152 2016.
    • (2016) Energies , vol.9 , Issue.3 , pp. 152
    • Ren, M.1    Dong, M.2    Liu, J.3
  • 126
    • 84961886585 scopus 로고    scopus 로고
    • Partial discharge measurement and analysis at standard oscillating switching and lightning impulses on a GIS with artificial protrusion defects
    • M. Ren, C. Zhang, M. Dong, R. Ye, and A. Qiu, "Partial discharge measurement and analysis at standard oscillating switching and lightning impulses on a GIS with artificial protrusion defects," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 6, pp. 3459-3469, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul. , vol.22 , Issue.6 , pp. 3459-3469
    • Ren, M.1    Zhang, C.2    Dong, M.3    Ye, R.4    Qiu, A.5
  • 127
    • 38949199349 scopus 로고    scopus 로고
    • Detecting characteristics of SF6 decomposed gas sensor for insulation diagnosis on gas insulated switchgears
    • S. Okabe, S. Kaneko, T. Minagawa, and C. Nishida, "Detecting characteristics of SF6 decomposed gas sensor for insulation diagnosis on gas insulated switchgears," IEEE Trans. Dielectr. Electr. Insul., vol. 15, no. 1, pp. 251-258, 2008.
    • (2008) IEEE Trans. Dielectr. Electr. Insul. , vol.15 , Issue.1 , pp. 251-258
    • Okabe, S.1    Kaneko, S.2    Minagawa, T.3    Nishida, C.4
  • 128
    • 0022790632 scopus 로고
    • SF6 decomposition in gas-insulated equipment
    • F. Y. Chu, "SF6 Decomposition in Gas-Insulated Equipment," IEEE Trans. Electr. Insul., vol. EI-21, no. 5, pp. 693-725, 1986.
    • (1986) IEEE Trans. Electr. Insul. , vol.EI-21 , Issue.5 , pp. 693-725
    • Chu, F.Y.1
  • 129
    • 0035481219 scopus 로고    scopus 로고
    • PD signal propagation characteristics in GIS and its location system by frequency components comparison
    • H. Imagawa, et al, "PD signal propagation characteristics in GIS and its location system by frequency components comparison," IEEE Trans. Power Deliv., vol. 16, no. 4, pp. 564-570, 2001.
    • (2001) IEEE Trans. Power Deliv. , vol.16 , Issue.4 , pp. 564-570
    • Imagawa, H.1
  • 130
    • 84898432658 scopus 로고    scopus 로고
    • Utilization of artificial neural network for the estimation of size and position of metallic particle adhering to spacer in GIS
    • F. N. Budiman, Y. Khan, N. H. Malik, A. A. Al-Arainy, and A. Beroual, "Utilization of artificial neural network for the estimation of size and position of metallic particle adhering to spacer in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 20, no. 6, pp. 2143-2151, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul. , vol.20 , Issue.6 , pp. 2143-2151
    • Budiman, F.N.1    Khan, Y.2    Malik, N.H.3    Al-Arainy, A.A.4    Beroual, A.5
  • 131
    • 34147097434 scopus 로고    scopus 로고
    • Electromagnetic (EM) Wave Characteristics in GIS and Measuring the em Wave Leakage at the Spacer Aperture for Partial Discharge Diagnosis
    • M. Hikita, S. Ohtsuka, and T. Teshima, "Electromagnetic (EM) Wave Characteristics in GIS and Measuring the EM Wave Leakage at the Spacer Aperture for Partial Discharge Diagnosis," IEEE Trans. Dielectr. Electr. Insul., vol. 14, no. 2, pp. 453-460, 2007.
    • (2007) IEEE Trans. Dielectr. Electr. Insul. , vol.14 , Issue.2 , pp. 453-460
    • Hikita, M.1    Ohtsuka, S.2    Teshima, T.3
  • 133
    • 84862338139 scopus 로고    scopus 로고
    • Wavelet transform processing applied to partial discharge evaluation
    • E. C. T. Macedo, et al, "Wavelet transform processing applied to partial discharge evaluation," J. Phys. Conf. Ser., vol. 364, no. 1, 2012.
    • (2012) J. Phys. Conf. Ser. , vol.364 , Issue.1
    • Macedo, E.C.T.1
  • 134
    • 59649088078 scopus 로고    scopus 로고
    • Partial discharge diagnosis on GIS based on envelope detection
    • L. X. Li, C. J. Huang, Y. Zeng, and X. C. Jiang, "Partial discharge diagnosis on GIS based on envelope detection," WSEAS Trans. Syst., vol. 7, no. 11, pp. 1238-1247, 2008.
    • (2008) WSEAS Trans. Syst. , vol.7 , Issue.11 , pp. 1238-1247
    • Li, L.X.1    Huang, C.J.2    Zeng, Y.3    Jiang, X.C.4
  • 135
    • 85015437876 scopus 로고    scopus 로고
    • Feature extraction of GIS partial discharge signal based on S-transform and singular value decomposition
    • Mar.
    • D. Dai, X. Wang, J. Long, M. Tian, G. Zhu, and J. Zhang, "Feature extraction of GIS partial discharge signal based on S-transform and singular value decomposition," IET Sci. Measur. Technol., vol. 11, no. 2, pp. 186-193, Mar. 2017.
    • (2017) IET Sci. Measur. Technol. , vol.11 , Issue.2 , pp. 186-193
    • Dai, D.1    Wang, X.2    Long, J.3    Tian, M.4    Zhu, G.5    Zhang, J.6
  • 139
    • 84905404956 scopus 로고    scopus 로고
    • Partial discharge pattern analysis using support vector machine to estimate size and position of metallic particle adhering to spacer in GIS
    • Y. Khan, A. A. Khan, F. N. Budiman, A. Beroual, N. H. Malik, and A. A. Al-Arainy, "Partial discharge pattern analysis using support vector machine to estimate size and position of metallic particle adhering to spacer in GIS," Electr. Power Syst. Res., vol. 116, pp. 391-398, 2014.
    • (2014) Electr. Power Syst. Res. , vol.116 , pp. 391-398
    • Khan, Y.1    Khan, A.A.2    Budiman, F.N.3    Beroual, A.4    Malik, N.H.5    Al-Arainy, A.A.6
  • 141
    • 85035132644 scopus 로고    scopus 로고
    • Feature selection for partial discharge severity assessment in gas-insulated switchgear based on minimum redundancy and maximum relevance
    • Oct.
    • J. Tang, et al, "Feature Selection for Partial Discharge Severity Assessment in Gas-Insulated Switchgear Based on Minimum Redundancy and Maximum Relevance," Energies, vol. 10, no. 10, p. 1516, Oct. 2017.
    • (2017) Energies , vol.10 , Issue.10 , pp. 1516
    • Tang, J.1
  • 142
    • 84947968921 scopus 로고    scopus 로고
    • Feature parameters extraction of GIS partial discharge signal with multifractal detrended fluctuation analysis
    • J. Tang, D. Wang, L. Fan, R. Zhuo, and X. Zhang, "Feature parameters extraction of GIS partial discharge signal with multifractal detrended fluctuation analysis," IEEE Trans. Dielectr. Electr. Insul., vol. 22, no. 5, pp. 3037-3045, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul. , vol.22 , Issue.5 , pp. 3037-3045
    • Tang, J.1    Wang, D.2    Fan, L.3    Zhuo, R.4    Zhang, X.5
  • 143
    • 61349132161 scopus 로고    scopus 로고
    • Kernel statistical uncorrelated optimum discriminant vectors algorithm for GIS PD recognition
    • X. Zhang, J. Ren, J. Tang, and C. Sun, "Kernel statistical uncorrelated optimum discriminant vectors algorithm for GIS PD recognition," IEEE Trans. Dielectr. Electr. Insul., vol. 16, no. 1, pp. 206-213, 2009.
    • (2009) IEEE Trans. Dielectr. Electr. Insul. , vol.16 , Issue.1 , pp. 206-213
    • Zhang, X.1    Ren, J.2    Tang, J.3    Sun, C.4
  • 144
    • 77249107870 scopus 로고    scopus 로고
    • Partial discharge source discrimination using a support vector machine
    • L. Hao and P. L. Lewin, "Partial discharge source discrimination using a support vector machine," IEEE Trans. Dielectr. Electr. Insul., vol. 17, no. 1, pp. 189-197, 2010.
    • (2010) IEEE Trans. Dielectr. Electr. Insul. , vol.17 , Issue.1 , pp. 189-197
    • Hao, L.1    Lewin, P.L.2
  • 147
    • 84982306965 scopus 로고    scopus 로고
    • RF PD signal propagation in GIS: Comparing S-parameter measurements with an RF transmission model for a short section of GIS
    • G. Behrmann and J. Smajic, "RF PD signal propagation in GIS: Comparing S-parameter measurements with an RF transmission model for a short section of GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 23, no. 3, pp. 1331-1337, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul. , vol.23 , Issue.3 , pp. 1331-1337
    • Behrmann, G.1    Smajic, J.2
  • 148
    • 33847740251 scopus 로고    scopus 로고
    • Study on mathematical model for VHF partial discharge of typical insulated defects in GIS
    • J. Tang, Q. Zhou, M. Tang, and Y. Xie, "Study on mathematical model for VHF partial discharge of typical insulated defects in GIS," IEEE Trans. Dielectr. Electr. Insul., vol. 14, no. 1, pp. 30-37, 2007.
    • (2007) IEEE Trans. Dielectr. Electr. Insul. , vol.14 , Issue.1 , pp. 30-37
    • Tang, J.1    Zhou, Q.2    Tang, M.3    Xie, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.