메뉴 건너뛰기




Volumn 15, Issue 6, 2008, Pages 1544-1552

Partial discharge measurement in the ultra high frequency (UHF) range

Author keywords

Cable accessories; Condition assessment; Gas insulated switchgear; On site partial discharge measurement; Power transformers; UHF sensor

Indexed keywords

CABLES; DISCHARGE (FLUID MECHANICS); ELECTRIC INSTRUMENT TRANSFORMERS; ELECTRIC MACHINE INSULATION; FOURIER ANALYSIS; FOURIER TRANSFORMS; INSULATING MATERIALS; MEASUREMENTS; PARTIAL DISCHARGES; SENSORS; SIGNAL PROCESSING; SIGNAL TO NOISE RATIO; STEEL BRIDGES; TRANSFORMER SUBSTATIONS;

EID: 58149129376     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2008.4712656     Document Type: Article
Times cited : (239)

References (19)
  • 2
    • 58149126498 scopus 로고    scopus 로고
    • CIGRE TF 15/33.03.05, PD Detection System for GIS: Sensitivity Verification for the Method and the Acoustic Method, Electra No. 183, pp. 74-87, 1999.
    • CIGRE TF 15/33.03.05, "PD Detection System for GIS: Sensitivity Verification for the Method and the Acoustic Method", Electra No. 183, pp. 74-87, 1999.
  • 4
    • 58149111463 scopus 로고    scopus 로고
    • A New Procedure for Partial Discharge Localization in Gasinsulated Switchgear in Frequency Domain
    • Paper No. G-05, Beijing, China
    • S. M. Hoek, U. Riechert, T. Strehl, S. Tenbohlen and K. Feser, "A New Procedure for Partial Discharge Localization in Gasinsulated Switchgear in Frequency Domain", 14th Intern. Sympos. High Voltage Engineering, Paper No. G-05, Beijing, China, 2005.
    • (2005) 14th Intern. Sympos. High Voltage Engineering
    • Hoek, S.M.1    Riechert, U.2    Strehl, T.3    Tenbohlen, S.4    Feser, K.5
  • 5
    • 0032121519 scopus 로고    scopus 로고
    • The Application of Ultra-High-Frequency Partial Discharge Measurements to Gas-Insulated Substations
    • R. Kurrer and K. Feser, "The Application of Ultra-High-Frequency Partial Discharge Measurements to Gas-Insulated Substations", IEEE Trans. Power Delivery, Vol. 13, pp. 777-782, 1998.
    • (1998) IEEE Trans. Power Delivery , vol.13 , pp. 777-782
    • Kurrer, R.1    Feser, K.2
  • 6
    • 0038647096 scopus 로고    scopus 로고
    • Economical and technical aspects of advanced PD diagnostics to support condition based maintenance of HV assets
    • Pacific. IEEE/PES
    • J. J. Smit, E. Gulski and F. Wester, "Economical and technical aspects of advanced PD diagnostics to support condition based maintenance of HV assets", Transmission and Distribution Conference and Exhibition: Asia Pacific. IEEE/PES, Vol. 2, pp. 1110-1115, 2002.
    • (2002) Transmission and Distribution Conference and Exhibition: Asia , vol.2 , pp. 1110-1115
    • Smit, J.J.1    Gulski, E.2    Wester, F.3
  • 8
    • 0030129672 scopus 로고    scopus 로고
    • Study on detection for the defects of XLPE cable lines
    • April
    • K. Uchida et al. "Study on detection for the defects of XLPE cable lines"-IEEE Trans, on Power Delivery, Vol. 11, April 1996, pp. 663-668.
    • (1996) IEEE Trans, on Power Delivery , vol.11 , pp. 663-668
    • Uchida, K.1
  • 9
    • 58149113906 scopus 로고    scopus 로고
    • E. Lemke, H. Elze and W. Weissenberg Experience in PD diagnosis tests of HV cable terminations in service using the ultra-wide band PD probing, 13th Intern. Sympos. High Voltage Engineering, Paper No. 404, Netherlands, 2003
    • E. Lemke, H. Elze and W. Weissenberg "Experience in PD diagnosis tests of HV cable terminations in service using the ultra-wide band PD probing", 13th Intern. Sympos. High Voltage Engineering, Paper No. 404, Netherlands, 2003
  • 11
    • 58149118663 scopus 로고    scopus 로고
    • Improvement of acoustic detection and localization accuracy by sensitive electromagnetic PD measurements under oil in the UHF range
    • Paper No.G-039, Beijing, China
    • S. M. Markalous, S. Tenbohlen and K. Feser, "Improvement of acoustic detection and localization accuracy by sensitive electromagnetic PD measurements under oil in the UHF range", 14th Intern. Sympos. High Voltage Engineering, Paper No.G-039, Beijing, China, 2005.
    • (2005) 14th Intern. Sympos. High Voltage Engineering
    • Markalous, S.M.1    Tenbohlen, S.2    Feser, K.3
  • 13
    • 58149132878 scopus 로고    scopus 로고
    • Q. Chen, X. Gong, W. Gao, K. Tan and M. R. Raghuveer, Experimental study on UHF measurement for Partial Discharge in oil-impregnated insulation, 13th Intern. Sympos. High Voltage Engineering, Delft, Netherlands, ISBN 90-77017-79-8, Millpress, Rotterdam, Paper No. 159, 2003.
    • Q. Chen, X. Gong, W. Gao, K. Tan and M. R. Raghuveer, "Experimental study on UHF measurement for Partial Discharge in oil-impregnated insulation", 13th Intern. Sympos. High Voltage Engineering, Delft, Netherlands, ISBN 90-77017-79-8, Millpress, Rotterdam, Paper No. 159, 2003.
  • 17
    • 0036759963 scopus 로고    scopus 로고
    • Recognition of Discharge Sources Using UHF PD Signatures
    • R. Kuppuswamy, F. Devaux and S. Lelaidier, "Recognition of Discharge Sources Using UHF PD Signatures", IEEE Electr. Insul. Mag. Vol. 18, No. 5, pp. 8-14, 2002.
    • (2002) IEEE Electr. Insul. Mag , vol.18 , Issue.5 , pp. 8-14
    • Kuppuswamy, R.1    Devaux, F.2    Lelaidier, S.3
  • 18
    • 34147122520 scopus 로고    scopus 로고
    • Investigation into the Effects of Different Antenna Dimensions for UHF Detection of Partial Discharges in Power Transformers
    • Bologna, Italy
    • F. Marangoni, J. P. Reynders and P. J. de Klerk, "Investigation into the Effects of Different Antenna Dimensions for UHF Detection of Partial Discharges in Power Transformers", IEEE Bologna Power Tech Conference, Vol. 3, Bologna, Italy, 2003.
    • (2003) IEEE Bologna Power Tech Conference , vol.3
    • Marangoni, F.1    Reynders, J.P.2    de Klerk, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.