메뉴 건너뛰기




Volumn 18, Issue 1, 2003, Pages 4-13

Condition monitoring techniques for electrical equipment - A literature survey

Author keywords

Condition monitoring; Generator; Motor; Transformer

Indexed keywords

ARTIFICIAL INTELLIGENCE; AUTOMATION; ELECTRIC GENERATORS; ELECTRIC POWER SYSTEMS; ELECTRIC TRANSFORMERS; INDUCTION MOTORS; POWER PLANTS; SIGNAL PROCESSING;

EID: 0037252821     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2002.801425     Document Type: Review
Times cited : (334)

References (81)
  • 2
    • 0012792665 scopus 로고    scopus 로고
    • Methods of condition monitoring and fault diagnosis for induction motors
    • Sept./Oct.
    • O. V. Thorsen and M. Dalva, "Methods of condition monitoring and fault diagnosis for induction motors," ETEP, vol. 8, no. 5, Sept./Oct. 1998.
    • (1998) ETEP , vol.8 , Issue.5
    • Thorsen, O.V.1    Dalva, M.2
  • 3
    • 0030193908 scopus 로고    scopus 로고
    • Status and trends in transformer monitoring
    • July
    • C. Bengtsson, "Status and trends in transformer monitoring," IEEE Trans. Power Delivery, vol. 11, pp. 1379-1384, July 1996.
    • (1996) IEEE Trans. Power Delivery , vol.11 , pp. 1379-1384
    • Bengtsson, C.1
  • 4
    • 0032631697 scopus 로고    scopus 로고
    • Three state-of-the-art methods for condition monitoring
    • H. T. Grimmelius, P. P. Meiler, and L. M. M. Maas et al., "Three state-of-the-art methods for condition monitoring," IEEE Trans. Ind. Electron., vol. 46, pp. 407-416, 1999.
    • (1999) IEEE Trans. Ind. Electron. , vol.46 , pp. 407-416
    • Grimmelius, H.T.1    Meiler, P.P.2    Maas, L.M.M.3
  • 5
    • 0022936056 scopus 로고
    • Condition monitoring: The automated manufacturing perspective
    • Brighton, U.K., May 21-23
    • G. Prince and M. G. Shortland, "Condition monitoring: The automated manufacturing perspective," in Int. Conf. Condition Monitoring, Brighton, U.K., May 21-23, 1986.
    • (1986) Int. Conf. Condition Monitoring
    • Prince, G.1    Shortland, M.G.2
  • 7
    • 0027694514 scopus 로고
    • High reliability condition monitoring systems
    • H. W. Whittington and B. W. Flynn, "High reliability condition monitoring systems." B. J. Non-Destruct. Testing, vol. 35, no. 11, pp. 648-654, 1993.
    • (1993) B. J. Non-Destruct. Testing , vol.35 , Issue.11 , pp. 648-654
    • Whittington, H.W.1    Flynn, B.W.2
  • 8
    • 0012885131 scopus 로고    scopus 로고
    • Experiences with operating and monitoring generator transformers
    • London, U.K., Oct. 22
    • M. Checksfield and A. Westlake, "Experiences with operating and monitoring generator transformers," in Colloquium, London, U.K., Oct. 22, 1998. pp. 4/1-4/7.
    • (1998) Colloquium , pp. 41-47
    • Checksfield, M.1    Westlake, A.2
  • 9
    • 0032121723 scopus 로고    scopus 로고
    • Online monitors keep transformers in service
    • Jan.
    • T. Leibfried, "Online monitors keep transformers in service," IEEE Comput. Applicat. Power, pp. 36-42, Jan. 1996.
    • (1996) IEEE Comput. Applicat. Power , pp. 36-42
    • Leibfried, T.1
  • 12
    • 0029209481 scopus 로고
    • Partial discharge plant-monitoring technology: Present and future developments
    • Jan.
    • I. J. Kemp, "Partial discharge plant-monitoring technology: Present and future developments." in Proc. Inst. Elect. Eng. Sci. Meas. Technol., vol. 142, Jan. 1995.
    • (1995) Proc. Inst. Elect. Eng. Sci. Meas. Technol. , vol.142
    • Kemp, I.J.1
  • 13
    • 0032494993 scopus 로고    scopus 로고
    • The use of artificial neural networks for condition monitoring of electrical power transformers
    • C. Booth and J. R. McDonald, "The use of artificial neural networks for condition monitoring of electrical power transformers," Neurocomput., vol. 23, no. 1-3, pp. 97-109, 1998.
    • (1998) Neurocomput. , vol.23 , Issue.1-3 , pp. 97-109
    • Booth, C.1    McDonald, J.R.2
  • 15
    • 0032131657 scopus 로고    scopus 로고
    • A novel optical sensor for the measurement of furfuraldehyde in transformer oil
    • Aug.
    • R. Blue, D. Uttamchandani, and O. Farish, "A novel optical sensor for the measurement of furfuraldehyde in transformer oil," IEEE Trans. Instrum. Meas., vol. 47, pp. 964-966, Aug. 1998.
    • (1998) IEEE Trans. Instrum. Meas. , vol.47 , pp. 964-966
    • Blue, R.1    Uttamchandani, D.2    Farish, O.3
  • 16
    • 0032318630 scopus 로고    scopus 로고
    • The determination of FFA concentration in transformer oil by fluorescence measurements
    • _, "The determination of FFA concentration in transformer oil by fluorescence measurements," IEEE Trans. Dielect. Elect. Insul., vol. 5, no. 6, pp. 892-895, 1998.
    • (1998) IEEE Trans. Dielect. Elect. Insul. , vol.5 , Issue.6 , pp. 892-895
  • 17
    • 0032186594 scopus 로고    scopus 로고
    • A combined ANN and expert system tool for transformer fault diagnosis
    • Nov
    • Z. Y. Wang, Y. L. Liu, and P. J. Griffin. "A combined ANN and expert system tool for transformer fault diagnosis," IEEE Trans. Power Delivery, vol. 13, pp. 1224-1229, Nov, 1998.
    • (1998) IEEE Trans. Power Delivery , vol.13 , pp. 1224-1229
    • Wang, Z.Y.1    Liu, Y.L.2    Griffin, P.J.3
  • 18
    • 0030672453 scopus 로고    scopus 로고
    • Fault diagnosis of power transformers: Application of fuzzy set theory, expert systems and artificial neural networks
    • W. Xu, D. Wang, Z. Zhou, and H. Chen, "Fault diagnosis of power transformers: Application of fuzzy set theory, expert systems and artificial neural networks," in Proc. Inst. Elect. Eng. Sci. Meas. Technol., vol. 144, 1997, pp. 39-44.
    • (1997) Proc. Inst. Elect. Eng. Sci. Meas. Technol. , vol.144 , pp. 39-44
    • Xu, W.1    Wang, D.2    Zhou, Z.3    Chen, H.4
  • 19
    • 0032136423 scopus 로고    scopus 로고
    • Intelligent decision support for diagnosis of incipient transformer faults using self-organizing polynomial networks
    • Aug.
    • H. T. Yang and Y. C. Huang, "Intelligent decision support for diagnosis of incipient transformer faults using self-organizing polynomial networks," IEEE Trans. Power Syst., vol. 13, pp. 946-952, Aug. 1998.
    • (1998) IEEE Trans. Power Syst. , vol.13 , pp. 946-952
    • Yang, H.T.1    Huang, Y.C.2
  • 20
    • 0033207486 scopus 로고    scopus 로고
    • Adaptive fuzzy diagnosis system for dissolved gas analysis of power transformers
    • Oct.
    • H. T. Yang and C. C. Liao, "Adaptive fuzzy diagnosis system for dissolved gas analysis of power transformers," IEEE Trans. Power Delivery, vol. 14, pp. 1342-1350. Oct. 1999.
    • (1999) IEEE Trans. Power Delivery , vol.14 , pp. 1342-1350
    • Yang, H.T.1    Liao, C.C.2
  • 21
    • 0030263661 scopus 로고    scopus 로고
    • An artificial neural network approach to transformer fault diagnosis
    • Oct.
    • Y. Zhang, X. Ding, Y. Liu, and P. J. Griffin, "An artificial neural network approach to transformer fault diagnosis," IEEE Trans. Power Delivery, vol. 11, pp. 1836-1841, Oct. 1996.
    • (1996) IEEE Trans. Power Delivery , vol.11 , pp. 1836-1841
    • Zhang, Y.1    Ding, X.2    Liu, Y.3    Griffin, P.J.4
  • 22
    • 0031122214 scopus 로고    scopus 로고
    • Developing a new transformer fault diagnosis system through evolutionary fuzzy logic
    • Apr.
    • Y. C. Huang, H. T. Yang, and C. L. Huang, "Developing a new transformer fault diagnosis system through evolutionary fuzzy logic," IEEE Trans. Power Delivery, vol. 12, pp. 761-767, Apr. 1997.
    • (1997) IEEE Trans. Power Delivery , vol.12 , pp. 761-767
    • Huang, Y.C.1    Yang, H.T.2    Huang, C.L.3
  • 23
    • 0032627149 scopus 로고    scopus 로고
    • On-line partial discharge calibration and monitoring for power transformers
    • A. S. Farag, M. H. Shewhdi, and C. Wang et al., "On-line partial discharge calibration and monitoring for power transformers," Elect. Power Syst. Res., vol. 50, no. 1, pp. 47-54, 1999.
    • (1999) Elect. Power Syst. Res. , vol.50 , Issue.1 , pp. 47-54
    • Farag, A.S.1    Shewhdi, M.H.2    Wang, C.3
  • 24
    • 0033338601 scopus 로고    scopus 로고
    • Simulation of transformer PD pulse propagation and monitoring for a 500 kV substation
    • X. Z. Dong, D. H. Zhu, and C. C. Wang et al., "Simulation of transformer PD pulse propagation and monitoring for a 500 kV substation," IEEE Trans. Dielect. Elect. Insul., vol. 6, pp. 803-813, 1999.
    • (1999) IEEE Trans. Dielect. Elect. Insul. , vol.6 , pp. 803-813
    • Dong, X.Z.1    Zhu, D.H.2    Wang, C.C.3
  • 25
    • 0029405006 scopus 로고
    • Partial discharge 21: Acoustic emission-based PD source location in transformers
    • P. M. Eleftherion, "Partial discharge 21: Acoustic emission-based PD source location in transformers," IEEE Elect. Insul. Mag., vol. 11, no. 6, pp. 22-26, 1995.
    • (1995) IEEE Elect. Insul. Mag. , vol.11 , Issue.6 , pp. 22-26
    • Eleftherion, P.M.1
  • 26
    • 0027810749 scopus 로고
    • Detection and location of internal defects in the insulation of power transformers
    • J. Fuhr, M. Haessig, and P. Boss et al., "Detection and location of internal defects in the insulation of power transformers," IEEE Trans. Elect. Insul., vol. 28, pp. 1057-1067, 1993.
    • (1993) IEEE Trans. Elect. Insul. , vol.28 , pp. 1057-1067
    • Fuhr, J.1    Haessig, M.2    Boss, P.3
  • 27
    • 0029358585 scopus 로고
    • Correlating power transformer tank vibration characteristics to winding looseness
    • C. K. Mechefske, "Correlating power transformer tank vibration characteristics to winding looseness," in INSIGHT, vol. 37, 1995, pp. 599-604.
    • (1995) INSIGHT , vol.37 , pp. 599-604
    • Mechefske, C.K.1
  • 30
    • 0026994646 scopus 로고
    • Vertical hydraulic generators experience with dynamic air gap monitoring
    • G. B. Pollock and J. F. Lyles, "Vertical hydraulic generators experience with dynamic air gap monitoring," IEEE Trans. Energy Conversion, vol. 7, pp. 660-668, 1992.
    • (1992) IEEE Trans. Energy Conversion , vol.7 , pp. 660-668
    • Pollock, G.B.1    Lyles, J.F.2
  • 31
    • 0032634284 scopus 로고    scopus 로고
    • Failure analysis of a generator rotor with a deep crack detected during operation: Fractographic and fracture mechanics approach
    • Apr.
    • V. Bicego, E. Lucon, and C. Rinaldi et al., "Failure analysis of a generator rotor with a deep crack detected during operation: fractographic and fracture mechanics approach," Nucl. Eng. Design, vol. 188, no. 2, pp. 173-183, Apr. 1999.
    • (1999) Nucl. Eng. Design , vol.188 , Issue.2 , pp. 173-183
    • Bicego, V.1    Lucon, E.2    Rinaldi, C.3
  • 32
    • 2442759440 scopus 로고    scopus 로고
    • Flux probes provide on-line detection of generator shorted turns
    • Sept.
    • D. R. Albright, D. J. Albright, and J. D. Albright, "Flux probes provide on-line detection of generator shorted turns," Power Eng., vol. 103, no. 9, p. 28,30,32, Sept. 1999.
    • (1999) Power Eng. , vol.103 , Issue.9 , pp. 28
    • Albright, D.R.1    Albright, D.J.2    Albright, J.D.3
  • 33
    • 0012885744 scopus 로고    scopus 로고
    • Development of shorted-turn diagnosis system for generator rotor winding
    • Nov.
    • Y. J. Lee, H. D. Kim, and Y. H. Ju, "Development of shorted-turn diagnosis system for generator rotor winding," Trans. Korean Inst. Elect. Eng. C, vol. 48, no. 11, pp. 742-747, Nov. 1999.
    • (1999) Trans. Korean Inst. Elect. Eng. C , vol.48 , Issue.11 , pp. 742-747
    • Lee, Y.J.1    Kim, H.D.2    Ju, Y.H.3
  • 34
    • 0344541700 scopus 로고    scopus 로고
    • Experiences with digital analysis of discharges in high voltage components
    • May-June
    • E. Gulski, J. J. Smit, and R. Brooks et al., "Experiences with digital analysis of discharges in high voltage components," IEEE Elect. Insul. Mag., vol. 15, pp. 15-24, May-June 1999.
    • (1999) IEEE Elect. Insul. Mag. , vol.15 , pp. 15-24
    • Gulski, E.1    Smit, J.J.2    Brooks, R.3
  • 35
    • 0033351571 scopus 로고    scopus 로고
    • Continuous on-line partial discharge monitoring of generator stator windings
    • Dec.
    • B. A. Lloyd, S. R. Campbell, and G. C. Stone, "Continuous on-line partial discharge monitoring of generator stator windings," IEEE Trans. Energy Conversion, vol. 14, pp. 1131-1137, Dec. 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , pp. 1131-1137
    • Lloyd, B.A.1    Campbell, S.R.2    Stone, G.C.3
  • 36
    • 0032673008 scopus 로고    scopus 로고
    • Experience with directional couplers for partial discharge measurements on rotating machines in operation
    • June
    • W. McDermid and J. C. Bromley, "Experience with directional couplers for partial discharge measurements on rotating machines in operation," IEEE Trans. Energy Conversion, vol. 14, pp. 175-181, June 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , pp. 175-181
    • McDermid, W.1    Bromley, J.C.2
  • 37
    • 0033352692 scopus 로고    scopus 로고
    • Increased sensitivity of capacitive couplers for in-service PD measurement in rotating machines
    • Dec.
    • H. Zhu, V. Green, and M. Sasic, "Increased sensitivity of capacitive couplers for in-service PD measurement in rotating machines," IEEE Trans. Energy Conversion, vol. 14, pp. 1184-1190, Dec. 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , pp. 1184-1190
    • Zhu, H.1    Green, V.2    Sasic, M.3
  • 38
    • 0032136705 scopus 로고    scopus 로고
    • Fractal image compression for classification of PD sources
    • Aug.
    • E. M. Lalitha and L. Satish, "Fractal image compression for classification of PD sources," IEEE Trans. Dielect. Elect. Insul., vol. 5, pp. 550-557, Aug. 1998.
    • (1998) IEEE Trans. Dielect. Elect. Insul. , vol.5 , pp. 550-557
    • Lalitha, E.M.1    Satish, L.2
  • 39
    • 0031674723 scopus 로고    scopus 로고
    • Partial discharge XXV: Calibration of PD measurements for motor and generator windings-why it can't be done
    • G. C. Stone, "Partial discharge XXV: Calibration of PD measurements for motor and generator windings-why it can't be done." IEEE Elect. Insul. Mag., pp. 9-12, 1998.
    • (1998) IEEE Elect. Insul. Mag. , pp. 9-12
    • Stone, G.C.1
  • 40
    • 0032162339 scopus 로고    scopus 로고
    • Stator winding monitoring
    • Sept.-Oct.
    • G. C. Stone and J. Kapler, "Stator winding monitoring," IEEE Ind. Applicat. Mag., vol. 4, no. 5, pp. 15-20, Sept.-Oct. 1998.
    • (1998) IEEE Ind. Applicat. Mag. , vol.4 , Issue.5 , pp. 15-20
    • Stone, G.C.1    Kapler, J.2
  • 41
    • 0032310553 scopus 로고    scopus 로고
    • PD monitor system for power generators
    • Dec.
    • Z. Wang, D. Zhu, and K. Tan et al., "PD monitor system for power generators," IEEE Trans. Dielect. Elect. Insul, vol. 5, pp. 850-856, Dec. 1998.
    • (1998) IEEE Trans. Dielect. Elect. Insul , vol.5 , pp. 850-856
    • Wang, Z.1    Zhu, D.2    Tan, K.3
  • 42
    • 0030245826 scopus 로고    scopus 로고
    • New noise rejection techniques on pulse-by-pulse basis for on-line partial discharge measurement of turbine generators
    • Sept.
    • K. Itoh, Y. Kaneda, and S. Kitamura, "New noise rejection techniques on pulse-by-pulse basis for on-line partial discharge measurement of turbine generators," IEEE Trans. Energy Conversion, vol. 11, pp. 585-592, Sept. 1996.
    • (1996) IEEE Trans. Energy Conversion , vol.11 , pp. 585-592
    • Itoh, K.1    Kaneda, Y.2    Kitamura, S.3
  • 43
    • 0029755533 scopus 로고    scopus 로고
    • Toward a new partial discharge calibration strategy based on the transfer function of machine stator windings
    • Jan.
    • I. J. Kemp, H. Zhu, and H. G. Sedding et al., "Toward a new partial discharge calibration strategy based on the transfer function of machine stator windings," in Proc. Inst. Elect. Eng. Sci. Meas. Technol., vol. 143, Jan. 1996, pp. 57-62.
    • (1996) Proc. Inst. Elect. Eng. Sci. Meas. Technol. , vol.143 , pp. 57-62
    • Kemp, I.J.1    Zhu, H.2    Sedding, H.G.3
  • 44
    • 0029483605 scopus 로고
    • Rejection of narrow-band noise and repetitive pulses in on-site PD measurements
    • U. Kopf and K. Feser, "Rejection of narrow-band noise and repetitive pulses in on-site PD measurements," IEEE Trans. Dielect. Elect. Insul., vol. 2, pp. 1180-1191, 1995.
    • (1995) IEEE Trans. Dielect. Elect. Insul. , vol.2 , pp. 1180-1191
    • Kopf, U.1    Feser, K.2
  • 45
    • 0029267664 scopus 로고
    • In-service evaluation of motor and generator stator windings using partial discharge tests
    • G. C. Stone and H. G. Sedding, "In-service evaluation of motor and generator stator windings using partial discharge tests," IEEE Trans. Ind. Applicat., vol. 31, pp. 299-303, 1995.
    • (1995) IEEE Trans. Ind. Applicat. , vol.31 , pp. 299-303
    • Stone, G.C.1    Sedding, H.G.2
  • 46
  • 47
    • 0029231156 scopus 로고
    • Partial discharge pulse distribution pattern-analysis
    • T. Tanaka, "Partial discharge pulse distribution pattern-analysis," in Proc. Inst. Elect. Eng. Sci. Meas. Tech., vol. 142, 1995, pp. 46-50.
    • (1995) Proc. Inst. Elect. Eng. Sci. Meas. Tech. , vol.142 , pp. 46-50
    • Tanaka, T.1
  • 48
    • 0000056642 scopus 로고
    • Partial discharge pattern-classification using multilayer neural networks
    • L. Satish and B. I. Gururaj, "Partial discharge pattern-classification using multilayer neural networks," in Proc. Inst. Elect. Eng. A, Sci. Meas. Tech., vol. 140, 1993, pp. 323-330.
    • (1993) Proc. Inst. Elect. Eng. A, Sci. Meas. Tech. , vol.140 , pp. 323-330
    • Satish, L.1    Gururaj, B.I.2
  • 49
    • 0030106079 scopus 로고    scopus 로고
    • Application of partial discharge testing to motor and generator stator winding maintenance
    • G. C. Stone, H. G. Sedding, and M. J. Costello, "Application of partial discharge testing to motor and generator stator winding maintenance," IEEE Trans. Ind. Applicat., vol. 32, no. 2, pp. 459-464, 1996.
    • (1996) IEEE Trans. Ind. Applicat. , vol.32 , Issue.2 , pp. 459-464
    • Stone, G.C.1    Sedding, H.G.2    Costello, M.J.3
  • 50
    • 0028443845 scopus 로고
    • Practical online partial discharge tests for turbine generators and motors
    • S. R. Campbell, G. C. Stone, and H. G. Sedding et al., "Practical online partial discharge tests for turbine generators and motors," IEEE Trans. Energy Conversion, vol. 9, pp. 281-287, 1994.
    • (1994) IEEE Trans. Energy Conversion , vol.9 , pp. 281-287
    • Campbell, S.R.1    Stone, G.C.2    Sedding, H.G.3
  • 51
    • 0029356045 scopus 로고
    • A new adaptive technique for online partial discharge monitoring
    • Z. M. Sher, D. H. Zhu, and X. H. Jin et al., "A new adaptive technique for online partial discharge monitoring," IEEE Trans. Dielect. Elect. Insulation, vol. 2, pp. 700-707, 1995.
    • (1995) IEEE Trans. Dielect. Elect. Insulation , vol.2 , pp. 700-707
    • Sher, Z.M.1    Zhu, D.H.2    Jin, X.H.3
  • 52
    • 84954407951 scopus 로고    scopus 로고
    • Propagation mode and speed of partial discharge pulse through the stator windings of turbine generator
    • J. G. Jiang, D. H. Liu, and H. Deng et al., "Propagation mode and speed of partial discharge pulse through the stator windings of turbine generator," in IEEE Power Eng. Soc. 2000 Winter Meeting.
    • (2000) IEEE Power Eng. Soc. 2000 Winter Meeting
    • Jiang, J.G.1    Liu, D.H.2    Deng, H.3
  • 55
    • 0026408499 scopus 로고
    • A neural network approach to real-time condition monitoring of induction motors
    • Dec.
    • M. Y. Chow, P. M. Mangum, and S. O. Yee, "A neural network approach to real-time condition monitoring of induction motors," IEEE Trans. Ind. Electron.., vol. 38, pp. 448-453, Dec. 1991.
    • (1991) IEEE Trans. Ind. Electron.. , vol.38 , pp. 448-453
    • Chow, M.Y.1    Mangum, P.M.2    Yee, S.O.3
  • 56
    • 0031273217 scopus 로고    scopus 로고
    • Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines
    • Nov./Dec.
    • R. R. Schoen and T. G. Habetler, "Evaluation and implementation of a system to eliminate arbitrary load effects in current-based monitoring of induction machines," IEEE Trans. Ind. Applicat., vol. 33, pp. 1571-1577, Nov./Dec. 1997.
    • (1997) IEEE Trans. Ind. Applicat. , vol.33 , pp. 1571-1577
    • Schoen, R.R.1    Habetler, T.G.2
  • 57
    • 0029404270 scopus 로고
    • An unsupervised, on-line system for induction motor fault detection using stator current monitoring
    • Nov./Dec.
    • R. R. Schoen, B. K. Lin, and T. G. Habetler et al., "An unsupervised, on-line system for induction motor fault detection using stator current monitoring," IEEE Trans. Ind. Applicat., vol. 31, no. 6, pp. 1274-1279, Nov./Dec. 1995.
    • (1995) IEEE Trans. Ind. Applicat. , vol.31 , Issue.6 , pp. 1274-1279
    • Schoen, R.R.1    Lin, B.K.2    Habetler, T.G.3
  • 58
    • 0032778073 scopus 로고    scopus 로고
    • Induction motors faults detection and localization using stator current advanced signal processing techniques
    • Jan.
    • M. E. H. Benbouzid, M. Vieira, and C. Theys, "Induction motors faults detection and localization using stator current advanced signal processing techniques," IEEE Trans. Power Electron., vol. 14, pp. 14-22, Jan. 1999.
    • (1999) IEEE Trans. Power Electron. , vol.14 , pp. 14-22
    • Benbouzid, M.E.H.1    Vieira, M.2    Theys, C.3
  • 59
    • 0029404270 scopus 로고
    • Motor bearing damage detection using stator current monitoring
    • Nov./Dec.
    • R. R. Schoen, T. G. Habetler, and F. Kamran et al., "Motor bearing damage detection using stator current monitoring," IEEE Trans. Ind. Applicat., vol. 31, pp. 1280-1286, Nov./Dec. 1995.
    • (1995) IEEE Trans. Ind. Applicat. , vol.31 , pp. 1280-1286
    • Schoen, R.R.1    Habetler, T.G.2    Kamran, F.3
  • 60
    • 0031268226 scopus 로고    scopus 로고
    • Extracting useful higher order features for condition monitoring using artificial neural networks
    • Nov.
    • A. Murray and J. Penman, "Extracting useful higher order features for condition monitoring using artificial neural networks," IEEE Trans. Signal Processing, vol. 45, Nov. 1997.
    • (1997) IEEE Trans. Signal Processing , vol.45
    • Murray, A.1    Penman, J.2
  • 61
    • 0029377996 scopus 로고
    • Monitoring of defects in induction-motors through air-gap torque
    • J. S. Hsu, "Monitoring of defects in induction-motors through air-gap torque," IEEE Trans. Ind. Applicat., vol. 31, pp. 1016-1021, 1995.
    • (1995) IEEE Trans. Ind. Applicat. , vol.31 , pp. 1016-1021
    • Hsu, J.S.1
  • 62
    • 0033307990 scopus 로고    scopus 로고
    • On-line current monitoring to diagnose airgap eccentricity in large three-phase induction motors-Industrial case histories verify the predictions
    • W. T. Thomson, D. Rankin, and D. G. Dorrell, "On-line current monitoring to diagnose airgap eccentricity in large three-phase induction motors-Industrial case histories verify the predictions," IEEE Trans. Energy Conversion, vol. 14, pp. 1372-1378. 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , pp. 1372-1378
    • Thomson, W.T.1    Rankin, D.2    Dorrell, D.G.3
  • 63
    • 0029480864 scopus 로고
    • Three phase induction machines asymmetrical faults identification using bispectrum
    • Dec.
    • T. W. S. Chow and G. Fei, "Three phase induction machines asymmetrical faults identification using bispectrum," IEEE Trans. Energy Conversion, vol. 10, Dec. 1995.
    • (1995) IEEE Trans. Energy Conversion , vol.10
    • Chow, T.W.S.1    Fei, G.2
  • 64
    • 0031373959 scopus 로고    scopus 로고
    • Classification of the rotating machine condition using artificial neural networks
    • A. C. Mccormick and A. K. Nandi, "Classification of the rotating machine condition using artificial neural networks." in Proc. Inst. Mech. Eng. C Mech. Eng. Sci., vol. 211, 1997, pp. 439-449.
    • (1997) Proc. Inst. Mech. Eng. C Mech. Eng. Sci. , vol.211 , pp. 439-449
    • Mccormick, A.C.1    Nandi, A.K.2
  • 65
    • 0031652544 scopus 로고    scopus 로고
    • A study of the nature vibratory response of stator structures to improve condition monitoring strategies for induction monitors
    • M. Lucas and W. T. Thomson, "A study of the nature vibratory response of stator structures to improve condition monitoring strategies for induction monitors," in Proc. Inst. Mech. Eng. C Mech. Eng. Sci., vol. 212, 1998, pp. 57-68.
    • (1998) Proc. Inst. Mech. Eng. C Mech. Eng. Sci. , vol.212 , pp. 57-68
    • Lucas, M.1    Thomson, W.T.2
  • 67
    • 0031233479 scopus 로고    scopus 로고
    • Artificial neural network based fault diagnostics of rotating machinery using wavelet transforms as a preprocessor
    • B. A. Paya and I. I. Esat, "Artificial neural network based fault diagnostics of rotating machinery using wavelet transforms as a preprocessor," Mech. Syst. Signal Process., vol. 11, no. 5, pp. 751-765, 1997.
    • (1997) Mech. Syst. Signal Process. , vol.11 , Issue.5 , pp. 751-765
    • Paya, B.A.1    Esat, I.I.2
  • 68
    • 0032202215 scopus 로고    scopus 로고
    • A method for sensorless on-line vibration monitoring of induction machines
    • C. M. Riley, B. K. Lin, T. G. Habetler, and R. R. Schoen, "A method for sensorless on-line vibration monitoring of induction machines," IEEE Trans. Ind. Applicat., vol. 34, pp. 1240-1245, 1998.
    • (1998) IEEE Trans. Ind. Applicat. , vol.34 , pp. 1240-1245
    • Riley, C.M.1    Lin, B.K.2    Habetler, T.G.3    Schoen, R.R.4
  • 69
    • 4243256892 scopus 로고    scopus 로고
    • Stator current harmonics and their causal vibrations: A preliminary investigation of sensorless vibration monitoring applications
    • C. M. Riley, B. K. Lin, and T. G. Habetler et al., "Stator current harmonics and their causal vibrations: A preliminary investigation of sensorless vibration monitoring applications," IEEE Trans, Ind. Applicat., vol. 35, pp. 94-99, 1999.
    • (1999) IEEE Trans, Ind. Applicat. , vol.35 , pp. 94-99
    • Riley, C.M.1    Lin, B.K.2    Habetler, T.G.3
  • 70
    • 0033364048 scopus 로고    scopus 로고
    • On-line rotor cage monitoring of inverter-fed induction machines by means of an improved method
    • R. Wieser, C. Kral, and F. Pirker, "On-line rotor cage monitoring of inverter-fed induction machines by means of an improved method," IEEE Trans. Power Electron., vol. 14, pp. 858-865, 1999.
    • (1999) IEEE Trans. Power Electron. , vol.14 , pp. 858-865
    • Wieser, R.1    Kral, C.2    Pirker, F.3
  • 71
    • 0027583061 scopus 로고
    • On the application and design of artificial neural networks for motor fault detection-Part I
    • M. Y. Chow, R. N. Sharpe, and J. C. Hung, "On the application and design of artificial neural networks for motor fault detection-Part I," IEEE Trans. Ind. Electron., vol. 40, pp. 181-188, 1993.
    • (1993) IEEE Trans. Ind. Electron. , vol.40 , pp. 181-188
    • Chow, M.Y.1    Sharpe, R.N.2    Hung, J.C.3
  • 72
    • 0027584772 scopus 로고
    • On the application and design of artificial neural networks for motor fault detection-Part II
    • _, "On the application and design of artificial neural networks for motor fault detection-Part II," IEEE Trans. Ind. Electron., vol. 40, pp. 189-197, 1993.
    • (1993) IEEE Trans. Ind. Electron. , vol.40 , pp. 189-197
  • 73
    • 0033116384 scopus 로고    scopus 로고
    • Heuristic constraints enforcement for training of and knowledge extraction from a fuzzy/nueral architecture, part I: Foundation
    • M. Y. Chow, S. Altug, and H. J. Trussell. "Heuristic constraints enforcement for training of and knowledge extraction from a fuzzy/nueral architecture, part I: Foundation," IEEE Trans. Fuzzy Syst., vol. 7, pp. 143-150, 1999.
    • (1999) IEEE Trans. Fuzzy Syst. , vol.7 , pp. 143-150
    • Chow, M.Y.1    Altug, S.2    Trussell, H.J.3
  • 74
    • 0033116717 scopus 로고    scopus 로고
    • Heuristic constraints enforcement for training of and knowledge extraction from a fuzzy/nueral architecture, part II: Implementation and application
    • S. Altug, M. Y. Chow, and H. J. Trussell, "Heuristic constraints enforcement for training of and knowledge extraction from a fuzzy/nueral architecture, part II: Implementation and application," IEEE Trans. Fuzzy Syst., vol. 7, pp. 151-159, 1999.
    • (1999) IEEE Trans. Fuzzy Syst. , vol.7 , pp. 151-159
    • Altug, S.1    Chow, M.Y.2    Trussell, H.J.3
  • 75
    • 0032761528 scopus 로고    scopus 로고
    • A mutual update training algorithm for fuzzy adaptive logic control/decision network (FALCON)
    • S. Altug, H. J. Trussell, and M. Y. Chow, "A mutual update training algorithm for fuzzy adaptive logic control/decision network (FALCON)," IEEE Trans. Neural Networks, vol. 10, 1999.
    • (1999) IEEE Trans. Neural Networks , vol.10
    • Altug, S.1    Trussell, H.J.2    Chow, M.Y.3
  • 76
    • 0032662163 scopus 로고    scopus 로고
    • Induction motor asymmetrical faults detection using advanced signal processing techniques
    • June
    • M. E. H. Benbouzid and H. Nejjari, "Induction motor asymmetrical faults detection using advanced signal processing techniques," IEEE Trans. Energy Conversion, vol. 14, no. 2, pp. 147-152, June 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , Issue.2 , pp. 147-152
    • Benbouzid, M.E.H.1    Nejjari, H.2
  • 77
    • 0012835439 scopus 로고    scopus 로고
    • Application of fuzzy logic to induction motors condition monitoring
    • June
    • H. Nejjari and M. E. H. Benbouzid, "Application of fuzzy logic to induction motors condition monitoring," IEEE Power Eng. Rev., pp. 52-54, June 1999.
    • (1999) IEEE Power Eng. Rev. , pp. 52-54
    • Nejjari, H.1    Benbouzid, M.E.H.2
  • 78
    • 0033335228 scopus 로고    scopus 로고
    • Inter-turn stator winding fault diagnoisis in three-phase induction motors, by Park's vector approach
    • A. J. M. Cardoso, S. M. A. Cruz, and D. S. B. Fonseca, "Inter-turn stator winding fault diagnoisis in three-phase induction motors, by Park's vector approach," IEEE Trans. Energy Conversion, vol. 14, pp. 595-598, 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , pp. 595-598
    • Cardoso, A.J.M.1    Cruz, S.M.A.2    Fonseca, D.S.B.3
  • 79
    • 0033341512 scopus 로고    scopus 로고
    • The use of finite element methods to improve techniques for the early detection of faults in 3-phase induction motors
    • J. F. Watson, N. C. Paterson, and D. O. Dorrell, "The use of finite element methods to improve techniques for the early detection of faults in 3-phase induction motors," IEEE Trans. Energy Conversion, vol. 14. pp. 655-660, 1999.
    • (1999) IEEE Trans. Energy Conversion , vol.14 , pp. 655-660
    • Watson, J.F.1    Paterson, N.C.2    Dorrell, D.O.3
  • 80
    • 0032300084 scopus 로고    scopus 로고
    • On-line current monitoring and application of a finite element method to predict the level of static airgap eccentricity in three-phase induction motors
    • W. T. Thomson and A. Harbour, "On-line current monitoring and application of a finite element method to predict the level of static airgap eccentricity in three-phase induction motors," IEEE Trans. Energy Conversion, vol. 13, pp. 347-354, 1998.
    • (1998) IEEE Trans. Energy Conversion , vol.13 , pp. 347-354
    • Thomson, W.T.1    Harbour, A.2
  • 81
    • 0032300084 scopus 로고    scopus 로고
    • On-line current monitoring and application of a finite element method to predict the level of static airgap eccentricity in three-phase induction motors-Discussion
    • _, "On-line current monitoring and application of a finite element method to predict the level of static airgap eccentricity in three-phase induction motors-Discussion," IEEE Trans. Energy Conversion, vol. 13, pp. 355-357, 1998.
    • (1998) IEEE Trans. Energy Conversion , vol.13 , pp. 355-357


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.