메뉴 건너뛰기




Volumn 15, Issue 3, 2008, Pages 701-709

Detection of harmful metallic particles inside gas insulated switchgear using UHF sensor

Author keywords

Gas insulated switchgear; GIS; Harmful particle length; Metallic particle; Partial discharge; PD; UHF sensor

Indexed keywords

DETECTORS; ELECTRIC MACHINE INSULATION; ELECTRIC SWITCHGEAR; HEALTH; INSULATING MATERIALS; INSULATION; PALLADIUM; PARTIAL DISCHARGES; PLUTONIUM; SENSORS; TESTING;

EID: 45849152625     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2008.4543107     Document Type: Conference Paper
Times cited : (88)

References (17)
  • 1
    • 45849133071 scopus 로고    scopus 로고
    • CIGRE WG 33/23-15, Insulation Coordination of GIS: return of experience, on site tests and diagnostic Techniques, ELECTRA, No. 176, 1998.
    • CIGRE WG 33/23-15, "Insulation Coordination of GIS: return of experience, on site tests and diagnostic Techniques", ELECTRA, No. 176, 1998.
  • 3
    • 0034545398 scopus 로고    scopus 로고
    • UHF PD Detection in GIS substations during on-site testing
    • Publication
    • U. Schichler, J. Gorablenkow, and A. Diessner, "UHF PD Detection in GIS substations during on-site testing", IEE Conf. Publication, Vol. 473, pp. 139-144, 2000.
    • (2000) IEE Conf , vol.473 , pp. 139-144
    • Schichler, U.1    Gorablenkow, J.2    Diessner, A.3
  • 4
    • 34147190745 scopus 로고    scopus 로고
    • GIS Condition Assessment by Partial Discharge Analysis
    • S. Meijer, J. J. Smith, and A. Girodet, "GIS Condition Assessment by Partial Discharge Analysis", 12th ISH, Nos. 4-42, pp. 393-396, 2001.
    • (2001) 12th ISH , Issue.4-42 , pp. 393-396
    • Meijer, S.1    Smith, J.J.2    Girodet, A.3
  • 5
    • 45849107629 scopus 로고    scopus 로고
    • CIGRE TF15/33/03.05, Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method, CIGRE Electra, No. 183, pp. 75-87, 1999.
    • CIGRE TF15/33/03.05, "Partial discharge detection system for GIS: Sensitivity verification for the UHF method and the acoustic method", CIGRE Electra, No. 183, pp. 75-87, 1999.
  • 6
    • 0038576602 scopus 로고    scopus 로고
    • Development of UHF Insulation Diagnosis System of GIS
    • in Japanese
    • T. Kato, and F. Endo, "Development of UHF Insulation Diagnosis System of GIS", Trans. IEE of Japan, Vol. 119-B, No. 4, pp. 458-463, 1999. (in Japanese)
    • (1999) Trans. IEE of Japan , vol.119-B , Issue.4 , pp. 458-463
    • Kato, T.1    Endo, F.2
  • 7
    • 45849138179 scopus 로고    scopus 로고
    • Standard of International Electro-technical Commission (IEC) 60270, Ed.3.0, High-voltage test techniques - Partial discharge measurements, 2001.
    • Standard of International Electro-technical Commission (IEC) 60270, Ed.3.0, "High-voltage test techniques - Partial discharge measurements", 2001.
  • 8
    • 84945715370 scopus 로고
    • Partial Discharge -Part XIV: Acoustic Partial Discharge Detection- Practical Application
    • L. E. Lundgaard, "Partial Discharge -Part XIV: Acoustic Partial Discharge Detection- Practical Application", IEEE Electr. Insul. Mag., Vol. 8, No. 5, pp. 34-43, 1992.
    • (1992) IEEE Electr. Insul. Mag , vol.8 , Issue.5 , pp. 34-43
    • Lundgaard, L.E.1
  • 13
    • 85083921488 scopus 로고    scopus 로고
    • Investigation of High-Voltage Particle-Initiated Breakdown in Gas-Insulated Systems
    • EL-1007, 1979
    • R. E. Wootton, A. H. Cookson, and O. Farish, "Investigation of High-Voltage Particle-Initiated Breakdown in Gas-Insulated Systems", EPRI Report, EL-1007, 1979.
    • EPRI Report
    • Wootton, R.E.1    Cookson, A.H.2    Farish, O.3
  • 14
    • 45849083154 scopus 로고    scopus 로고
    • JEC-0217-1984, Metal Oxide Surge Arresters, Standard of the Japanese Electrotechnical Committee, 1984.
    • JEC-0217-1984, "Metal Oxide Surge Arresters", Standard of the Japanese Electrotechnical Committee, 1984.
  • 15
    • 33646427935 scopus 로고
    • Temporary Overvoltage and ac Test Voltage in 550kV System with Reduced Insulation Level
    • CIGRE Paper 33-203
    • T. Kawamura, S. Okabe, H. Takagi, H. Takesue, and Y. Ozaki, "Temporary Overvoltage and ac Test Voltage in 550kV System with Reduced Insulation Level", CIGRE Paper 33-203, 1990.
    • (1990)
    • Kawamura, T.1    Okabe, S.2    Takagi, H.3    Takesue, H.4    Ozaki, Y.5
  • 17
    • 45849125393 scopus 로고    scopus 로고
    • T. Kawamura, T. Suzuki, E. Zaima, I. Ohshima, T. Fujimoto, S. Kobayashi, T. Yamagiwa and K. Ibuki, Development of GIS Diagnosis and On-site Testing, CIGRE Paper, 23/33-01, 1992.A. Vetro, H. Sun, P. DaGraca, and T. Poon, Minimum drift architectures for three-layer scalable DTV decoding, IEEE Trans. Dielectr. Electr. Insul., 44, pp. 527-536, 1998.
    • T. Kawamura, T. Suzuki, E. Zaima, I. Ohshima, T. Fujimoto, S. Kobayashi, T. Yamagiwa and K. Ibuki, "Development of GIS Diagnosis and On-site Testing", CIGRE Paper, 23/33-01, 1992.A. Vetro, H. Sun, P. DaGraca, and T. Poon, "Minimum drift architectures for three-layer scalable DTV decoding", IEEE Trans. Dielectr. Electr. Insul., Vol. 44, pp. 527-536, 1998.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.