메뉴 건너뛰기




Volumn 69, Issue 18, 2017, Pages 2331-2341

Tricuspid Valve Dysfunction Following Pacemaker or Cardioverter-Defibrillator Implantation

Author keywords

echocardiography; heart failure; implantable defibrillators; regurgitation; transvenous lead extraction; tricuspid valve insufficiency

Indexed keywords

DEATH; DIAGNOSTIC IMAGING; DISEASE ASSOCIATION; DISEASE SEVERITY; DOPPLER ECHOCARDIOGRAPHY; HEART FAILURE; HEART PACING; HEMODYNAMICS; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; MITRAL ANNULOPLASTY; MORBIDITY; REVIEW; TREATMENT INDICATION; TRICUSPID VALVE REGURGITATION; ADVERSE EFFECTS; ANATOMY AND HISTOLOGY; DEVICE REMOVAL; PHYSIOLOGY; POSTOPERATIVE COMPLICATIONS; TRICUSPID VALVE; TRICUSPID VALVE INSUFFICIENCY;

EID: 85018442772     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2017.02.055     Document Type: Review
Times cited : (175)

References (118)
  • 1
    • 84867401976 scopus 로고    scopus 로고
    • Trends in permanent pacemaker implantation in the United States from 1993 to 2009: increasing complexity of patients and procedures
    • 1 Greenspon, A.J., Patel, J.D., Lau, E., et al. Trends in permanent pacemaker implantation in the United States from 1993 to 2009: increasing complexity of patients and procedures. J Am Coll Cardiol 60 (2012), 1540–1545.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1540-1545
    • Greenspon, A.J.1    Patel, J.D.2    Lau, E.3
  • 2
    • 0037035473 scopus 로고    scopus 로고
    • Cardiac pacemakers from the patient's perspective
    • 2 Wood, M.A., Ellenbogen, K.A., Cardiac pacemakers from the patient's perspective. Circulation 105 (2002), 2136–2138.
    • (2002) Circulation , vol.105 , pp. 2136-2138
    • Wood, M.A.1    Ellenbogen, K.A.2
  • 3
    • 77950232270 scopus 로고    scopus 로고
    • Predictors for short-term progressive heart failure death in New York Heart Association II patients implanted with a cardioverter defibrillator: the EVADEF study
    • 3 Marijon, E., Trinquart, L., Otmani, A., et al., EVADEF Investigators. Predictors for short-term progressive heart failure death in New York Heart Association II patients implanted with a cardioverter defibrillator: the EVADEF study. Am Heart J 159 (2010), 659–664.e1.
    • (2010) Am Heart J , vol.159 , pp. 659-664.e1
    • Marijon, E.1    Trinquart, L.2    Otmani, A.3
  • 4
    • 73449113651 scopus 로고    scopus 로고
    • Impact of implantable cardioverter-defibrillator, amiodarone, and placebo on the mode of death in stable patients with heart failure: analysis from the Sudden Cardiac Death in Heart Failure trial
    • 4 Packer, D.L., Prutkin, J.M., Hellkamp, A.S., et al. Impact of implantable cardioverter-defibrillator, amiodarone, and placebo on the mode of death in stable patients with heart failure: analysis from the Sudden Cardiac Death in Heart Failure trial. Circulation 120 (2009), 2170–2176.
    • (2009) Circulation , vol.120 , pp. 2170-2176
    • Packer, D.L.1    Prutkin, J.M.2    Hellkamp, A.S.3
  • 5
    • 33745932275 scopus 로고    scopus 로고
    • Causes and consequences of heart failure after prophylactic implantation of a defibrillator in the Multicenter Automatic Defibrillator Implantation Trial II
    • 5 Goldenberg, I., Moss, A.J., Hall, W.J., et al., Multicenter Automatic Defibrillator Implantation Trial (MADIT) II Investigators. Causes and consequences of heart failure after prophylactic implantation of a defibrillator in the Multicenter Automatic Defibrillator Implantation Trial II. Circulation 113 (2006), 2810–2817.
    • (2006) Circulation , vol.113 , pp. 2810-2817
    • Goldenberg, I.1    Moss, A.J.2    Hall, W.J.3
  • 6
    • 0842330731 scopus 로고    scopus 로고
    • Impact of tricuspid regurgitation on long-term survival
    • 6 Nath, J., Foster, E., Heidenreich, P.A., Impact of tricuspid regurgitation on long-term survival. J Am Coll Cardiol 43 (2004), 405–409.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 405-409
    • Nath, J.1    Foster, E.2    Heidenreich, P.A.3
  • 7
    • 58249113828 scopus 로고    scopus 로고
    • Functional tricuspid regurgitation in patients with pulmonary hypertension: is pulmonary artery pressure the only determinant of regurgitation severity?
    • 7 Mutlak, D., Aronson, D., Lessick, J., Reisner, S.A., Dabbah, S., Agmon, Y., Functional tricuspid regurgitation in patients with pulmonary hypertension: is pulmonary artery pressure the only determinant of regurgitation severity?. Chest 135 (2009), 115–121.
    • (2009) Chest , vol.135 , pp. 115-121
    • Mutlak, D.1    Aronson, D.2    Lessick, J.3    Reisner, S.A.4    Dabbah, S.5    Agmon, Y.6
  • 8
    • 0031764623 scopus 로고    scopus 로고
    • Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads
    • A9
    • 8 Paniagua, D., Aldrich, H.R., Lieberman, E.H., Lamas, G.A., Agatston, A.S., Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads. Am J Cardiol 82 (1998), 1130–1132 A9.
    • (1998) Am J Cardiol , vol.82 , pp. 1130-1132
    • Paniagua, D.1    Aldrich, H.R.2    Lieberman, E.H.3    Lamas, G.A.4    Agatston, A.S.5
  • 9
    • 84959345107 scopus 로고    scopus 로고
    • Tricuspid regurgitation and mortality in patients with transvenous permanent pacemaker leads
    • 9 Delling, F.N., Hassan, Z.K., Piatkowski, G., et al. Tricuspid regurgitation and mortality in patients with transvenous permanent pacemaker leads. Am J Cardiol 117 (2016), 988–992.
    • (2016) Am J Cardiol , vol.117 , pp. 988-992
    • Delling, F.N.1    Hassan, Z.K.2    Piatkowski, G.3
  • 10
    • 84901611087 scopus 로고    scopus 로고
    • Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up
    • 10 Höke, U., Auger, D., Thijssen, J., et al. Significant lead-induced tricuspid regurgitation is associated with poor prognosis at long-term follow-up. Heart 100 (2014), 960–968.
    • (2014) Heart , vol.100 , pp. 960-968
    • Höke, U.1    Auger, D.2    Thijssen, J.3
  • 12
    • 33745431521 scopus 로고    scopus 로고
    • Upgrade to biventricular pacing in patients with pacing-induced heart failure: can resynchronization do the trick?
    • 12 Dilaveris, P., Pantazis, A., Giannopoulos, G., Synetos, A., Gialafos, J., Stefanadis, C., Upgrade to biventricular pacing in patients with pacing-induced heart failure: can resynchronization do the trick?. Europace 8 (2006), 352–357.
    • (2006) Europace , vol.8 , pp. 352-357
    • Dilaveris, P.1    Pantazis, A.2    Giannopoulos, G.3    Synetos, A.4    Gialafos, J.5    Stefanadis, C.6
  • 13
    • 67449085333 scopus 로고    scopus 로고
    • The tricuspid valve: current perspective and evolving management of tricuspid regurgitation
    • 13 Rogers, J.H., Bolling, S.F., The tricuspid valve: current perspective and evolving management of tricuspid regurgitation. Circulation 119 (2009), 2718–2725.
    • (2009) Circulation , vol.119 , pp. 2718-2725
    • Rogers, J.H.1    Bolling, S.F.2
  • 14
    • 0016386893 scopus 로고
    • Perforation of the tricuspid valve by a transvenous pacemaker
    • 14 Gould, L., Reddy, C.V., Yacob, U., et al. Perforation of the tricuspid valve by a transvenous pacemaker. JAMA 230 (1974), 86–87.
    • (1974) JAMA , vol.230 , pp. 86-87
    • Gould, L.1    Reddy, C.V.2    Yacob, U.3
  • 15
    • 0025812296 scopus 로고
    • Pacemaker-lead puncture of the tricuspid valve: successful diagnosis and treatment
    • 15 Rubio, P.A., al-Bassam, M.S., Pacemaker-lead puncture of the tricuspid valve: successful diagnosis and treatment. Chest 99 (1991), 1519–1520.
    • (1991) Chest , vol.99 , pp. 1519-1520
    • Rubio, P.A.1    al-Bassam, M.S.2
  • 16
    • 18044402012 scopus 로고    scopus 로고
    • Pacing lead entanglement in the tricuspid valve apparatus during implantation
    • 16 Schilling, R.J., Pacing lead entanglement in the tricuspid valve apparatus during implantation. Europace, 1, 1999, 201.
    • (1999) Europace , vol.1 , pp. 201
    • Schilling, R.J.1
  • 17
    • 0015538150 scopus 로고
    • Tricuspid valve perforation by endocardial pacing electrode
    • 17 Petterson, S.R., Singh, J.B., Reeves, G., Kocot, S.L., Tricuspid valve perforation by endocardial pacing electrode. Chest 63 (1973), 125–126.
    • (1973) Chest , vol.63 , pp. 125-126
    • Petterson, S.R.1    Singh, J.B.2    Reeves, G.3    Kocot, S.L.4
  • 18
    • 0015350424 scopus 로고
    • Laceration of the tricuspid valve by a pacemaker wire
    • 18 Fishenfeld, J., Lamy, Y., Laceration of the tricuspid valve by a pacemaker wire. Chest 61 (1972), 697–698.
    • (1972) Chest , vol.61 , pp. 697-698
    • Fishenfeld, J.1    Lamy, Y.2
  • 19
    • 0017669572 scopus 로고
    • Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode: the role of electrode design
    • 19 Lee, M.E., Chaux, A., Matloff, J.M., Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode: the role of electrode design. J Thorac Cardiovasc Surg 74 (1977), 433–435.
    • (1977) J Thorac Cardiovasc Surg , vol.74 , pp. 433-435
    • Lee, M.E.1    Chaux, A.2    Matloff, J.M.3
  • 20
    • 0019449616 scopus 로고
    • Partial avulsion of the tricuspid valve by tined pacing electrode
    • 20 Ong, L.S., Barold, S.S., Craver, W.L., Falkoff, M.D., Heinle, R.A., Partial avulsion of the tricuspid valve by tined pacing electrode. Am Heart J 102 (1981), 798–799.
    • (1981) Am Heart J , vol.102 , pp. 798-799
    • Ong, L.S.1    Barold, S.S.2    Craver, W.L.3    Falkoff, M.D.4    Heinle, R.A.5
  • 21
    • 0032514609 scopus 로고    scopus 로고
    • Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads
    • 21 Epstein, A.E., Kay, G.N., Plumb, V.J., Dailey, S.M., Anderson, P.G., Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation 98 (1998), 1517–1524.
    • (1998) Circulation , vol.98 , pp. 1517-1524
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3    Dailey, S.M.4    Anderson, P.G.5
  • 22
    • 0022657704 scopus 로고
    • Tricuspid valve perforation by a permanent pacing lead in a patient with cardiac amyloidosis: case report and brief literature review
    • 22 Christie, J.L., Keelan, M.H. Jr., Tricuspid valve perforation by a permanent pacing lead in a patient with cardiac amyloidosis: case report and brief literature review. Pacing Clin Electrophysiol 9 (1986), 124–126.
    • (1986) Pacing Clin Electrophysiol , vol.9 , pp. 124-126
    • Christie, J.L.1    Keelan, M.H.2
  • 23
    • 0020507448 scopus 로고
    • Postmortem findings and possible causes of unexpected death in patients treated with intraventricular pacing
    • 23 Rajs, J., Postmortem findings and possible causes of unexpected death in patients treated with intraventricular pacing. Pacing Clin Electrophysiol 6 (1983), 751–760.
    • (1983) Pacing Clin Electrophysiol , vol.6 , pp. 751-760
    • Rajs, J.1
  • 24
    • 0025009856 scopus 로고
    • Entrapment of a tined pacemaker electrode in the tricuspid valve: a case report
    • 24 Frandsen, F., Oxhøj, H., Nielsen, B., Entrapment of a tined pacemaker electrode in the tricuspid valve: a case report. Pacing Clin Electrophysiol 13 (1990), 1082–1083.
    • (1990) Pacing Clin Electrophysiol , vol.13 , pp. 1082-1083
    • Frandsen, F.1    Oxhøj, H.2    Nielsen, B.3
  • 25
    • 84904002013 scopus 로고    scopus 로고
    • Perforated tricuspid valve leaflet resulting from defibrillator leads: a review of the literature
    • 25 Wilner, B.R., Coffey, J.O., Mitrani, R., Carrillo, R.G., Perforated tricuspid valve leaflet resulting from defibrillator leads: a review of the literature. J Card Surg 29 (2014), 470–472.
    • (2014) J Card Surg , vol.29 , pp. 470-472
    • Wilner, B.R.1    Coffey, J.O.2    Mitrani, R.3    Carrillo, R.G.4
  • 26
    • 84925409781 scopus 로고    scopus 로고
    • Case report: pacemaker lead perforation of a papillary muscle inducing severe tricuspid regurgitation
    • 26 Andreas, M., Gremmel, F., Habertheuer, A., et al. Case report: pacemaker lead perforation of a papillary muscle inducing severe tricuspid regurgitation. J Cardiothorac Surg, 10, 2015, 39.
    • (2015) J Cardiothorac Surg , vol.10 , pp. 39
    • Andreas, M.1    Gremmel, F.2    Habertheuer, A.3
  • 27
    • 0037305053 scopus 로고    scopus 로고
    • Tricuspid valve chordae rupture following pacemaker electrode replacement
    • 27 Moreno, R., Zamorano, J., Ortega, A., et al. Tricuspid valve chordae rupture following pacemaker electrode replacement. Int J Cardiol 87 (2003), 291–292.
    • (2003) Int J Cardiol , vol.87 , pp. 291-292
    • Moreno, R.1    Zamorano, J.2    Ortega, A.3
  • 28
    • 37549030168 scopus 로고    scopus 로고
    • Entanglement of passive fix ventricular lead in tricuspid valve
    • 28 Barclay, J.L., Cross, S.J., Leslie, S.J., Entanglement of passive fix ventricular lead in tricuspid valve. Pacing Clin Electrophysiol, 31, 2008, 138.
    • (2008) Pacing Clin Electrophysiol , vol.31 , pp. 138
    • Barclay, J.L.1    Cross, S.J.2    Leslie, S.J.3
  • 29
    • 0014548321 scopus 로고
    • Adhesions of pacing catheter to tricuspid valve: adhesive endocarditis
    • 29 Friedberg, H.D., D'Cunha, G.F., Adhesions of pacing catheter to tricuspid valve: adhesive endocarditis. Thorax 24 (1969), 498–499.
    • (1969) Thorax , vol.24 , pp. 498-499
    • Friedberg, H.D.1    D'Cunha, G.F.2
  • 32
    • 0021469157 scopus 로고
    • Entrapment of an atrial tined pacemaker electrode in the tricuspid valve: a case report
    • 32 Fürstenberg, S., Bluhm, G., Olin, C., Entrapment of an atrial tined pacemaker electrode in the tricuspid valve: a case report. Pacing Clin Electrophysiol 7 (1984), 760–762.
    • (1984) Pacing Clin Electrophysiol , vol.7 , pp. 760-762
    • Fürstenberg, S.1    Bluhm, G.2    Olin, C.3
  • 33
    • 62149107389 scopus 로고    scopus 로고
    • Permanent pacemaker implantation technique: part II
    • 33 Rajappan, K., Permanent pacemaker implantation technique: part II. Heart 95 (2009), 334–342.
    • (2009) Heart , vol.95 , pp. 334-342
    • Rajappan, K.1
  • 34
    • 84945459606 scopus 로고    scopus 로고
    • Tricuspid regurgitation following implantation of endocardial leads: incidence and predictors
    • 34 Lee, R.C., Friedman, S.E., Kono, A.T., Greenberg, M.L., Palac, R.T., Tricuspid regurgitation following implantation of endocardial leads: incidence and predictors. Pacing Clin Electrophysiol 38 (2015), 1267–1274.
    • (2015) Pacing Clin Electrophysiol , vol.38 , pp. 1267-1274
    • Lee, R.C.1    Friedman, S.E.2    Kono, A.T.3    Greenberg, M.L.4    Palac, R.T.5
  • 35
    • 0034095039 scopus 로고    scopus 로고
    • Long-term outcome of patients with multiple (> or = 3) noninfected transvenous leads: a clinical and echocardiographic study
    • 35 de Cock, C.C., Vinkers, M., Van Campe, L.C., Verhorst, P.M., Visser, C.A., Long-term outcome of patients with multiple (> or = 3) noninfected transvenous leads: a clinical and echocardiographic study. Pacing Clin Electrophysiol 23 (2000), 423–426.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 423-426
    • de Cock, C.C.1    Vinkers, M.2    Van Campe, L.C.3    Verhorst, P.M.4    Visser, C.A.5
  • 37
    • 40349087280 scopus 로고    scopus 로고
    • Impact of transvenous ventricular pacing leads on tricuspid regurgitation in pediatric and congenital heart disease patients
    • 37 Webster, G., Margossian, R., Alexander, M.E., et al. Impact of transvenous ventricular pacing leads on tricuspid regurgitation in pediatric and congenital heart disease patients. J Interv Card Electrophysiol 21 (2008), 65–68.
    • (2008) J Interv Card Electrophysiol , vol.21 , pp. 65-68
    • Webster, G.1    Margossian, R.2    Alexander, M.E.3
  • 38
    • 39749136577 scopus 로고    scopus 로고
    • The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study
    • 38 Kim, J.B., Spevack, D.M., Tunick, P.A., et al. The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study. J Am Soc Echocardiogr 21 (2008), 284–287.
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 284-287
    • Kim, J.B.1    Spevack, D.M.2    Tunick, P.A.3
  • 39
    • 84877748258 scopus 로고    scopus 로고
    • Tricuspid regurgitation in patients with pacemakers and implantable cardiac defibrillators: a comprehensive review
    • 39 Al-Bawardy, R., Krishnaswamy, A., Bhargava, M., et al. Tricuspid regurgitation in patients with pacemakers and implantable cardiac defibrillators: a comprehensive review. Clin Cardiol 36 (2013), 249–254.
    • (2013) Clin Cardiol , vol.36 , pp. 249-254
    • Al-Bawardy, R.1    Krishnaswamy, A.2    Bhargava, M.3
  • 40
    • 85018430849 scopus 로고    scopus 로고
    • Prospective study of tricuspid valve regurgitation associated with permanent leads in patients undergoing cardiac rhythm device implantation: background, rationale, and design
    • 40 Dokainish, H., Elbarasi, E., Masiero, S., et al. Prospective study of tricuspid valve regurgitation associated with permanent leads in patients undergoing cardiac rhythm device implantation: background, rationale, and design. Glob Cardiol Sci Pract, 2015, 2015, 41.
    • (2015) Glob Cardiol Sci Pract , vol.2015 , pp. 41
    • Dokainish, H.1    Elbarasi, E.2    Masiero, S.3
  • 41
    • 50549090931 scopus 로고    scopus 로고
    • Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads
    • 41 Seo, Y., Ishizu, T., Nakajima, H., Sekiguchi, Y., Watanabe, S., Aonuma, K., Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads. Circ J 72 (2008), 1465–1470.
    • (2008) Circ J , vol.72 , pp. 1465-1470
    • Seo, Y.1    Ishizu, T.2    Nakajima, H.3    Sekiguchi, Y.4    Watanabe, S.5    Aonuma, K.6
  • 42
    • 84889086582 scopus 로고    scopus 로고
    • Clinical significance of increased tricuspid valve incompetence following implantation of ventricular leads
    • 42 Baquero, G.A., Yadav, P., Skibba, J.B., et al. Clinical significance of increased tricuspid valve incompetence following implantation of ventricular leads. J Interv Card Electrophysiol 38 (2013), 197–202.
    • (2013) J Interv Card Electrophysiol , vol.38 , pp. 197-202
    • Baquero, G.A.1    Yadav, P.2    Skibba, J.B.3
  • 43
    • 0029066581 scopus 로고
    • Effect of the number of ventricular leads on right ventricular hemodynamics in patients with permanent pacemaker
    • 43 Postaci, N., Ekşi, K., Bayata, S., Yeşil, M., Effect of the number of ventricular leads on right ventricular hemodynamics in patients with permanent pacemaker. Angiology 46 (1995), 421–424.
    • (1995) Angiology , vol.46 , pp. 421-424
    • Postaci, N.1    Ekşi, K.2    Bayata, S.3    Yeşil, M.4
  • 44
    • 84857329638 scopus 로고    scopus 로고
    • Bioprosthetic tricuspid valve regurgitation associated with pacemaker or defibrillator lead implantation
    • 44 Eleid, M.F., Blauwet, L.A., Cha, Y.M., et al. Bioprosthetic tricuspid valve regurgitation associated with pacemaker or defibrillator lead implantation. J Am Coll Cardiol 59 (2012), 813–818.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 813-818
    • Eleid, M.F.1    Blauwet, L.A.2    Cha, Y.M.3
  • 45
    • 84943274426 scopus 로고    scopus 로고
    • Do transvalvular pacemaker leads influence functional outcome after tricuspid ring annuloplasty?
    • 45 Ratschiller, T., Guenther, T., Knappich, C., et al. Do transvalvular pacemaker leads influence functional outcome after tricuspid ring annuloplasty?. Eur J Cardiothorac Surg 48 (2015), 363–369.
    • (2015) Eur J Cardiothorac Surg , vol.48 , pp. 363-369
    • Ratschiller, T.1    Guenther, T.2    Knappich, C.3
  • 46
    • 0029120291 scopus 로고
    • The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leads
    • 46 Stokes, K., Anderson, J., McVenes, R., McClay, C., The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leads. Cardiovasc Pathol 4 (1995), 163–171.
    • (1995) Cardiovasc Pathol , vol.4 , pp. 163-171
    • Stokes, K.1    Anderson, J.2    McVenes, R.3    McClay, C.4
  • 47
    • 0032971951 scopus 로고    scopus 로고
    • Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads
    • 47 Candinas, R., Duru, F., Schneider, J., Lüscher, T.F., Stokes, K., Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads. Mayo Clin Proc 74 (1999), 120–125.
    • (1999) Mayo Clin Proc , vol.74 , pp. 120-125
    • Candinas, R.1    Duru, F.2    Schneider, J.3    Lüscher, T.F.4    Stokes, K.5
  • 48
    • 0026060037 scopus 로고
    • Extraction of implanted transvenous pacing leads: a review of a persistent clinical problem
    • 48 Myers, M.R., Parsonnet, V., Bernstein, A.D., Extraction of implanted transvenous pacing leads: a review of a persistent clinical problem. Am Heart J 121 (1991), 881–888.
    • (1991) Am Heart J , vol.121 , pp. 881-888
    • Myers, M.R.1    Parsonnet, V.2    Bernstein, A.D.3
  • 49
    • 33747884111 scopus 로고    scopus 로고
    • Tricuspid valve malfunction and ventricular pacemaker lead: case report and review of the literature
    • 49 Iskandar, S.B., Jackson, S.A., Fahrig, S., Mechleb, B.K., Garcia, I.D., Tricuspid valve malfunction and ventricular pacemaker lead: case report and review of the literature. Echocardiography 23 (2006), 692–697.
    • (2006) Echocardiography , vol.23 , pp. 692-697
    • Iskandar, S.B.1    Jackson, S.A.2    Fahrig, S.3    Mechleb, B.K.4    Garcia, I.D.5
  • 50
    • 33745775287 scopus 로고    scopus 로고
    • Tricuspid valve stenosis related to subvalvular adhesion of pacemaker lead: a case report
    • 50 Taira, K., Suzuki, A., Fujino, A., Watanabe, T., Ogyu, A., Ashikawa, K., Tricuspid valve stenosis related to subvalvular adhesion of pacemaker lead: a case report. J Cardiol 47 (2006), 301–306.
    • (2006) J Cardiol , vol.47 , pp. 301-306
    • Taira, K.1    Suzuki, A.2    Fujino, A.3    Watanabe, T.4    Ogyu, A.5    Ashikawa, K.6
  • 51
    • 0034022524 scopus 로고    scopus 로고
    • Pacemaker lead related tricuspid stenosis: a report of two cases
    • 51 Heaven, D.J., Henein, M.Y., Sutton, R., Pacemaker lead related tricuspid stenosis: a report of two cases. Heart 83 (2000), 351–352.
    • (2000) Heart , vol.83 , pp. 351-352
    • Heaven, D.J.1    Henein, M.Y.2    Sutton, R.3
  • 52
    • 0032977026 scopus 로고    scopus 로고
    • Predominant tricuspid stenosis secondary to bacterial endocarditis in a patient with permanent pacemaker and balloon dilatation of the stenosis
    • 52 Nisanci, Y., Yilmaz, E., Oncul, A., Ozsaruhan, O., Predominant tricuspid stenosis secondary to bacterial endocarditis in a patient with permanent pacemaker and balloon dilatation of the stenosis. Pacing Clin Electrophysiol 22 (1999), 393–396.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 393-396
    • Nisanci, Y.1    Yilmaz, E.2    Oncul, A.3    Ozsaruhan, O.4
  • 53
    • 0024557275 scopus 로고
    • Pacemaker lead-induced tricuspid stenosis: diagnosis by Doppler echocardiography
    • 53 Old, W.D., Paulsen, W., Lewis, S.A., Nixon, J.V., Pacemaker lead-induced tricuspid stenosis: diagnosis by Doppler echocardiography. Am Heart J 117 (1989), 1165–1167.
    • (1989) Am Heart J , vol.117 , pp. 1165-1167
    • Old, W.D.1    Paulsen, W.2    Lewis, S.A.3    Nixon, J.V.4
  • 54
    • 18944371653 scopus 로고    scopus 로고
    • Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads
    • 54 Lin, G., Nishimura, R.A., Connolly, H.M., Dearani, J.A., Sundt, T.M. III, Hayes, D.L., Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads. J Am Coll Cardiol 45 (2005), 1672–1675.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1672-1675
    • Lin, G.1    Nishimura, R.A.2    Connolly, H.M.3    Dearani, J.A.4    Sundt, T.M.5    Hayes, D.L.6
  • 55
    • 0018876104 scopus 로고
    • Presumptive tricuspid valve malfunction induced by a pacemaker lead: a case report and review of the literature
    • 55 Gibson, T.C., Davidson, R.C., DeSilvey, D.L., Presumptive tricuspid valve malfunction induced by a pacemaker lead: a case report and review of the literature. Pacing Clin Electrophysiol 3 (1980), 88–95.
    • (1980) Pacing Clin Electrophysiol , vol.3 , pp. 88-95
    • Gibson, T.C.1    Davidson, R.C.2    DeSilvey, D.L.3
  • 56
    • 0035574102 scopus 로고    scopus 로고
    • Permanent cardiac pacing and its influence on tricuspid valve function
    • 56 Krupa, W., Kozlowski, D., Derejko, P., Swiatecka, G., Permanent cardiac pacing and its influence on tricuspid valve function. Folia Morphol (Warsz) 60 (2001), 249–257.
    • (2001) Folia Morphol (Warsz) , vol.60 , pp. 249-257
    • Krupa, W.1    Kozlowski, D.2    Derejko, P.3    Swiatecka, G.4
  • 58
    • 23644453916 scopus 로고    scopus 로고
    • Sepsis from insidious pacemaker infection and unsuspected tricuspid valve endocarditis: the importance of transesophageal echocardiography in guiding explantation strategy
    • 58 Belikov, S., Marijic, J., Laks, H., et al. Sepsis from insidious pacemaker infection and unsuspected tricuspid valve endocarditis: the importance of transesophageal echocardiography in guiding explantation strategy. J Cardiothorac Vasc Anesth 19 (2005), 505–507.
    • (2005) J Cardiothorac Vasc Anesth , vol.19 , pp. 505-507
    • Belikov, S.1    Marijic, J.2    Laks, H.3
  • 60
    • 0025744385 scopus 로고
    • Right-sided infective endocarditis with acquired tricuspid valve stenosis associated with transvenous pacemaker: a case report
    • 60 Enia, F., Lo Mauro, R., Meschisi, F., Sabella, F.P., Right-sided infective endocarditis with acquired tricuspid valve stenosis associated with transvenous pacemaker: a case report. Pacing Clin Electrophysiol 14 (1991), 1093–1097.
    • (1991) Pacing Clin Electrophysiol , vol.14 , pp. 1093-1097
    • Enia, F.1    Lo Mauro, R.2    Meschisi, F.3    Sabella, F.P.4
  • 61
    • 0018088331 scopus 로고
    • Dynamic tricuspid valve insufficiency produced by a right ventricular thrombus from a pacemaker
    • 61 Zager, J., Berberich, S.N., Eslava, R., Klieman, C., Dynamic tricuspid valve insufficiency produced by a right ventricular thrombus from a pacemaker. Chest 74 (1978), 455–456.
    • (1978) Chest , vol.74 , pp. 455-456
    • Zager, J.1    Berberich, S.N.2    Eslava, R.3    Klieman, C.4
  • 62
    • 84860212453 scopus 로고    scopus 로고
    • Clinical characteristics and outcome of infective endocarditis involving implantable cardiac devices
    • 62 Athan, E., Chu, V.H., Tattevin, P., et al., ICE-PCS Investigators. Clinical characteristics and outcome of infective endocarditis involving implantable cardiac devices. JAMA 307 (2012), 1727–1735.
    • (2012) JAMA , vol.307 , pp. 1727-1735
    • Athan, E.1    Chu, V.H.2    Tattevin, P.3
  • 63
    • 84897058419 scopus 로고    scopus 로고
    • Tricuspid-valve repair for pacemaker leads endocarditis
    • bcr0120102673
    • 63 Iezzi, F., Cini, R., Sordini, P., Tricuspid-valve repair for pacemaker leads endocarditis. BMJ Case Rep, 2010, 2010 bcr0120102673.
    • (2010) BMJ Case Rep , vol.2010
    • Iezzi, F.1    Cini, R.2    Sordini, P.3
  • 64
    • 0032873111 scopus 로고    scopus 로고
    • Intravascular extraction of problematic or infected permanent pacemaker leads: 1994–1996. U.S. Extraction Database, MED Institute
    • 64 Byrd, C.L., Wilkoff, B.L., Love, C.J., et al. Intravascular extraction of problematic or infected permanent pacemaker leads: 1994–1996. U.S. Extraction Database, MED Institute. Pacing Clin Electrophysiol 22 (1999), 1348–1357.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 1348-1357
    • Byrd, C.L.1    Wilkoff, B.L.2    Love, C.J.3
  • 65
    • 84941317833 scopus 로고    scopus 로고
    • The effects of right ventricular apical pacing with transvenous pacemaker and implantable cardioverter defibrillator on mitral and tricuspid regurgitation
    • 65 Fanari, Z., Hammami, S., Hammami, M.B., Hammami, S., Shuraih, M., The effects of right ventricular apical pacing with transvenous pacemaker and implantable cardioverter defibrillator on mitral and tricuspid regurgitation. J Electrocardiol 48 (2015), 791–797.
    • (2015) J Electrocardiol , vol.48 , pp. 791-797
    • Fanari, Z.1    Hammami, S.2    Hammami, M.B.3    Hammami, S.4    Shuraih, M.5
  • 66
    • 80054946071 scopus 로고    scopus 로고
    • Induction and aggravation of atrioventricular valve regurgitation in the course of chronic right ventricular apical pacing
    • 66 Alizadeh, A., Sanati, H.R., Haji-Karimi, M., et al. Induction and aggravation of atrioventricular valve regurgitation in the course of chronic right ventricular apical pacing. Europace 13 (2011), 1587–1590.
    • (2011) Europace , vol.13 , pp. 1587-1590
    • Alizadeh, A.1    Sanati, H.R.2    Haji-Karimi, M.3
  • 67
    • 84952871776 scopus 로고    scopus 로고
    • Effect of right ventricular pacing on right ventricular mechanics and tricuspid regurgitation in patients with high-grade atrioventricular block and sinus rhythm (from the Protection of Left Ventricular Function During Right Ventricular Pacing Study)
    • 67 Saito, M., Iannaccone, A., Kaye, G., et al., PROTECT-PACE Investigators. Effect of right ventricular pacing on right ventricular mechanics and tricuspid regurgitation in patients with high-grade atrioventricular block and sinus rhythm (from the Protection of Left Ventricular Function During Right Ventricular Pacing Study). Am J Cardiol 116 (2015), 1875–1882.
    • (2015) Am J Cardiol , vol.116 , pp. 1875-1882
    • Saito, M.1    Iannaccone, A.2    Kaye, G.3
  • 68
    • 84928892420 scopus 로고    scopus 로고
    • Tricuspid valve regurgitation following temporary or permanent endocardial lead insertion, and the impact of cardiac resynchronization therapy
    • 68 Sadreddini, M., Haroun, M.J., Buikema, L., et al. Tricuspid valve regurgitation following temporary or permanent endocardial lead insertion, and the impact of cardiac resynchronization therapy. Open Cardiovasc Med J 8 (2014), 113–120.
    • (2014) Open Cardiovasc Med J , vol.8 , pp. 113-120
    • Sadreddini, M.1    Haroun, M.J.2    Buikema, L.3
  • 69
    • 77955882203 scopus 로고    scopus 로고
    • Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode
    • 69 Vaturi, M., Kusniec, J., Shapira, Y., et al. Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode. Eur J Echocardiogr 11 (2010), 550–553.
    • (2010) Eur J Echocardiogr , vol.11 , pp. 550-553
    • Vaturi, M.1    Kusniec, J.2    Shapira, Y.3
  • 71
    • 84898822424 scopus 로고    scopus 로고
    • 3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation
    • 71 Mediratta, A., Addetia, K., Yamat, M., et al. 3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation. J Am Coll Cardiol Img 7 (2014), 337–347.
    • (2014) J Am Coll Cardiol Img , vol.7 , pp. 337-347
    • Mediratta, A.1    Addetia, K.2    Yamat, M.3
  • 72
    • 34250752270 scopus 로고    scopus 로고
    • Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: role of real time three-dimensional echocardiography
    • 72 Nucifora, G., Badano, L.P., Allocca, G., et al. Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: role of real time three-dimensional echocardiography. Echocardiography 24 (2007), 649–652.
    • (2007) Echocardiography , vol.24 , pp. 649-652
    • Nucifora, G.1    Badano, L.P.2    Allocca, G.3
  • 73
    • 84874086956 scopus 로고    scopus 로고
    • Three-dimensional transthoracic echocardiography in the diagnosis of device lead-related tricuspid leaflet entrapment
    • 73 Narayan, R.L., Vaishnava, P., Goldman, M., Three-dimensional transthoracic echocardiography in the diagnosis of device lead-related tricuspid leaflet entrapment. Tex Heart Inst J 39 (2012), 906–907.
    • (2012) Tex Heart Inst J , vol.39 , pp. 906-907
    • Narayan, R.L.1    Vaishnava, P.2    Goldman, M.3
  • 74
    • 34347249115 scopus 로고    scopus 로고
    • Entrapment of permanent pacemaker lead as the cause of tricuspid regurgitation
    • 74 Chen, T.E., Wang, C.C., Chern, M.S., Chu, J.J., Entrapment of permanent pacemaker lead as the cause of tricuspid regurgitation. Circ J 71 (2007), 1169–1171.
    • (2007) Circ J , vol.71 , pp. 1169-1171
    • Chen, T.E.1    Wang, C.C.2    Chern, M.S.3    Chu, J.J.4
  • 75
    • 84879779889 scopus 로고    scopus 로고
    • A new view of an unusual pacemaker complication: role of three-dimensional transthoracic echocardiography
    • 75 Miglioranza, M.H., Becker, D., Jiménez-Nácher, J.J., Moya, J.L., Golfin, C.F., Zamorano, J.L., A new view of an unusual pacemaker complication: role of three-dimensional transthoracic echocardiography. Echocardiography 30 (2013), E164–E166.
    • (2013) Echocardiography , vol.30 , pp. E164-E166
    • Miglioranza, M.H.1    Becker, D.2    Jiménez-Nácher, J.J.3    Moya, J.L.4    Golfin, C.F.5    Zamorano, J.L.6
  • 76
    • 84982276892 scopus 로고    scopus 로고
    • Clinical utility of three-dimensional echocardiography in the evaluation of tricuspid regurgitation induced by implantable device leads
    • 76 Cheng, Y., Gao, H., Tang, L., Li, J., Yao, L., Clinical utility of three-dimensional echocardiography in the evaluation of tricuspid regurgitation induced by implantable device leads. Echocardiography 33 (2016), 1689–1696.
    • (2016) Echocardiography , vol.33 , pp. 1689-1696
    • Cheng, Y.1    Gao, H.2    Tang, L.3    Li, J.4    Yao, L.5
  • 77
    • 84914103095 scopus 로고    scopus 로고
    • Impact of implantable transvenous device lead location on severity of tricuspid regurgitation
    • 77 Addetia, K., Maffessanti, F., Mediratta, A., et al. Impact of implantable transvenous device lead location on severity of tricuspid regurgitation. J Am Soc Echocardiogr 27 (2014), 1164–1175.
    • (2014) J Am Soc Echocardiogr , vol.27 , pp. 1164-1175
    • Addetia, K.1    Maffessanti, F.2    Mediratta, A.3
  • 78
    • 0036319244 scopus 로고    scopus 로고
    • Permanent pacemaker lead entrapment: role of the transesophageal echocardiography
    • 78 Champagne, J., Poirier, P., Dumesnil, J.G., et al. Permanent pacemaker lead entrapment: role of the transesophageal echocardiography. Pacing Clin Electrophysiol 25 (2002), 1131–1134.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1131-1134
    • Champagne, J.1    Poirier, P.2    Dumesnil, J.G.3
  • 79
    • 84893154861 scopus 로고    scopus 로고
    • Massive tricuspid regurgitation due to pacemaker-lead puncture of the tricuspid valve: successful diagnosis by 3-dimensional echocardiography
    • 79 Tamai, R., Hara, T., Yamada, H., et al. Massive tricuspid regurgitation due to pacemaker-lead puncture of the tricuspid valve: successful diagnosis by 3-dimensional echocardiography. J Med Ultrason (2001) 41 (2014), 69–71.
    • (2014) J Med Ultrason (2001) , vol.41 , pp. 69-71
    • Tamai, R.1    Hara, T.2    Yamada, H.3
  • 80
    • 84927942197 scopus 로고    scopus 로고
    • Tricuspid regurgitation severity associated with positioning of RV lead or other etiology assessed by intracardiac echocardiography
    • 80 Ren, J.F., Callans, D.J., Marchlinski, F.E., Tricuspid regurgitation severity associated with positioning of RV lead or other etiology assessed by intracardiac echocardiography. J Am Coll Cardiol Img 7 (2014), 1285–1286.
    • (2014) J Am Coll Cardiol Img , vol.7 , pp. 1285-1286
    • Ren, J.F.1    Callans, D.J.2    Marchlinski, F.E.3
  • 81
    • 77950508753 scopus 로고    scopus 로고
    • Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights
    • 81 Voigt, A., Shalaby, A., Saba, S., Continued rise in rates of cardiovascular implantable electronic device infections in the United States: temporal trends and causative insights. Pacing Clin Electrophysiol 33 (2010), 414–419.
    • (2010) Pacing Clin Electrophysiol , vol.33 , pp. 414-419
    • Voigt, A.1    Shalaby, A.2    Saba, S.3
  • 82
    • 84924175097 scopus 로고    scopus 로고
    • Virtual reality lead extraction as a method for training new physicians: a pilot study
    • 82 Maytin, M., Daily, T.P., Carillo, R.G., Virtual reality lead extraction as a method for training new physicians: a pilot study. Pacing Clin Electrophysiol 38 (2015), 319–325.
    • (2015) Pacing Clin Electrophysiol , vol.38 , pp. 319-325
    • Maytin, M.1    Daily, T.P.2    Carillo, R.G.3
  • 83
    • 84911993568 scopus 로고    scopus 로고
    • Safety of transvenous lead extraction according to centre volume: a systematic review and meta-analysis
    • 83 Di Monaco, A., Pelargonio, G., Narducci, M.L., et al. Safety of transvenous lead extraction according to centre volume: a systematic review and meta-analysis. Europace 16 (2014), 1496–1507.
    • (2014) Europace , vol.16 , pp. 1496-1507
    • Di Monaco, A.1    Pelargonio, G.2    Narducci, M.L.3
  • 84
    • 84956873711 scopus 로고    scopus 로고
    • Tricuspid regurgitation following lead extraction: risk factors and clinical course
    • 84 Givon, A., Vedernikova, N., Luria, D., et al. Tricuspid regurgitation following lead extraction: risk factors and clinical course. Isr Med Assoc J 18 (2016), 18–22.
    • (2016) Isr Med Assoc J , vol.18 , pp. 18-22
    • Givon, A.1    Vedernikova, N.2    Luria, D.3
  • 85
    • 79959977624 scopus 로고    scopus 로고
    • Tricuspid valve repair for torrential tricuspid regurgitation after permanent pacemaker lead extraction
    • 85 Mehrotra, D., Kejriwal, N.K., Tricuspid valve repair for torrential tricuspid regurgitation after permanent pacemaker lead extraction. Tex Heart Inst J 38 (2011), 305–307.
    • (2011) Tex Heart Inst J , vol.38 , pp. 305-307
    • Mehrotra, D.1    Kejriwal, N.K.2
  • 86
    • 66149153869 scopus 로고    scopus 로고
    • Incidence, risk factors, and outcome of traumatic tricuspid regurgitation after percutaneous ventricular lead removal
    • 86 Franceschi, F., Thuny, F., Giorgi, R., et al. Incidence, risk factors, and outcome of traumatic tricuspid regurgitation after percutaneous ventricular lead removal. J Am Coll Cardiol 53 (2009), 2168–2174.
    • (2009) J Am Coll Cardiol , vol.53 , pp. 2168-2174
    • Franceschi, F.1    Thuny, F.2    Giorgi, R.3
  • 87
    • 0033008662 scopus 로고    scopus 로고
    • Partial rupture of the tricuspid valve after extraction of permanent pacemaker leads: detection by transesophageal echocardiography
    • 87 Assayag, P., Thuaire, C., Benamer, H., Sebbah, J., Leport, C., Brochet, E., Partial rupture of the tricuspid valve after extraction of permanent pacemaker leads: detection by transesophageal echocardiography. Pacing Clin Electrophysiol 22 (1999), 971–974.
    • (1999) Pacing Clin Electrophysiol , vol.22 , pp. 971-974
    • Assayag, P.1    Thuaire, C.2    Benamer, H.3    Sebbah, J.4    Leport, C.5    Brochet, E.6
  • 90
    • 0033133418 scopus 로고    scopus 로고
    • Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial
    • 90 Wilkoff, B.L., Byrd, C.L., Love, C.J., et al. Pacemaker lead extraction with the laser sheath: results of the pacing lead extraction with the excimer sheath (PLEXES) trial. J Am Coll Cardiol 33 (1999), 1671–1676.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 1671-1676
    • Wilkoff, B.L.1    Byrd, C.L.2    Love, C.J.3
  • 91
    • 0036854491 scopus 로고    scopus 로고
    • Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction
    • 91 Roeffel, S., Bracke, F., Meijer, A., et al. Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction. Pacing Clin Electrophysiol 25 (2002), 1583–1586.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1583-1586
    • Roeffel, S.1    Bracke, F.2    Meijer, A.3
  • 92
    • 84975473602 scopus 로고    scopus 로고
    • Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads
    • 92 Uehara, K., Minakata, K., Watanabe, K., et al. Tricuspid valve repair for severe tricuspid regurgitation due to pacemaker leads. Asian Cardiovasc Thorac Ann 24 (2016), 541–545.
    • (2016) Asian Cardiovasc Thorac Ann , vol.24 , pp. 541-545
    • Uehara, K.1    Minakata, K.2    Watanabe, K.3
  • 93
    • 84984982127 scopus 로고    scopus 로고
    • Tricuspid valve replacement preserving endocardial pacemaker lead
    • 93 Yoshikai, M., Miho, T., Satoh, H., Nakanishi, H., Tricuspid valve replacement preserving endocardial pacemaker lead. J Card Surg 31 (2016), 311–314.
    • (2016) J Card Surg , vol.31 , pp. 311-314
    • Yoshikai, M.1    Miho, T.2    Satoh, H.3    Nakanishi, H.4
  • 94
    • 84961262638 scopus 로고    scopus 로고
    • Complex tricuspid valve repair in patients with pacer defibrillator-related tricuspid regurgitation
    • 94 Raman, J., Sugeng, L., Lai, D.T., Jeevanandam, V., Complex tricuspid valve repair in patients with pacer defibrillator-related tricuspid regurgitation. Ann Thorac Surg 101 (2016), 1599–1601.
    • (2016) Ann Thorac Surg , vol.101 , pp. 1599-1601
    • Raman, J.1    Sugeng, L.2    Lai, D.T.3    Jeevanandam, V.4
  • 95
    • 79954601666 scopus 로고    scopus 로고
    • Tricuspid valve repair in the presence of a permanent ventricular pacemaker lead
    • 95 Pfannmueller, B., Hirnle, G., Seeburger, J., et al. Tricuspid valve repair in the presence of a permanent ventricular pacemaker lead. Eur J Cardiothorac Surg 39 (2011), 657–661.
    • (2011) Eur J Cardiothorac Surg , vol.39 , pp. 657-661
    • Pfannmueller, B.1    Hirnle, G.2    Seeburger, J.3
  • 96
    • 76449112615 scopus 로고    scopus 로고
    • Long-term follow-up of permanent transvenous pacing systems preserved during tricuspid valve replacement
    • 96 Molina, J.E., Roberts, C.L., Benditt, D.G., Long-term follow-up of permanent transvenous pacing systems preserved during tricuspid valve replacement. Ann Thorac Surg 89 (2010), 318–320.
    • (2010) Ann Thorac Surg , vol.89 , pp. 318-320
    • Molina, J.E.1    Roberts, C.L.2    Benditt, D.G.3
  • 97
    • 84912028446 scopus 로고    scopus 로고
    • Transvenous valve-in-valve replacement preserving the function of a transvalvular defibrillator lead
    • 97 De Meester, P., Budts, W., Gewillig, M., Transvenous valve-in-valve replacement preserving the function of a transvalvular defibrillator lead. Catheter Cardiovasc Interv 84 (2014), 1148–1152.
    • (2014) Catheter Cardiovasc Interv , vol.84 , pp. 1148-1152
    • De Meester, P.1    Budts, W.2    Gewillig, M.3
  • 98
    • 84928957897 scopus 로고    scopus 로고
    • Transcatheter tricuspid valve-in-valve in patients with transvalvular device leads
    • 98 Eleid, M.F., Asirvatham, S.J., Cabalka, A.K., et al. Transcatheter tricuspid valve-in-valve in patients with transvalvular device leads. Catheter Cardiovasc Interv 87 (2016), E160–E165.
    • (2016) Catheter Cardiovasc Interv , vol.87 , pp. E160-E165
    • Eleid, M.F.1    Asirvatham, S.J.2    Cabalka, A.K.3
  • 99
    • 84929842532 scopus 로고    scopus 로고
    • Jailing of a pacemaker lead during tricuspid valve-in-valve implantation with an Edwards SAPIEN XT transcatheter heart valve
    • 819.e9–11
    • 99 Paradis, J.M., Bernier, M., Houde, C., et al. Jailing of a pacemaker lead during tricuspid valve-in-valve implantation with an Edwards SAPIEN XT transcatheter heart valve. Can J Cardiol, 31, 2015 819.e9–11.
    • (2015) Can J Cardiol , vol.31
    • Paradis, J.M.1    Bernier, M.2    Houde, C.3
  • 100
    • 84874439734 scopus 로고    scopus 로고
    • Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation
    • 100 Nazmul, M.N., Cha, Y.M., Lin, G., Asirvatham, S.J., Powell, B.D., Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation. Europace 15 (2013), 409–413.
    • (2013) Europace , vol.15 , pp. 409-413
    • Nazmul, M.N.1    Cha, Y.M.2    Lin, G.3    Asirvatham, S.J.4    Powell, B.D.5
  • 101
    • 84963567981 scopus 로고    scopus 로고
    • Left ventricular pacing through coronary sinus is feasible and safe for patients with prior tricuspid valve intervention
    • 101 Sideris, S., Drakopoulou, M., Oikonomopoulos, G., et al. Left ventricular pacing through coronary sinus is feasible and safe for patients with prior tricuspid valve intervention. Pacing Clin Electrophysiol 39 (2016), 378–381.
    • (2016) Pacing Clin Electrophysiol , vol.39 , pp. 378-381
    • Sideris, S.1    Drakopoulou, M.2    Oikonomopoulos, G.3
  • 102
    • 67650733301 scopus 로고    scopus 로고
    • The coronary sinus: a versatile option for pacemaker implantation during minimally invasive valve surgery
    • 102 Seeburger, J., Merk, D.R., Holzhey, D., Borger, M.A., Doll, N., Mohr, F.W., The coronary sinus: a versatile option for pacemaker implantation during minimally invasive valve surgery. J Card Surg 24 (2009), 431–432.
    • (2009) J Card Surg , vol.24 , pp. 431-432
    • Seeburger, J.1    Merk, D.R.2    Holzhey, D.3    Borger, M.A.4    Doll, N.5    Mohr, F.W.6
  • 103
    • 41049098795 scopus 로고    scopus 로고
    • First case report in Japan of left ventricular pacing via a coronary vein in a patient with a mechanical tricuspid valve
    • 103 Yoda, M., Nakai, T., Okubo, K., et al. First case report in Japan of left ventricular pacing via a coronary vein in a patient with a mechanical tricuspid valve. Circ J 72 (2008), 335–336.
    • (2008) Circ J , vol.72 , pp. 335-336
    • Yoda, M.1    Nakai, T.2    Okubo, K.3
  • 104
    • 67549100824 scopus 로고    scopus 로고
    • Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA)
    • 104 Wilkoff, B.L., Love, C.J., Byrd, C.L., et al. Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA). Heart Rhythm 6 (2009), 1085–1104.
    • (2009) Heart Rhythm , vol.6 , pp. 1085-1104
    • Wilkoff, B.L.1    Love, C.J.2    Byrd, C.L.3
  • 105
    • 78049445163 scopus 로고    scopus 로고
    • Epicardial versus endocardial permanent pacing in adults with congenital heart disease
    • 105 McLeod, C.J., Attenhofer Jost, C.H., Warnes, C.A., et al. Epicardial versus endocardial permanent pacing in adults with congenital heart disease. J Interv Card Electrophysiol 28 (2010), 235–243.
    • (2010) J Interv Card Electrophysiol , vol.28 , pp. 235-243
    • McLeod, C.J.1    Attenhofer Jost, C.H.2    Warnes, C.A.3
  • 106
    • 84924052948 scopus 로고    scopus 로고
    • Long-term atrial and ventricular epicardial pacemaker lead survival after cardiac operations in pediatric patients with congenital heart disease
    • 106 Lau, K.C., Gaynor, J.W., Fuller, S.M., Smoots, K.A., Shah, M.J., Long-term atrial and ventricular epicardial pacemaker lead survival after cardiac operations in pediatric patients with congenital heart disease. Heart Rhythm 12 (2015), 566–573.
    • (2015) Heart Rhythm , vol.12 , pp. 566-573
    • Lau, K.C.1    Gaynor, J.W.2    Fuller, S.M.3    Smoots, K.A.4    Shah, M.J.5
  • 107
    • 0014067394 scopus 로고
    • A technique for ventricular pacing from the His bundle of the intact heart
    • 107 Scherlag, B.J., Kosowsky, B.D., Damato, A.N., A technique for ventricular pacing from the His bundle of the intact heart. J Appl Physiol 22 (1967), 584–587.
    • (1967) J Appl Physiol , vol.22 , pp. 584-587
    • Scherlag, B.J.1    Kosowsky, B.D.2    Damato, A.N.3
  • 108
    • 0033999383 scopus 로고    scopus 로고
    • Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation
    • 108 Deshmukh, P., Casavant, D.A., Romanyshyn, M., Anderson, K., Permanent, direct His-bundle pacing: a novel approach to cardiac pacing in patients with normal His-Purkinje activation. Circulation 101 (2000), 869–877.
    • (2000) Circulation , vol.101 , pp. 869-877
    • Deshmukh, P.1    Casavant, D.A.2    Romanyshyn, M.3    Anderson, K.4
  • 111
    • 84905643973 scopus 로고    scopus 로고
    • His or para-His pacing preserves left ventricular function in atrioventricular block: a double-blind, randomized, crossover study
    • 111 Kronborg, M.B., Mortensen, P.T., Poulsen, S.H., Gerdes, J.C., Jensen, H.K., Nielsen, J.C., His or para-His pacing preserves left ventricular function in atrioventricular block: a double-blind, randomized, crossover study. Europace 16 (2014), 1189–1196.
    • (2014) Europace , vol.16 , pp. 1189-1196
    • Kronborg, M.B.1    Mortensen, P.T.2    Poulsen, S.H.3    Gerdes, J.C.4    Jensen, H.K.5    Nielsen, J.C.6
  • 112
    • 79952473265 scopus 로고    scopus 로고
    • Safety and performance of a system specifically designed for selective site pacing
    • 112 Zanon, F., Svetlich, C., Occhetta, E., et al. Safety and performance of a system specifically designed for selective site pacing. Pacing Clin Electrophysiol 34 (2011), 339–347.
    • (2011) Pacing Clin Electrophysiol , vol.34 , pp. 339-347
    • Zanon, F.1    Svetlich, C.2    Occhetta, E.3
  • 113
    • 84921046590 scopus 로고    scopus 로고
    • Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice
    • 113 Sharma, P.S., Dandamudi, G., Naperkowski, A., et al. Permanent His-bundle pacing is feasible, safe, and superior to right ventricular pacing in routine clinical practice. Heart Rhythm 12 (2015), 305–312.
    • (2015) Heart Rhythm , vol.12 , pp. 305-312
    • Sharma, P.S.1    Dandamudi, G.2    Naperkowski, A.3
  • 114
    • 84929049566 scopus 로고    scopus 로고
    • Acute His-bundle injury current during permanent His-bundle pacing predicts excellent pacing outcomes
    • 114 Vijayaraman, P., Dandamudi, G., Worsnick, S., Ellenbogen, K.A., Acute His-bundle injury current during permanent His-bundle pacing predicts excellent pacing outcomes. Pacing Clin Electrophysiol 38 (2015), 540–546.
    • (2015) Pacing Clin Electrophysiol , vol.38 , pp. 540-546
    • Vijayaraman, P.1    Dandamudi, G.2    Worsnick, S.3    Ellenbogen, K.A.4
  • 115
    • 84992641069 scopus 로고    scopus 로고
    • Synchronous ventricular pacing with direct capture of the atrioventricular conduction system: functional anatomy, terminology, and challenges
    • 115 Mulpuru, S.K., Cha, Y.M., Asirvatham, S.J., Synchronous ventricular pacing with direct capture of the atrioventricular conduction system: functional anatomy, terminology, and challenges. Heart Rhythm 13 (2016), 2237–2246.
    • (2016) Heart Rhythm , vol.13 , pp. 2237-2246
    • Mulpuru, S.K.1    Cha, Y.M.2    Asirvatham, S.J.3
  • 116
    • 84942021935 scopus 로고    scopus 로고
    • Percutaneous implantation of an entirely intracardiac leadless pacemaker
    • 116 Reddy, V.Y., Exner, D.V., Cantillon, D.J., et al., LEADLESS II Study Investigators. Percutaneous implantation of an entirely intracardiac leadless pacemaker. N Engl J Med 373 (2015), 1125–1135.
    • (2015) N Engl J Med , vol.373 , pp. 1125-1135
    • Reddy, V.Y.1    Exner, D.V.2    Cantillon, D.J.3
  • 117
    • 84976510715 scopus 로고    scopus 로고
    • A leadless intracardiac transcatheter pacing system
    • 117 Reynolds, D.W., Ritter, P., A leadless intracardiac transcatheter pacing system. N Engl J Med 374 (2016), 2604–2605.
    • (2016) N Engl J Med , vol.374 , pp. 2604-2605
    • Reynolds, D.W.1    Ritter, P.2
  • 118
    • 84900324755 scopus 로고    scopus 로고
    • Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark
    • 118 Kirkfeldt, R.E., Johansen, J.B., Nohr, E.A., Jørgensen, O.D., Nielsen, J.C., Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. Eur Heart J 35 (2014), 1186–1194.
    • (2014) Eur Heart J , vol.35 , pp. 1186-1194
    • Kirkfeldt, R.E.1    Johansen, J.B.2    Nohr, E.A.3    Jørgensen, O.D.4    Nielsen, J.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.