메뉴 건너뛰기




Volumn 25, Issue 11, 2002, Pages 1583-1586

Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction

Author keywords

Implantable defibrillator; Laser; Lead extraction; Pacemaker; Tricuspid valve

Indexed keywords

LEAD;

EID: 0036854491     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1460-9592.2002.01583.x     Document Type: Article
Times cited : (42)

References (16)
  • 1
    • 0015380386 scopus 로고
    • Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode
    • Becker AE, Becker MJ, Claudon DG, et al. Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode. Circulation 1972; 46;409-412.
    • (1972) Circulation , vol.46 , pp. 409-412
    • Becker, A.E.1    Becker, M.J.2    Claudon, D.G.3
  • 2
    • 0032971951 scopus 로고    scopus 로고
    • Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads
    • Candinas R, Duru F, Schneider J, et al. Postmortem analysis of encapsulation around long-term ventricular endocardial pacing leads. Mayo Clin Proc 1999; 74:120-125.
    • (1999) Mayo Clin Proc , vol.74 , pp. 120-125
    • Candinas, R.1    Duru, F.2    Schneider, J.3
  • 3
    • 0001012722 scopus 로고
    • Cardiovascular tissue response to intracardiac pacemaking
    • Lagergren H, Dahlgren S, Norderstam H. Cardiovascular tissue response to intracardiac pacemaking. Acta Chir Scand 1966; 132:696-704.
    • (1966) Acta Chir Scand , vol.132 , pp. 696-704
    • Lagergren, H.1    Dahlgren, S.2    Norderstam, H.3
  • 4
    • 0014497212 scopus 로고
    • Autopsy findings with permanent pervenous pacemakers
    • Robboy SJ, Harthorne JW, Leinbach RC, et al. Autopsy findings with permanent pervenous pacemakers. Circulation 1969; 39:495-501.
    • (1969) Circulation , vol.39 , pp. 495-501
    • Robboy, S.J.1    Harthorne, J.W.2    Leinbach, R.C.3
  • 5
    • 0026513673 scopus 로고
    • Venous complications after insertion of a transvenous pacemaker
    • Spittell PC, Hayes DL. Venous complications after insertion of a transvenous pacemaker. Mayo Clin Proc 1992; 67:258-265.
    • (1992) Mayo Clin Proc , vol.67 , pp. 258-265
    • Spittell, P.C.1    Hayes, D.L.2
  • 6
    • 0032514609 scopus 로고    scopus 로고
    • Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads
    • Epstein AE, Kay GN, Plumb VJ, et al. Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation 1998; 98:1517-1524.
    • (1998) Circulation , vol.98 , pp. 1517-1524
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3
  • 7
    • 0025009856 scopus 로고
    • Entrapment of a tined pacemaker electrode in the tricuspid valve. A case report
    • Frandsen F, Oxhoj H, Nielsen B. Entrapment of a tined pacemaker electrode in the tricuspid valve. A case report. PACE 1990; 13:1082-1083.
    • (1990) PACE , vol.13 , pp. 1082-1083
    • Frandsen, F.1    Oxhoj, H.2    Nielsen, B.3
  • 8
    • 0032782314 scopus 로고    scopus 로고
    • Single center experience with femoral extraction of permanent endocardial pacing leads
    • Jarwe M, Klug D, Beregi JP, et al. Single center experience with femoral extraction of permanent endocardial pacing leads. PACE 1999; 22:1202-1209.
    • (1999) PACE , vol.22 , pp. 1202-1209
    • Jarwe, M.1    Klug, D.2    Beregi, J.P.3
  • 9
    • 0017669572 scopus 로고
    • Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode. The role of electrode design
    • Lee ME, Chau, x A, Matloff JM. Avulsion of a tricuspid valve leaflet during traction on an infected, entrapped endocardial pacemaker electrode. The role of electrode design. J Thorac Cardiovasc Surg 1977; 74:433-435.
    • (1977) J Thorac Cardiovasc Surg , vol.74 , pp. 433-435
    • Lee, M.E.1    Chaux, A.2    Matloff, J.M.3
  • 10
    • 0032534063 scopus 로고    scopus 로고
    • Initial experience with a laser sheath to extract chronic transvenous implantable cardioverter-defibrillator leads
    • Krishnan SC, Epstein LM. Initial experience with a laser sheath to extract chronic transvenous implantable cardioverter-defibrillator leads. Am J Cardiol 1998; 82:1293-1295.
    • (1998) Am J Cardiol , vol.82 , pp. 1293-1295
    • Krishnan, S.C.1    Epstein, L.M.2
  • 11
    • 0031764623 scopus 로고    scopus 로고
    • Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads
    • Paniagua D, Aldrich HR, Lieberman EH, et al. Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads. Am J Cardiol 1998; 82:1130-1132, A9.
    • (1998) Am J Cardiol , vol.82 , pp. 1130-1132
    • Paniagua, D.1    Aldrich, H.R.2    Lieberman, E.H.3
  • 12
    • 0016386893 scopus 로고
    • Perforation of the tricuspid valve by a transvenous pacemaker
    • Gould L, Reddy CV, Yacob U, et al. Perforation of the tricuspid valve by a transvenous pacemaker. JAMA 1974; 230:86-87.
    • (1974) JAMA , vol.230 , pp. 86-87
    • Gould, L.1    Reddy, C.V.2    Yacob, U.3
  • 13
    • 0015538150 scopus 로고
    • Tricuspid valve perforation by endocardial pacing electrode
    • Petterson SR, Singh JB, Reeves G, et al. Tricuspid valve perforation by endocardial pacing electrode. Chest 1973; 63:125-126.
    • (1973) Chest , vol.63 , pp. 125-126
    • Petterson, S.R.1    Singh, J.B.2    Reeves, G.3
  • 14
    • 0018088331 scopus 로고
    • Dynamic tricuspid valve insufficiency produced by a right ventricular thrombus from a pacemaker
    • Zager J, Berberich SN, Eslava R. et al. Dynamic tricuspid valve insufficiency produced by a right ventricular thrombus from a pacemaker. Chest 1978; 74:455-456.
    • (1978) Chest , vol.74 , pp. 455-456
    • Zager, J.1    Berberich, S.N.2    Eslava, R.3
  • 15
    • 0025812296 scopus 로고
    • Pacemaker-lead puncture of the tricuspid valve. Successful diagnosis and treatment
    • Rubio PA, al Bassam MS. Pacemaker-lead puncture of the tricuspid valve. Successful diagnosis and treatment. Chest 1991; 99:1519-1520.
    • (1991) Chest , vol.99 , pp. 1519-1520
    • Rubio, P.A.1    Al Bassam, M.S.2
  • 16
    • 0031983656 scopus 로고    scopus 로고
    • Large laser sheaths for pacing and defibrillator lead removal
    • Reiser C, Taylor KD, Lippincott RA. Large laser sheaths for pacing and defibrillator lead removal. Lasers Surg Med 1998; 22:42-45.
    • (1998) Lasers Surg Med , vol.22 , pp. 42-45
    • Reiser, C.1    Taylor, K.D.2    Lippincott, R.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.