메뉴 건너뛰기




Volumn 7, Issue 4, 2014, Pages 337-347

3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation

Author keywords

3 dimensional echocardiography; intracardiac defibrillator; pacemaker; tricuspid regurgitation; tricuspid valve

Indexed keywords

ADULT; AGED; ARTICLE; CARDIAC RESYNCHRONIZATION THERAPY DEVICE; DISEASE SEVERITY; FEMALE; FLUOROSCOPY; HEART RIGHT VENTRICLE; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; MAJOR CLINICAL STUDY; MALE; PACEMAKER; PRIORITY JOURNAL; SINUS NODE; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; TRICUSPID VALVE; TRICUSPID VALVE REGURGITATION; ULTRASOUND SCANNER; ULTRASOUND TRANSDUCER; VEIN; VENA CONTRACTA; ARTIFICIAL HEART PACEMAKER; DOPPLER ECHOCARDIOGRAPHY; ECHOGRAPHY; EVALUATION STUDY; FEASIBILITY STUDY; MIDDLE AGED; PATHOPHYSIOLOGY; PREDICTIVE VALUE; RETROSPECTIVE STUDY; RISK FACTOR; SEVERITY OF ILLNESS INDEX; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRICUSPID VALVE INSUFFICIENCY; VERY ELDERLY;

EID: 84898822424     PISSN: 1936878X     EISSN: 18767591     Source Type: Journal    
DOI: 10.1016/j.jcmg.2013.11.007     Document Type: Article
Times cited : (100)

References (38)
  • 1
    • 84857371963 scopus 로고    scopus 로고
    • Prevalence and mechanism of tricuspid regurgitation following implantation of endocardial leads for pacemaker or cardioverter-defibrillator
    • M.A. Al-Mohaissen, and K.L. Chan Prevalence and mechanism of tricuspid regurgitation following implantation of endocardial leads for pacemaker or cardioverter-defibrillator J Am Soc Echocardiogr 25 2012 245 252
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 245-252
    • Al-Mohaissen, M.A.1    Chan, K.L.2
  • 2
    • 70449344705 scopus 로고    scopus 로고
    • Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: Intracardiac findings near their leads and electrodes
    • M. Novak, P. Dvorak, P. Kamaryt, B. Slana, and J. Lipoldova Autopsy and clinical context in deceased patients with implanted pacemakers and defibrillators: intracardiac findings near their leads and electrodes Europace 11 2009 1510 1516
    • (2009) Europace , vol.11 , pp. 1510-1516
    • Novak, M.1    Dvorak, P.2    Kamaryt, P.3    Slana, B.4    Lipoldova, J.5
  • 4
    • 18944371653 scopus 로고    scopus 로고
    • Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads
    • G. Lin, R.A. Nishimura, H.M. Connolly, J.A. Dearani, T.M. Sundt III, and D.L. Hayes Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads J Am Coll Cardiol 45 2005 1672 1675
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1672-1675
    • Lin, G.1    Nishimura, R.A.2    Connolly, H.M.3    Dearani, J.A.4    Sundt III, T.M.5    Hayes, D.L.6
  • 5
    • 0842330731 scopus 로고    scopus 로고
    • Impact of tricuspid regurgitation on long-term survival
    • J. Nath, E. Foster, and P.A. Heidenreich Impact of tricuspid regurgitation on long-term survival J Am Coll Cardiol 43 2004 405 409
    • (2004) J Am Coll Cardiol , vol.43 , pp. 405-409
    • Nath, J.1    Foster, E.2    Heidenreich, P.A.3
  • 6
    • 50549090931 scopus 로고    scopus 로고
    • Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads
    • Y. Seo, T. Ishizu, H. Nakajima, Y. Sekiguchi, S. Watanabe, and K. Aonuma Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads Circ J 72 2008 1465 1470
    • (2008) Circ J , vol.72 , pp. 1465-1470
    • Seo, Y.1    Ishizu, T.2    Nakajima, H.3    Sekiguchi, Y.4    Watanabe, S.5    Aonuma, K.6
  • 7
    • 0031764623 scopus 로고    scopus 로고
    • Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads
    • A9
    • D. Paniagua, H.R. Aldrich, E.H. Lieberman, G.A. Lamas, and A.S. Agatston Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads Am J Cardiol 82 1998 1130 1132 A9
    • (1998) Am J Cardiol , vol.82 , pp. 1130-1132
    • Paniagua, D.1    Aldrich, H.R.2    Lieberman, E.H.3    Lamas, G.A.4    Agatston, A.S.5
  • 8
    • 39749136577 scopus 로고    scopus 로고
    • The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: An observational study
    • J.B. Kim, D.M. Spevack, and P.A. Tunick et al. The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: an observational study J Am Soc Echocardiogr 21 2008 284 287
    • (2008) J Am Soc Echocardiogr , vol.21 , pp. 284-287
    • Kim, J.B.1    Spevack, D.M.2    Tunick, P.A.3
  • 10
    • 0142008980 scopus 로고    scopus 로고
    • Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography
    • W.A. Zoghbi, M. Enriquez-Sarano, and E. Foster et al. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography J Am Soc Echocardiogr 16 2003 777 802
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 777-802
    • Zoghbi, W.A.1    Enriquez-Sarano, M.2    Foster, E.3
  • 11
    • 84055198661 scopus 로고    scopus 로고
    • EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography
    • R.M. Lang, L.P. Badano, and W. Tsang et al. EAE/ASE recommendations for image acquisition and display using three-dimensional echocardiography J Am Soc Echocardiogr 25 2012 3 46
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 3-46
    • Lang, R.M.1    Badano, L.P.2    Tsang, W.3
  • 12
    • 62149107389 scopus 로고    scopus 로고
    • Permanent pacemaker implantation technique: Part II
    • K. Rajappan Permanent pacemaker implantation technique: part II Heart 95 2009 334 342
    • (2009) Heart , vol.95 , pp. 334-342
    • Rajappan, K.1
  • 13
    • 0025812296 scopus 로고
    • Pacemaker-lead puncture of the tricuspid valve. Successful diagnosis and treatment
    • P.A. Rubio, and M.S. al-Bassam Pacemaker-lead puncture of the tricuspid valve. Successful diagnosis and treatment Chest 99 1991 1519 1520
    • (1991) Chest , vol.99 , pp. 1519-1520
    • Rubio, P.A.1    Al-Bassam, M.S.2
  • 14
    • 33747884111 scopus 로고    scopus 로고
    • Tricuspid valve malfunction and ventricular pacemaker lead: Case report and review of the literature
    • S.B. Iskandar, J.S. Ann, S. Fahrig, B.K. Mechleb, and I.D. Garcia Tricuspid valve malfunction and ventricular pacemaker lead: case report and review of the literature Echocardiography 23 2006 692 697
    • (2006) Echocardiography , vol.23 , pp. 692-697
    • Iskandar, S.B.1    Ann, J.S.2    Fahrig, S.3    Mechleb, B.K.4    Garcia, I.D.5
  • 15
    • 80053381658 scopus 로고    scopus 로고
    • Severe tricuspid valve regurgitation due to perforation by permanent pacemaker lead
    • L. Wen-Zong, and M. Liang Severe tricuspid valve regurgitation due to perforation by permanent pacemaker lead J Card Surg 26 2011 555 556
    • (2011) J Card Surg , vol.26 , pp. 555-556
    • Wen-Zong, L.1    Liang, M.2
  • 16
    • 0033918703 scopus 로고    scopus 로고
    • Transvenous pacemaker leads do not worsen tricuspid regurgitation: A prospective echocardiographic study
    • D.W. Leibowitz, S. Rosenheck, A. Pollak, M. Geist, and D. Gilon Transvenous pacemaker leads do not worsen tricuspid regurgitation: a prospective echocardiographic study Cardiology 93 2000 74 77
    • (2000) Cardiology , vol.93 , pp. 74-77
    • Leibowitz, D.W.1    Rosenheck, S.2    Pollak, A.3    Geist, M.4    Gilon, D.5
  • 17
    • 33745608048 scopus 로고    scopus 로고
    • Tricuspid insufficiency does not increase early after permanent implantation of pacemaker leads
    • N. Kucukarslan, A. Kirilmaz, and E. Ulusoy et al. Tricuspid insufficiency does not increase early after permanent implantation of pacemaker leads J Card Surg 21 2006 391 394
    • (2006) J Card Surg , vol.21 , pp. 391-394
    • Kucukarslan, N.1    Kirilmaz, A.2    Ulusoy, E.3
  • 18
    • 0029930973 scopus 로고    scopus 로고
    • Insertion of a pacing lead via the tricuspid valve does not affect cardiac function and tricuspid valve regurgitation in young dogs
    • Y. Kikuchi, H. Shiraishi, H. Igarashi, and M. Yanagisawa Insertion of a pacing lead via the tricuspid valve does not affect cardiac function and tricuspid valve regurgitation in young dogs Acta Paediatr Jpn 38 1996 32 35
    • (1996) Acta Paediatr Jpn , vol.38 , pp. 32-35
    • Kikuchi, Y.1    Shiraishi, H.2    Igarashi, H.3    Yanagisawa, M.4
  • 19
    • 0035574102 scopus 로고    scopus 로고
    • Permanent cardiac pacing and its influence on tricuspid valve function
    • W. Krupa, D. Kozlowski, P. Derejko, and G. Swiatecka Permanent cardiac pacing and its influence on tricuspid valve function Folia Morphol (Warsz) 60 2001 249 257
    • (2001) Folia Morphol (Warsz) , vol.60 , pp. 249-257
    • Krupa, W.1    Kozlowski, D.2    Derejko, P.3    Swiatecka, G.4
  • 20
    • 80054946071 scopus 로고    scopus 로고
    • Induction and aggravation of atrioventricular valve regurgitation in the course of chronic right ventricular apical pacing
    • A. Alizadeh, H.R. Sanati, and M. Haji-Karimi et al. Induction and aggravation of atrioventricular valve regurgitation in the course of chronic right ventricular apical pacing Europace 13 2011 1587 1590
    • (2011) Europace , vol.13 , pp. 1587-1590
    • Alizadeh, A.1    Sanati, H.R.2    Haji-Karimi, M.3
  • 21
    • 33747033202 scopus 로고    scopus 로고
    • Geometric determinants of functional tricuspid regurgitation: Insights from 3-dimensional echocardiography
    • T.T. Ton-Nu, R.A. Levine, and M.D. Handschumacher et al. Geometric determinants of functional tricuspid regurgitation: insights from 3-dimensional echocardiography Circulation 114 2006 143 149
    • (2006) Circulation , vol.114 , pp. 143-149
    • Ton-Nu, T.T.1    Levine, R.A.2    Handschumacher, M.D.3
  • 22
    • 67650536002 scopus 로고    scopus 로고
    • Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography
    • L.P. Badano, E. Agricola, L. Perez de Isla, P. Gianfagna, and J.L. Zamorano Evaluation of the tricuspid valve morphology and function by transthoracic real-time three-dimensional echocardiography Eur J Echocardiogr 10 2009 477 484
    • (2009) Eur J Echocardiogr , vol.10 , pp. 477-484
    • Badano, L.P.1    Agricola, E.2    Perez De Isla, L.3    Gianfagna, P.4    Zamorano, J.L.5
  • 23
    • 79955914187 scopus 로고    scopus 로고
    • Evaluation of tricuspid valve morphology and function by transthoracic three-dimensional echocardiography
    • D. Muraru, L.P. Badano, C. Sarais, E. Solda, and S. Iliceto Evaluation of tricuspid valve morphology and function by transthoracic three-dimensional echocardiography Curr Cardiol Rep 13 2011 242 249
    • (2011) Curr Cardiol Rep , vol.13 , pp. 242-249
    • Muraru, D.1    Badano, L.P.2    Sarais, C.3    Solda, E.4    Iliceto, S.5
  • 24
    • 80054991092 scopus 로고    scopus 로고
    • Valvular heart disease. The value of 3-dimensional echocardiography
    • R.M. Lang, W. Tsang, L. Weinert, V. Mor-Avi, and S. Chandra Valvular heart disease. The value of 3-dimensional echocardiography J Am Coll Cardiol 58 2011 1933 1944
    • (2011) J Am Coll Cardiol , vol.58 , pp. 1933-1944
    • Lang, R.M.1    Tsang, W.2    Weinert, L.3    Mor-Avi, V.4    Chandra, S.5
  • 25
    • 35848945234 scopus 로고    scopus 로고
    • Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography
    • A.M. Anwar, M.L. Geleijnse, and O.I. Soliman et al. Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography Int J Cardiovasc Imaging 23 2007 717 724
    • (2007) Int J Cardiovasc Imaging , vol.23 , pp. 717-724
    • Anwar, A.M.1    Geleijnse, M.L.2    Soliman, O.I.3
  • 26
    • 0033859084 scopus 로고    scopus 로고
    • Quantification of tricuspid regurgitation by measuring the width of the vena contracta with Doppler color flow imaging: A clinical study
    • C.M. Tribouilloy, M. Enriquez-Sarano, K.R. Bailey, A.J. Tajik, and J.B. Seward Quantification of tricuspid regurgitation by measuring the width of the vena contracta with Doppler color flow imaging: a clinical study J Am Coll Cardiol 36 2000 472 478
    • (2000) J Am Coll Cardiol , vol.36 , pp. 472-478
    • Tribouilloy, C.M.1    Enriquez-Sarano, M.2    Bailey, K.R.3    Tajik, A.J.4    Seward, J.B.5
  • 27
    • 0030779284 scopus 로고    scopus 로고
    • Vena contracta imaged by Doppler color flow mapping predicts the severity of eccentric mitral regurgitation better than color jet area: A chronic animal study
    • X. Zhou, M. Jones, T. Shiota, I. Yamada, D. Teien, and D.J. Sahn Vena contracta imaged by Doppler color flow mapping predicts the severity of eccentric mitral regurgitation better than color jet area: a chronic animal study J Am Coll Cardiol 30 1997 1393 1398
    • (1997) J Am Coll Cardiol , vol.30 , pp. 1393-1398
    • Zhou, X.1    Jones, M.2    Shiota, T.3    Yamada, I.4    Teien, D.5    Sahn, D.J.6
  • 28
    • 0023598043 scopus 로고
    • [Tricuspid regurgitation induced by transvenous right ventricular pacing: Echocardiographic and pathological observations]
    • M. Sakai, S. Ohkawa, and K. Ueda et al. [Tricuspid regurgitation induced by transvenous right ventricular pacing: echocardiographic and pathological observations] J Cardiol 17 1987 311 320
    • (1987) J Cardiol , vol.17 , pp. 311-320
    • Sakai, M.1    Ohkawa, S.2    Ueda, K.3
  • 29
    • 77955882203 scopus 로고    scopus 로고
    • Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode
    • M. Vaturi, J. Kusniec, and Y. Shapira et al. Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode Eur J Echocardiogr 11 2010 550 553
    • (2010) Eur J Echocardiogr , vol.11 , pp. 550-553
    • Vaturi, M.1    Kusniec, J.2    Shapira, Y.3
  • 30
    • 34250752270 scopus 로고    scopus 로고
    • Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: Role of real time three-dimensional echocardiography
    • G. Nucifora, L.P. Badano, and G. Allocca et al. Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: role of real time three-dimensional echocardiography Echocardiography 24 2007 649 652
    • (2007) Echocardiography , vol.24 , pp. 649-652
    • Nucifora, G.1    Badano, L.P.2    Allocca, G.3
  • 31
    • 84883755717 scopus 로고    scopus 로고
    • Proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography applied for tricuspid regurgitation quantification
    • J.A. de Agustin, D. Viliani, and C. Vieira et al. Proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography applied for tricuspid regurgitation quantification J Am Soc Echocardiogr 26 2013 1063 1072
    • (2013) J Am Soc Echocardiogr , vol.26 , pp. 1063-1072
    • De Agustin, J.A.1    Viliani, D.2    Vieira, C.3
  • 32
    • 0015325802 scopus 로고
    • Cardiac pathology of transvenous pacemakers
    • T.Y. Huang, and N. Baba Cardiac pathology of transvenous pacemakers Am Heart J 83 1972 469 474
    • (1972) Am Heart J , vol.83 , pp. 469-474
    • Huang, T.Y.1    Baba, N.2
  • 33
    • 84872091789 scopus 로고    scopus 로고
    • Heart disease and stroke statistics - 2013 update: A report from the American Heart Association
    • A.S. Go, D. Mozaffarian, and V.L. Roger et al. Heart disease and stroke statistics - 2013 update: a report from the American Heart Association Circulation 127 2013 e6 245
    • (2013) Circulation , vol.127 , pp. 6-245
    • Go, A.S.1    Mozaffarian, D.2    Roger, V.L.3
  • 34
    • 37349020985 scopus 로고    scopus 로고
    • Cardiac device implantation in the United States from 1997 through 2004: A population-based analysis
    • C. Zhan, W.B. Baine, A. Sedrakyan, and C. Steiner Cardiac device implantation in the United States from 1997 through 2004: a population-based analysis J Gen Intern Med 23 Suppl 1 2008 13 19
    • (2008) J Gen Intern Med , vol.23 , Issue.SUPPL. 1 , pp. 13-19
    • Zhan, C.1    Baine, W.B.2    Sedrakyan, A.3    Steiner, C.4
  • 35
    • 57649198104 scopus 로고    scopus 로고
    • Outcomes of tricuspid valve repair and replacement: A propensity analysis
    • R.J. Moraca, M.R. Moon, and J.S. Lawton et al. Outcomes of tricuspid valve repair and replacement: a propensity analysis Ann Thorac Surg 87 2009 83 88
    • (2009) Ann Thorac Surg , vol.87 , pp. 83-88
    • Moraca, R.J.1    Moon, M.R.2    Lawton, J.S.3
  • 36
    • 12144288888 scopus 로고    scopus 로고
    • Tricuspid valve repair: Durability and risk factors for failure
    • P.M. McCarthy, S.K. Bhudia, and J. Rajeswaran et al. Tricuspid valve repair: durability and risk factors for failure J Thorac Cardiovasc Surg 127 2004 674 685
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 674-685
    • McCarthy, P.M.1    Bhudia, S.K.2    Rajeswaran, J.3
  • 38
    • 84874439734 scopus 로고    scopus 로고
    • Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation
    • M.N. Nazmul, Y.M. Cha, G. Lin, S.J. Asirvatham, and B.D. Powell Percutaneous pacemaker or implantable cardioverter-defibrillator lead removal in an attempt to improve symptomatic tricuspid regurgitation Europace 15 2013 409 413
    • (2013) Europace , vol.15 , pp. 409-413
    • Nazmul, M.N.1    Cha, Y.M.2    Lin, G.3    Asirvatham, S.J.4    Powell, B.D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.