메뉴 건너뛰기




Volumn 38, Issue 11, 2015, Pages 1267-1274

Tricuspid Regurgitation Following Implantation of Endocardial Leads: Incidence and Predictors

Author keywords

endocardial lead; pacemaker; tricuspid regurgitation

Indexed keywords

AGE; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; ATRIAL FIBRILLATION; CONTROLLED STUDY; DISEASE EXACERBATION; DISEASE SEVERITY; ECHOCARDIOGRAPHY; FEMALE; HEART LEFT ATRIUM; HEART RIGHT ATRIUM; HEART RIGHT VENTRICLE PRESSURE; HEART VENTRICLE PACING; HUMAN; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; INCIDENCE; MAJOR CLINICAL STUDY; MALE; MITRAL VALVE REGURGITATION; OBSERVER VARIATION; PACEMAKER IMPLANTATION; PREDICTION; TRICUSPID VALVE REGURGITATION; ADVERSE EFFECTS; ECHOGRAPHY; ENDOCARDIUM; PREDICTIVE VALUE; PROSTHESIS IMPLANTATION; RETROSPECTIVE STUDY; TRICUSPID VALVE INSUFFICIENCY;

EID: 84945459606     PISSN: 01478389     EISSN: 15408159     Source Type: Journal    
DOI: 10.1111/pace.12701     Document Type: Article
Times cited : (57)

References (18)
  • 1
    • 18944371653 scopus 로고    scopus 로고
    • Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter defibrillator leads
    • Lin G, Nishimura RA, Connolly HM, Dearani JA, Sundt TM, Hayes DL,. Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter defibrillator leads. J Am Coll Cardiol 2005; 45: 1672-1675.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1672-1675
    • Lin, G.1    Nishimura, R.A.2    Connolly, H.M.3    Dearani, J.A.4    Sundt, T.M.5    Hayes, D.L.6
  • 2
    • 84857371963 scopus 로고    scopus 로고
    • Prevalence and mechanism of tricuspid regurgication following implantation of endocardial leads for pacemaker or cardioverter-defibrillator
    • Al-Mohaissen MA, Chan KL,. Prevalence and mechanism of tricuspid regurgication following implantation of endocardial leads for pacemaker or cardioverter-defibrillator. J Am Soc Echo 2012; 25: 245-252.
    • (2012) J Am Soc Echo , vol.25 , pp. 245-252
    • Al-Mohaissen, M.A.1    Chan, K.L.2
  • 3
    • 77955882203 scopus 로고    scopus 로고
    • Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode
    • Vaturi M, Kusniec J, Shapira Y, Nevzorov R, Yedidya I, Weisenberg D, Monakier D, et al., Right ventricular pacing increases tricuspid regurgitation grade regardless of the mechanical interference to the valve by the electrode. Eur J Echocardiogr 2010; 11: 550-553.
    • (2010) Eur J Echocardiogr , vol.11 , pp. 550-553
    • Vaturi, M.1    Kusniec, J.2    Shapira, Y.3    Nevzorov, R.4    Yedidya, I.5    Weisenberg, D.6    Monakier, D.7
  • 5
    • 50549090931 scopus 로고    scopus 로고
    • Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads
    • Seo Y, Ishizu T, Nakajima H, Sekiguchi Y, Watanabe S, Aonuma K,. Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads. Circ J 2008; 72: 1465-1470.
    • (2008) Circ J , vol.72 , pp. 1465-1470
    • Seo, Y.1    Ishizu, T.2    Nakajima, H.3    Sekiguchi, Y.4    Watanabe, S.5    Aonuma, K.6
  • 6
    • 39749136577 scopus 로고    scopus 로고
    • The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: An observational study
    • Kim JB, Spevack DM, Tunick PA, Bullinga JR, Kronzon I, Chinitz LA, Reynolds HR,. The effect of transvenous pacemaker and implantable cardioverter defibrillator lead placement on tricuspid valve function: An observational study. J Am Soc Echo 2008; 21: 284-287.
    • (2008) J Am Soc Echo , vol.21 , pp. 284-287
    • Kim, J.B.1    Spevack, D.M.2    Tunick, P.A.3    Bullinga, J.R.4    Kronzon, I.5    Chinitz, L.A.6    Reynolds, H.R.7
  • 7
    • 0031764623 scopus 로고    scopus 로고
    • Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads
    • Paniagua D, Aldrich HR, Lieberman EH, Lamas GA, Agatston AS,. Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads. Am J Cardiol 1998; 82: 1130-1132.
    • (1998) Am J Cardiol , vol.82 , pp. 1130-1132
    • Paniagua, D.1    Aldrich, H.R.2    Lieberman, E.H.3    Lamas, G.A.4    Agatston, A.S.5
  • 8
    • 0033918703 scopus 로고    scopus 로고
    • Transvenous pacemaker leads do not worsen tricuspid regurgitation: A prospective echocardiographic study
    • Leibowitz DW, Rosenheck S, Pollak A, Geist M,. Transvenous pacemaker leads do not worsen tricuspid regurgitation: A prospective echocardiographic study. Cardiology 2000; 93: 74-77.
    • (2000) Cardiology , vol.93 , pp. 74-77
    • Leibowitz, D.W.1    Rosenheck, S.2    Pollak, A.3    Geist, M.4
  • 9
    • 0034095039 scopus 로고    scopus 로고
    • Long-term outcome of patients with multiple (≥3) non-infected transvenous leads: A clinical and echocardiographic study
    • De Cock CC, Vinkers M, Van Campe LCMC, Verhorst PMJ, Visser CA,. Long-term outcome of patients with multiple (≥3) non-infected transvenous leads: A clinical and echocardiographic study. Pacing Clin Electrophysiol 2000; 23: 423-426.
    • (2000) Pacing Clin Electrophysiol , vol.23 , pp. 423-426
    • De Cock, C.C.1    Vinkers, M.2    Van Campe, L.3    Verhorst, P.M.J.4    Visser, C.A.5
  • 11
    • 84877748258 scopus 로고    scopus 로고
    • Tricuspid regurgitation in patients with pacemakers and implantable cardiac defibrillators: A comprehensive review
    • Al-Bawardy R, Krishnaswamy A, Bhargava M, Dunn J, Wazni O, Tuzcu EM, Stewart W, et al., Tricuspid regurgitation in patients with pacemakers and implantable cardiac defibrillators: A comprehensive review. Clin Cardiol 2013; 36: 249-254.
    • (2013) Clin Cardiol , vol.36 , pp. 249-254
    • Al-Bawardy, R.1    Krishnaswamy, A.2    Bhargava, M.3    Dunn, J.4    Wazni, O.5    Tuzcu, E.M.6    Stewart, W.7
  • 13
    • 33646232219 scopus 로고    scopus 로고
    • Prevention of ventricular desynchronization by permanent para-Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: A crossover, blinded, randomized study versus apical right ventricular pacing
    • Ochetta E, Bortnik M, Magnani A, Francalacci G, Piccinino C, Plebani L, Marino P,. Prevention of ventricular desynchronization by permanent para-Hisian pacing after atrioventricular node ablation in chronic atrial fibrillation: A crossover, blinded, randomized study versus apical right ventricular pacing. J Am Coll Cardiol 2006; 47: 1938-1945.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1938-1945
    • Ochetta, E.1    Bortnik, M.2    Magnani, A.3    Francalacci, G.4    Piccinino, C.5    Plebani, L.6    Marino, P.7
  • 14
    • 33750968221 scopus 로고    scopus 로고
    • Right ventricular apex versus right ventricular outflow tract pacing: Prospective, randomized, long-term clinical and echocardiographic evaluation
    • Lewicka-Nowak E, Dabrowska-Kugacka A, Tybura S, Krzymińska-Stasiuk E, Wilczek R, Staniewicz J, Swiatecka G, et al., Right ventricular apex versus right ventricular outflow tract pacing: Prospective, randomized, long-term clinical and echocardiographic evaluation. Kardiol Pol 2006; 64: 1082-1091.
    • (2006) Kardiol Pol , vol.64 , pp. 1082-1091
    • Lewicka-Nowak, E.1    Dabrowska-Kugacka, A.2    Tybura, S.3    Krzymińska-Stasiuk, E.4    Wilczek, R.5    Staniewicz, J.6    Swiatecka, G.7
  • 15
    • 84939988550 scopus 로고    scopus 로고
    • Localization of pacing and defibrillator leads using standard x-ray views is frequently inaccurate and is not reproducible
    • Jackson LR, Piccini JP, Daubert JP, Hurwitz Koweek LM, Atwater BD,. Localization of pacing and defibrillator leads using standard x-ray views is frequently inaccurate and is not reproducible. J Interv Card Electrophysiol 2015; 43: 5-12.
    • (2015) J Interv Card Electrophysiol , vol.43 , pp. 5-12
    • Jackson, L.R.1    Piccini, J.P.2    Daubert, J.P.3    Hurwitz, K.L.4    Atwater, B.D.5
  • 16
    • 0842330731 scopus 로고    scopus 로고
    • Impact of tricuspid regurgitation on long-term survival
    • Nath J, Foster E, Heidenreich PA,. Impact of tricuspid regurgitation on long-term survival. J Am Coll Cardiol 2004; 43: 405-409.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 405-409
    • Nath, J.1    Foster, E.2    Heidenreich, P.A.3
  • 17
    • 67449085333 scopus 로고    scopus 로고
    • The tricuspid valve: Current perspective and evolving management of tricuspid regurgitation
    • Rogers JH, Bolling SF,. The tricuspid valve: Current perspective and evolving management of tricuspid regurgitation. Circ 2009; 119: 2718-2725.
    • (2009) Circ , vol.119 , pp. 2718-2725
    • Rogers, J.H.1    Bolling, S.F.2
  • 18
    • 84875032941 scopus 로고    scopus 로고
    • Tricuspid regurgitation following implantation of a pacemaker/cardioverter defibrillator
    • Al-Mohaissen MA, Chan KL,. Tricuspid regurgitation following implantation of a pacemaker/cardioverter defibrillator. Curr Cardiol Rep 2013; 15: 357-364.
    • (2013) Curr Cardiol Rep , vol.15 , pp. 357-364
    • Al-Mohaissen, M.A.1    Chan, K.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.