메뉴 건너뛰기




Volumn 373, Issue 12, 2015, Pages 1125-1135

Percutaneous implantation of an entirely intracardiac leadless pacemaker

(15)  Reddy, Vivek Y a   Exner, Derek V c   Cantillon, Daniel J d   Doshi, Rahul e   Bunch, T Jared g   Tomassoni, Gery F h   Friedman, Paul A i   Estes, N A Mark j   Ip, John k   Niazi, Imran l   Plunkitt, Kenneth m   Banker, Rajesh f   Porterfield, James n   Ip, James E b   Dukkipati, Srinivas R a  


Author keywords

[No Author keywords available]

Indexed keywords

ACUTE CONFUSION; ADULT; AGED; ANGINA PECTORIS; ARTERIOVENOUS FISTULA; ARTICLE; ATAXIC APHASIA; ATRIAL FIBRILLATION; ATRIOVENTRICULAR BLOCK; BLEEDING; BRAIN ISCHEMIA; CLINICAL EFFECTIVENESS; COHORT ANALYSIS; DEVICE SAFETY; DYSARTHRIA; EQUIPMENT DESIGN; FALSE ANEURYSM; FEMALE; FOLLOW UP; HEART ARREST; HEART PERFORATION; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HEMATOTHORAX; HUMAN; INTRACARDIAC LEADLESS PACEMAKER; LENGTH OF STAY; LETHARGY; LIMB WEAKNESS; LUNG EMBOLISM; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; MULTICENTER STUDY; ORTHOSTATIC HYPOTENSION; PACEMAKER; PACEMAKER DISLODGEMENT; PACEMAKER IMPLANTATION; PERICARDITIS; PRIORITY JOURNAL; R WAVE; TREATMENT INDICATION; TREATMENT OUTCOME; ADVERSE EFFECTS; ARRHYTHMIAS, CARDIAC; ARTIFICIAL HEART PACEMAKER; CLINICAL TRIAL; DEVICE FAILURE; ELECTROCARDIOGRAPHY; ELECTRODE IMPLANT; INTENTION TO TREAT ANALYSIS; MIDDLE AGED; MORTALITY; PROSPECTIVE STUDY; VERY ELDERLY;

EID: 84942021935     PISSN: 00284793     EISSN: 15334406     Source Type: Journal    
DOI: 10.1056/NEJMoa1507192     Document Type: Article
Times cited : (399)

References (21)
  • 1
    • 43749117056 scopus 로고    scopus 로고
    • A report of the American college of cardiology/American Heart Association task force on practice guidelines (writing comm i ttee to revise the acc/AHA/naspe 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices) developed in collaboration with the American association for thoracic surgery and society of thoracic surgeons
    • ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities
    • Epstein AE, DiM arco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Comm i ttee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. J Am Coll Cardio l 2008; 51(21): e1-e62.
    • (2008) J Am Coll Cardiol , vol.51 , Issue.21 , pp. e1-e62
    • Epstein, A.E.1    Dimarco, J.P.2    Ellenbogen, K.A.3
  • 2
    • 80051705189 scopus 로고    scopus 로고
    • The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: Calendar year 2009-A world society of arrhythmia's project
    • Mond HG, Proclemer A. The 11th world survey of cardiac pacing and implantable cardioverter-defibrillators: calendar year 2009-A World Society of Arrhythmia's project. Pac ing Clin Electrophysiol 2011; 34: 1013-27.
    • (2011) Pacing Clin Electrophysiol , vol.34 , pp. 1013-1027
    • Mond, H.G.1    Proclemer, A.2
  • 3
    • 84900324755 scopus 로고    scopus 로고
    • Complications after cardiac implantable electronic device implantations: An analysis of a complete, nationwide cohort in Denmark
    • Kirkfeldt RE, Johansen JB, Nohr EA, Jørgensen OD, Nielsen JC. Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. Eur Heart J 2014; 35: 1186-94.
    • (2014) Eur Heart J , vol.35 , pp. 1186-1194
    • Kirkfeldt, R.E.1    Johansen, J.B.2    Nohr, E.A.3    Jørgensen, O.D.4    Nielsen, J.C.5
  • 4
    • 84860006833 scopus 로고    scopus 로고
    • Incidence and predictors of shortand long-term complications in pacemaker t herapy: The followpace study
    • Udo EO, Zuithoff NP, van Hemel NM, et al. Incidence and predictors of shortand long-term complications in pacemaker t herapy: the FOLLOWPACE study. Heart Rhythm 2012; 9: 728-35.
    • (2012) Heart Rhythm , vol.9 , pp. 728-735
    • Udo, E.O.1    Zuithoff, N.P.2    Van Hemel, N.M.3
  • 5
    • 33846471573 scopus 로고    scopus 로고
    • Clinical experience with pacemaker pulse generators and transvenous leads: An 8-year prosp ective multicenter study
    • Hauser RG,Hayes DL,Kallinen LM,et al. Clinical experience with pacemaker pulse generators and transvenous leads: an 8-year prosp ective multicenter study Heart Rhythm 2007 4 154-60.
    • (2007) Heart Rhythm , vol.4 , pp. 154-160
    • Hauser, R.G.1    Hayes, D.L.2    Kallinen, L.M.3
  • 6
    • 34548695954 scopus 로고    scopus 로고
    • Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: Results of a large prospective study
    • Klug D, Balde M, Pavin D, et al. Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study. Circulation 2007; 116: 1349-55.
    • (2007) Circulation , vol.116 , pp. 1349-1355
    • Klug, D.1    Balde, M.2    Pavin, D.3
  • 7
    • 79954544684 scopus 로고    scopus 로고
    • Infection after pacemaker implantation: Infection ra tes and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients
    • Johansen JB, Jørgensen OD, Møller M, Arnsbo P, Mortensen PT, Nielsen JC. Infection after pacemaker implantation: infection ra tes and risk factors associated with infection in a population-based cohort study of 46299 consecutive patients. Eur Heart J 2011; 32: 991-8.
    • (2011) Eur Heart J , vol.32 , pp. 991-998
    • Johansen, J.B.1    Jørgensen, O.D.2    Møller, M.3    Arnsbo, P.4    Mortensen, P.T.5    Nielsen, J.C.6
  • 8
    • 34250701153 scopus 로고    scopus 로고
    • Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: A contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade
    • Haghjoo M, Nikoo MH, Fazelifar AF, Alizadeh A, Emkanjoo Z, Sadr-Ameli MA. Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade. Europace 2007; 9: 328-32.
    • (2007) Europace , vol.9 , pp. 328-332
    • Haghjoo, M.1    Nikoo, M.H.2    Fazelifar, A.F.3    Alizadeh, A.4    Emkanjoo, Z.5    Sadr-Ameli, M.A.6
  • 10
    • 84876001481 scopus 로고    scopus 로고
    • Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: Large population survey from two centres in Italy
    • Palmisano P, Accogli M, Zaccaria M, et al. Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: large population survey from two centres in Italy. Europace 2013; 15: 531-40.
    • (2013) Europace , vol.15 , pp. 531-540
    • Palmisano, P.1    Accogli, M.2    Zaccaria, M.3
  • 11
    • 0034654472 scopus 로고    scopus 로고
    • Acute complications of permanent pacemaker implantation: The ir financial implication and relation to volume and operator experience
    • Tobin K, Stewart J, Westveer D, Frumin H. Acute complications of permanent pacemaker implantation: the ir financial implication and relation to volume and operator experience. Am J Cardiol 2000; 85: 774-6.
    • (2000) Am J Cardiol , vol.85 , pp. 774-776
    • Tobin, K.1    Stewart, J.2    Westveer, D.3    Frumin, H.4
  • 12
    • 84857371963 scopus 로고    scopus 로고
    • Prevalence and mechanism of tricuspid regurgitation following implanta tion of endocardial leads for pacemaker or cardioverter-defibrillator
    • Al-Mohaissen MA, Chan KL. Prevalence and mechanism of tricuspid regurgitation following implanta tion of endocardial leads for pacemaker or cardioverter-defibrillator. J Am Soc Echocardiogr 2012; 25: 245-52.
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 245-252
    • Al-Mohaissen, M.A.1    Chan, K.L.2
  • 13
    • 84898046591 scopus 로고    scopus 로고
    • Permanent leadless cardiac pacing: Results of the leadless trial
    • Reddy VY, Knops RE, Sperzel JS, et al. Permanent leadless cardiac pacing: results of the LEADLESS trial. Circulation 2014; 129: 1466-71.
    • (2014) Circulation , vol.129 , pp. 1466-1471
    • Reddy, V.Y.1    Knops, R.E.2    Sperzel, J.S.3
  • 14
    • 84928024666 scopus 로고    scopus 로고
    • Chronic performance of a leadless cardiac pacemaker: 1-year follow-up of the leadless trial
    • Knops RE, Tjong FVY, Neuzil P, et al. Chronic performance of a leadless cardiac pacemaker: 1-year follow-up of the LEADLESS trial. J Am Coll Cardiol 2015; 65: 1497-504.
    • (2015) J Am Coll Cardiol , vol.65 , pp. 1497-1504
    • Knops, R.E.1    Tjong, F.V.Y.2    Neuzil, P.3
  • 15
    • 84884670759 scopus 로고    scopus 로고
    • Stroke or transient ischemic attack in patients with transvenous pacemaker or defibrillator and echocardiogra phically detected patent foramen ovale
    • DeSimone CV, Friedman PA, Noheria A, et al. Stroke or transient ischemic attack in patients with transvenous pacemaker or defibrillator and echocardiogra phically detected patent foramen ovale. Circulation 2013; 128: 1433-41.
    • (2013) Circulation , vol.128 , pp. 1433-1441
    • DeSimone, C.V.1    Friedman, P.A.2    Noheria, A.3
  • 16
    • 0037071799 scopus 로고    scopus 로고
    • Ventricular pacing or dual-chamber pacing for sinus-node dysfunction
    • Lamas GA, Lee KL, Sweeney MO, et al. Ventricular pacing or dual-chamber pacing for sinus-node dysfunction. N Engl J Med 2002; 346: 1854-62.
    • (2002) N Engl J Med , vol.346 , pp. 1854-1862
    • Lamas, G.A.1    Lee, K.L.2    Sweeney, M.O.3
  • 17
    • 78650670809 scopus 로고    scopus 로고
    • Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment
    • Wilkoff BL, Bello D, Taborsky M, et al. Magnetic resonance imaging in patients with a pacemaker system designed for the magnetic resonance environment. Heart R hythm 2011; 8: 65-73.
    • (2011) Heart R Hythm , vol.8 , pp. 65-73
    • Wilkoff, B.L.1    Bello, D.2    Taborsky, M.3
  • 18
    • 33746233396 scopus 로고    scopus 로고
    • Cardiovascular outcomes with atrialbased pacing compared with ventricular pacing: Meta-Analysis of randomized trials, using individual p atient data
    • Healey JS, Toff WD, Lamas GA, et al. Cardiovascular outcomes with atrialbased pacing compared with ventricular pacing: meta-Analysis of randomized trials, using individual p atient data. Circulation 2006; 114: 11-7.
    • (2006) Circulation , vol.114 , pp. 11-17
    • Healey, J.S.1    Toff, W.D.2    Lamas, G.A.3
  • 19
    • 25444441460 scopus 로고    scopus 로고
    • Incidence and predictors of cardiac perforation after permanent pacemaker placement
    • Mahapatra S, Bybee KA, Bunch TJ, et al. Incidence and predictors of cardiac perforation after permanent pacemaker placement. Heart Rhythm 2005; 2: 907-11.
    • (2005) Heart Rhythm , vol.2 , pp. 907-911
    • Mahapatra, S.1    Bybee, K.A.2    Bunch, T.J.3
  • 20
    • 84924211358 scopus 로고    scopus 로고
    • Increased perforation risk with an mriconditional pacing lead: A single-center study
    • Acha MR, Keaney JJ, Lubitz SA, et al. Increased perforation risk with an MRIconditional pacing lead: a single-center study. Pacing Clin Electrophysiol 2015; 38: 334-42.
    • (2015) Pacing Clin Electrophysiol , vol.38 , pp. 334-342
    • Acha, M.R.1    Keaney, J.J.2    Lubitz, S.A.3
  • 21
    • 84940476913 scopus 로고    scopus 로고
    • Early performance of a miniaturized leadless cardiac pacemaker: The micra transcatheter pacing study
    • June 4 (Epub ahead of print)
    • Ritter P, Duray GZ, Steinwender C, et al. Early performance of a miniaturized leadless cardiac pacemaker: the Micra Transcatheter Pacing Study. Eur Heart J 2015 June 4 (Epub ahead of print).
    • (2015) Eur Heart J
    • Ritter, P.1    Duray, G.Z.2    Steinwender, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.