메뉴 건너뛰기




Volumn 72, Issue 9, 2008, Pages 1465-1470

Clinical utility of 3-dimensional echocardiography in the evaluation of tricuspid regurgitation caused by pacemaker leads

Author keywords

Echocardiography; Pacing; Valvular diseases

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CARDIAC RESYNCHRONIZATION THERAPY; DEFIBRILLATOR; DISEASE SEVERITY; EVALUATION; FEMALE; HEART RIGHT ATRIUM; HEART SEPTUM DEFECT; HUMAN; MAJOR CLINICAL STUDY; MALE; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TRICUSPID VALVE; TRICUSPID VALVE REGURGITATION;

EID: 50549090931     PISSN: 13469843     EISSN: 13474820     Source Type: Journal    
DOI: 10.1253/circj.CJ-08-0227     Document Type: Article
Times cited : (94)

References (22)
  • 1
    • 0015350424 scopus 로고
    • Laceration of the tricuspid valve by a pacemaker wire
    • Fishenfeld J, Lamy Y. Laceration of the tricuspid valve by a pacemaker wire. Chest 1972; 61: 697-698.
    • (1972) Chest , vol.61 , pp. 697-698
    • Fishenfeld, J.1    Lamy, Y.2
  • 3
    • 0015538150 scopus 로고
    • Tricuspid valve perforation by endocardial pacing electrode
    • Petterson SR, Singh JB, Reeves G, Kocot SL. Tricuspid valve perforation by endocardial pacing electrode. Chest 1973; 63: 125-126.
    • (1973) Chest , vol.63 , pp. 125-126
    • Petterson, S.R.1    Singh, J.B.2    Reeves, G.3    Kocot, S.L.4
  • 4
    • 0025812296 scopus 로고
    • Pacemaker-lead puncture of the tricuspid valve: Successful diagnosis and treatment
    • Rubio P, Al-Bassam M. Pacemaker-lead puncture of the tricuspid valve: Successful diagnosis and treatment. Chest 1991; 99: 1519-1520.
    • (1991) Chest , vol.99 , pp. 1519-1520
    • Rubio, P.1    Al-Bassam, M.2
  • 5
    • 33747884111 scopus 로고    scopus 로고
    • Tricuspid valve malfunction and ventricular pacemaker lead: Case report and review of the literature
    • Iskandar SB, Ann Jackson S, Fahrig S, Mechleb BK, Garcia ID. Tricuspid valve malfunction and ventricular pacemaker lead: Case report and review of the literature. Echocardiography 2006; 23: 692-697.
    • (2006) Echocardiography , vol.23 , pp. 692-697
    • Iskandar, S.B.1    Ann Jackson, S.2    Fahrig, S.3    Mechleb, B.K.4    Garcia, I.D.5
  • 6
    • 0031764623 scopus 로고    scopus 로고
    • Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads
    • 1130-1132
    • Paniagua D, Aldrich HR, Lieberman EH, Lamas GA, Agatston AS. Increased prevalence of significant tricuspid regurgitation in patients with transvenous pacemakers leads. Am J Cardiol 1998; 82: 1130-1132, A9.
    • (1998) Am J Cardiol , vol.82
    • Paniagua, D.1    Aldrich, H.R.2    Lieberman, E.H.3    Lamas, G.A.4    Agatston, A.S.5
  • 7
    • 18944371653 scopus 로고    scopus 로고
    • Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads
    • Lin G, Nishimura RA, Connolly HM, Dearani JA, Sundt TM 3rd, Hayes DL. Severe symptomatic tricuspid valve regurgitation due to permanent pacemaker or implantable cardioverter-defibrillator leads. J Am Coll Cardiol 2005; 45: 1672-1675.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1672-1675
    • Lin, G.1    Nishimura, R.A.2    Connolly, H.M.3    Dearani, J.A.4    Sundt 3rd, T.M.5    Hayes, D.L.6
  • 9
    • 33747033202 scopus 로고    scopus 로고
    • Geometric determinants of functional tricuspid regurgitation: Insights from 3-dimensional echocardiography
    • Ton-Nu TT, Levine RA, Handschumacher MD, Dorer DJ, Yosefy C, Fan D, et al. Geometric determinants of functional tricuspid regurgitation: Insights from 3-dimensional echocardiography. Circulation 2006; 114: 143-149.
    • (2006) Circulation , vol.114 , pp. 143-149
    • Ton-Nu, T.T.1    Levine, R.A.2    Handschumacher, M.D.3    Dorer, D.J.4    Yosefy, C.5    Fan, D.6
  • 10
    • 33747158831 scopus 로고    scopus 로고
    • Three-dimensional geometry of the tricuspid annulus in healthy subjects and in patients with functional tricuspid regurgitation: A real-time, 3-dimensional echocardiographic study
    • Fukuda S, Saracino G, Matsumura Y, Daimon M, Tran H, Greenberg NL, et al. Three-dimensional geometry of the tricuspid annulus in healthy subjects and in patients with functional tricuspid regurgitation: A real-time, 3-dimensional echocardiographic study. Circulation 2006; 114(Suppl): I-492-I-498.
    • (2006) Circulation , vol.114 , Issue.SUPPL. , pp. 492-498
    • Fukuda, S.1    Saracino, G.2    Matsumura, Y.3    Daimon, M.4    Tran, H.5    Greenberg, N.L.6
  • 11
    • 34247361699 scopus 로고    scopus 로고
    • Live/real time three-dimensional transthoracic echocardiographic assessment of tricuspid valve pathology: Incremental value over the two-dimensional technique
    • Pothineni KR, Duncan K, Yelamanchili P, Nanda NC, Patel V, Fan P, et al. Live/real time three-dimensional transthoracic echocardiographic assessment of tricuspid valve pathology: Incremental value over the two-dimensional technique. Echocardiography 2007; 24: 541-552.
    • (2007) Echocardiography , vol.24 , pp. 541-552
    • Pothineni, K.R.1    Duncan, K.2    Yelamanchili, P.3    Nanda, N.C.4    Patel, V.5    Fan, P.6
  • 12
    • 34347249115 scopus 로고    scopus 로고
    • Entrapment of permanent pacemaker lead as the cause of tricuspid regurgitation
    • Chen TE, Wang CC, Chern MS, Chu JJ. Entrapment of permanent pacemaker lead as the cause of tricuspid regurgitation. Circ J 2007; 71: 1169-1171.
    • (2007) Circ J , vol.71 , pp. 1169-1171
    • Chen, T.E.1    Wang, C.C.2    Chern, M.S.3    Chu, J.J.4
  • 13
    • 34250752270 scopus 로고    scopus 로고
    • Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: Role of real time three-dimensional echocardiography
    • Nucifora G, Badano LP, Allocca G, Gianfagna P, Proclemer A, Cinello M, et al. Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: Role of real time three-dimensional echocardiography. Echocardiography 2007; 24: 649-652.
    • (2007) Echocardiography , vol.24 , pp. 649-652
    • Nucifora, G.1    Badano, L.P.2    Allocca, G.3    Gianfagna, P.4    Proclemer, A.5    Cinello, M.6
  • 14
    • 0028123042 scopus 로고
    • Assessment of chronic TR by colour Doppler echocardiography: A comparison with angiography in the catheterization room
    • Tunon J, Cordoba M, Rey M, Almeida P, Rabago R, Sanchez-Cascos A, et al. Assessment of chronic TR by colour Doppler echocardiography: A comparison with angiography in the catheterization room. Eur Heart J 1994; 15: 1074-1084.
    • (1994) Eur Heart J , vol.15 , pp. 1074-1084
    • Tunon, J.1    Cordoba, M.2    Rey, M.3    Almeida, P.4    Rabago, R.5    Sanchez-Cascos, A.6
  • 15
    • 0031954872 scopus 로고    scopus 로고
    • Comparison of the proximal flow convergence method and the jet area method for the assessment of the severity of tricuspid regurgitation
    • Grossmann G, Stein M, Kochs M, Hoher M, Koenig W, Hombach V, et al. Comparison of the proximal flow convergence method and the jet area method for the assessment of the severity of tricuspid regurgitation. Eur Heart J 1998; 19: 652-659.
    • (1998) Eur Heart J , vol.19 , pp. 652-659
    • Grossmann, G.1    Stein, M.2    Kochs, M.3    Hoher, M.4    Koenig, W.5    Hombach, V.6
  • 16
    • 0022355748 scopus 로고
    • Continuous wave Doppler determination of right ventricular systolic pressure: A simultaneous Doppler-catheterization study in 127 patients
    • Currie PJ, Seward JB, Chan K, Fyfe DA, Hagler DJ, Mair DD, et al. Continuous wave Doppler determination of right ventricular systolic pressure: A simultaneous Doppler-catheterization study in 127 patients. J Am Coll Cardiol 1985; 6: 750-756.
    • (1985) J Am Coll Cardiol , vol.6 , pp. 750-756
    • Currie, P.J.1    Seward, J.B.2    Chan, K.3    Fyfe, D.A.4    Hagler, D.J.5    Mair, D.D.6
  • 17
    • 0029930973 scopus 로고    scopus 로고
    • Insertion of a pacing lead via the tricuspid valve does not affect cardiac function and tricuspid valve regurgitation in young dogs
    • Kikuchi Y, Shiraishi H, Igarashi H, Yanagisawa M. Insertion of a pacing lead via the tricuspid valve does not affect cardiac function and tricuspid valve regurgitation in young dogs. Acta Paediatr Jpn 1996; 38: 32-35.
    • (1996) Acta Paediatr Jpn , vol.38 , pp. 32-35
    • Kikuchi, Y.1    Shiraishi, H.2    Igarashi, H.3    Yanagisawa, M.4
  • 18
    • 0033918703 scopus 로고    scopus 로고
    • Transvenous pacemaker leads do not worsen tricuspid regurgitation: A prospective echocardiographic study
    • Leibowitz DW, Rosenheck S, Pollak A, Geist M, Gilon D. Transvenous pacemaker leads do not worsen tricuspid regurgitation: A prospective echocardiographic study. Cardiology 2000; 93: 74-77.
    • (2000) Cardiology , vol.93 , pp. 74-77
    • Leibowitz, D.W.1    Rosenheck, S.2    Pollak, A.3    Geist, M.4    Gilon, D.5
  • 20
    • 40849114529 scopus 로고    scopus 로고
    • Large, singlecenter, single-operator experience with transvenous lead extraction: Outcomes and changing indications
    • Jones SO 4th, Eckart RE, Albert CM, Epstein LM. Large, singlecenter, single-operator experience with transvenous lead extraction: Outcomes and changing indications. Heart Rhythm 2008; 5: 520-525.
    • (2008) Heart Rhythm , vol.5 , pp. 520-525
    • Jones 4th, S.O.1    Eckart, R.E.2    Albert, C.M.3    Epstein, L.M.4
  • 22
    • 0036854491 scopus 로고    scopus 로고
    • Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction
    • Roeffel S, Bracke F, Meijer A, Van Gelder B, Van Dantzig JM, Botman CJ, et al. Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction. Pacing Clin Electrophysiol 2002; 25: 1583-1586.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1583-1586
    • Roeffel, S.1    Bracke, F.2    Meijer, A.3    Van Gelder, B.4    Van Dantzig, J.M.5    Botman, C.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.