메뉴 건너뛰기




Volumn 29, Issue 4, 2014, Pages 470-472

Perforated tricuspid valve leaflet resulting from defibrillator leads: A review of the literature

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL PAIN; AGED; BIOPROSTHESIS; CASE REPORT; CHORDA TENDINEA; CHORDA TENDINEA RUPTURE; COLOR ULTRASOUND FLOWMETRY; DEFIBRILLATOR LEAD; DYSPNEA; FEMALE; GERIATRIC PATIENT; HEART EJECTION FRACTION; HEART PALPITATION; HEART RIGHT VENTRICLE FAILURE; HEART VENTRICLE TACHYCARDIA; HUMAN; HYPERTROPHIC CARDIOMYOPATHY; IMPLANTABLE CARDIOVERTER DEFIBRILLATOR; IMPLANTATION; MEDICAL DEVICE COMPLICATION; PERFORATION; PERICARDIUM; REVIEW; THREE DIMENSIONAL IMAGING; TRANSTHORACIC ECHOCARDIOGRAPHY; TREATMENT OUTCOME; TRICUSPID VALVE; TRICUSPID VALVE PERFORATION; VERY ELDERLY; ARTIFICIAL HEART PACEMAKER; CARDIOMYOPATHY, HYPERTROPHIC; DEVICE REMOVAL; TACHYCARDIA, VENTRICULAR; TIME; TRICUSPID VALVE INSUFFICIENCY;

EID: 84904002013     PISSN: 08860440     EISSN: 15408191     Source Type: Journal    
DOI: 10.1111/jocs.12352     Document Type: Review
Times cited : (9)

References (17)
  • 2
    • 84877748258 scopus 로고    scopus 로고
    • Tricuspid regurgitation in patients with pacemakers and implantable cardiac defibrillators: A comprehensive review
    • et al:.
    • Al-Bawardy R, Krishnaswamy A, Bhargava M, et al. Tricuspid regurgitation in patients with pacemakers and implantable cardiac defibrillators: A comprehensive review. Clin Cardiol 2013; 36: 249-254.
    • (2013) Clin Cardiol , vol.36 , pp. 249-254
    • Al-Bawardy, R.1    Krishnaswamy, A.2    Bhargava, M.3
  • 3
    • 43049096406 scopus 로고    scopus 로고
    • Temporal trends in permanent pacemaker implantation: A population-based study
    • et al:.
    • Uslan DZ, Tleyjeh IM, Baddour LM, et al. Temporal trends in permanent pacemaker implantation: A population-based study. Am Heart J 2008; 155: 896-903.
    • (2008) Am Heart J , vol.155 , pp. 896-903
    • Uslan, D.Z.1    Tleyjeh, I.M.2    Baddour, L.M.3
  • 5
    • 0015538150 scopus 로고
    • Tricuspid valve perforation by endocardial pacing electrode
    • et al:.
    • Petterson SR, Singh JB, Reeves G, et al. Tricuspid valve perforation by endocardial pacing electrode. Chest 1973; 63: 125-126.
    • (1973) Chest , vol.63 , pp. 125-126
    • Petterson, S.R.1    Singh, J.B.2    Reeves, G.3
  • 6
    • 0016386893 scopus 로고
    • Perforation of the tricuspid valve by a transvenous pacemaker
    • et al:.
    • Gould L, Reddy CV, Yacob U, et al. Perforation of the tricuspid valve by a transvenous pacemaker. JAMA 1974; 230: 86-87.
    • (1974) JAMA , vol.230 , pp. 86-87
    • Gould, L.1    Reddy, C.V.2    Yacob, U.3
  • 7
    • 0017031619 scopus 로고
    • Fatal outcome arising from use of a sutureless 'corkscrew' epicardial pacing electrode inserted into apex of left ventricle
    • Vecht RJ, Fontaine CJ, Bradfield JW:, Fatal outcome arising from use of a sutureless "corkscrew" epicardial pacing electrode inserted into apex of left ventricle. Br Heart J 1976; 38: 1359-1362. (Pubitemid 8015302)
    • (1976) British Heart Journal , vol.38 , Issue.12 , pp. 1359-1362
    • Vecht, R.J.1    Fontaine, C.J.2    Bradfield, J.W.B.3
  • 8
    • 0022657704 scopus 로고
    • Tricuspid valve perforation by a permanent pacing lead in a patient with cardiac amyloidosis: Case report and brief literature review
    • DOI 10.1111/j.1540-8159.1986.tb05368.x
    • Christie JL, Keelan MH:, Tricuspid valve perforation by a permanent pacing lead in a patient with cardiac amyloidosis: Case report and brief literature review. Pacing Clin Electrophysiol 1986; 9: 124-126. (Pubitemid 16181872)
    • (1986) PACE - Pacing and Clinical Electrophysiology , vol.9 , Issue.1 , pp. 124-126
    • Christie, J.L.1    Keelan Jr., M.H.2
  • 9
    • 0025812296 scopus 로고
    • Pacemaker-lead puncture of the tricuspid valve. Successful diagnosis and treatment
    • Rubio PA, Al-Bassam MS:, Pacemaker-lead puncture of the tricuspid valve. Successful diagnosis and treatment. Chest 1991; 99: 1519-1520.
    • (1991) Chest , vol.99 , pp. 1519-1520
    • Rubio, P.A.1    Al-Bassam, M.2
  • 10
    • 0032514609 scopus 로고    scopus 로고
    • Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads
    • Epstein AE, Kay GN, Plumb VJ, et al. Gross and microscopic pathological changes associated with nonthoracotomy implantable defibrillator leads. Circulation 1998; 98: 1517-1524. (Pubitemid 28481668)
    • (1998) Circulation , vol.98 , Issue.15 , pp. 1517-1524
    • Epstein, A.E.1    Kay, G.N.2    Plumb, V.J.3    Dailey, S.M.4    Anderson, P.G.5
  • 11
    • 0034022524 scopus 로고    scopus 로고
    • Pacemaker lead related tricuspid stenosis: A report of two cases
    • Heaven D, Henein M, Sutton R:, Pacemaker lead related tricuspid valve stenosis: A report of two cases. Heart 2000; 83: 351-352. (Pubitemid 30313343)
    • (2000) Heart , vol.83 , Issue.3 , pp. 351-352
    • Heaven, D.J.1    Henein, M.Y.2    Sutton, R.3
  • 12
    • 25644431964 scopus 로고    scopus 로고
    • Tricuspid valve perforation by permanet pacemaker lead: A case report
    • DOI 10.1177/000331970505600514
    • Erdinler I, Okmen E, Turek O, et al. Tricuspid valve perforation by permanent pacemaker lead-A case report. Angiology 2005; 56: 619-621. (Pubitemid 41383316)
    • (2005) Angiology , vol.56 , Issue.5 , pp. 619-621
    • Erdinler, I.1    Okmen, E.2    Turek, O.3    Yapici, F.4    Ozler, A.5    Cam, N.6    Ulufer, T.7
  • 13
    • 80053381658 scopus 로고    scopus 로고
    • Severe tricuspid valve regurgitation due to perforation by permanent pacemaker lead
    • Wen-Zong L, Liang M:, Severe tricuspid valve regurgitation due to perforation by permanent pacemaker lead. J Card Surg 2011; 26: 555-556.
    • (2011) J Card Surg , vol.26 , pp. 555-556
    • Wen-Zong, L.1    Liang, M.2
  • 14
    • 0015380386 scopus 로고
    • Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode
    • et al:.
    • Becker AE, Becker MJ, Claudon DG, et al. Surface thrombosis and fibrous encapsulation of intravenous pacemaker catheter electrode. Circulation 1972; 46: 409-412.
    • (1972) Circulation , vol.46 , pp. 409-412
    • Becker, A.E.1    Becker, M.J.2    Claudon, D.G.3
  • 15
    • 0014548321 scopus 로고
    • Adhesions of pacing catheter to tricuspid valve: Adhesive endocarditis
    • Friedberg HD, D'Cunha GF:, Adhesions of pacing catheter to tricuspid valve: Adhesive endocarditis. Thorax 1969; 24: 498-499.
    • (1969) Thorax , vol.24 , pp. 498-499
    • Friedberg, H.D.1    D'Cunha, G.2
  • 16
    • 0015325802 scopus 로고
    • Cardiac pathology of transvenous pacemakers
    • Huang TY, Baba N:, Cardiac pathology of transvenous pacemakers. Am Heart J 1972; 83: 469-474.
    • (1972) Am Heart J , vol.83 , pp. 469-474
    • Huang, T.Y.1    Baba, N.2
  • 17
    • 0014497212 scopus 로고
    • Autopsy findings with permanent pervenous pacemakers
    • et al:.
    • Robboy SJ, Harthorne JW, Leinbach RC, et al. Autopsy findings with permanent pervenous pacemakers. Circulation 1969; 39: 495-501.
    • (1969) Circulation , vol.39 , pp. 495-501
    • Robboy, S.J.1    Harthorne, J.W.2    Leinbach, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.