메뉴 건너뛰기




Volumn 33, Issue 6, 1999, Pages 1671-1676

Pacemaker lead extraction with the laser sheath: Results of the pacing lead extraction with the excimer sheath (PLEXES) trial

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFICIAL HEART PACEMAKER; CONTROLLED STUDY; EXCIMER LASER; FEMALE; FIBROSIS; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSTHESIS MATERIAL; SURGICAL TECHNIQUE;

EID: 0033133418     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0735-1097(99)00074-1     Document Type: Article
Times cited : (398)

References (17)
  • 3
    • 0029120291 scopus 로고
    • The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leads
    • Stokes K, Chem B, Anderson J, McVenes TR, McClay C. The encapsulation of polyurethane-insulated transvenous cardiac pacemaker leads. Cardiovasc Pathol 1995;4:163-71.
    • (1995) Cardiovasc Pathol , vol.4 , pp. 163-171
    • Stokes, K.1    Chem, B.2    Anderson, J.3    McVenes, T.R.4    McClay, C.5
  • 4
    • 85060355547 scopus 로고    scopus 로고
    • Clinical results with excimer laser coronary angioplasty
    • Bittl JA. Clinical results with excimer laser coronary angioplasty. Semin Intervent Cardiol 1996;1:1-15.
    • (1996) Semin Intervent Cardiol , vol.1 , pp. 1-15
    • Bittl, J.A.1
  • 5
    • 0000422117 scopus 로고    scopus 로고
    • Extracting chronically implanted pacemaker leads using the spectranetics excimer laser: Initial clinical experience
    • Byrd CL. Extracting chronically implanted pacemaker leads using the spectranetics excimer laser: initial clinical experience (abstr). PACE Pacing Clin Electrophysiol 1996;19:567.
    • (1996) PACE Pacing Clin Electrophysiol , vol.19 , pp. 567
    • Byrd, C.L.1
  • 7
    • 0026492336 scopus 로고
    • Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline
    • Gijsbers GH, van den Broecke DG, Sprangers RL, van Gamert MJ. Effect of force on ablation depth for a XeCl excimer laser beam delivered by an optical fiber in contact with arterial tissue under saline. Lasers Surg Med 1992;12:576-84.
    • (1992) Lasers Surg Med , vol.12 , pp. 576-584
    • Gijsbers, G.H.1    Van Den Broecke, D.G.2    Sprangers, R.L.3    Van Gamert, M.J.4
  • 9
    • 0030005039 scopus 로고    scopus 로고
    • Excimer laser induced bubble dimensions, theory and implications for laser angioplasty
    • van Leeuwen TG, Jansen ED, Welch AJ, Borst C. Excimer laser induced bubble dimensions, theory and implications for laser angioplasty. Lasers Surg Med 1996;18:381-90.
    • (1996) Lasers Surg Med , vol.18 , pp. 381-390
    • Van Leeuwen, T.G.1    Jansen, E.D.2    Welch, A.J.3    Borst, C.4
  • 11
    • 0031983656 scopus 로고    scopus 로고
    • Large laser sheaths for pacing and defibrillator lead removal
    • Reiser C, Taylor K, Lippincott R. Large laser sheaths for pacing and defibrillator lead removal. Lasers Surg Med 1998;22:42-5.
    • (1998) Lasers Surg Med , vol.22 , pp. 42-45
    • Reiser, C.1    Taylor, K.2    Lippincott, R.3
  • 13
    • 0026800758 scopus 로고
    • Lead extraction - Indications and techniques
    • Byrd CL, Schwartz SJ, Hedin N. Lead extraction - indications and techniques. Cardiol Clin 1992;10:735-48.
    • (1992) Cardiol Clin , vol.10 , pp. 735-748
    • Byrd, C.L.1    Schwartz, S.J.2    Hedin, N.3
  • 14
    • 0026060037 scopus 로고
    • Extraction of implanted transvenous pacing leads: A review of a persistent clinical problem
    • Myers MR, Parsonnet V, Bernstein AD. Extraction of implanted transvenous pacing leads: a review of a persistent clinical problem. Am Heart J 1991;121:881-8.
    • (1991) Am Heart J , vol.121 , pp. 881-888
    • Myers, M.R.1    Parsonnet, V.2    Bernstein, A.D.3
  • 15
    • 0029990449 scopus 로고    scopus 로고
    • Extraction of the Telectronics Accufix 330-801 atrial lead: The Mayo Clinic experience
    • Lloyd MA, Hayes DL, Holmes DR Jr, et al. Extraction of the Telectronics Accufix 330-801 atrial lead: the Mayo Clinic experience. Mayo Clinic Proc 1996;71:230-4.
    • (1996) Mayo Clinic Proc , vol.71 , pp. 230-234
    • Lloyd, M.A.1    Hayes, D.L.2    Holmes Jr., D.R.3
  • 16
    • 0000769837 scopus 로고    scopus 로고
    • Predictors of life threatening and major intravascular extraction complications with an Accufix atrial J lead
    • Love CJ, Brinker J, Rozkovec A, et al. Predictors of life threatening and major intravascular extraction complications with an Accufix atrial J lead (abstr). PACE Pacing Clin Electrophysiol 1996;19:577.
    • (1996) PACE Pacing Clin Electrophysiol , vol.19 , pp. 577
    • Love, C.J.1    Brinker, J.2    Rozkovec, A.3
  • 17
    • 33847510387 scopus 로고    scopus 로고
    • Pacemaker lead extraction: Mono-center comparison of lead removal via the implantation vein or via the femoral vein
    • Jarwe M, Klug D, LeFranc P, Lacrois D, Kouakam C, Kacet S. Pacemaker lead extraction: mono-center comparison of lead removal via the implantation vein or via the femoral vein (abstr). PACE Pacing Clin Electrophysiol 1997;20:1110.
    • (1997) PACE Pacing Clin Electrophysiol , vol.20 , pp. 1110
    • Jarwe, M.1    Klug, D.2    LeFranc, P.3    Lacrois, D.4    Kouakam, C.5    Kacet, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.