-
1
-
-
85027943026
-
Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial
-
PID: 26618259, [Epub ahead of print]
-
Gjelvold B, Chrcanovic BR, Korduner EK, Collin-Bagewitz I, Kisch J (2015) Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial. J Prosthodont. doi:10.1111/jopr.12410 [Epub ahead of print]
-
(2015)
J Prosthodont
-
-
Gjelvold, B.1
Chrcanovic, B.R.2
Korduner, E.K.3
Collin-Bagewitz, I.4
Kisch, J.5
-
3
-
-
84933678682
-
Intraoral digital impression technique: a review
-
PID: 25220390
-
Ting-Shu S, Jian S (2015) Intraoral digital impression technique: a review. J Prosthodont 24:313–321
-
(2015)
J Prosthodont
, vol.24
, pp. 313-321
-
-
Ting-Shu, S.1
Jian, S.2
-
5
-
-
84887012839
-
An evaluation of student and clinician perception of digital and conventional implant impressions
-
PID: 23998623
-
Lee SJ, Macarthur RX 4th, Gallucci GO (2013) An evaluation of student and clinician perception of digital and conventional implant impressions. J Prosthet Dent 110(5):420–423
-
(2013)
J Prosthet Dent
, vol.110
, Issue.5
, pp. 420-423
-
-
Lee, S.J.1
Macarthur, R.X.2
Gallucci, G.O.3
-
6
-
-
84893205192
-
Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes
-
PID: 24479892
-
Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 14:10–17
-
(2014)
BMC Oral Health
, vol.14
, pp. 10-17
-
-
Yuzbasioglu, E.1
Kurt, H.2
Turunc, R.3
Bilir, H.4
-
7
-
-
0025684903
-
Gingival margins for crowns: a review and discussion. Part II: discrepancies and configurations
-
PID: 2079668
-
Hunter AJ, Hunter AR (1990) Gingival margins for crowns: a review and discussion. Part II: discrepancies and configurations. J Prosthet Dent 64:636–642
-
(1990)
J Prosthet Dent
, vol.64
, pp. 636-642
-
-
Hunter, A.J.1
Hunter, A.R.2
-
8
-
-
0027620312
-
The fit of Procera titanium crowns. An in vitro and clinical study
-
PID: 8342403
-
Karlsson S (1993) The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 51:129–134
-
(1993)
Acta Odontol Scand
, vol.51
, pp. 129-134
-
-
Karlsson, S.1
-
9
-
-
84888393765
-
Marginal adaptation of ceramic crowns: a systematic review
-
PID: 24120071
-
Contrepois M, Soenen A, Bartala M, Laviole O (2013) Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 110:447–454
-
(2013)
J Prosthet Dent
, vol.110
, pp. 447-454
-
-
Contrepois, M.1
Soenen, A.2
Bartala, M.3
Laviole, O.4
-
10
-
-
84909946382
-
A systematic review of CAD/CAM fit restoration evaluations
-
PID: 24952991
-
Boitelle P, Mawussi B, Tapie L, Fromentin O (2014) A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil 41:853–874
-
(2014)
J Oral Rehabil
, vol.41
, pp. 853-874
-
-
Boitelle, P.1
Mawussi, B.2
Tapie, L.3
Fromentin, O.4
-
11
-
-
43449084359
-
Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
-
PID: 18471247
-
Wettstein F, Sailer I, Roos M, Hämmerle CH (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116(3):272–279
-
(2008)
Eur J Oral Sci
, vol.116
, Issue.3
, pp. 272-279
-
-
Wettstein, F.1
Sailer, I.2
Roos, M.3
Hämmerle, C.H.4
-
12
-
-
84881612097
-
Accuracy of digital and conventional impression techniques and workflow
-
PID: 23086333
-
Seelbach P, Brueckel C, Wostmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17:1759–1764
-
(2013)
Clin Oral Investig
, vol.17
, pp. 1759-1764
-
-
Seelbach, P.1
Brueckel, C.2
Wostmann, B.3
-
13
-
-
84894547254
-
Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
-
PID: 23716064
-
Almeida e Silva JS, Erdelt K, Edelhoff D, Araújo É, Stimmelmayr M, Vieira LC, Guth J (2014) Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18:515–523
-
(2014)
Clin Oral Investig
, vol.18
, pp. 515-523
-
-
Almeida e Silva, J.S.1
Erdelt, K.2
Edelhoff, D.3
Araújo, É.4
Stimmelmayr, M.5
Vieira, L.C.6
Guth, J.7
-
14
-
-
84897026100
-
Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study
-
PID: 24522150
-
Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Güth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study. Dent Mater 30(4):400–407
-
(2014)
Dent Mater
, vol.30
, Issue.4
, pp. 400-407
-
-
Keul, C.1
Stawarczyk, B.2
Erdelt, K.J.3
Beuer, F.4
Edelhoff, D.5
Güth, J.F.6
-
15
-
-
84902469715
-
Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study
-
PID: 24111810
-
Tidehag P, Ottosson K, Sjögren G (2014) Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study. Oper Dent 39(3):308–316
-
(2014)
Oper Dent
, vol.39
, Issue.3
, pp. 308-316
-
-
Tidehag, P.1
Ottosson, K.2
Sjögren, G.3
-
16
-
-
84942552925
-
Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners
-
PID: 26100929
-
Abdel-Azim T, Rogers K, Elathamna E, Zandinejad A, Metz M, Morton D (2015) Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners. J Prosthet Dent 114(4):554–559
-
(2015)
J Prosthet Dent
, vol.114
, Issue.4
, pp. 554-559
-
-
Abdel-Azim, T.1
Rogers, K.2
Elathamna, E.3
Zandinejad, A.4
Metz, M.5
Morton, D.6
-
17
-
-
84959131549
-
Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions
-
PID: 26121970, [Epub ahead of print]
-
Ueda K, Beuer F, Stimmelmayr M, Erdelt K, Keul C, Güth F (2015) Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions. Clin Oral Investig. doi:10.1007/s00784-015-1513-5 [Epub ahead of print]
-
(2015)
Clin Oral Investig
-
-
Ueda, K.1
Beuer, F.2
Stimmelmayr, M.3
Erdelt, K.4
Keul, C.5
Güth, F.6
-
18
-
-
77957280346
-
Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
-
PID: 20381576
-
Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J (2010) Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38:553–559
-
(2010)
J Dent
, vol.38
, pp. 553-559
-
-
Syrek, A.1
Reich, G.2
Ranftl, D.3
Klein, C.4
Cerny, B.5
Brodesser, J.6
-
19
-
-
84888638427
-
The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems
-
PID: 23371756
-
Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems. Clin Oral Investig 17(9):2119–2125
-
(2013)
Clin Oral Investig
, vol.17
, Issue.9
, pp. 2119-2125
-
-
Brawek, P.K.1
Wolfart, S.2
Endres, L.3
Kirsten, A.4
Reich, S.5
-
20
-
-
84906568692
-
Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions
-
PID: 25010876
-
Tamim H, Skjerven H, Ekfeldt A, Rønold HJ (2014) Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions. Int J Prosthodont 27(4):331–337
-
(2014)
Int J Prosthodont
, vol.27
, Issue.4
, pp. 331-337
-
-
Tamim, H.1
Skjerven, H.2
Ekfeldt, A.3
Rønold, H.J.4
-
21
-
-
84951726914
-
Veneered anatomically designed zirconia FDPs resulting from digital intraoral scans: preliminary results of a prospective clinical study
-
PID: 26523348
-
Selz CF, Bogler J, Vach K, Strub JR, Guess PC (2015) Veneered anatomically designed zirconia FDPs resulting from digital intraoral scans: preliminary results of a prospective clinical study. J Dent 43(12):1428–1435
-
(2015)
J Dent
, vol.43
, Issue.12
, pp. 1428-1435
-
-
Selz, C.F.1
Bogler, J.2
Vach, K.3
Strub, J.R.4
Guess, P.C.5
-
23
-
-
77958090670
-
Fit of zirconia fixed partial denture: a systematic review
-
PID: 20557435
-
Abduo J, Lyons K, Swain M (2010) Fit of zirconia fixed partial denture: a systematic review. J Oral Rehabil 37:866–876
-
(2010)
J Oral Rehabil
, vol.37
, pp. 866-876
-
-
Abduo, J.1
Lyons, K.2
Swain, M.3
-
24
-
-
38149014578
-
Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method
-
PID: 18197844
-
Laurent M, Scheer P, Dejou J, Laborde G (2008) Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method. J Oral Rehabil 35:116–122
-
(2008)
J Oral Rehabil
, vol.35
, pp. 116-122
-
-
Laurent, M.1
Scheer, P.2
Dejou, J.3
Laborde, G.4
-
25
-
-
0015209415
-
The estimation of cement film thickness by an in vivo technique
-
PID: 5283545
-
McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131:107–111
-
(1971)
Br Dent J
, vol.131
, pp. 107-111
-
-
McLean, J.W.1
von Fraunhofer, J.A.2
-
26
-
-
0022139299
-
The fit of metal-ceramic crowns, a clinical study
-
PID: 3912241
-
Fransson B, Oilo G, Gjeitanger R (1985) The fit of metal-ceramic crowns, a clinical study. Dent Mater 1:197–199
-
(1985)
Dent Mater
, vol.1
, pp. 197-199
-
-
Fransson, B.1
Oilo, G.2
Gjeitanger, R.3
-
27
-
-
79960137183
-
Measurement of cement thickness under lithium disilicate crowns using an impression material technique
-
PID: 20461424
-
Reich S, Uhlen S, Gozdowski S, Lohbauer U (2011) Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Investig 15:521–526
-
(2011)
Clin Oral Investig
, vol.15
, pp. 521-526
-
-
Reich, S.1
Uhlen, S.2
Gozdowski, S.3
Lohbauer, U.4
-
28
-
-
84959130155
-
Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial
-
PID: 26070435, [Epub ahead of print]
-
Ahrberg D, Lauer CL, Ahrberg M, Weigl P (2015) Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial. Clin Oral Investig. doi:10.1007/s00784-015-1504-6 [Epub ahead of print]
-
(2015)
Clin Oral Investig
-
-
Ahrberg, D.1
Lauer, C.L.2
Ahrberg, M.3
Weigl, P.4
-
29
-
-
84942986932
-
Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients
-
PID: 25693497
-
Boeddinghaus M, Breloer ES, Rehmann P, Wöstmann B (2015) Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 19:2027–2034
-
(2015)
Clin Oral Investig
, vol.19
, pp. 2027-2034
-
-
Boeddinghaus, M.1
Breloer, E.S.2
Rehmann, P.3
Wöstmann, B.4
-
30
-
-
84922798743
-
Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology
-
PID: 25527248
-
Pradíes G, Zarauz C, Valverde A, Ferreiroa A, Martínez-Rus F (2015) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent 43(2):201–208
-
(2015)
J Dent
, vol.43
, Issue.2
, pp. 201-208
-
-
Pradíes, G.1
Zarauz, C.2
Valverde, A.3
Ferreiroa, A.4
Martínez-Rus, F.5
-
31
-
-
84941361665
-
Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
-
PID: 26362778, [Epub ahead of print]
-
Zarauz C, Valverde A, Martinez-Rus F, Hassan B, Pradies G (2015) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions. Clin Oral Investig. doi:10.1007/s00784-015-1590-5 [Epub ahead of print]
-
(2015)
Clin Oral Investig
-
-
Zarauz, C.1
Valverde, A.2
Martinez-Rus, F.3
Hassan, B.4
Pradies, G.5
-
32
-
-
84879182149
-
Influence of the scanning strategies on the accuracy of digital intraoral scanning systems
-
PID: 23641661
-
Ender A, Mehl A (2013) Influence of the scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 16:11–21
-
(2013)
Int J Comput Dent
, vol.16
, pp. 11-21
-
-
Ender, A.1
Mehl, A.2
-
33
-
-
84864675575
-
Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings
-
PID: 22864213
-
Rinke S, Fornefett D, Gersdorff N, Lange K, Roediger M (2012) Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings. Dent Mater J 31(4):601–609
-
(2012)
Dent Mater J
, vol.31
, Issue.4
, pp. 601-609
-
-
Rinke, S.1
Fornefett, D.2
Gersdorff, N.3
Lange, K.4
Roediger, M.5
-
34
-
-
84864717827
-
Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns
-
PID: 21165185
-
Pak HS, Han JS, Lee JB, Kim SH, Yang JH (2010) Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns. J Adv Prosthodont 2:33–38
-
(2010)
J Adv Prosthodont
, vol.2
, pp. 33-38
-
-
Pak, H.S.1
Han, J.S.2
Lee, J.B.3
Kim, S.H.4
Yang, J.H.5
-
35
-
-
84944175820
-
Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: an in vitro study
-
PID: 26211702
-
Su TS, Sun J (2015) Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: an in vitro study. J Prosthodont Res 59:236–242
-
(2015)
J Prosthodont Res
, vol.59
, pp. 236-242
-
-
Su, T.S.1
Sun, J.2
|