메뉴 건너뛰기




Volumn 21, Issue 2, 2017, Pages 579-587

Fitting accuracy of zirconia single crowns produced via digital and conventional impressions—a clinical comparative study

Author keywords

Cad Cam; Digital impression; Fitting accuracy; Replica technique; Zirconia crown

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; POLYVINYL DERIVATIVE; SILOXANE; VINYL POLYSILOXANE; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 84980030902     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-016-1924-y     Document Type: Article
Times cited : (63)

References (35)
  • 1
    • 85027943026 scopus 로고    scopus 로고
    • Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial
    • PID: 26618259, [Epub ahead of print]
    • Gjelvold B, Chrcanovic BR, Korduner EK, Collin-Bagewitz I, Kisch J (2015) Intraoral digital impression technique compared to conventional impression technique. A randomized clinical trial. J Prosthodont. doi:10.1111/jopr.12410 [Epub ahead of print]
    • (2015) J Prosthodont
    • Gjelvold, B.1    Chrcanovic, B.R.2    Korduner, E.K.3    Collin-Bagewitz, I.4    Kisch, J.5
  • 3
    • 84933678682 scopus 로고    scopus 로고
    • Intraoral digital impression technique: a review
    • PID: 25220390
    • Ting-Shu S, Jian S (2015) Intraoral digital impression technique: a review. J Prosthodont 24:313–321
    • (2015) J Prosthodont , vol.24 , pp. 313-321
    • Ting-Shu, S.1    Jian, S.2
  • 5
    • 84887012839 scopus 로고    scopus 로고
    • An evaluation of student and clinician perception of digital and conventional implant impressions
    • PID: 23998623
    • Lee SJ, Macarthur RX 4th, Gallucci GO (2013) An evaluation of student and clinician perception of digital and conventional implant impressions. J Prosthet Dent 110(5):420–423
    • (2013) J Prosthet Dent , vol.110 , Issue.5 , pp. 420-423
    • Lee, S.J.1    Macarthur, R.X.2    Gallucci, G.O.3
  • 6
    • 84893205192 scopus 로고    scopus 로고
    • Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes
    • PID: 24479892
    • Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health 14:10–17
    • (2014) BMC Oral Health , vol.14 , pp. 10-17
    • Yuzbasioglu, E.1    Kurt, H.2    Turunc, R.3    Bilir, H.4
  • 7
    • 0025684903 scopus 로고
    • Gingival margins for crowns: a review and discussion. Part II: discrepancies and configurations
    • PID: 2079668
    • Hunter AJ, Hunter AR (1990) Gingival margins for crowns: a review and discussion. Part II: discrepancies and configurations. J Prosthet Dent 64:636–642
    • (1990) J Prosthet Dent , vol.64 , pp. 636-642
    • Hunter, A.J.1    Hunter, A.R.2
  • 8
    • 0027620312 scopus 로고
    • The fit of Procera titanium crowns. An in vitro and clinical study
    • PID: 8342403
    • Karlsson S (1993) The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 51:129–134
    • (1993) Acta Odontol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 9
    • 84888393765 scopus 로고    scopus 로고
    • Marginal adaptation of ceramic crowns: a systematic review
    • PID: 24120071
    • Contrepois M, Soenen A, Bartala M, Laviole O (2013) Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 110:447–454
    • (2013) J Prosthet Dent , vol.110 , pp. 447-454
    • Contrepois, M.1    Soenen, A.2    Bartala, M.3    Laviole, O.4
  • 10
    • 84909946382 scopus 로고    scopus 로고
    • A systematic review of CAD/CAM fit restoration evaluations
    • PID: 24952991
    • Boitelle P, Mawussi B, Tapie L, Fromentin O (2014) A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil 41:853–874
    • (2014) J Oral Rehabil , vol.41 , pp. 853-874
    • Boitelle, P.1    Mawussi, B.2    Tapie, L.3    Fromentin, O.4
  • 11
    • 43449084359 scopus 로고    scopus 로고
    • Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    • PID: 18471247
    • Wettstein F, Sailer I, Roos M, Hämmerle CH (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116(3):272–279
    • (2008) Eur J Oral Sci , vol.116 , Issue.3 , pp. 272-279
    • Wettstein, F.1    Sailer, I.2    Roos, M.3    Hämmerle, C.H.4
  • 12
    • 84881612097 scopus 로고    scopus 로고
    • Accuracy of digital and conventional impression techniques and workflow
    • PID: 23086333
    • Seelbach P, Brueckel C, Wostmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17:1759–1764
    • (2013) Clin Oral Investig , vol.17 , pp. 1759-1764
    • Seelbach, P.1    Brueckel, C.2    Wostmann, B.3
  • 13
    • 84894547254 scopus 로고    scopus 로고
    • Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    • PID: 23716064
    • Almeida e Silva JS, Erdelt K, Edelhoff D, Araújo É, Stimmelmayr M, Vieira LC, Guth J (2014) Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18:515–523
    • (2014) Clin Oral Investig , vol.18 , pp. 515-523
    • Almeida e Silva, J.S.1    Erdelt, K.2    Edelhoff, D.3    Araújo, É.4    Stimmelmayr, M.5    Vieira, L.C.6    Guth, J.7
  • 14
    • 84897026100 scopus 로고    scopus 로고
    • Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study
    • PID: 24522150
    • Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Güth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study. Dent Mater 30(4):400–407
    • (2014) Dent Mater , vol.30 , Issue.4 , pp. 400-407
    • Keul, C.1    Stawarczyk, B.2    Erdelt, K.J.3    Beuer, F.4    Edelhoff, D.5    Güth, J.F.6
  • 15
    • 84902469715 scopus 로고    scopus 로고
    • Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study
    • PID: 24111810
    • Tidehag P, Ottosson K, Sjögren G (2014) Accuracy of ceramic restorations made using an in-office optical scanning technique: an in vitro study. Oper Dent 39(3):308–316
    • (2014) Oper Dent , vol.39 , Issue.3 , pp. 308-316
    • Tidehag, P.1    Ottosson, K.2    Sjögren, G.3
  • 16
    • 84942552925 scopus 로고    scopus 로고
    • Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners
    • PID: 26100929
    • Abdel-Azim T, Rogers K, Elathamna E, Zandinejad A, Metz M, Morton D (2015) Comparison of the marginal fit of lithium disilicate crowns fabricated with CAD/CAM technology by using conventional impressions and two intraoral digital scanners. J Prosthet Dent 114(4):554–559
    • (2015) J Prosthet Dent , vol.114 , Issue.4 , pp. 554-559
    • Abdel-Azim, T.1    Rogers, K.2    Elathamna, E.3    Zandinejad, A.4    Metz, M.5    Morton, D.6
  • 17
    • 84959131549 scopus 로고    scopus 로고
    • Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions
    • PID: 26121970, [Epub ahead of print]
    • Ueda K, Beuer F, Stimmelmayr M, Erdelt K, Keul C, Güth F (2015) Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions. Clin Oral Investig. doi:10.1007/s00784-015-1513-5 [Epub ahead of print]
    • (2015) Clin Oral Investig
    • Ueda, K.1    Beuer, F.2    Stimmelmayr, M.3    Erdelt, K.4    Keul, C.5    Güth, F.6
  • 18
    • 77957280346 scopus 로고    scopus 로고
    • Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
    • PID: 20381576
    • Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J (2010) Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38:553–559
    • (2010) J Dent , vol.38 , pp. 553-559
    • Syrek, A.1    Reich, G.2    Ranftl, D.3    Klein, C.4    Cerny, B.5    Brodesser, J.6
  • 19
    • 84888638427 scopus 로고    scopus 로고
    • The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems
    • PID: 23371756
    • Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems. Clin Oral Investig 17(9):2119–2125
    • (2013) Clin Oral Investig , vol.17 , Issue.9 , pp. 2119-2125
    • Brawek, P.K.1    Wolfart, S.2    Endres, L.3    Kirsten, A.4    Reich, S.5
  • 20
    • 84906568692 scopus 로고    scopus 로고
    • Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions
    • PID: 25010876
    • Tamim H, Skjerven H, Ekfeldt A, Rønold HJ (2014) Clinical evaluation of CAD/CAM metal-ceramic posterior crowns fabricated from intraoral digital impressions. Int J Prosthodont 27(4):331–337
    • (2014) Int J Prosthodont , vol.27 , Issue.4 , pp. 331-337
    • Tamim, H.1    Skjerven, H.2    Ekfeldt, A.3    Rønold, H.J.4
  • 21
    • 84951726914 scopus 로고    scopus 로고
    • Veneered anatomically designed zirconia FDPs resulting from digital intraoral scans: preliminary results of a prospective clinical study
    • PID: 26523348
    • Selz CF, Bogler J, Vach K, Strub JR, Guess PC (2015) Veneered anatomically designed zirconia FDPs resulting from digital intraoral scans: preliminary results of a prospective clinical study. J Dent 43(12):1428–1435
    • (2015) J Dent , vol.43 , Issue.12 , pp. 1428-1435
    • Selz, C.F.1    Bogler, J.2    Vach, K.3    Strub, J.R.4    Guess, P.C.5
  • 23
    • 77958090670 scopus 로고    scopus 로고
    • Fit of zirconia fixed partial denture: a systematic review
    • PID: 20557435
    • Abduo J, Lyons K, Swain M (2010) Fit of zirconia fixed partial denture: a systematic review. J Oral Rehabil 37:866–876
    • (2010) J Oral Rehabil , vol.37 , pp. 866-876
    • Abduo, J.1    Lyons, K.2    Swain, M.3
  • 24
    • 38149014578 scopus 로고    scopus 로고
    • Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method
    • PID: 18197844
    • Laurent M, Scheer P, Dejou J, Laborde G (2008) Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method. J Oral Rehabil 35:116–122
    • (2008) J Oral Rehabil , vol.35 , pp. 116-122
    • Laurent, M.1    Scheer, P.2    Dejou, J.3    Laborde, G.4
  • 25
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • PID: 5283545
    • McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131:107–111
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    von Fraunhofer, J.A.2
  • 26
    • 0022139299 scopus 로고
    • The fit of metal-ceramic crowns, a clinical study
    • PID: 3912241
    • Fransson B, Oilo G, Gjeitanger R (1985) The fit of metal-ceramic crowns, a clinical study. Dent Mater 1:197–199
    • (1985) Dent Mater , vol.1 , pp. 197-199
    • Fransson, B.1    Oilo, G.2    Gjeitanger, R.3
  • 27
    • 79960137183 scopus 로고    scopus 로고
    • Measurement of cement thickness under lithium disilicate crowns using an impression material technique
    • PID: 20461424
    • Reich S, Uhlen S, Gozdowski S, Lohbauer U (2011) Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Investig 15:521–526
    • (2011) Clin Oral Investig , vol.15 , pp. 521-526
    • Reich, S.1    Uhlen, S.2    Gozdowski, S.3    Lohbauer, U.4
  • 28
    • 84959130155 scopus 로고    scopus 로고
    • Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial
    • PID: 26070435, [Epub ahead of print]
    • Ahrberg D, Lauer CL, Ahrberg M, Weigl P (2015) Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial. Clin Oral Investig. doi:10.1007/s00784-015-1504-6 [Epub ahead of print]
    • (2015) Clin Oral Investig
    • Ahrberg, D.1    Lauer, C.L.2    Ahrberg, M.3    Weigl, P.4
  • 29
    • 84942986932 scopus 로고    scopus 로고
    • Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients
    • PID: 25693497
    • Boeddinghaus M, Breloer ES, Rehmann P, Wöstmann B (2015) Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 19:2027–2034
    • (2015) Clin Oral Investig , vol.19 , pp. 2027-2034
    • Boeddinghaus, M.1    Breloer, E.S.2    Rehmann, P.3    Wöstmann, B.4
  • 30
    • 84922798743 scopus 로고    scopus 로고
    • Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology
    • PID: 25527248
    • Pradíes G, Zarauz C, Valverde A, Ferreiroa A, Martínez-Rus F (2015) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent 43(2):201–208
    • (2015) J Dent , vol.43 , Issue.2 , pp. 201-208
    • Pradíes, G.1    Zarauz, C.2    Valverde, A.3    Ferreiroa, A.4    Martínez-Rus, F.5
  • 31
    • 84941361665 scopus 로고    scopus 로고
    • Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions
    • PID: 26362778, [Epub ahead of print]
    • Zarauz C, Valverde A, Martinez-Rus F, Hassan B, Pradies G (2015) Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions. Clin Oral Investig. doi:10.1007/s00784-015-1590-5 [Epub ahead of print]
    • (2015) Clin Oral Investig
    • Zarauz, C.1    Valverde, A.2    Martinez-Rus, F.3    Hassan, B.4    Pradies, G.5
  • 32
    • 84879182149 scopus 로고    scopus 로고
    • Influence of the scanning strategies on the accuracy of digital intraoral scanning systems
    • PID: 23641661
    • Ender A, Mehl A (2013) Influence of the scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 16:11–21
    • (2013) Int J Comput Dent , vol.16 , pp. 11-21
    • Ender, A.1    Mehl, A.2
  • 33
    • 84864675575 scopus 로고    scopus 로고
    • Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings
    • PID: 22864213
    • Rinke S, Fornefett D, Gersdorff N, Lange K, Roediger M (2012) Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings. Dent Mater J 31(4):601–609
    • (2012) Dent Mater J , vol.31 , Issue.4 , pp. 601-609
    • Rinke, S.1    Fornefett, D.2    Gersdorff, N.3    Lange, K.4    Roediger, M.5
  • 34
    • 84864717827 scopus 로고    scopus 로고
    • Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns
    • PID: 21165185
    • Pak HS, Han JS, Lee JB, Kim SH, Yang JH (2010) Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns. J Adv Prosthodont 2:33–38
    • (2010) J Adv Prosthodont , vol.2 , pp. 33-38
    • Pak, H.S.1    Han, J.S.2    Lee, J.B.3    Kim, S.H.4    Yang, J.H.5
  • 35
    • 84944175820 scopus 로고    scopus 로고
    • Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: an in vitro study
    • PID: 26211702
    • Su TS, Sun J (2015) Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: an in vitro study. J Prosthodont Res 59:236–242
    • (2015) J Prosthodont Res , vol.59 , pp. 236-242
    • Su, T.S.1    Sun, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.