메뉴 건너뛰기




Volumn 20, Issue 4, 2016, Pages 799-806

Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions

Author keywords

All ceramic crowns; CAD CAM; Dental impression materials: silicone; Digital impression; Intraoral scanner; Marginal fit; Replica technique

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; DENTAL PORCELAIN; SILICONE DERIVATIVE;

EID: 84941361665     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-015-1590-5     Document Type: Article
Times cited : (92)

References (29)
  • 1
    • 78651247534 scopus 로고    scopus 로고
    • From porcelain-fused-to-metal to zirconia: clinical and experimental considerations
    • PID: 21094996
    • Zarone F, Russo S, Sorrentino R (2011) From porcelain-fused-to-metal to zirconia: clinical and experimental considerations. Dent Mater 27:83–96
    • (2011) Dent Mater , vol.27 , pp. 83-96
    • Zarone, F.1    Russo, S.2    Sorrentino, R.3
  • 2
    • 0037982925 scopus 로고    scopus 로고
    • Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology
    • PID: 12680050
    • Luthardt R, Weber A, Rudolph H, Schöne C, Quaas S, Walter M (2002) Design and production of dental prosthetic restorations: basic research on dental CAD/CAM technology. Int J Comput Dent 5:165–176
    • (2002) Int J Comput Dent , vol.5 , pp. 165-176
    • Luthardt, R.1    Weber, A.2    Rudolph, H.3    Schöne, C.4    Quaas, S.5    Walter, M.6
  • 3
    • 33750170022 scopus 로고    scopus 로고
    • Accuracy of dental digitizers
    • PID: 17069074
    • Vlaar ST, Van der Zel JM (2006) Accuracy of dental digitizers. Int Dent J 56:301–309
    • (2006) Int Dent J , vol.56 , pp. 301-309
    • Vlaar, S.T.1    Van der Zel, J.M.2
  • 4
    • 63449088303 scopus 로고    scopus 로고
    • A review of dental CAD/CAM: current status and future perspectives from 20 years of experience
    • PID: 19280967
    • Miyazaki T, Hotta Y, Kunii J, Kuriyama S, Tamaki Y (2009) A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 28:44–56
    • (2009) Dent Mater J , vol.28 , pp. 44-56
    • Miyazaki, T.1    Hotta, Y.2    Kunii, J.3    Kuriyama, S.4    Tamaki, Y.5
  • 5
    • 33749241323 scopus 로고    scopus 로고
    • The evolution of the CEREC system
    • Mörmann WH (2006) The evolution of the CEREC system. J Am Dent Assoc 137:7–13
    • (2006) J Am Dent Assoc , vol.137 , pp. 7-13
    • Mörmann, W.H.1
  • 6
    • 0141721834 scopus 로고    scopus 로고
    • Comparison of the marginal fit of Procera AllCeram crowns with two finish lines
    • PID: 12854783
    • Suarez MJ, Gonzalez P, Pradíes G, Salido MP (2003) Comparison of the marginal fit of Procera AllCeram crowns with two finish lines. Int J Prosthodont 16:229–232
    • (2003) Int J Prosthodont , vol.16 , pp. 229-232
    • Suarez, M.J.1    Gonzalez, P.2    Pradíes, G.3    Salido, M.P.4
  • 7
    • 36148962932 scopus 로고    scopus 로고
    • Current ceramic materials and systems with clinical recommendations: a systematic review
    • PID: 18021828
    • Conrad HJ, Seong W-J, Pesun IJ (2007) Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 98:389–404
    • (2007) J Prosthet Dent , vol.98 , pp. 389-404
    • Conrad, H.J.1    Seong, W.-J.2    Pesun, I.J.3
  • 8
    • 9944229063 scopus 로고    scopus 로고
    • Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature
    • PID: 15583562
    • Raigrodski AJ (2004) Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature. J Prosthet Dent 92:557–562
    • (2004) J Prosthet Dent , vol.92 , pp. 557-562
    • Raigrodski, A.J.1
  • 9
    • 77957280346 scopus 로고    scopus 로고
    • Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
    • PID: 20381576
    • Syrek A, Reich G, Ranftl D et al (2010) Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38:553–559
    • (2010) J Dent , vol.38 , pp. 553-559
    • Syrek, A.1    Reich, G.2    Ranftl, D.3
  • 10
    • 84879182149 scopus 로고    scopus 로고
    • Influence of scanning strategies on the accuracy of digital intraoral scanning systems
    • PID: 23641661
    • Ender A, Mehl A (2013) Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 16:11–21
    • (2013) Int J Comput Dent , vol.16 , pp. 11-21
    • Ender, A.1    Mehl, A.2
  • 11
    • 84864717827 scopus 로고    scopus 로고
    • Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns
    • PID: 21165185
    • Pak H-S, Han J-S, Lee J-B et al (2010) Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns. J Adv Prosthodont 2:33–38
    • (2010) J Adv Prosthodont , vol.2 , pp. 33-38
    • Pak, H.-S.1    Han, J.-S.2    Lee, J.-B.3
  • 12
    • 0026127801 scopus 로고
    • An investigation of dental luting cement solubility as a function of the marginal gap
    • PID: 2056466
    • Jacobs MS, Windeler AS (1991) An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 65:436–442
    • (1991) J Prosthet Dent , vol.65 , pp. 436-442
    • Jacobs, M.S.1    Windeler, A.S.2
  • 13
    • 79251493434 scopus 로고    scopus 로고
    • Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings
    • PID: 21262408
    • Martinez-Rus F, Suarez MJ, Rivera B, Pradíes G (2011) Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings. J Prosthet Dent 105:108–114
    • (2011) J Prosthet Dent , vol.105 , pp. 108-114
    • Martinez-Rus, F.1    Suarez, M.J.2    Rivera, B.3    Pradíes, G.4
  • 14
    • 0014891551 scopus 로고
    • Marginal fit of restorations and its relation to periodontal bone level. II. Crowns
    • PID: 5275036
    • Björn AL, Björn H, Grkovic B (1970) Marginal fit of restorations and its relation to periodontal bone level. II. Crowns. Odontol Revy 21:337–346
    • (1970) Odontol Revy , vol.21 , pp. 337-346
    • Björn, A.L.1    Björn, H.2    Grkovic, B.3
  • 15
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • PID: 5283545
    • McLean JW, Von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131:107–111
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    Von Fraunhofer, J.A.2
  • 16
    • 84881612097 scopus 로고    scopus 로고
    • Accuracy of digital and conventional impression techniques and workflow
    • PID: 23086333
    • Seelbach P, Brueckel C, Wöstmann B (2012) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17:1759–1764
    • (2012) Clin Oral Investig , vol.17 , pp. 1759-1764
    • Seelbach, P.1    Brueckel, C.2    Wöstmann, B.3
  • 17
    • 84876426016 scopus 로고    scopus 로고
    • Accuracy of digital models obtained by direct and indirect data capturing
    • PID: 22847854
    • Güth J-F, Keul C, Stimmelmayr M, Beuer F, Edelhoff D (2013) Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig 17:1201–1208
    • (2013) Clin Oral Investig , vol.17 , pp. 1201-1208
    • Güth, J.-F.1    Keul, C.2    Stimmelmayr, M.3    Beuer, F.4    Edelhoff, D.5
  • 18
    • 84894547254 scopus 로고    scopus 로고
    • Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    • Almeida E, Silva JS, Erdelt K, Edelhoff D et al (2014) Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18:515–523
    • (2014) Clin Oral Investig , vol.18 , pp. 515-523
    • Almeida, E.1    Silva, J.S.2    Erdelt, K.3    Edelhoff, D.4
  • 19
    • 84888638427 scopus 로고    scopus 로고
    • The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    • PID: 23371756
    • Brawek PK, Wolfart S, Endres L, Kristen A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems. Clin Oral Investig 17:2119–2125
    • (2013) Clin Oral Investig , vol.17 , pp. 2119-2125
    • Brawek, P.K.1    Wolfart, S.2    Endres, L.3    Kristen, A.4    Reich, S.5
  • 20
    • 0034305307 scopus 로고    scopus 로고
    • Clinical fit of Procera AllCeram crowns
    • PID: 11044849
    • Boening KW (2000) Clinical fit of Procera AllCeram crowns. J Prosthet Dent 84:419–424
    • (2000) J Prosthet Dent , vol.84 , pp. 419-424
    • Boening, K.W.1
  • 21
    • 84862751798 scopus 로고    scopus 로고
    • Internal fit of two all ceramic systems and metal ceramic crowns
    • PID: 22666843
    • Martins LM, Lorenzoni FC, De Melo AO et al (2012) Internal fit of two all ceramic systems and metal ceramic crowns. J Appl Oral Sci 20:235–240
    • (2012) J Appl Oral Sci , vol.20 , pp. 235-240
    • Martins, L.M.1    Lorenzoni, F.C.2    De Melo, A.O.3
  • 22
    • 33845346140 scopus 로고    scopus 로고
    • Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAM
    • PID: 16781043
    • Tsitrou EA, Northeast SE, Van Noort R (2007) Evaluation of the marginal fit of three margin designs of resin composite crowns using CAD/CAM. J Dent 35:68–73
    • (2007) J Dent , vol.35 , pp. 68-73
    • Tsitrou, E.A.1    Northeast, S.E.2    Van Noort, R.3
  • 23
    • 43449084359 scopus 로고    scopus 로고
    • Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    • PID: 18471247
    • Wettstein F, Sailer I, Roos M, Hämmerle CHF (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116:272–279
    • (2008) Eur J Oral Sci , vol.116 , pp. 272-279
    • Wettstein, F.1    Sailer, I.2    Roos, M.3    Hämmerle, C.H.F.4
  • 25
    • 0026862039 scopus 로고
    • Accuracy of one-step versus two-step putty wash addition silicone impression technique
    • PID: 1527737
    • Hung SH, Purk JH, Tira DE, Eick JD (1992) Accuracy of one-step versus two-step putty wash addition silicone impression technique. J Prosthet Dent 67:583–589
    • (1992) J Prosthet Dent , vol.67 , pp. 583-589
    • Hung, S.H.1    Purk, J.H.2    Tira, D.E.3    Eick, J.D.4
  • 26
    • 0032512145 scopus 로고    scopus 로고
    • The influence of the impression tray on the accuracy of impressions for crown and bridge work—an investigation and review
    • PID: 9885431
    • Carrotte PV, Johnson A, Winstanley RB (1998) The influence of the impression tray on the accuracy of impressions for crown and bridge work—an investigation and review. Br Dent J 185:580–585
    • (1998) Br Dent J , vol.185 , pp. 580-585
    • Carrotte, P.V.1    Johnson, A.2    Winstanley, R.B.3
  • 27
    • 85047690185 scopus 로고    scopus 로고
    • Dimensional accuracy of dental casts: influence of tray material, impression material, and time
    • PID: 12087547
    • Thongthammachat S, Moore BK, Barco MT et al (2002) Dimensional accuracy of dental casts: influence of tray material, impression material, and time. J Prosthodont 11:98–108
    • (2002) J Prosthodont , vol.11 , pp. 98-108
    • Thongthammachat, S.1    Moore, B.K.2    Barco, M.T.3
  • 28
    • 84857795655 scopus 로고    scopus 로고
    • Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD/CAM system
    • PID: 22050205
    • Souza ROA, Ozcan M, Pavanelli CA et al (2012) Marginal and internal discrepancies related to margin design of ceramic crowns fabricated by a CAD/CAM system. J Prosthodont 21:94–10034
    • (2012) J Prosthodont , vol.21 , pp. 94-10034
    • Souza, R.O.A.1    Ozcan, M.2    Pavanelli, C.A.3
  • 29
    • 0141721834 scopus 로고    scopus 로고
    • Comparison of the marginal fit of procera AllCeram crowns with two finish lines
    • PID: 12854783
    • Suárez MJ (2003) Comparison of the marginal fit of procera AllCeram crowns with two finish lines. Int J Prosthodont 16:229–232
    • (2003) Int J Prosthodont , vol.16 , pp. 229-232
    • Suárez, M.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.