Volumn 20, Issue 2, 2016, Pages 291-300

Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial

Author keywords

Computer aided design computer aided manufacturing (CAD CAM); Conventional impression; Digital impression; Intraoral scanner; Marginal gap; Zirconia ceramic

Indexed keywords

BIOMEDICAL AND DENTAL MATERIALS; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 84959130155     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-015-1504-6     Document Type: Article
Times cited : (124)

References (59)
  • 1
    • 46649093569 scopus 로고    scopus 로고
    • Will digital impressions eliminate the current problems with conventional impressions?
    • PID: 18520000
    • Christensen GJ (2008) Will digital impressions eliminate the current problems with conventional impressions? J Am Dent Assoc 139(6):761–763
    • (2008) J Am Dent Assoc , vol.139 , Issue.6 , pp. 761-763
    • Christensen, G.J.1
  • 2
    • 44249116685 scopus 로고    scopus 로고
    • Digital dentistry: an overview of recent developments for CAD/CAM generated restorations
    • PID: 18469768
    • Beuer F, Schweiger J, Edelhoff D (2008) Digital dentistry: an overview of recent developments for CAD/CAM generated restorations. Br Dent J 204(9):505–511
    • (2008) Br Dent J , vol.204 , Issue.9 , pp. 505-511
    • Beuer, F.1    Schweiger, J.2    Edelhoff, D.3
  • 3
    • 41249096458 scopus 로고    scopus 로고
    • The challenge to conventional impressions
    • PID: 18310740
    • Christensen GJ (2008) The challenge to conventional impressions. J Am Dent Assoc 139(3):347–349
    • (2008) J Am Dent Assoc , vol.139 , Issue.3 , pp. 347-349
    • Christensen, G.J.1
  • 4
    • 84893205192 scopus 로고    scopus 로고
    • Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes
    • PID: 24479892
    • Yuzbasioglu E, Kurt H, Turunc R, Bilir H (2014) Comparison of digital and conventional impression techniques: evaluation of patients’ perception, treatment comfort, effectiveness and clinical outcomes. BMC Oral Health. doi:10.1186/1472-6831-14-10
    • (2014) BMC Oral Health
    • Yuzbasioglu, E.1    Kurt, H.2    Turunc, R.3    Bilir, H.4
  • 5
    • 0034303196 scopus 로고    scopus 로고
    • Accuracy of casts generated from dual-arch impressions
    • PID: 11044846
    • Breeding LC, Dixon DL (2000) Accuracy of casts generated from dual-arch impressions. J Prosthet Dent 84(4):403–407
    • (2000) J Prosthet Dent , vol.84 , Issue.4 , pp. 403-407
    • Breeding, L.C.1    Dixon, D.L.2
  • 6
    • 5344236054 scopus 로고    scopus 로고
    • Distortion of disposable plastic stock trays when used with putty vinyl polysi- loxane impression materials
    • PID: 15507908
    • Cho GC, Chee WW (2004) Distortion of disposable plastic stock trays when used with putty vinyl polysi- loxane impression materials. J Prosthet Dent 92(4):354–358
    • (2004) J Prosthet Dent , vol.92 , Issue.4 , pp. 354-358
    • Cho, G.C.1    Chee, W.W.2
  • 7
    • 29144495734 scopus 로고    scopus 로고
    • Qualitative computer aided evaluation of dental impressions in vivo
    • PID: 16040117
    • Luthardt RG et al (2006) Qualitative computer aided evaluation of dental impressions in vivo. Dent Mater 22(1):69–76
    • (2006) Dent Mater , vol.22 , Issue.1 , pp. 69-76
    • Luthardt, R.G.1
  • 8
    • 48749096795 scopus 로고    scopus 로고
    • Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial
    • PID: 18717091
    • Luthardt RG, Walter MH, Weber A, Koch R, Rudolph H (2008) Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial. Int J Prosthodont 21(4):322–327
    • (2008) Int J Prosthodont , vol.21 , Issue.4 , pp. 322-327
    • Luthardt, R.G.1    Walter, M.H.2    Weber, A.3    Koch, R.4    Rudolph, H.5
  • 9
    • 36849057638 scopus 로고    scopus 로고
    • Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity
    • PID: 18069363
    • Balkenhol M, Ferger P, Wöstmann B (2007) Dimensional accuracy of 2-stage putty-wash impressions: influence of impression trays and viscosity. Int J Prosthodont 20(6):573–575
    • (2007) Int J Prosthodont , vol.20 , Issue.6 , pp. 573-575
    • Balkenhol, M.1    Ferger, P.2    Wöstmann, B.3
  • 10
    • 0036365664 scopus 로고    scopus 로고
    • The influence of the mixing technique on the content of voids in two polyether impression materials
    • PID: 11892614
    • Di Felice R, Scotti R, Belser UC (2002) The influence of the mixing technique on the content of voids in two polyether impression materials. Schweiz Monatsschr Zahnmed 112(1):12–16
    • (2002) Schweiz Monatsschr Zahnmed , vol.112 , Issue.1 , pp. 12-16
    • Di Felice, R.1    Scotti, R.2    Belser, U.C.3
  • 11
    • 45049084951 scopus 로고    scopus 로고
    • Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology
    • PID: 18336900
    • Persson AS, Andersson M, Oden A, Sandborgh-Englund G (2008) Computer aided analysis of digitized dental stone replicas by dental CAD/CAM technology. Dent Mater 24(8):1123–1130
    • (2008) Dent Mater , vol.24 , Issue.8 , pp. 1123-1130
    • Persson, A.S.1    Andersson, M.2    Oden, A.3    Sandborgh-Englund, G.4
  • 12
    • 0021975697 scopus 로고
    • Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study
    • PID: 3882944
    • Belser UC, MacEntee MI, Richter WA (1985) Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study. J Prosthet Dent 53(1):24–29
    • (1985) J Prosthet Dent , vol.53 , Issue.1 , pp. 24-29
    • Belser, U.C.1    MacEntee, M.I.2    Richter, W.A.3
  • 13
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • PID: 5283545
    • McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131(3):107–111
    • (1971) Br Dent J , vol.131 , Issue.3 , pp. 107-111
    • McLean, J.W.1    von Fraunhofer, J.A.2
  • 14
    • 34250653055 scopus 로고    scopus 로고
    • Five-year clinical results of zirconia frameworks for posterior fixed partial dentures
    • PID: 17695869
    • Sailer I, Feher A, Filser F, Gauckler LJ, Lüthy H, Hämmerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20(4):383–388
    • (2007) Int J Prosthodont , vol.20 , Issue.4 , pp. 383-388
    • Sailer, I.1    Feher, A.2    Filser, F.3    Gauckler, L.J.4    Lüthy, H.5    Hämmerle, C.H.6
  • 15
    • 0042924154 scopus 로고    scopus 로고
    • Interactions between the gingiva and the margin of restorations
    • PID: 12716328
    • Padbury A Jr, Eber R, Wang HL (2003) Interactions between the gingiva and the margin of restorations. J Clin Periodontol 30(5):379–385
    • (2003) J Clin Periodontol , vol.30 , Issue.5 , pp. 379-385
    • Padbury, A.1    Eber, R.2    Wang, H.L.3
  • 16
    • 0020850773 scopus 로고
    • Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins
    • PID: 6581173
    • Lang NP, Kiel RA, Anderhalden K (1983) Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins. J Clin Periodontol 10(6):563–578
    • (1983) J Clin Periodontol , vol.10 , Issue.6 , pp. 563-578
    • Lang, N.P.1    Kiel, R.A.2    Anderhalden, K.3
  • 17
    • 43449084359 scopus 로고    scopus 로고
    • Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures
    • PID: 18471247
    • Wettstein F, Sailer I, Roos M, Hämmerle CH (2008) Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures. Eur J Oral Sci 116(3):272–279
    • (2008) Eur J Oral Sci , vol.116 , Issue.3 , pp. 272-279
    • Wettstein, F.1    Sailer, I.2    Roos, M.3    Hämmerle, C.H.4
  • 18
    • 33847045629 scopus 로고    scopus 로고
    • Dental ceramics and the molar crown testing ground
    • PID: 20959944
    • Thompson VP, Rekow DE (2004) Dental ceramics and the molar crown testing ground. J Appl Oral Sci 12(spe):26–36
    • (2004) J Appl Oral Sci , vol.12 , Issue.spe , pp. 26-36
    • Thompson, V.P.1    Rekow, D.E.2
  • 19
    • 36148962932 scopus 로고    scopus 로고
    • Current ceramic materials and systems with clinical recommendations: a systematic review
    • PID: 18021828
    • Conrad HJ, Seong WJ, Pesun IJ (2007) Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 98(5):389–404
    • (2007) J Prosthet Dent , vol.98 , Issue.5 , pp. 389-404
    • Conrad, H.J.1    Seong, W.J.2    Pesun, I.J.3
  • 20
    • 84875279822 scopus 로고    scopus 로고
    • Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and martens hardness
    • PID: 23455168
    • Mörmann W, Stawarczyk B, Ender A, Sener B, Attin T, Mehl A (2013) Wear characteristics of current aesthetic dental restorative CAD/CAM materials: two-body wear, gloss retention, roughness and martens hardness. J Mech Behav Biomed Mater 20:113–125. doi:10.1016/j.jmbbm.2013.01.003 Epub 2013 Jan 23
    • (2013) J Mech Behav Biomed Mater , vol.20 , pp. 113-125
    • Mörmann, W.1    Stawarczyk, B.2    Ender, A.3    Sener, B.4    Attin, T.5    Mehl, A.6
  • 21
    • 84863932573 scopus 로고    scopus 로고
    • Lava ultimate resin nano ceramic for CAD/ CAM: customization case study
    • PID: 22891419
    • Koller M, Arnetzl GV, Holly L, Arnetzl G (2012) Lava ultimate resin nano ceramic for CAD/ CAM: customization case study. Int J Comput Dent 15(2):159–164
    • (2012) Int J Comput Dent , vol.15 , Issue.2 , pp. 159-164
    • Koller, M.1    Arnetzl, G.V.2    Holly, L.3    Arnetzl, G.4
  • 22
    • 84959124974 scopus 로고    scopus 로고
    • Einsatzmöglichkeiten zirkonverstärkter Lithiumsilikat- Keramiken
    • Rinke S, Schäfer S, Schmidt AK (2014) Einsatzmöglichkeiten zirkonverstärkter Lithiumsilikat- Keramiken. Quintessenz Zahntech 40(5):536–546
    • (2014) Quintessenz Zahntech , vol.40 , Issue.5 , pp. 536-546
    • Rinke, S.1    Schäfer, S.2    Schmidt, A.K.3
  • 24
    • 84959158178 scopus 로고    scopus 로고
    • A novel CAD/ CAM base metal compared to conventional CoCrMo alloys: an in-vitro study of the long-term metal-ceramic bond strength
    • PID: 24984663
    • Stawarczyk B, Eichberger M, Hoffmann R, Noack F, Schweiger J, Edelhoff D, Beuer F (2014) A novel CAD/ CAM base metal compared to conventional CoCrMo alloys: an in-vitro study of the long-term metal-ceramic bond strength. Oral Health Dent Manag 13(2):446–452
    • (2014) Oral Health Dent Manag , vol.13 , Issue.2 , pp. 446-452
    • Stawarczyk, B.1    Eichberger, M.2    Hoffmann, R.3    Noack, F.4    Schweiger, J.5    Edelhoff, D.6    Beuer, F.7
  • 25
    • 84888638427 scopus 로고    scopus 로고
    • The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems
    • PID: 23371756
    • Brawek PK, Wolfart S, Endres L, Kirsten A, Reich S (2013) The clinical accuracy of single crowns exclusively fabricated by digital workflow-the comparison of two systems. Clin Oral Investig 17(9):2119–2125
    • (2013) Clin Oral Investig , vol.17 , Issue.9 , pp. 2119-2125
    • Brawek, P.K.1    Wolfart, S.2    Endres, L.3    Kirsten, A.4    Reich, S.5
  • 26
    • 57449084616 scopus 로고    scopus 로고
    • High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations
    • PID: 18620748
    • Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater 25(1):121–128
    • (2009) Dent Mater , vol.25 , Issue.1 , pp. 121-128
    • Beuer, F.1    Schweiger, J.2    Eichberger, M.3    Kappert, H.F.4    Gernet, W.5    Edelhoff, D.6
  • 27
    • 84879134848 scopus 로고    scopus 로고
    • 3D monitoring and quality control using intraoral optical camera systems
    • PID: 23641662
    • Mehl A, Koch R, Zaruba M, Ender A (2013) 3D monitoring and quality control using intraoral optical camera systems. Int J Comput Dent 16(1):23–36
    • (2013) Int J Comput Dent , vol.16 , Issue.1 , pp. 23-36
    • Mehl, A.1    Koch, R.2    Zaruba, M.3    Ender, A.4
  • 28
    • 33749262810 scopus 로고    scopus 로고
    • Dental CAD/CAM systems: a 20-year success story
    • PID: 16950931
    • Rekow ED (2006) Dental CAD/CAM systems: a 20-year success story. J Am Dent Assoc 137(Suppl):5S–6S
    • (2006) J Am Dent Assoc , vol.137 , pp. 5S-6S
    • Rekow, E.D.1
  • 29
    • 0030308994 scopus 로고    scopus 로고
    • The new creativity in ceramic restorations: dental CAD-CIM
    • PID: 9452675
    • Mörmann WH, Bindl A (1996) The new creativity in ceramic restorations: dental CAD-CIM. Quintessence Int 27(12):821–828
    • (1996) Quintessence Int , vol.27 , Issue.12 , pp. 821-828
    • Mörmann, W.H.1    Bindl, A.2
  • 30
    • 59049089425 scopus 로고    scopus 로고
    • Accuracy testing of a new intraoral 3D camera
    • PID: 19213357
    • Mehl A, Ender A, Mörmann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12(1):11–28
    • (2009) Int J Comput Dent , vol.12 , Issue.1 , pp. 11-28
    • Mehl, A.1    Ender, A.2    Mörmann, W.3    Attin, T.4
  • 31
    • 63849304492 scopus 로고    scopus 로고
    • Digital impression taking with reproducibly high precision
    • PID: 19413271
    • Ziegler M (2009) Digital impression taking with reproducibly high precision. Int J Comput Dent 12(2):159–163
    • (2009) Int J Comput Dent , vol.12 , Issue.2 , pp. 159-163
    • Ziegler, M.1
  • 32
    • 85044710322 scopus 로고    scopus 로고
    • The development of the Lava chairside oral scanner C.O.S. technology—masterstroke of a legion of talented and committed people
    • PID: 19413272
    • Rohaly J (2009) The development of the Lava chairside oral scanner C.O.S. technology—masterstroke of a legion of talented and committed people. Int J Comput Dent 12(2):165–169
    • (2009) Int J Comput Dent , vol.12 , Issue.2 , pp. 165-169
    • Rohaly, J.1
  • 33
    • 84876426016 scopus 로고    scopus 로고
    • Accuracy of digital models obtained by direct and indirect data capturing
    • PID: 22847854, PMID: 22847854
    • Güth JF, Keul C, Stimmelmayr M, Beuer F, Edelhoff D (2013) Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig 17(4):1201–1208, PMID: 22847854
    • (2013) Clin Oral Investig , vol.17 , Issue.4 , pp. 1201-1208
    • Güth, J.F.1    Keul, C.2    Stimmelmayr, M.3    Beuer, F.4    Edelhoff, D.5
  • 34
    • 77954569088 scopus 로고    scopus 로고
    • Dentistry a la carte: in-office CAD/CAM technology
    • PID: 20572526
    • Kachalia PR, Geissberger MJ (2010) Dentistry a la carte: in-office CAD/CAM technology. J Calif Dent Assoc 38(5):323–330
    • (2010) J Calif Dent Assoc , vol.38 , Issue.5 , pp. 323-330
    • Kachalia, P.R.1    Geissberger, M.J.2
  • 35
    • 77957280346 scopus 로고    scopus 로고
    • Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
    • PID: 20381576
    • Syrek A, Reich G, Ranftl D, Klein C, Cerny B, Brodesser J (2010) Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 38(7):553–559
    • (2010) J Dent , vol.38 , Issue.7 , pp. 553-559
    • Syrek, A.1    Reich, G.2    Ranftl, D.3    Klein, C.4    Cerny, B.5    Brodesser, J.6
  • 36
    • 84867400213 scopus 로고    scopus 로고
    • Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling
    • PID: 22027653
    • Cardelli P, Scotti R, Monaco C (2011) Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling. J Dent. doi:10.1016/j.jdent.2011.10.005
    • (2011) J Dent
    • Cardelli, P.1    Scotti, R.2    Monaco, C.3
  • 37
    • 17844402484 scopus 로고    scopus 로고
    • Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
    • PID: 15819826
    • Reich S et al (2005) Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems. Eur J Oral Sci 113(2):174–179
    • (2005) Eur J Oral Sci , vol.113 , Issue.2 , pp. 174-179
    • Reich, S.1
  • 38
    • 56749179118 scopus 로고    scopus 로고
    • Clinical fit of four-unit zirconia posterior fixed dental prostheses
    • PID: 19049530
    • Reich S, Kappe K, Teschner H, Schmitt J (2008) Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 116(6):579–584
    • (2008) Eur J Oral Sci , vol.116 , Issue.6 , pp. 579-584
    • Reich, S.1    Kappe, K.2    Teschner, H.3    Schmitt, J.4
  • 39
    • 69649091862 scopus 로고    scopus 로고
    • Precision of fit: zirconia three-unit fixed denta prostheses
    • PID: 18769946
    • Beuer F, Naumann M, Gernet W (2009) Precision of fit: zirconia three-unit fixed denta prostheses. Clin Oral Investig 13:343–349
    • (2009) Clin Oral Investig , vol.13 , pp. 343-349
    • Beuer, F.1    Naumann, M.2    Gernet, W.3
  • 40
    • 84894547254 scopus 로고    scopus 로고
    • Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    • PID: 23716064
    • Almeida e Silva JS, Erdelt K, Edelhoff D, Araujo E, Stimmelmayr M, Vieira LC, Güth JF (2014) Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 18(2):515–523. doi:10.1007/s00784-013-0987-2
    • (2014) Clin Oral Investig , vol.18 , Issue.2 , pp. 515-523
    • Almeida e Silva, J.S.1    Erdelt, K.2    Edelhoff, D.3    Araujo, E.4    Stimmelmayr, M.5    Vieira, L.C.6    Güth, J.F.7
  • 41
    • 84881612097 scopus 로고    scopus 로고
    • Accuracy of digital and conventional impression techniques and workflow
    • PID: 23086333
    • Seelbach P, Brueckel C, Wöstmann B (2013) Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig 17(7):1759–1764
    • (2013) Clin Oral Investig , vol.17 , Issue.7 , pp. 1759-1764
    • Seelbach, P.1    Brueckel, C.2    Wöstmann, B.3
  • 42
    • 84897026100 scopus 로고    scopus 로고
    • Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study
    • PID: 24522150
    • Keul C, Stawarczyk B, Erdelt KJ, Beuer F, Edelhoff D, Güth JF (2014) Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization—a laboratory study. Dent Mater 30(4):400–407
    • (2014) Dent Mater , vol.30 , Issue.4 , pp. 400-407
    • Keul, C.1    Stawarczyk, B.2    Erdelt, K.J.3    Beuer, F.4    Edelhoff, D.5    Güth, J.F.6
  • 43
    • 84897902654 scopus 로고    scopus 로고
    • Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions
    • PID: 24723954
    • Svanborg P, Skjerven H, Carlsson P, Eliasson A, Karlsson S, Ortorp A (2014) Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions. Int J Dent. doi:10.1155/2014/534382 Epub 2014 Mar 3
    • (2014) Int J Dent
    • Svanborg, P.1    Skjerven, H.2    Carlsson, P.3    Eliasson, A.4    Karlsson, S.5    Ortorp, A.6
  • 44
    • 84871692499 scopus 로고    scopus 로고
    • Digital vs. conventional implant impressions: efficiency outcomes
    • Lee SJ, Gallucci GO (2014) Digital vs. conventional implant impressions: efficiency outcomes. Clin Oral Implants 24(1):111–115
    • (2014) Clin Oral Implants , vol.24 , Issue.1 , pp. 111-115
    • Lee, S.J.1    Gallucci, G.O.2
  • 45
    • 69949188485 scopus 로고    scopus 로고
    • A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress
    • PID: 19715151
    • Gozdowski S, Reich S (2009) A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress. Int J Comput Dent 12(3):279–289
    • (2009) Int J Comput Dent , vol.12 , Issue.3 , pp. 279-289
    • Gozdowski, S.1    Reich, S.2
  • 46
    • 84902126764 scopus 로고    scopus 로고
    • The time efficiency of intraoral scanner: an in vitro com-parative study
    • PID: 24878708
    • Patzelt SB, Lamprinos C, Stampf S, Att W (2014) The time efficiency of intraoral scanner: an in vitro com-parative study. J Am Dent Assoc 145(6):542–551
    • (2014) J Am Dent Assoc , vol.145 , Issue.6 , pp. 542-551
    • Patzelt, S.B.1    Lamprinos, C.2    Stampf, S.3    Att, W.4
  • 49
    • 0026127801 scopus 로고
    • An investigation of dental luting cement solubility as a function of the marginal gap
    • PID: 2056466
    • Jacobs MS, Windeler AS (1991) An investigation of dental luting cement solubility as a function of the marginal gap. J Prosthet Dent 65(3):436–442
    • (1991) J Prosthet Dent , vol.65 , Issue.3 , pp. 436-442
    • Jacobs, M.S.1    Windeler, A.S.2
  • 50
    • 80155198445 scopus 로고    scopus 로고
    • Influence of preparation form, luting space setting and cement type on the marginal and internal fit of CAD/CAM crown copings
    • PID: 22141231
    • Hmaidouch R, Neumann R, Mueller WD (2011) Influence of preparation form, luting space setting and cement type on the marginal and internal fit of CAD/CAM crown copings. Int J Comput Dent 14(3):219–226
    • (2011) Int J Comput Dent , vol.14 , Issue.3 , pp. 219-226
    • Hmaidouch, R.1    Neumann, R.2    Mueller, W.D.3
  • 52
    • 0037982937 scopus 로고    scopus 로고
    • Matching point clouds: limits and possibilities
    • PID: 12680049
    • Rudolph H, Quaas S, Luthardt RG (2002) Matching point clouds: limits and possibilities. Int J Comput Dent 5(2–3):155–164
    • (2002) Int J Comput Dent , vol.5 , Issue.2-3 , pp. 155-164
    • Rudolph, H.1    Quaas, S.2    Luthardt, R.G.3
  • 53
    • 79954438032 scopus 로고    scopus 로고
    • Full arch scans: conventional versus digital impressions—an in-vitro study
    • PID: 21657122
    • Ender A, Mehl A (2011) Full arch scans: conventional versus digital impressions—an in-vitro study. Int J Comput Dent 14(1):11–21
    • (2011) Int J Comput Dent , vol.14 , Issue.1 , pp. 11-21
    • Ender, A.1    Mehl, A.2
  • 54
    • 84959091835 scopus 로고    scopus 로고
    • Analyse des Einflusses der Puderapplikation auf die Genauigkeit optischer Digitalisierungen
    • Quaas S, Loos R, Sporbeck H, Luthardt RG (2005) Analyse des Einflusses der Puderapplikation auf die Genauigkeit optischer Digitalisierungen. Dtsch Zahnärztl Z 60:96–99
    • (2005) Dtsch Zahnärztl Z , vol.60 , pp. 96-99
    • Quaas, S.1    Loos, R.2    Sporbeck, H.3    Luthardt, R.G.4
  • 55
    • 84879182149 scopus 로고    scopus 로고
    • Influence of scanning strategies on the accuracy of digital intraoral scanning systems
    • PID: 23641661
    • Ender A, Mehl A (2013) Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 16(1):11–21
    • (2013) Int J Comput Dent , vol.16 , Issue.1 , pp. 11-21
    • Ender, A.1    Mehl, A.2
  • 56
    • 84886412061 scopus 로고    scopus 로고
    • Precision of intraoral digital dental im- pressions with iTero and extraoral digitization with the iTero and a model scanner
    • Flugge TV, Schlager S, Nelson K, Nahles S, Metzger MC (2013) Precision of intraoral digital dental im- pressions with iTero and extraoral digitization with the iTero and a model scanner. Am J Orthod Dentofac Orthop 144(3):471–478
    • (2013) Am J Orthod Dentofac Orthop , vol.144 , Issue.3 , pp. 471-478
    • Flugge, T.V.1    Schlager, S.2    Nelson, K.3    Nahles, S.4    Metzger, M.C.5
  • 57
    • 38149014578 scopus 로고    scopus 로고
    • Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method
    • PID: 18197844
    • Laurent M, Scheer P, Dejou J, Laborde G (2008) Clinical evaluation of the marginal fit of cast crowns—validation of the silicone replica method. J Oral Rehabil 35(2):116–122
    • (2008) J Oral Rehabil , vol.35 , Issue.2 , pp. 116-122
    • Laurent, M.1    Scheer, P.2    Dejou, J.3    Laborde, G.4
  • 58
    • 77954356003 scopus 로고    scopus 로고
    • Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses
    • PID: 20059649
    • Kohorst P, Brinkmann H, Dittmer MP, Borchers L, Stiesch M (2010) Influence of the veneering process on the marginal fit of zirconia fixed dental prostheses. J Oral Rehabil 37(4):283–291
    • (2010) J Oral Rehabil , vol.37 , Issue.4 , pp. 283-291
    • Kohorst, P.1    Brinkmann, H.2    Dittmer, M.P.3    Borchers, L.4    Stiesch, M.5
  • 59
    • 0033628733 scopus 로고    scopus 로고
    • Determination of the minimum number of marginal gap measurements required for practical in-vitro testing
    • Groten M, Axmann D, Probster L, Weber H (2000) Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent 83(1):p40–p49
    • (2000) J Prosthet Dent , vol.83 , Issue.1 , pp. p40-p49
    • Groten, M.1    Axmann, D.2    Probster, L.3    Weber, H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.