메뉴 건너뛰기




Volumn 31, Issue 4, 2012, Pages 601-609

Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings

Author keywords

CAD CAM system; Marginal fit; Zirconia coping

Indexed keywords

CAD/CAM SYSTEM; CAD/CAMS; COMPLEX INTERACTION; MANUAL ADAPTATION; MANUFACTURING PROCESS; MARGINAL FIT; MARGINAL GAP; MILLING PROCESS; MILLING SYSTEMS; MULTIFACTORIAL ANALYSIS; OPTIMAL FITTING; PROCESSING CHAIN;

EID: 84864675575     PISSN: 02874547     EISSN: 18811361     Source Type: Journal    
DOI: 10.4012/dmj.2012-017     Document Type: Article
Times cited : (50)

References (34)
  • 1
    • 78651262006 scopus 로고    scopus 로고
    • Clinical trials in zirconia: A systematic review
    • Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil 2010; 37: 641-652
    • (2010) J Oral Rehabil , vol.37 , pp. 641-652
    • Al-Amleh, B.1    Lyons, K.2    Swain, M.3
  • 2
    • 77956529457 scopus 로고    scopus 로고
    • Survival probability of zirconia-based fixed dental prostheses up to 5 yr: A systematic review of the literature
    • Schley JS, Heussen N, Reich S, Fischer J, Haselhuhn K, Wolfart S. Survival probability of zirconia-based fixed dental prostheses up to 5 yr: a systematic review of the literature. Eur J Oral Sci 2010; 118: 443-450.
    • (2010) Eur J Oral Sci , vol.118 , pp. 443-450
    • Schley, J.S.1    Heussen, N.2    Reich, S.3    Fischer, J.4    Haselhuhn, K.5    Wolfart, S.6
  • 3
    • 79952273419 scopus 로고    scopus 로고
    • Survival of zirconia-and metalsupported fixed dental prostheses: A systematic review
    • Heintze SD, Rousson V. Survival of zirconia-and metalsupported fixed dental prostheses: a systematic review. Int J Prosthodont 2010; 23: 493-502.
    • (2010) Int J Prosthodont , vol.23 , pp. 493-502
    • Heintze, S.D.1    Rousson, V.2
  • 4
    • 0025684903 scopus 로고
    • Gingival margins for crowns: A review and discussion. Part II: Discrepancies and configurations
    • Hunter AJ, Hunter AR. Gingival margins for crowns: a review and discussion. Part II: Discrepancies and configurations. J Prosthet Dent 1990; 64: 636-642.
    • (1990) J Prosthet Dent , vol.64 , pp. 636-642
    • Hunter, A.J.1    Hunter, A.R.2
  • 6
    • 84864717827 scopus 로고    scopus 로고
    • Influence of porcelain veneering onthe marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns
    • Pak HS, Han JS, Lee JB, Kim SH, Yang JH. Influence of porcelain veneering onthe marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns. J Adv Prosthodont 2010; 2: 33-38.
    • (2010) J Adv Prosthodont , vol.2 , pp. 33-38
    • Pak, H.S.1    Han, J.S.2    Lee, J.B.3    Kim, S.H.4    Yang, J.H.5
  • 7
    • 0026234239 scopus 로고
    • Evaluation of marginal adaptation of all-ceramic crowns and metal ceramic crowns
    • Vahidi F, Egloff ET, Panno FV. Evaluation of marginal adaptation of all-ceramic crowns and metal ceramic crowns. J Prosthet Dent 1991; 66: 426-431.
    • (1991) J Prosthet Dent , vol.66 , pp. 426-431
    • Vahidi, F.1    Egloff, E.T.2    Panno, F.V.3
  • 8
    • 0028711133 scopus 로고
    • In vitro marginal adaptation of alumina porcelain ceramic crowns
    • Pera P, Gilodi S, Bassi F, Carossa S. In vitro marginal adaptation of alumina porcelain ceramic crowns. J Prosthet Dent 1994; 72: 585-590.
    • (1994) J Prosthet Dent , vol.72 , pp. 585-590
    • Pera, P.1    Gilodi, S.2    Bassi, F.3    Carossa, S.4
  • 9
    • 0030270608 scopus 로고    scopus 로고
    • Influence of marginalconfiguration and porcelain addition on the fit of In-Ceramcrowns
    • Shearer B, Gough MB, Setchell DJ. Influence of marginalconfiguration and porcelain addition on the fit of In-Ceramcrowns. Biomaterials 1996; 17: 1891-1895.
    • (1996) Biomaterials , vol.17 , pp. 1891-1895
    • Shearer, B.1    Gough, M.B.2    Setchell, D.J.3
  • 10
    • 15944372291 scopus 로고    scopus 로고
    • Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems
    • Balkaya MC, Cinar A, Pamuk S. Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems. J Prosthet Dent 2005; 93: 346-355.
    • (2005) J Prosthet Dent , vol.93 , pp. 346-355
    • Balkaya, M.C.1    Cinar, A.2    Pamuk, S.3
  • 11
    • 77957292587 scopus 로고    scopus 로고
    • Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system
    • Baig MR, Tan KB, Nicholls JI. Evaluation of the marginal fit of a zirconia ceramic computer-aided machined (CAM) crown system. J Prosthet Dent 2010; 104: 216-227.
    • (2010) J Prosthet Dent , vol.104 , pp. 216-227
    • Baig, M.R.1    Tan, K.B.2    Nicholls, J.I.3
  • 12
    • 5444219837 scopus 로고    scopus 로고
    • Precision of a CAD/CAM technique for theproduction of zirconium dioxide copings
    • Coli P, Karlsson S. Precision of a CAD/CAM technique for theproduction of zirconium dioxide copings. Int J Prosthodont 2004; 17: 577-580.
    • (2004) Int J Prosthodont , vol.17 , pp. 577-580
    • Coli, P.1    Karlsson, S.2
  • 13
    • 20044367673 scopus 로고    scopus 로고
    • Marginal and internal fit of allceramic CAD/CAM crown-copings on chamfer preparations
    • Bindl A, Mormann WH. Marginal and internal fit of allceramic CAD/CAM crown-copings on chamfer preparations. J Oral Rehabil 2005; 32: 441-447.
    • (2005) J Oral Rehabil , vol.32 , pp. 441-447
    • Bindl, A.1    Mormann, W.H.2
  • 14
    • 79953672204 scopus 로고    scopus 로고
    • Fit of single tooth zirconia copings: Comparison between various manufacturing processes
    • Grenade C, Mainjot A, Vanheusden A. Fit of single tooth zirconia copings: comparison between various manufacturing processes. J Prosthet Dent 2011; 105: 249-255.
    • (2011) J Prosthet Dent , vol.105 , pp. 249-255
    • Grenade, C.1    Mainjot, A.2    Vanheusden, A.3
  • 15
    • 79951657283 scopus 로고    scopus 로고
    • Comparison of the marginal fit of different coping materials and designs produced by computer aided manufacturing systems
    • Karataşli O, Kursoǧlu P, Capa N, Kazazoǧlu E. Comparison of the marginal fit of different coping materials and designs produced by computer aided manufacturing systems. Dent Mater J 2011; 30: 97-102.
    • (2011) Dent Mater J , vol.30 , pp. 97-102
    • Karataşli, O.1    Kursoǧlu, P.2    Capa, N.3    Kazazoǧlu, E.4
  • 16
    • 0027620312 scopus 로고
    • The fit of Procera titanium crowns. An in vitro and clinical study
    • Karlsson S. The fit of Procera titanium crowns. An in vitro and clinical study. Acta Odontol Scand 1993; 51: 129-134.
    • (1993) Acta Odontol Scand , vol.51 , pp. 129-134
    • Karlsson, S.1
  • 17
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971; 131: 107-111.
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    von Fraunhofer, J.A.2
  • 18
    • 57449093791 scopus 로고    scopus 로고
    • Gernet W, Naumann M. Effect of preparation angles on the precision of zirconia copings fabricated by CAD/CAM systems
    • Beuer F, Edelhoff D. Gernet W, Naumann M. Effect of preparation angles on the precision of zirconia copings fabricated by CAD/CAM systems. Dent Mater J 2008; 27: 814-820.
    • (2008) Dent Mater J , vol.27 , pp. 814-820
    • Beuer, F.1    Edelhoff, D.2
  • 19
    • 67651011653 scopus 로고    scopus 로고
    • Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    • Beuer F, Aggstaller H, Richter J, Edelhoff D, Gernet W. Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 2009; 40: 243-250.
    • (2009) Quintessence Int , vol.40 , pp. 243-250
    • Beuer, F.1    Aggstaller, H.2    Richter, J.3    Edelhoff, D.4    Gernet, W.5
  • 20
    • 33845920278 scopus 로고    scopus 로고
    • Axial-wall inclination angle and vertical height interactions in molar full crown preparations
    • Bowley JF, Kieser J. Axial-wall inclination angle and vertical height interactions in molar full crown preparations. J Dent 2007; 35: 117-123.
    • (2007) J Dent , vol.35 , pp. 117-123
    • Bowley, J.F.1    Kieser, J.2
  • 21
    • 72149127682 scopus 로고    scopus 로고
    • Influence of tooth preparation taper and cement type on recementation strength of complete metal crowns
    • Ayad MF, Johnston WM, Rosenstiel SF. Influence of tooth preparation taper and cement type on recementation strength of complete metal crowns. J Prosthet Dent 2009; 102: 354-361.
    • (2009) J Prosthet Dent , vol.102 , pp. 354-361
    • Ayad, M.F.1    Johnston, W.M.2    Rosenstiel, S.F.3
  • 22
    • 34250612616 scopus 로고    scopus 로고
    • A systematic review of the survival and complication rates of ll-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns
    • Pjetursson BE, Sailer I, Zwahlen M, Hämmerle CH. A systematic review of the survival and complication rates of ll-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: Single crowns. Clin Oral Implants Res 2007; 19: 326-328.
    • (2007) Clin Oral Implants Res , vol.19 , pp. 326-328
    • Pjetursson, B.E.1    Sailer, I.2    Zwahlen, M.3    Hämmerle, C.H.4
  • 23
    • 77952296078 scopus 로고    scopus 로고
    • Prospective evaluation of zirconia posterior fixed partial dentures: Fouryear clinical results
    • Roediger M, Gersdorff N, Huels A, Rinke S. Prospective evaluation of zirconia posterior fixed partial dentures: fouryear clinical results. Int J Prosthodont 2010; 23: 141-148.
    • (2010) Int J Prosthodont , vol.23 , pp. 141-148
    • Roediger, M.1    Gersdorff, N.2    Huels, A.3    Rinke, S.4
  • 24
    • 0030279686 scopus 로고    scopus 로고
    • Retention of metal ceramic crowns cemented with resin cements: Effects of preparation taper and height
    • el-Mowafy OM, Fenton AH, Forrester N, Milenkovic M. Retention of metal ceramic crowns cemented with resin cements: effects of preparation taper and height. J Prosthet Dent 1996; 76: 524-529.
    • (1996) J Prosthet Dent , vol.76 , pp. 524-529
    • el-Mowafy, O.M.1    Fenton, A.H.2    Forrester, N.3    Milenkovic, M.4
  • 26
    • 79960149390 scopus 로고    scopus 로고
    • Different CAD/CAM-processing routes for zirconia restotations: Influence on fitting accuracy
    • Kohorst P, Junghanns J, Dittmer MP, Borchers L, Stiesch M. Different CAD/CAM-processing routes for zirconia restotations: influence on fitting accuracy. Clin Oral Investig 2011; 15: 527-536.
    • (2011) Clin Oral Investig , vol.15 , pp. 527-536
    • Kohorst, P.1    Junghanns, J.2    Dittmer, M.P.3    Borchers, L.4    Stiesch, M.5
  • 27
    • 57349196555 scopus 로고    scopus 로고
    • Marginal and internal fits of fixed dental prostheses zirconia retainers
    • Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J. Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 2009; 25: 94-102.
    • (2009) Dent Mater , vol.25 , pp. 94-102
    • Beuer, F.1    Aggstaller, H.2    Edelhoff, D.3    Gernet, W.4    Sorensen, J.5
  • 29
    • 0033628733 scopus 로고    scopus 로고
    • Determination of the minimum number of marginal gap measurements required for practical in-vitro testing
    • Groten M, Axmann D, Pröbster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent 2000; 83: 40-49.
    • (2000) J Prosthet Dent , vol.83 , pp. 40-49
    • Groten, M.1    Axmann, D.2    Pröbster, L.3    Weber, H.4
  • 30
    • 79251493434 scopus 로고    scopus 로고
    • Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings
    • Martinez-Rus F, Suarez MJ, Rivear B, Pradies G. Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings. J Prosthet Dent 2011; 105: 108-114.
    • (2011) J Prosthet Dent , vol.105 , pp. 108-114
    • Martinez-Rus, F.1    Suarez, M.J.2    Rivear, B.3    Pradies, G.4
  • 31
    • 79955611436 scopus 로고    scopus 로고
    • Marginal, internal fit and microleakage of zirconia infrastructures: An in-vitro study
    • Korkut L, Cotert HS, Kurtulmus H. Marginal, internal fit and microleakage of zirconia infrastructures: an in-vitro study. Oper Dent 2011; 36: 72-79.
    • (2011) Oper Dent , vol.36 , pp. 72-79
    • Korkut, L.1    Cotert, H.S.2    Kurtulmus, H.3
  • 32
    • 79952479038 scopus 로고    scopus 로고
    • Influence of CAD/CAM scanning method and toothpreparations design on the vertical misfit of zirconia crown copings
    • Castillo Oyagüe R, Sanchez-Jorge MI, Sanchez Turrion A. Influence of CAD/CAM scanning method and toothpreparations design on the vertical misfit of zirconia crown copings. Am J Dent 2010; 23: 341-346.
    • (2010) Am J Dent , vol.23 , pp. 341-346
    • Castillo Oyagüe, R.1    Sanchez-Jorge, M.I.2    Sanchez Turrion, A.3
  • 33
    • 77958090670 scopus 로고    scopus 로고
    • Fit of zirconia fixed partial denture: A systematic review
    • Abduo J, Lyons K, Swain M. Fit of zirconia fixed partial denture: a systematic review. J Oral Rehabil 2010; 37: 866-876.
    • (2010) J Oral Rehabil , vol.37 , pp. 866-876
    • Abduo, J.1    Lyons, K.2    Swain, M.3
  • 34
    • 17844402484 scopus 로고    scopus 로고
    • Clinical fit of all-ceramic three-unit fixed partial dentures generated with three different CAD/CAM systems
    • Reich S, Wichmann M, Nkenke E, Proeschel P. Clinical fit of all-ceramic three-unit fixed partial dentures generated with three different CAD/CAM systems. Eur J Oral Sci 2005; 113: 174-179.
    • (2005) Eur J Oral Sci , vol.113 , pp. 174-179
    • Reich, S.1    Wichmann, M.2    Nkenke, E.3    Proeschel, P.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.