메뉴 건너뛰기




Volumn 26, Issue 8, 2017, Pages 650-655

An In Vitro Study of Factors Influencing the Performance of Digital Intraoral Impressions Operating on Active Wavefront Sampling Technology with Multiple Implants in the Edentulous Maxilla

Author keywords

accuracy; CAD CAM; dental implants; digital impression; Intraoral scanner

Indexed keywords

COMPUTER AIDED DESIGN; DENTAL IMPRESSION; EDENTULOUSNESS; HUMAN; IMAGE PROCESSING; IN VITRO STUDY; MAXILLA; MOUTH; TOOTH IMPLANT;

EID: 84959299390     PISSN: 1059941X     EISSN: 1532849X     Source Type: Journal    
DOI: 10.1111/jopr.12457     Document Type: Article
Times cited : (120)

References (30)
  • 1
    • 77953574592 scopus 로고    scopus 로고
    • Effect of implant angulation, connection lenght and impression material on the dimensional accuracy of implant impressions: An in vitro comparative study
    • Sorrentino R, Gherlone EF, Calesini G, et al: Effect of implant angulation, connection lenght and impression material on the dimensional accuracy of implant impressions: an in vitro comparative study. Clin Implant Dent Relat Res 2010;12:63-71
    • (2010) Clin Implant Dent Relat Res , vol.12 , pp. 63-71
    • Sorrentino, R.1    Gherlone, E.F.2    Calesini, G.3
  • 2
    • 84921956618 scopus 로고    scopus 로고
    • Accuracy of impressions of multiple implants in the edentulous arch: A systematic review
    • Baig MR: Accuracy of impressions of multiple implants in the edentulous arch: a systematic review. Int J Oral Maxillofac Implants 2014;29:869-880
    • (2014) Int J Oral Maxillofac Implants , vol.29 , pp. 869-880
    • Baig, M.R.1
  • 3
    • 84916236812 scopus 로고    scopus 로고
    • Accuracy of implant impressions for partially and completely edentulous patients: A systematic review
    • Papaspyridakos P, Chen CJ, Gallucci GO, et al: Accuracy of implant impressions for partially and completely edentulous patients: a systematic review. Int J Oral Maxillofac Implants 2014;29:836-845
    • (2014) Int J Oral Maxillofac Implants , vol.29 , pp. 836-845
    • Papaspyridakos, P.1    Chen, C.J.2    Gallucci, G.O.3
  • 4
    • 79952368966 scopus 로고    scopus 로고
    • Current challenges in successful rehabilitation with oral implants
    • Wenneberg A, Albrektsson T: Current challenges in successful rehabilitation with oral implants. J Oral Rehabil 2011;38:286-294
    • (2011) J Oral Rehabil , vol.38 , pp. 286-294
    • Wenneberg, A.1    Albrektsson, T.2
  • 5
    • 0038644505 scopus 로고    scopus 로고
    • Accuracy of open tray implant impressions: An in vitro comparison of stock versus custom trays
    • Burns J, Palmer R, Howe L, et al: Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays. J Prosthet Dent 2003;89:250-255
    • (2003) J Prosthet Dent , vol.89 , pp. 250-255
    • Burns, J.1    Palmer, R.2    Howe, L.3
  • 6
    • 38949213982 scopus 로고    scopus 로고
    • Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    • Lee H, Ercoli C, Funkenbusch PD, et al: Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study. J Prosthet Dent 2008;99:107-113
    • (2008) J Prosthet Dent , vol.99 , pp. 107-113
    • Lee, H.1    Ercoli, C.2    Funkenbusch, P.D.3
  • 7
    • 84902126764 scopus 로고    scopus 로고
    • The time efficiency of intraoral scanners: An in vitro comparative study
    • Patzelt SB, Lamprinos C, Stampf S, et al: The time efficiency of intraoral scanners: an in vitro comparative study. J Am Dent Assoc 2014;145:542-551
    • (2014) J am Dent Assoc , vol.145 , pp. 542-551
    • Patzelt, S.B.1    Lamprinos, C.2    Stampf, S.3
  • 8
    • 84355161961 scopus 로고    scopus 로고
    • The future of dental devices is digital
    • Van Noort R: The future of dental devices is digital. Dent Mater 2012;28:3-12
    • (2012) Dent Mater , vol.28 , pp. 3-12
    • Van Noort, R.1
  • 9
    • 84902210488 scopus 로고    scopus 로고
    • Using stereophotogrammetric technology for obtaining intraoral digital impressions of implants
    • Pradíes G, Ferreiroa A, Özcan M, et al: Using stereophotogrammetric technology for obtaining intraoral digital impressions of implants. J Am Dent Assoc 2014;145:338-344
    • (2014) J am Dent Assoc , vol.145 , pp. 338-344
    • Pradíes, G.1    Ferreiroa, A.2    Özcan, M.3
  • 10
    • 84904021692 scopus 로고    scopus 로고
    • Impression of multiple implants using photogrammetry: Description of technique and case presentation
    • Peñarrocha-Oltra D, Agustín-Panadero R, Bagán L, et al: Impression of multiple implants using photogrammetry: description of technique and case presentation. Med Oral Patol Oral Cir Bucal 2014;9:366-371
    • (2014) Med Oral Patol Oral Cir Bucal , vol.9 , pp. 366-371
    • Peñarrocha-Oltra, D.1    Agustín-Panadero, R.2    Bagán, L.3
  • 11
    • 84879182149 scopus 로고    scopus 로고
    • Influence of scanning strategies on the accuracy of digital intraoral scanning systems
    • Ender A, Mehl A: Influence of scanning strategies on the accuracy of digital intraoral scanning systems. Int J Comput Dent 2013;16:11-21
    • (2013) Int J Comput Dent , vol.16 , pp. 11-21
    • Ender, A.1    Mehl, A.2
  • 12
    • 84883430030 scopus 로고    scopus 로고
    • Assessing the feasibility and accuracy of digitizing edentulous jaws
    • Patzelt SB, Vonau S, Stampf S, et al: Assessing the feasibility and accuracy of digitizing edentulous jaws. J Am Dent Assoc 2013;144:914-920
    • (2013) J am Dent Assoc , vol.144 , pp. 914-920
    • Patzelt, S.B.1    Vonau, S.2    Stampf, S.3
  • 13
    • 84902765111 scopus 로고    scopus 로고
    • Accuracy of full-arch scans using intraoral scanners
    • Patzelt SB, Emmanouilidi A, Stampf S, et al: Accuracy of full-arch scans using intraoral scanners. Clin Oral Investig 2014;18:1687-1694
    • (2014) Clin Oral Investig , vol.18 , pp. 1687-1694
    • Patzelt, S.B.1    Emmanouilidi, A.2    Stampf, S.3
  • 14
    • 84921991697 scopus 로고    scopus 로고
    • Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth
    • Giménez B, Özcan M, Martínez-Rus F, et al: Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth. Int J Oral Maxillofac Implants 2014;29:853-862
    • (2014) Int J Oral Maxillofac Implants , vol.29 , pp. 853-862
    • Giménez, B.1    Özcan, M.2    Martínez-Rus, F.3
  • 15
    • 84937684298 scopus 로고    scopus 로고
    • Accuracy of a digital impression system based on active wavefront sampling technology for implants considering operator experience, implant angulation and depth
    • Giménez B, Özcan M, Martínez-Rus F, et al: Accuracy of a digital impression system based on active wavefront sampling technology for implants considering operator experience, implant angulation and depth. Clin Implant Dent Relat Res 2015;30: 56-64
    • (2015) Clin Implant Dent Relat Res , vol.30 , pp. 56-64
    • Giménez, B.1    Özcan, M.2    Martínez-Rus, F.3
  • 16
    • 77957280346 scopus 로고    scopus 로고
    • Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling
    • Syrek A, Reich G, Ranftl D, et al: Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling. J Dent 2010;38:553-559
    • (2010) J Dent , vol.38 , pp. 553-559
    • Syrek, A.1    Reich, G.2    Ranftl, D.3
  • 17
    • 52449134942 scopus 로고    scopus 로고
    • A comparison of fixed prostheses generated from conventional vs 0digitally scanned dental impressions
    • Henkel GL: A comparison of fixed prostheses generated from conventional vs 0digitally scanned dental impressions. Compend Contin Educ Dent 2007;28:422-431
    • (2007) Compend Contin Educ Dent , vol.28 , pp. 422-431
    • Henkel, G.L.1
  • 18
    • 84888638427 scopus 로고    scopus 로고
    • The clinical accuracy of single crowns exclusively fabricated by digital workflow— the comparison of two systems
    • Brawek PK, Wolfart S, Endres L, et al: The clinical accuracy of single crowns exclusively fabricated by digital workflow— the comparison of two systems. Clin Oral Invest 2013;17:2119-2125
    • (2013) Clin Oral Invest , vol.17 , pp. 2119-2125
    • Brawek, P.K.1    Wolfart, S.2    Endres, L.3
  • 19
    • 84881612097 scopus 로고    scopus 로고
    • Accuracy of digital and conventional impression technique and workflow
    • Seelbach P, Brueckel C, Wöstmann B: Accuracy of digital and conventional impression technique and workflow. Clin Oral Investig 2013;17:1759-1764
    • (2013) Clin Oral Investig , vol.17 , pp. 1759-1764
    • Seelbach, P.1    Brueckel, C.2    Wöstmann, B.3
  • 20
    • 84942986932 scopus 로고    scopus 로고
    • Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients
    • Boeddinghaus M, Breloer ES, Rehmann P, et al: Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients. Clin Oral Investig 2015;19:2027-2034
    • (2015) Clin Oral Investig , vol.19 , pp. 2027-2034
    • Boeddinghaus, M.1    Breloer, E.S.2    Rehmann, P.3
  • 21
    • 84922798743 scopus 로고    scopus 로고
    • Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology
    • Pradíes G, Zarauz C, Valverde A, et al: Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions based on wavefront sampling technology. J Dent 2015;43:201-208
    • (2015) J Dent , vol.43 , pp. 201-208
    • Pradíes, G.1    Zarauz, C.2    Valverde, A.3
  • 22
    • 33644824930 scopus 로고    scopus 로고
    • Accuracy of intraoral data acquisition in comparison to the conventional impression
    • Luthardt RG, Loos R, Quaas S, et al: Accuracy of intraoral data acquisition in comparison to the conventional impression. Int J Comput Dent 2005;8:283-294
    • (2005) Int J Comput Dent , vol.8 , pp. 283-294
    • Luthardt, R.G.1    Loos, R.2    Quaas, S.3
  • 23
    • 84876426016 scopus 로고    scopus 로고
    • Accuracy of digital models obtained by direct and indirect data capturing
    • Güth J-F, Keul C, Stimmelmayr M, et al: Accuracy of digital models obtained by direct and indirect data capturing. Clin Oral Investig 2012;17:1202-1208
    • (2012) Clin Oral Investig , vol.17 , pp. 1202-1208
    • Güth, J.-F.1    Keul, C.2    Stimmelmayr, M.3
  • 24
    • 84873578014 scopus 로고    scopus 로고
    • Accuracy of complete-arch dental impressions: A new method of measuring trueness and precision
    • Ender A, Mehl A: Accuracy of complete-arch dental impressions: a new method of measuring trueness and precision. J Prosthet Dent 2013;109:121-128
    • (2013) J Prosthet Dent , vol.109 , pp. 121-128
    • Ender, A.1    Mehl, A.2
  • 25
    • 84865176071 scopus 로고    scopus 로고
    • Application of intra-oral dental scanners in the digital workflow of implantology
    • Van der Meer WJ, Andriessen FS, Wismeijer D, et al: Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One 2012;7:e43312
    • (2012) Plos One , vol.7
    • Van Der Meer, W.J.1    Riessen, F.S.2    Wismeijer, D.3
  • 26
    • 84942258106 scopus 로고    scopus 로고
    • Accuracy of two digital implant impression systems based on confocal microscopy with variations in customized software and clinical parameters
    • Giménez B, Pradíes G, Martínez-Rus F, et al: Accuracy of two digital implant impression systems based on confocal microscopy with variations in customized software and clinical parameters. Int J Oral Maxillofac Implants 2015;30: 56-64
    • (2015) Int J Oral Maxillofac Implants , vol.30 , pp. 56-64
    • Giménez, B.1    Pradíes, G.2    Martínez-Rus, F.3
  • 27
    • 84923249632 scopus 로고    scopus 로고
    • Digital versus conventional implant impressions for edentulous patients: Accuracy outcomes
    • Feb 13, [Epub ahead of print]
    • Papaspyridakos P, Gallucci GO, Chen CJ, et al: Digital versus conventional implant impressions for edentulous patients: accuracy outcomes. Clin Oral Implants Res 2015 Feb 13. doi: 10.1111/clr.12567. [Epub ahead of print]
    • (2015) Clin Oral Implants Res
    • Papaspyridakos, P.1    Gallucci, G.O.2    Chen, C.J.3
  • 28
    • 84881026847 scopus 로고    scopus 로고
    • A clinical protocol for intraoral digital impression of screw-retained CAD/CAM framework on multiple implants base don wavefront sampling technology
    • Moreno A, Giménez B, Ozcan M, et al: A clinical protocol for intraoral digital impression of screw-retained CAD/CAM framework on multiple implants base don wavefront sampling technology. Implant Dent 2013;22:320-325
    • (2013) Implant Dent , vol.22 , pp. 320-325
    • Moreno, A.1    Giménez, B.2    Ozcan, M.3
  • 29
    • 84894547254 scopus 로고    scopus 로고
    • Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques
    • Almeida E Silva JS, Erdelt K, Edelhoff D, et al: Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig 2013;18:515-523
    • (2013) Clin Oral Investig , vol.18 , pp. 515-523
    • Almeida E Silva, J.S.1    Erdelt, K.2    Edelhoff, D.3
  • 30
    • 84958929153 scopus 로고    scopus 로고
    • Implant impression techniques for the edentulous jaw: A summary of three studies
    • Jun 1, [Epub ahead of print]
    • Stimmelmayr M, Beuer F, Edelhoff D, et al: Implant impression techniques for the edentulous jaw: a summary of three studies. J Prosthodont 2015 Jun 1. doi: 10.1111/jopr.12305. [Epub ahead of print]
    • (2015) J Prosthodont
    • Stimmelmayr, M.1    Beuer, F.2    Edelhoff, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.