메뉴 건너뛰기




Volumn 105, Issue 2, 2011, Pages 108-114

Evaluation of the absolute marginal discrepancy of zirconia-based ceramic copings

Author keywords

[No Author keywords available]

Indexed keywords

ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 79251493434     PISSN: 00223913     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-3913(11)60009-7     Document Type: Article
Times cited : (80)

References (50)
  • 1
    • 36148962932 scopus 로고    scopus 로고
    • Current ceramic materials and systems with clinical recommendations: A systematic review
    • HJ Conrad, WJ Seong, IJ Pesun Current ceramic materials and systems with clinical recommendations: a systematic review J Prosthet Dent 98 2007 389 404
    • (2007) J Prosthet Dent , vol.98 , pp. 389-404
    • Conrad, H.J.1    Seong, W.J.2    Pesun, I.J.3
  • 2
    • 9944229063 scopus 로고    scopus 로고
    • Contemporary materials and technologies for all-ceramic fixed partial dentures: A review of the literature
    • AJ Raigrodski Contemporary materials and technologies for all-ceramic fixed partial dentures: a review of the literature J Prosthet Dent 92 2004 557 562
    • (2004) J Prosthet Dent , vol.92 , pp. 557-562
    • Raigrodski, A.J.1
  • 3
  • 4
    • 0033873591 scopus 로고    scopus 로고
    • Transformation toughening in zirconia-containing ceramics
    • RH Hannink, PM Kelly, BC Muddle Transformation toughening in zirconia-containing ceramics J Am Ceram Soc 83 2000 461 487
    • (2000) J Am Ceram Soc , vol.83 , pp. 461-487
    • Hannink, R.H.1    Kelly, P.M.2    Muddle, B.C.3
  • 5
    • 0033301391 scopus 로고    scopus 로고
    • Zirconia-TZP and alumina-advanced technologies for the manufacturing of single crowns
    • RG Luthardt, O Sandkuhl, B Reitz Zirconia-TZP and alumina-advanced technologies for the manufacturing of single crowns Eur J Prosthodont Restor Dent 7 1999 113 119
    • (1999) Eur J Prosthodont Restor Dent , vol.7 , pp. 113-119
    • Luthardt, R.G.1    Sandkuhl, O.2    Reitz, B.3
  • 6
    • 38349192796 scopus 로고    scopus 로고
    • State of the art of zirconia for dental applications
    • I Denry, JR Kelly State of the art of zirconia for dental applications Dent Mater 24 2008 299 307
    • (2008) Dent Mater , vol.24 , pp. 299-307
    • Denry, I.1    Kelly, J.R.2
  • 7
    • 0026127801 scopus 로고
    • An investigation of dental luting cement solubility as a function of the marginal gap
    • MS Jacobs, AS Windeler An investigation of dental luting cement solubility as a function of the marginal gap J Prosthet Dent 65 1991 436 442
    • (1991) J Prosthet Dent , vol.65 , pp. 436-442
    • Jacobs, M.S.1    Windeler, A.S.2
  • 8
    • 0034328155 scopus 로고    scopus 로고
    • Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures
    • KL Knoernschild, SD Campbell Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures J Prosthet Dent 84 2000 492 498
    • (2000) J Prosthet Dent , vol.84 , pp. 492-498
    • Knoernschild, K.L.1    Campbell, S.D.2
  • 10
    • 0013890346 scopus 로고
    • Marginal fit of gold inlay castings
    • GJ Christensen Marginal fit of gold inlay castings J Prosthet Dent 16 1966 297 305
    • (1966) J Prosthet Dent , vol.16 , pp. 297-305
    • Christensen, G.J.1
  • 11
    • 0014891551 scopus 로고
    • Marginal fit of restorations and its relation to periodontal bone level. II. Crowns
    • AL Björn, H Björn, B Grkovic Marginal fit of restorations and its relation to periodontal bone level. II. Crowns Odontol Revy 21 1970 337 346
    • (1970) Odontol Revy , vol.21 , pp. 337-346
    • Björn, A.L.1    Björn, H.2    Grkovic, B.3
  • 12
    • 0035374691 scopus 로고    scopus 로고
    • Nondestructive, in vitro quantification of crown margins
    • CA Mitchell, MR Pintado, WH Douglas Nondestructive, in vitro quantification of crown margins J Prosthet Dent 85 2001 575 584
    • (2001) J Prosthet Dent , vol.85 , pp. 575-584
    • Mitchell, C.A.1    Pintado, M.R.2    Douglas, W.H.3
  • 13
    • 0015209415 scopus 로고
    • The estimation of cement film thickness by an in vivo technique
    • JW McLean, JA von Fraunhofer The estimation of cement film thickness by an in vivo technique Br Dent J 131 1971 107 111
    • (1971) Br Dent J , vol.131 , pp. 107-111
    • McLean, J.W.1    Von Fraunhofer, J.A.2
  • 14
    • 0021975697 scopus 로고
    • Fit of three porcelain-fused-to-metal marginal designs in vivo: A scanning electron microscope study
    • UC Belser, MI MacEntee, WA Richter Fit of three porcelain-fused-to-metal marginal designs in vivo: a scanning electron microscope study J Prosthet Dent 53 1985 24 29
    • (1985) J Prosthet Dent , vol.53 , pp. 24-29
    • Belser, U.C.1    MacEntee, M.I.2    Richter, W.A.3
  • 15
    • 0242321091 scopus 로고    scopus 로고
    • In vitro marginal fit of three all-ceramic crown systems
    • IS Yeo, JH Yang, JB Lee In vitro marginal fit of three all-ceramic crown systems J Prosthet Dent 90 2003 459 464
    • (2003) J Prosthet Dent , vol.90 , pp. 459-464
    • Yeo, I.S.1    Yang, J.H.2    Lee, J.B.3
  • 16
    • 12844276724 scopus 로고    scopus 로고
    • Marginal fit of leucite-glass pressable ceramic restorations and ceramic-pressed-to-metal restorations
    • EB Goldin, NW Boyd 3rd, GR Goldstein, EL Hittelman, VP Thompson Marginal fit of leucite-glass pressable ceramic restorations and ceramic-pressed-to-metal restorations J Prosthet Dent 93 2005 143 147
    • (2005) J Prosthet Dent , vol.93 , pp. 143-147
    • Goldin, E.B.1    Boyd III, N.W.2    Goldstein, G.R.3    Hittelman, E.L.4    Thompson, V.P.5
  • 18
    • 0033628733 scopus 로고    scopus 로고
    • Determination of the minimum number of marginal gap measurements required for practical in-vitro testing
    • M Groten, D Axmann, L Pröbster, H Weber Determination of the minimum number of marginal gap measurements required for practical in-vitro testing J Prosthet Dent 83 2000 40 49
    • (2000) J Prosthet Dent , vol.83 , pp. 40-49
    • Groten, M.1    Axmann, D.2    Pröbster, L.3    Weber, H.4
  • 19
    • 1842863784 scopus 로고    scopus 로고
    • Marginal adaptation of fixed prosthodontics: A new in vitro 360-degree external examination procedure
    • G Gassino, S Barone Monfrin, M Scanu, G Spina, G Preti Marginal adaptation of fixed prosthodontics: a new in vitro 360-degree external examination procedure Int J Prosthodont 17 2004 218 223
    • (2004) Int J Prosthodont , vol.17 , pp. 218-223
    • Gassino, G.1    Barone Monfrin, S.2    Scanu, M.3    Spina, G.4    Preti, G.5
  • 20
    • 79251471678 scopus 로고    scopus 로고
    • Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs
    • E Gonzalo, MJ Suárez, B Serrano, JF Lozano Comparative analysis of two measurement methods for marginal fit in metal-ceramic and zirconia posterior FPDs Int J Prosthodont 22 2009 374 377
    • (2009) Int J Prosthodont , vol.22 , pp. 374-377
    • Gonzalo, E.1    Suárez, M.J.2    Serrano, B.3    Lozano, J.F.4
  • 21
    • 0031302220 scopus 로고    scopus 로고
    • Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro
    • M Groten, S Girthofer, L Pröbster Weber H. Marginal fit consistency of copy-milled all-ceramic crowns during fabrication by light and scanning electron microscopic analysis in vitro J Oral Rehabil 24 1997 871 881
    • (1997) J Oral Rehabil , vol.24 , pp. 871-881
    • Groten, M.1    Girthofer, S.2    Pröbster, L.3    Weber, H.4
  • 22
    • 4444369817 scopus 로고    scopus 로고
    • Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: An in vitro evaluation
    • AF Quintas, F Oliveira, MA Bottino Vertical marginal discrepancy of ceramic copings with different ceramic materials, finish lines, and luting agents: an in vitro evaluation J Prosthet Dent 92 2004 250 257
    • (2004) J Prosthet Dent , vol.92 , pp. 250-257
    • Quintas, A.F.1    Oliveira, F.2    Bottino, M.A.3
  • 23
    • 0030270608 scopus 로고    scopus 로고
    • Influence of marginal configuration and porcelain addition on the fit of In-Ceram crowns
    • B Shearer, MB Gough, DJ Setchell Influence of marginal configuration and porcelain addition on the fit of In-Ceram crowns Biomaterials 17 1996 1891 1895
    • (1996) Biomaterials , vol.17 , pp. 1891-1895
    • Shearer, B.1    Gough, M.B.2    Setchell, D.J.3
  • 25
    • 0024006282 scopus 로고
    • A comparison of the marginal fit of three cast ceramic crown systems
    • P Schaerer, T Sato, A Wohlwend A comparison of the marginal fit of three cast ceramic crown systems J Prosthet Dent 59 1988 534 542
    • (1988) J Prosthet Dent , vol.59 , pp. 534-542
    • Schaerer, P.1    Sato, T.2    Wohlwend, A.3
  • 26
    • 0028711133 scopus 로고
    • In vitro marginal adaptation of alumina porcelain ceramic crowns
    • P Pera, S Gilodi, F Bassi, S Carossa In vitro marginal adaptation of alumina porcelain ceramic crowns J Prosthet Dent 72 1994 585 590
    • (1994) J Prosthet Dent , vol.72 , pp. 585-590
    • Pera, P.1    Gilodi, S.2    Bassi, F.3    Carossa, S.4
  • 27
    • 0031217183 scopus 로고    scopus 로고
    • A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera Crowns
    • F Sulaiman, J Chai, LM Jameson, WT Wozniak A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera Crowns Int J Prosthodont 10 1997 478 484
    • (1997) Int J Prosthodont , vol.10 , pp. 478-484
    • Sulaiman, F.1    Chai, J.2    Jameson, L.M.3    Wozniak, W.T.4
  • 28
    • 20044367673 scopus 로고    scopus 로고
    • Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations
    • A Bindl, WH Mörmann Marginal and internal fit of all-ceramic CAD/CAM crown-copings on chamfer preparations J Oral Rehabil 32 2005 441 447
    • (2005) J Oral Rehabil , vol.32 , pp. 441-447
    • Bindl, A.1    Mörmann, W.H.2
  • 29
    • 5444219837 scopus 로고    scopus 로고
    • Precision of a CAD/CAM technique for the production of zirconium dioxide copings
    • P Coli, S Karlsson Precision of a CAD/CAM technique for the production of zirconium dioxide copings Int J Prosthodont 17 2004 577 580
    • (2004) Int J Prosthodont , vol.17 , pp. 577-580
    • Coli, P.1    Karlsson, S.2
  • 31
    • 0033158951 scopus 로고    scopus 로고
    • Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth
    • SM Beschnidt, JR Strub Evaluation of the marginal accuracy of different all-ceramic crown systems after simulation in the artificial mouth J Oral Rehabil 26 1999 582 593
    • (1999) J Oral Rehabil , vol.26 , pp. 582-593
    • Beschnidt, S.M.1    Strub, J.R.2
  • 34
    • 0141721827 scopus 로고    scopus 로고
    • Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns
    • T Nakamura, N Dei, T Kojima, K Wakabayashi Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns Int J Prosthodont 16 2003 244 248
    • (2003) Int J Prosthodont , vol.16 , pp. 244-248
    • Nakamura, T.1    Dei, N.2    Kojima, T.3    Wakabayashi, K.4
  • 35
    • 15944372291 scopus 로고    scopus 로고
    • Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems
    • MC Balkaya, A Cinar, S Pamuk Influence of firing cycles on the margin distortion of 3 all-ceramic crown systems J Prosthet Dent 93 2005 346 355
    • (2005) J Prosthet Dent , vol.93 , pp. 346-355
    • Balkaya, M.C.1    Cinar, A.2    Pamuk, S.3
  • 37
    • 46249120193 scopus 로고    scopus 로고
    • Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems
    • KB Lee, CW Park, KH Kim, TY Kwon Marginal and internal fit of all-ceramic crowns fabricated with two different CAD/CAM systems Dent Mater J 27 2008 422 426
    • (2008) Dent Mater J , vol.27 , pp. 422-426
    • Lee, K.B.1    Park, C.W.2    Kim, K.H.3    Kwon, T.Y.4
  • 38
    • 0035409693 scopus 로고    scopus 로고
    • Marginal fit of alumina- and zirconia-based fixed partial dentures produced by a CAD/CAM system
    • J Tinschert, G Natt, W Mautsch, H Spiekermann, KJ Anusavice Marginal fit of alumina- and zirconia-based fixed partial dentures produced by a CAD/CAM system Oper Dent 26 2001 367 374
    • (2001) Oper Dent , vol.26 , pp. 367-374
    • Tinschert, J.1    Natt, G.2    Mautsch, W.3    Spiekermann, H.4    Anusavice, K.J.5
  • 39
    • 17844402484 scopus 로고    scopus 로고
    • Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems
    • S Reich, M Wichmann, E Nkenke, P Proeschel Clinical fit of all-ceramic three-unit fixed partial dentures, generated with three different CAD/CAM systems Eur J Oral Sci 113 2005 174 179
    • (2005) Eur J Oral Sci , vol.113 , pp. 174-179
    • Reich, S.1    Wichmann, M.2    Nkenke, E.3    Proeschel, P.4
  • 41
    • 62849105654 scopus 로고    scopus 로고
    • Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses
    • W Att, F Komine, T Gerds, JR Strub Marginal adaptation of three different zirconium dioxide three-unit fixed dental prostheses J Prosthet Dent 101 2009 239 247
    • (2009) J Prosthet Dent , vol.101 , pp. 239-247
    • Att, W.1    Komine, F.2    Gerds, T.3    Strub, J.R.4
  • 43
    • 57349196555 scopus 로고    scopus 로고
    • Marginal and internal fits of fixed dental prostheses zirconia retainers
    • F Beuer, H Aggstaller, D Edelhoff, W Gernet, J Sorensen Marginal and internal fits of fixed dental prostheses zirconia retainers Dent Mater 25 2009 94 102
    • (2009) Dent Mater , vol.25 , pp. 94-102
    • Beuer, F.1    Aggstaller, H.2    Edelhoff, D.3    Gernet, W.4    Sorensen, J.5
  • 44
    • 69549084939 scopus 로고    scopus 로고
    • Influence of CAM vs. CAD/CAM scanning methods and finish line of tooth preparation in the vertical misfit of zirconia bridge structures
    • R Castillo de Oyagüe, MI Sánchez-Jorge, A Sánchez Turrión, F Monticelli, M Toledano, R Osorio Influence of CAM vs. CAD/CAM scanning methods and finish line of tooth preparation in the vertical misfit of zirconia bridge structures Am J Dent 22 2009 79 83
    • (2009) Am J Dent , vol.22 , pp. 79-83
    • Castillo De Oyagüe, R.1    Sánchez-Jorge, M.I.2    Sánchez Turrión, A.3    Monticelli, F.4    Toledano, M.5    Osorio, R.6
  • 45
    • 65149089178 scopus 로고    scopus 로고
    • Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems
    • P Kohorst, H Brinkmann, J Li, L Borchers, M Stiesch Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems Eur J Oral Sci 117 2009 319 325
    • (2009) Eur J Oral Sci , vol.117 , pp. 319-325
    • Kohorst, P.1    Brinkmann, H.2    Li, J.3    Borchers, L.4    Stiesch, M.5
  • 46
    • 72049130266 scopus 로고    scopus 로고
    • A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation
    • E Gonzalo, MJ Suárez, B Serrano, JF Lozano A comparison of the marginal vertical discrepancies of zirconium and metal ceramic posterior fixed dental prostheses before and after cementation J Prosthet Dent 102 2009 378 384
    • (2009) J Prosthet Dent , vol.102 , pp. 378-384
    • Gonzalo, E.1    Suárez, M.J.2    Serrano, B.3    Lozano, J.F.4
  • 47
    • 0029377487 scopus 로고
    • The accuracy of a high precision digitizer for CAD/CAM of crowns
    • M Persson, M Andersson, B Bergman The accuracy of a high precision digitizer for CAD/CAM of crowns J Prosthet Dent 74 1995 223 229
    • (1995) J Prosthet Dent , vol.74 , pp. 223-229
    • Persson, M.1    Andersson, M.2    Bergman, B.3
  • 48
    • 0030208224 scopus 로고    scopus 로고
    • Accuracy of machine milling and spark erosion with a CAD/CAM system
    • M Andersson, L Carlsson, M Persson, B Bergman Accuracy of machine milling and spark erosion with a CAD/CAM system J Prosthet Dent 76 1996 187 193
    • (1996) J Prosthet Dent , vol.76 , pp. 187-193
    • Andersson, M.1    Carlsson, L.2    Persson, M.3    Bergman, B.4
  • 49
    • 0035295530 scopus 로고    scopus 로고
    • Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations
    • RG Luthardt, O Sandkuhl, V Herold, MH Walter Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations Int J Prosthodont 14 2001 146 151
    • (2001) Int J Prosthodont , vol.14 , pp. 146-151
    • Luthardt, R.G.1    Sandkuhl, O.2    Herold, V.3    Walter, M.H.4
  • 50
    • 33644920407 scopus 로고    scopus 로고
    • A three-dimensional evaluation of a laser scanner and a touch-probe scanner
    • A Persson, M Andersson, A Oden, G Sandborgh-Englund A three-dimensional evaluation of a laser scanner and a touch-probe scanner J Prosthet Dent 95 2006 194 200
    • (2006) J Prosthet Dent , vol.95 , pp. 194-200
    • Persson, A.1    Andersson, M.2    Oden, A.3    Sandborgh-Englund, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.