메뉴 건너뛰기




Volumn 38, Issue 6, 2014, Pages 808-814

Evaluation of IAUGC indices and two DCE-MRI pharmacokinetic parameters assessed by two different theoretical algorithms in patients with brain tumors

Author keywords

Brain tumors; Brain blood barrier permeability; DCE MRI; Extended tofts kety model; IAUGC

Indexed keywords

ALGORITHMS; BLOOD; BRAIN; CURVE FITTING; PARAMETER ESTIMATION; PHARMACOKINETICS; TUMORS;

EID: 84927690670     PISSN: 08997071     EISSN: 18734499     Source Type: Journal    
DOI: 10.1016/j.clinimag.2014.07.008     Document Type: Article
Times cited : (5)

References (54)
  • 1
    • 0002170252 scopus 로고    scopus 로고
    • Cerebrospinal fluid: blood-brain barrier, brain edema, and hydrocephalus
    • Elsevier, New York
    • Rowland LP, Fink ME, Rubin L Cerebrospinal fluid: blood-brain barrier, brain edema, and hydrocephalus. Principles of neural science 2001, 1050-1060. Elsevier, New York. 3rd ed.
    • (2001) Principles of neural science , pp. 1050-1060
    • Rowland, L.P.1    Fink, M.E.2    Rubin, L.3
  • 2
    • 0035881307 scopus 로고    scopus 로고
    • Hypoxia and acidosis independently up-regulate vascular endothelial growth factor transcription in brain tumors in vivo
    • Fukumura D, Xu L, Chen Y, Gohongi T, Seed B, Jain RK Hypoxia and acidosis independently up-regulate vascular endothelial growth factor transcription in brain tumors in vivo. Cancer Res 2001, 61:6020-6024.
    • (2001) Cancer Res , vol.61 , pp. 6020-6024
    • Fukumura, D.1    Xu, L.2    Chen, Y.3    Gohongi, T.4    Seed, B.5    Jain, R.K.6
  • 3
    • 0028025011 scopus 로고
    • Vascular permeability and microcirculation of gliomas and mammary carcinomas transplanted in rat and mouse cranial windows
    • Yuan F, Salehi HA, Boucher Y, Vasthare US, Tuma RF, Jain RK Vascular permeability and microcirculation of gliomas and mammary carcinomas transplanted in rat and mouse cranial windows. Cancer Res 1994, 54:4564-4568.
    • (1994) Cancer Res , vol.54 , pp. 4564-4568
    • Yuan, F.1    Salehi, H.A.2    Boucher, Y.3    Vasthare, U.S.4    Tuma, R.F.5    Jain, R.K.6
  • 6
    • 0015400075 scopus 로고
    • Microvascular abnormalities in virally-induced canine brain tumors. Structural bases for altered blood-brain barrier function
    • Vick NA, Bigner DD Microvascular abnormalities in virally-induced canine brain tumors. Structural bases for altered blood-brain barrier function. J Neurol Sci 1972, 17:29-39.
    • (1972) J Neurol Sci , vol.17 , pp. 29-39
    • Vick, N.A.1    Bigner, D.D.2
  • 7
    • 0016913630 scopus 로고
    • Vasculature of neural neoplasms
    • Waggener JD, Beggs JL Vasculature of neural neoplasms. Adv Neurol 1976, 15:27-49.
    • (1976) Adv Neurol , vol.15 , pp. 27-49
    • Waggener, J.D.1    Beggs, J.L.2
  • 9
    • 84863053936 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced magnetic resonance imaging-derived kep as a potential biomarker of matrix metalloproteinase 9 expression in patients with glioblastoma multiforme: a pilot study
    • Awasthi R, Pandey CM, Sahoo P, Behari S, Kumar V, Kumar S, Misra S, Husain N, Soni P, Rathore RK, Gupta RK Dynamic contrast-enhanced magnetic resonance imaging-derived kep as a potential biomarker of matrix metalloproteinase 9 expression in patients with glioblastoma multiforme: a pilot study. J Comput Assist Tomogr 2012, 36:125-130.
    • (2012) J Comput Assist Tomogr , vol.36 , pp. 125-130
    • Awasthi, R.1    Pandey, C.M.2    Sahoo, P.3    Behari, S.4    Kumar, V.5    Kumar, S.6    Misra, S.7    Husain, N.8    Soni, P.9    Rathore, R.K.10    Gupta, R.K.11
  • 10
    • 51449124024 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced (DCE) derived transfer coefficient (ktrans) is a surrogate marker of matrix metalloproteinase 9 (MMP-9) expression in brain tuberculomas
    • Haris M, Husain N, Singh A, Awasthi R, Singh Rathore RK, Husain M, Gupta RK Dynamic contrast-enhanced (DCE) derived transfer coefficient (ktrans) is a surrogate marker of matrix metalloproteinase 9 (MMP-9) expression in brain tuberculomas. J Magn Reson Imaging 2008, 28:588-597.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 588-597
    • Haris, M.1    Husain, N.2    Singh, A.3    Awasthi, R.4    Singh Rathore, R.K.5    Husain, M.6    Gupta, R.K.7
  • 14
    • 0031404162 scopus 로고    scopus 로고
    • Modeling tracer kinetics in dynamic Gd-DTPA MR imaging
    • Tofts PS Modeling tracer kinetics in dynamic Gd-DTPA MR imaging. J Magn Reson Imaging 1997, 7:91-101.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 91-101
    • Tofts, P.S.1
  • 15
    • 0036191012 scopus 로고    scopus 로고
    • Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI
    • Buckley DL Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI. Magn Reson Med 2002, 47:601-606.
    • (2002) Magn Reson Med , vol.47 , pp. 601-606
    • Buckley, D.L.1
  • 16
    • 84906264372 scopus 로고    scopus 로고
    • Measurement of blood-brain barrier permeability with T1-weighted dynamic contrast-enhanced MRI in brain tumors: a comparative study with two different algorithms
    • [6 pages]
    • Bergamino M, Saitta L, Barletta L, Bonzano L, Mancardi GL, Castellan L, Ravetti JL, Roccatagliata L Measurement of blood-brain barrier permeability with T1-weighted dynamic contrast-enhanced MRI in brain tumors: a comparative study with two different algorithms. ISRN Neurosci 2013, 2013. [6 pages].
    • (2013) ISRN Neurosci , vol.2013
    • Bergamino, M.1    Saitta, L.2    Barletta, L.3    Bonzano, L.4    Mancardi, G.L.5    Castellan, L.6    Ravetti, J.L.7    Roccatagliata, L.8
  • 17
    • 78649570019 scopus 로고    scopus 로고
    • Temporal resolution and SNR requirements for accurate DCE-MRI data analysis using the AATH model
    • Kershaw LE, Cheng HL Temporal resolution and SNR requirements for accurate DCE-MRI data analysis using the AATH model. Magn Reson Med 2010, 64:1772-1780.
    • (2010) Magn Reson Med , vol.64 , pp. 1772-1780
    • Kershaw, L.E.1    Cheng, H.L.2
  • 18
    • 70449411152 scopus 로고    scopus 로고
    • Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla
    • Larsson HB, Courivaud F, Rostrup E, Hansen AE Measurement of brain perfusion, blood volume, and blood-brain barrier permeability, using dynamic contrast-enhanced T(1)-weighted MRI at 3 tesla. Magn Reson Med 2009, 62:1270-1281.
    • (2009) Magn Reson Med , vol.62 , pp. 1270-1281
    • Larsson, H.B.1    Courivaud, F.2    Rostrup, E.3    Hansen, A.E.4
  • 21
    • 79954613339 scopus 로고    scopus 로고
    • Validity of perfusion parameters obtained using the modified Tofts model: a simulation study
    • Luypaert R, Sourbron S, de Mey J Validity of perfusion parameters obtained using the modified Tofts model: a simulation study. Magn Reson Med 2011, 65:1491-1497.
    • (2011) Magn Reson Med , vol.65 , pp. 1491-1497
    • Luypaert, R.1    Sourbron, S.2    de Mey, J.3
  • 23
    • 0026011540 scopus 로고
    • Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts
    • Tofts PS, Kermode AG Measurement of the blood-brain barrier permeability and leakage space using dynamic MR imaging. 1. Fundamental concepts. Magn Reson Med 1991, 17:357-367.
    • (1991) Magn Reson Med , vol.17 , pp. 357-367
    • Tofts, P.S.1    Kermode, A.G.2
  • 26
    • 33745821729 scopus 로고    scopus 로고
    • Evaluation of response to treatment using DCE-MRI: the relationship between initial area under the gadolinium curve (IAUGC) and quantitative pharmacokinetic analysis
    • Walker-Samuel S, Leach MO, Collins DJ Evaluation of response to treatment using DCE-MRI: the relationship between initial area under the gadolinium curve (IAUGC) and quantitative pharmacokinetic analysis. Phys Med Biol 2006, 51:3593-3602.
    • (2006) Phys Med Biol , vol.51 , pp. 3593-3602
    • Walker-Samuel, S.1    Leach, M.O.2    Collins, D.J.3
  • 27
    • 84876066947 scopus 로고    scopus 로고
    • Quantitative dynamic contrast-enhanced MRI of pelvic and lumbar bone marrow: effect of age and marrow fat content on pharmacokinetic parameter values
    • Breault SR, Heye T, Bashir MR, Dale BM, Merkle EM, Reiner CS, Faridi KF, Gupta RT Quantitative dynamic contrast-enhanced MRI of pelvic and lumbar bone marrow: effect of age and marrow fat content on pharmacokinetic parameter values. AJR Am J Roentgenol 2013, 200:W297-W303.
    • (2013) AJR Am J Roentgenol , vol.200 , pp. W297-W303
    • Breault, S.R.1    Heye, T.2    Bashir, M.R.3    Dale, B.M.4    Merkle, E.M.5    Reiner, C.S.6    Faridi, K.F.7    Gupta, R.T.8
  • 28
    • 77951588482 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced magnetic resonance imaging of canine brain tumors
    • Zhao Q, Lee S, Kent M, Schatzberg S, Platt S Dynamic contrast-enhanced magnetic resonance imaging of canine brain tumors. Vet Radiol Ultrasound 2010, 51:122-129.
    • (2010) Vet Radiol Ultrasound , vol.51 , pp. 122-129
    • Zhao, Q.1    Lee, S.2    Kent, M.3    Schatzberg, S.4    Platt, S.5
  • 30
    • 27644512708 scopus 로고    scopus 로고
    • Quantitative measurement of leakage volume and permeability in gliomas, meningiomas and brain metastases with dynamic contrast-enhanced MRI
    • Ludemann L, Grieger W, Wurm R, Wust P, Zimmer C Quantitative measurement of leakage volume and permeability in gliomas, meningiomas and brain metastases with dynamic contrast-enhanced MRI. Magn Reson Imaging 2005, 23:833-841.
    • (2005) Magn Reson Imaging , vol.23 , pp. 833-841
    • Ludemann, L.1    Grieger, W.2    Wurm, R.3    Wust, P.4    Zimmer, C.5
  • 31
    • 27944439436 scopus 로고    scopus 로고
    • Differentiation of low-grade oligodendrogliomas from low-grade astrocytomas by using quantitative blood-volume measurements derived from dynamic susceptibility contrast-enhanced MR imaging
    • Cha S, Tihan T, Crawford F, Fischbein NJ, Chang S, Bollen A, Nelson SJ, Prados M, Berger MS, Dillon WP Differentiation of low-grade oligodendrogliomas from low-grade astrocytomas by using quantitative blood-volume measurements derived from dynamic susceptibility contrast-enhanced MR imaging. AJNR Am J Neuroradiol 2005, 26:266-273.
    • (2005) AJNR Am J Neuroradiol , vol.26 , pp. 266-273
    • Cha, S.1    Tihan, T.2    Crawford, F.3    Fischbein, N.J.4    Chang, S.5    Bollen, A.6    Nelson, S.J.7    Prados, M.8    Berger, M.S.9    Dillon, W.P.10
  • 32
    • 34249912894 scopus 로고    scopus 로고
    • High cerebral blood volume in human gliomas predicts deletion of chromosome 1p: preliminary results of molecular studies in gliomas with elevated perfusion
    • Law M, Brodsky JE, Babb J, Rosenblum M, Miller DC, Zagzag D, Gruber ML, Johnson G High cerebral blood volume in human gliomas predicts deletion of chromosome 1p: preliminary results of molecular studies in gliomas with elevated perfusion. J Magn Reson Imaging 2007, 25:1113-1119.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 1113-1119
    • Law, M.1    Brodsky, J.E.2    Babb, J.3    Rosenblum, M.4    Miller, D.C.5    Zagzag, D.6    Gruber, M.L.7    Johnson, G.8
  • 33
    • 33645665698 scopus 로고    scopus 로고
    • Comparative study into the robustness of compartmental modeling and model-free analysis in DCE-MRI studies
    • Roberts C, Issa B, Stone A, Jackson A, Waterton JC, Parker GJ Comparative study into the robustness of compartmental modeling and model-free analysis in DCE-MRI studies. J Magn Reson Imaging 2006, 23:554-563.
    • (2006) J Magn Reson Imaging , vol.23 , pp. 554-563
    • Roberts, C.1    Issa, B.2    Stone, A.3    Jackson, A.4    Waterton, J.C.5    Parker, G.J.6
  • 34
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state
    • Deoni SC, Rutt BK, Peters TM Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003, 49:515-526.
    • (2003) Magn Reson Med , vol.49 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 35
    • 0033766487 scopus 로고    scopus 로고
    • Gd-DTPA relaxivity depends on macromolecular content
    • Stanisz GJ, Henkelman RM Gd-DTPA relaxivity depends on macromolecular content. Magn Reson Med 2000, 44:665-667.
    • (2000) Magn Reson Med , vol.44 , pp. 665-667
    • Stanisz, G.J.1    Henkelman, R.M.2
  • 36
    • 0021727964 scopus 로고
    • Pharmacokinetics of GdDTPA/dimeglumine after intravenous injection into healthy volunteers
    • Weinmann HJ, Laniado M, Mutzel W Pharmacokinetics of GdDTPA/dimeglumine after intravenous injection into healthy volunteers. Physiol Chem Phys Med NMR 1984, 16:167-172.
    • (1984) Physiol Chem Phys Med NMR , vol.16 , pp. 167-172
    • Weinmann, H.J.1    Laniado, M.2    Mutzel, W.3
  • 40
    • 82455162480 scopus 로고    scopus 로고
    • Alterations in the blood brain barrier in ageing cerebral cortex in relationship to Alzheimer-type pathology: a study in the MRC-CFAS population neuropathology cohort
    • Viggars AP, Wharton SB, Simpson JE, Matthews FE, Brayne C, Savva GM, Garwood C, Drew D, Shaw PJ, Ince PG Alterations in the blood brain barrier in ageing cerebral cortex in relationship to Alzheimer-type pathology: a study in the MRC-CFAS population neuropathology cohort. Neurosci Lett 2011, 505:25-30.
    • (2011) Neurosci Lett , vol.505 , pp. 25-30
    • Viggars, A.P.1    Wharton, S.B.2    Simpson, J.E.3    Matthews, F.E.4    Brayne, C.5    Savva, G.M.6    Garwood, C.7    Drew, D.8    Shaw, P.J.9    Ince, P.G.10
  • 41
    • 0036199430 scopus 로고    scopus 로고
    • Reproducibility of quantitative dynamic MRI of normal human tissues
    • Padhani AR, Hayes C, Landau S, Leach MO Reproducibility of quantitative dynamic MRI of normal human tissues. NMR Biomed 2002, 15:143-153.
    • (2002) NMR Biomed , vol.15 , pp. 143-153
    • Padhani, A.R.1    Hayes, C.2    Landau, S.3    Leach, M.O.4
  • 42
    • 47849090992 scopus 로고    scopus 로고
    • Quantitative imaging biomarkers in the clinical development of targeted therapeutics: current and future perspectives
    • O'Connor JP, Jackson A, Asselin MC, Buckley DL, Parker GJ, Jayson GC Quantitative imaging biomarkers in the clinical development of targeted therapeutics: current and future perspectives. Lancet Oncol 2008, 9:766-776.
    • (2008) Lancet Oncol , vol.9 , pp. 766-776
    • O'Connor, J.P.1    Jackson, A.2    Asselin, M.C.3    Buckley, D.L.4    Parker, G.J.5    Jayson, G.C.6
  • 44
    • 0032853898 scopus 로고    scopus 로고
    • Key factors in the acquisition of contrast kinetic data for oncology
    • Evelhoch JL Key factors in the acquisition of contrast kinetic data for oncology. J Magn Reson Imaging 1999, 10:254-259.
    • (1999) J Magn Reson Imaging , vol.10 , pp. 254-259
    • Evelhoch, J.L.1
  • 52
    • 7044269882 scopus 로고    scopus 로고
    • Prostate cancer: evaluation of vascular characteristics with dynamic contrast-enhanced T1-weighted MR imaging-initial experience
    • Buckley DL, Roberts C, Parker GJ, Logue JP, Hutchinson CE Prostate cancer: evaluation of vascular characteristics with dynamic contrast-enhanced T1-weighted MR imaging-initial experience. Radiology 2004, 233:709-715.
    • (2004) Radiology , vol.233 , pp. 709-715
    • Buckley, D.L.1    Roberts, C.2    Parker, G.J.3    Logue, J.P.4    Hutchinson, C.E.5
  • 54
    • 0342298515 scopus 로고    scopus 로고
    • Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors
    • Li KL, Zhu XP, Waterton J, Jackson A Improved 3D quantitative mapping of blood volume and endothelial permeability in brain tumors. J Magn Reson Imaging 2000, 12:347-357.
    • (2000) J Magn Reson Imaging , vol.12 , pp. 347-357
    • Li, K.L.1    Zhu, X.P.2    Waterton, J.3    Jackson, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.