메뉴 건너뛰기




Volumn 80, Issue 12, 2014, Pages 1320-1335

Thromboelastometry for guiding bleeding management of the critically ill patient: A systematic review of the literature

Author keywords

Blood coagulation; Blood transfusion; Hemostasis; Liver transplantation; Point of care systems; Thromboelastography

Indexed keywords

FIBRINOGEN CONCENTRATE; FRESH FROZEN PLASMA; PROTHROMBIN COMPLEX;

EID: 84925458658     PISSN: 03759393     EISSN: 18271596     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (63)

References (92)
  • 1
    • 55449102909 scopus 로고    scopus 로고
    • Early aggressive use of fresh frozen plasma does not improve outcome in critically injured trauma patients
    • Scalea TM, Bochicchio KM, Lumpkins K, Hess JR, Dutton R, Pyle A et al. Early aggressive use of fresh frozen plasma does not improve outcome in critically injured trauma patients. Ann Surg 2008;248:578-84.
    • (2008) Ann Surg , vol.248 , pp. 578-584
    • Scalea, T.M.1    Bochicchio, K.M.2    Lumpkins, K.3    Hess, J.R.4    Dutton, R.5    Pyle, A.6
  • 2
    • 67649233456 scopus 로고    scopus 로고
    • Postinjury life threatening coagulopathy: Is 1:1 fresh frozen plasma: Packed red blood cells the answer?
    • discussion 270-1
    • Kashuk JL, Moore EE, Johnson JL, Haenel J, Wilson M, Moore JB et al. Postinjury life threatening coagulopathy: is 1:1 fresh frozen plasma: packed red blood cells the answer? J Trauma 2008;65:261-70; discussion 270-1.
    • (2008) J Trauma , vol.65 , pp. 261-270
    • Kashuk, J.L.1    Moore, E.E.2    Johnson, J.L.3    Haenel, J.4    Wilson, M.5    Moore, J.B.6
  • 3
    • 67651146608 scopus 로고    scopus 로고
    • The relationship of blood product ratio to mortality: Survival benefit or survival bias?
    • discussion 362-4
    • Snyder CW, Weinberg JA, McGwin G, Jr., Melton SM, George RL, Reiff DA et al. The relationship of blood product ratio to mortality: survival benefit or survival bias? J Trauma 2009;66:358-62; discussion 362-4.
    • (2009) J Trauma , vol.66 , pp. 358-362
    • Snyder, C.W.1    Weinberg, J.A.2    McGwin, G.3    Melton, S.M.4    George, R.L.5    Reiff, D.A.6
  • 4
    • 36549084598 scopus 로고    scopus 로고
    • Increased mortality, postoperative morbidity, and cost after red blood cell transfusion in patients having cardiac surgery
    • Murphy GJ, Reeves BC, Rogers CA, Rizvi SI, Culliford L, Angelini GD. Increased mortality, postoperative morbidity, and cost after red blood cell transfusion in patients having cardiac surgery. Circulation 2007;116:2544-52.
    • (2007) Circulation , vol.116 , pp. 2544-2552
    • Murphy, G.J.1    Reeves, B.C.2    Rogers, C.A.3    Rizvi, S.I.4    Culliford, L.5    Angelini, G.D.6
  • 5
    • 79251604754 scopus 로고    scopus 로고
    • Association between intraoperative blood transfusion and mortality and morbidity in patients undergoing noncardiac surgery
    • Glance LG, Dick AW, Mukamel DB, Fleming FJ, Zollo RA, Wissler R et al. Association between intraoperative blood transfusion and mortality and morbidity in patients undergoing noncardiac surgery. Anesthesiology 2011;114:283-92.
    • (2011) Anesthesiology , vol.114 , pp. 283-292
    • Glance, L.G.1    Dick, A.W.2    Mukamel, D.B.3    Fleming, F.J.4    Zollo, R.A.5    Wissler, R.6
  • 6
    • 3342939227 scopus 로고    scopus 로고
    • Platelet transfusions during coronary artery bypass graft surgery are associated with serious adverse outcomes
    • Spiess BD, Royston D, Levy JH, Fitch J, Dietrich W, Body S et al. Platelet transfusions during coronary artery bypass graft surgery are associated with serious adverse outcomes. Transfusion (Paris) 2004;44:1143-8.
    • (2004) Transfusion (Paris) , vol.44 , pp. 1143-1148
    • Spiess, B.D.1    Royston, D.2    Levy, J.H.3    Fitch, J.4    Dietrich, W.5    Body, S.6
  • 7
    • 27944501478 scopus 로고    scopus 로고
    • Fresh frozen plasma transfusion in critically ill medical patients with coagulopathy
    • Dara SI, Rana R, Afessa B, Moore SB, Gajic O. Fresh frozen plasma transfusion in critically ill medical patients with coagulopathy. Crit Care Med 2005;33:2667-71.
    • (2005) Crit Care Med , vol.33 , pp. 2667-2671
    • Dara, S.I.1    Rana, R.2    Afessa, B.3    Moore, S.B.4    Gajic, O.5
  • 8
    • 34248587906 scopus 로고    scopus 로고
    • Fresh-frozen plasma and platelet transfusions are associated with development of acute lung injury in critically ill medical patients
    • Khan H, Belsher J, Yilmaz M, Afessa B, Winters JL, Moore SB et al. Fresh-frozen plasma and platelet transfusions are associated with development of acute lung injury in critically ill medical patients. Chest 2007;131:1308-14.
    • (2007) Chest , vol.131 , pp. 1308-1314
    • Khan, H.1    Belsher, J.2    Yilmaz, M.3    Afessa, B.4    Winters, J.L.5    Moore, S.B.6
  • 9
    • 41649106022 scopus 로고    scopus 로고
    • Transfusion of fresh frozen plasma in critically ill surgical patients is associated with an increased risk of infection
    • Sarani B, Dunkman WJ, Dean L, Sonnad S, Rohrbach JI, Gracias VH. Transfusion of fresh frozen plasma in critically ill surgical patients is associated with an increased risk of infection. Crit Care Med 2008;36:1114-8.
    • (2008) Crit Care Med , vol.36 , pp. 1114-1118
    • Sarani, B.1    Dunkman, W.J.2    Dean, L.3    Sonnad, S.4    Rohrbach, J.I.5    Gracias, V.H.6
  • 11
    • 84859097986 scopus 로고    scopus 로고
    • Comparison of whole blood fibrin-based clot tests in thrombelastography and thromboelastometry
    • Solomon C, Sorensen B, Hochleitner G, Kashuk J, Ranucci M, Schochl H. Comparison of whole blood fibrin-based clot tests in thrombelastography and thromboelastometry. Anesth Analg 2012;114:721-30.
    • (2012) Anesth Analg , vol.114 , pp. 721-730
    • Solomon, C.1    Sorensen, B.2    Hochleitner, G.3    Kashuk, J.4    Ranucci, M.5    Schochl, H.6
  • 12
    • 77955096119 scopus 로고    scopus 로고
    • An assessment of clinical interchangeability of TEG and RoTEM thromboelastographic variables in cardiac surgical patients
    • Venema LF, Post WJ, Hendriks HG, Huet RC, De Wolf JT, De Vries AJ. An assessment of clinical interchangeability of TEG and RoTEM thromboelastographic variables in cardiac surgical patients. Anesth Analg 2010;111:339-44.
    • (2010) Anesth Analg , vol.111 , pp. 339-344
    • Venema, L.F.1    Post, W.J.2    Hendriks, H.G.3    Huet, R.C.4    De Wolf, J.T.5    De Vries, A.J.6
  • 14
    • 84876296413 scopus 로고    scopus 로고
    • Early thromboelastometric variables reliably predict maximum clot firmness in patients undergoing cardiac surgery: A step towards earlier decision making
    • Dirkmann D, Gorlinger K, Dusse F, Kottenberg E, Peters J. Early thromboelastometric variables reliably predict maximum clot firmness in patients undergoing cardiac surgery: a step towards earlier decision making. Acta Anaesthesiol Scand 2013;57:594-603.
    • (2013) Acta Anaesthesiol Scand , vol.57 , pp. 594-603
    • Dirkmann, D.1    Gorlinger, K.2    Dusse, F.3    Kottenberg, E.4    Peters, J.5
  • 15
    • 84872732533 scopus 로고    scopus 로고
    • Fast interpretation of thromboelastometry in non-cardiac surgery: Reliability in patients with hypo-, normo-, and hypercoagulability
    • Gorlinger K, Dirkmann D, Solomon C, Hanke AA. Fast interpretation of thromboelastometry in non-cardiac surgery: reliability in patients with hypo-, normo-, and hypercoagulability. Br J Anaesth 2013;110:222-30.
    • (2013) Br J Anaesth , vol.110 , pp. 222-230
    • Gorlinger, K.1    Dirkmann, D.2    Solomon, C.3    Hanke, A.A.4
  • 16
    • 84892777228 scopus 로고    scopus 로고
    • Fiveminute parameter of thromboelastometry is sufficient to detect thrombocytopenia and hypofibrinogenaemia in patients undergoing liver transplantation
    • Song JG, Jeong SM, Jun. IG, Lee HM, Hwang GS. Fiveminute parameter of thromboelastometry is sufficient to detect thrombocytopenia and hypofibrinogenaemia in patients undergoing liver transplantation. Br J Anaesth 2014;112:290-7.
    • (2014) Br J Anaesth , vol.112 , pp. 290-297
    • Song, J.G.1    Jeong, S.M.2    Jun, I.G.3    Lee, H.M.4    Hwang, G.S.5
  • 17
    • 38849186575 scopus 로고    scopus 로고
    • Rotational thrombelastometry for the bedside monitoring of recombinant hirudin
    • Sucker C, Zotz RB, Gorlinger K, Hartmann M. Rotational thrombelastometry for the bedside monitoring of recombinant hirudin. Acta Anaesthesiol Scand 2008;52:358-62.
    • (2008) Acta Anaesthesiol Scand , vol.52 , pp. 358-362
    • Sucker, C.1    Zotz, R.B.2    Gorlinger, K.3    Hartmann, M.4
  • 18
    • 84884806057 scopus 로고    scopus 로고
    • Ecarin modified rotational thrombelastometry: A point-of-care applicable alternative to monitor the direct thrombin inhibitor argatroban
    • Schaden E, Schober A, Hacker S, Kozek-Langenecker S. Ecarin modified rotational thrombelastometry: a point-of-care applicable alternative to monitor the direct thrombin inhibitor argatroban. Wien Klin Wochenschr 2013;125:156-9.
    • (2013) Wien Klin Wochenschr , vol.125 , pp. 156-159
    • Schaden, E.1    Schober, A.2    Hacker, S.3    Kozek-Langenecker, S.4
  • 19
    • 84862857278 scopus 로고    scopus 로고
    • Reproducibility of thrombelastometry (ROTEM (R)): Point-of-care versus hospital laboratory performance
    • Haas T, Spielmann N, Mauch J, Speer O, Schmugge M, Weiss M. Reproducibility of thrombelastometry (ROTEM (R)): point-of-care versus hospital laboratory performance. Scand J Clin Lab Invest 2012;72:313-7.
    • (2012) Scand J Clin Lab Invest , vol.72 , pp. 313-317
    • Haas, T.1    Spielmann, N.2    Mauch, J.3    Speer, O.4    Schmugge, M.5    Weiss, M.6
  • 20
    • 79959556145 scopus 로고    scopus 로고
    • Laboratory-based ROTEM ((R)) analysis: Implementing pneumatic tube transport and real-time graphic transmission
    • Colucci G, Giabbani E, Barizzi G, Urwyler N, Alberio L. Laboratory-based ROTEM ((R)) analysis: implementing pneumatic tube transport and real-time graphic transmission. Int J Lab Hematol 2011;33:441-6.
    • (2011) Int J Lab Hematol , vol.33 , pp. 441-446
    • Colucci, G.1    Giabbani, E.2    Barizzi, G.3    Urwyler, N.4    Alberio, L.5
  • 21
    • 84866343890 scopus 로고    scopus 로고
    • Alterations in rotation thromboelastometry (ROTEM (R)) parameters: Point-of-care testing vs analysis after pneumatic tube system transport
    • Martin J, Schuster T, Moessmer G, Kochs EF, Wagner KJ. Alterations in rotation thromboelastometry (ROTEM (R)) parameters: point-of-care testing vs analysis after pneumatic tube system transport. Br J Anaesth 2012;109:540-5.
    • (2012) Br J Anaesth , vol.109 , pp. 540-545
    • Martin, J.1    Schuster, T.2    Moessmer, G.3    Kochs, E.F.4    Wagner, K.J.5
  • 22
    • 84929328231 scopus 로고    scopus 로고
    • A comparison of interindividual variability between thromboelastography (TEG) and rotational thromboelastometry (ROTEM): Preliminary data
    • Anderson L, Dick K, Smith R, Macfie A, Grant A, Clark A et al. A comparison of interindividual variability between thromboelastography (TEG) and rotational thromboelastometry (ROTEM): preliminary data. Appl Cardiopulmon Pathophysiol 2013;17:200-1.
    • (2013) Appl Cardiopulmon Pathophysiol , vol.17 , pp. 200-201
    • Anderson, L.1    Dick, K.2    Smith, R.3    Macfie, A.4    Grant, A.5    Clark, A.6
  • 24
    • 84875260163 scopus 로고    scopus 로고
    • Impact of changes in haematocrit level and platelet count on thromboelastometry parameters
    • Nagler M, Kathriner S, Bachmann LM, Wuillemin WA. Impact of changes in haematocrit level and platelet count on thromboelastometry parameters. Thromb Res 2013;131:249-53.
    • (2013) Thromb Res , vol.131 , pp. 249-253
    • Nagler, M.1    Kathriner, S.2    Bachmann, L.M.3    Wuillemin, W.A.4
  • 26
    • 84862985254 scopus 로고    scopus 로고
    • The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry
    • Ogawa S, Szlam F, Bolliger D, Nishimura T, Chen EP, Tanaka KA. The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry. Anesth Analg 2012;115:16-21.
    • (2012) Anesth Analg , vol.115 , pp. 16-21
    • Ogawa, S.1    Szlam, F.2    Bolliger, D.3    Nishimura, T.4    Chen, E.P.5    Tanaka, K.A.6
  • 27
    • 78649994796 scopus 로고    scopus 로고
    • Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders
    • Fenger-Eriksen C, Moore GW, Rangarajan S, Ingerslev J, Sorensen B. Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders. Transfusion (Paris) 2010;50:2571-6.
    • (2010) Transfusion (Paris) , vol.50 , pp. 2571-2576
    • Fenger-Eriksen, C.1    Moore, G.W.2    Rangarajan, S.3    Ingerslev, J.4    Sorensen, B.5
  • 28
    • 48949119068 scopus 로고    scopus 로고
    • Low plasma fibrinogen levels with the Clauss method during anticoagulation with bivalirudin
    • Molinaro RJ, Szlam F, Levy JH, Fantz CR, Tanaka KA. Low plasma fibrinogen levels with the Clauss method during anticoagulation with bivalirudin. Anesthesiology 2008;109:160-1.
    • (2008) Anesthesiology , vol.109 , pp. 160-161
    • Molinaro, R.J.1    Szlam, F.2    Levy, J.H.3    Fantz, C.R.4    Tanaka, K.A.5
  • 31
    • 34247568437 scopus 로고    scopus 로고
    • Acute traumatic coagulopathy: Initiated by hypoperfusion: Modulated through the protein C pathway?
    • Brohi K, Cohen MJ, Ganter MT, Matthay MA, Mackersie RC, Pittet JF. Acute traumatic coagulopathy: initiated by hypoperfusion: modulated through the protein C pathway? Ann Surg 2007;245:812-8.
    • (2007) Ann Surg , vol.245 , pp. 812-818
    • Brohi, K.1    Cohen, M.J.2    Ganter, M.T.3    Matthay, M.A.4    Mackersie, R.C.5    Pittet, J.F.6
  • 32
    • 35848943443 scopus 로고    scopus 로고
    • Acute coagulopathy of trauma: Mechanism, identification and effect
    • Brohi K, Cohen MJ, Davenport RA. Acute coagulopathy of trauma: mechanism, identification and effect. Curr Opin Crit Care 2007;13:680-5.
    • (2007) Curr Opin Crit Care , vol.13 , pp. 680-685
    • Brohi, K.1    Cohen, M.J.2    Davenport, R.A.3
  • 34
    • 68049142042 scopus 로고    scopus 로고
    • Time for changing coagulation management in trauma-related massive bleeding
    • Fries D, Innerhofer P, Schobersberger W. Time for changing coagulation management in trauma-related massive bleeding. Curr Opin Anaesthesiol 2009;22:267-74.
    • (2009) Curr Opin Anaesthesiol , vol.22 , pp. 267-274
    • Fries, D.1    Innerhofer, P.2    Schobersberger, W.3
  • 35
    • 84877048396 scopus 로고    scopus 로고
    • Rotational thrombolelastometry produces potentially clinical useful results within 10 min in bleeding Emergency Department patients: The DEUCE study
    • Reed MJ, Nimmo AF, McGee D, Manson L, Neffendorf AE, Moir L et al. Rotational thrombolelastometry produces potentially clinical useful results within 10 min in bleeding Emergency Department patients: the DEUCE study. Eur J Emerg Med 2013;20:160-6.
    • (2013) Eur J Emerg Med , vol.20 , pp. 160-166
    • Reed, M.J.1    Nimmo, A.F.2    McGee, D.3    Manson, L.4    Neffendorf, A.E.5    Moir, L.6
  • 36
    • 84859735736 scopus 로고    scopus 로고
    • Coagulation monitoring of the bleeding traumatized patient
    • Johansson PI. Coagulation monitoring of the bleeding traumatized patient. Curr Opin Anaesthesiol 2012;25:235-41.
    • (2012) Curr Opin Anaesthesiol , vol.25 , pp. 235-241
    • Johansson, P.I.1
  • 37
    • 77950681467 scopus 로고    scopus 로고
    • Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate
    • Schochl H, Nienaber U, Hofer G, Voelckel W, Jambor C, Scharbert G et al. Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate. Crit Care 2010;14:R55.
    • (2010) Crit Care , vol.14 , pp. R55
    • Schochl, H.1    Nienaber, U.2    Hofer, G.3    Voelckel, W.4    Jambor, C.5    Scharbert, G.6
  • 38
    • 79952197748 scopus 로고    scopus 로고
    • Transfusion in trauma: Thromboelastometry-guided coagulation factor concentrate-based therapy versus standard fresh frozen plasma-based therapy
    • Schochl H, Nienaber U, Maegele M, Hochleicner G, Primavesi F, Steitz B et al. Transfusion in trauma: thromboelastometry-guided coagulation factor concentrate-based therapy versus standard fresh frozen plasma-based therapy. Crit Care 2011;15:R83.
    • (2011) Crit Care , vol.15 , pp. R83
    • Schochl, H.1    Nienaber, U.2    Maegele, M.3    Hochleicner, G.4    Primavesi, F.5    Steitz, B.6
  • 39
    • 79958044332 scopus 로고    scopus 로고
    • The impact of fresh frozen plasma vs coagulation factor concentrates on morbidity and mortality in trauma-associated haemorrhage and massive transfusion
    • Nienaber U, Innerhofer P, Westermann I, Schochl H, Attal R, Breitkopf R et al. The impact of fresh frozen plasma vs coagulation factor concentrates on morbidity and mortality in trauma-associated haemorrhage and massive transfusion. Injury 2011;42:697-701.
    • (2011) Injury , vol.42 , pp. 697-701
    • Nienaber, U.1    Innerhofer, P.2    Westermann, I.3    Schochl, H.4    Attal, R.5    Breitkopf, R.6
  • 40
    • 84859894923 scopus 로고    scopus 로고
    • Reduction of fresh frozen plasma requirements by perioperative point-of-care coagulation management with early calculated goal-directed therapy
    • Gorlinger K, Fries D, Dirkmann D, Weber CF, Hanke AA, Schochl H. Reduction of fresh frozen plasma requirements by perioperative point-of-care coagulation management with early calculated goal-directed therapy. Transfus Med Hemother 2012;39:104-13.
    • (2012) Transfus Med Hemother , vol.39 , pp. 104-113
    • Gorlinger, K.1    Fries, D.2    Dirkmann, D.3    Weber, C.F.4    Hanke, A.A.5    Schochl, H.6
  • 41
    • 84865251063 scopus 로고    scopus 로고
    • Perioperative treatment algorithm for bleeding burn patients reduces allogeneic blood product requirements
    • Schaden E, Kimberger O, Kraincuk P, Baron DM, Metnitz PG, Kozek-Langenecker S. Perioperative treatment algorithm for bleeding burn patients reduces allogeneic blood product requirements. Br J Anaesth 2012;109:376-81.
    • (2012) Br J Anaesth , vol.109 , pp. 376-381
    • Schaden, E.1    Kimberger, O.2    Kraincuk, P.3    Baron, D.M.4    Metnitz, P.G.5    Kozek-Langenecker, S.6
  • 42
    • 84863424619 scopus 로고    scopus 로고
    • Fibrinogen levels during trauma hemorrhage, response to replacement therapy, and association with patient outcomes
    • Rourke C, Curry N, Khan S, Taylor R, Raza I, Davenport R et al. Fibrinogen levels during trauma hemorrhage, response to replacement therapy, and association with patient outcomes. J Thromb Haemost 2012;10:1342-51.
    • (2012) J Thromb Haemost , vol.10 , pp. 1342-1351
    • Rourke, C.1    Curry, N.2    Khan, S.3    Taylor, R.4    Raza, I.5    Davenport, R.6
  • 44
    • 80055079344 scopus 로고    scopus 로고
    • Hyperfibrinolysis diagnosed by rotational thromboelastometry (ROTEM) is associated with higher mortality in patients with severe trauma
    • Theusinger OM, Wanner GA, Emmert MY, Billeter A, Eismon J, Seifert B et al. Hyperfibrinolysis diagnosed by rotational thromboelastometry (ROTEM) is associated with higher mortality in patients with severe trauma. Anesth Analg 2011;113:1003-12.
    • (2011) Anesth Analg , vol.113 , pp. 1003-1012
    • Theusinger, O.M.1    Wanner, G.A.2    Emmert, M.Y.3    Billeter, A.4    Eismon, J.5    Seifert, B.6
  • 45
    • 17144365499 scopus 로고    scopus 로고
    • Thrombelastography/thromboelastometry
    • Luddington RJ. Thrombelastography/thromboelastometry. Clin Lab Haematol 2005;27:81-90.
    • (2005) Clin Lab Haematol , vol.27 , pp. 81-90
    • Luddington, R.J.1
  • 47
    • 70350459505 scopus 로고    scopus 로고
    • Hyperfibrinolysis after major trauma: Differential diagnosis of lysis patterns and prognostic value of thrombelastometry
    • Schochl H, Frietsch T, Pavelka M, Jambor C. Hyperfibrinolysis after major trauma: differential diagnosis of lysis patterns and prognostic value of thrombelastometry. J Trauma 2009;67:125-31.
    • (2009) J Trauma , vol.67 , pp. 125-131
    • Schochl, H.1    Frietsch, T.2    Pavelka, M.3    Jambor, C.4
  • 48
    • 44649109632 scopus 로고    scopus 로고
    • Evaluation of rotation thrombelastography for the diagnosis of hyperfibrinolysis in trauma patients
    • Levrat A, Gros A, Rugeri L, Inaba K, Floccard B, Negrier C et al. Evaluation of rotation thrombelastography for the diagnosis of hyperfibrinolysis in trauma patients. Br J Anaesth 2008;100:792-7.
    • (2008) Br J Anaesth , vol.100 , pp. 792-797
    • Levrat, A.1    Gros, A.2    Rugeri, L.3    Inaba, K.4    Floccard, B.5    Negrier, C.6
  • 49
    • 33846423913 scopus 로고    scopus 로고
    • Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography
    • Rugeri L, Levrat A, David JS, Delecroix E, Floccard B, Gios A et al. Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography. J Thromb Haemost 2007;5:289-95.
    • (2007) J Thromb Haemost , vol.5 , pp. 289-295
    • Rugeri, L.1    Levrat, A.2    David, J.S.3    Delecroix, E.4    Floccard, B.5    Gios, A.6
  • 52
    • 84881161245 scopus 로고    scopus 로고
    • Diagnosis of perioperative coagulopathy-plasma versus whole blood testing
    • Tanaka KA, Bader SO, Sturgil EL. Diagnosis of Perioperative Coagulopathy-Plasma versus Whole Blood Testing. J Cardiothorac Vasc Anesth 2013;27:S9-S15
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. S9-S15
    • Tanaka, K.A.1    Bader, S.O.2    Sturgil, E.L.3
  • 54
    • 84874949613 scopus 로고    scopus 로고
    • Potential value of transfusion protocols in cardiac surgery
    • Gorlinger K, Dirkmann D, Hanke AA. Potential value of transfusion protocols in cardiac surgery. Curr Opin Anaesthesiol 2013;26:230-43.
    • (2013) Curr Opin Anaesthesiol , vol.26 , pp. 230-243
    • Gorlinger, K.1    Dirkmann, D.2    Hanke, A.A.3
  • 55
    • 84873433792 scopus 로고    scopus 로고
    • Earlier detection of coagulopathy with thromboelastometry during pediatric cardiac surgery: A prospective observational study
    • Romlin BS, Wahlander H, Synnergren M, Baghaei F, Jeppsson A. Earlier detection of coagulopathy with thromboelastometry during pediatric cardiac surgery: a prospective observational study. Paed Anaesth 2013;23:222-7.
    • (2013) Paed Anaesth , vol.23 , pp. 222-227
    • Romlin, B.S.1    Wahlander, H.2    Synnergren, M.3    Baghaei, F.4    Jeppsson, A.5
  • 56
    • 78650959437 scopus 로고    scopus 로고
    • Intraoperative thromboelastometry is associated with reduced transfusion prevalence in pediatric cardiac surgery
    • Romlin BS, Wahlander H, Berggren H, Synnergren M, Baghaei F, Nilsson K et al. Intraoperative thromboelastometry is associated with reduced transfusion prevalence in pediatric cardiac surgery. Anesth Analg 2011;112:30-6.
    • (2011) Anesth Analg , vol.112 , pp. 30-36
    • Romlin, B.S.1    Wahlander, H.2    Berggren, H.3    Synnergren, M.4    Baghaei, F.5    Nilsson, K.6
  • 58
    • 84865679729 scopus 로고    scopus 로고
    • Does rotational thromboelastometry (ROTEM) improve prediction of bleeding after cardiac surgery?
    • Lee GC, Kicza AM, Liu KY, Nyman CB, Kaufman RM, Body SC. Does rotational thromboelastometry (ROTEM) improve prediction of bleeding after cardiac surgery? Anesth Analg 2012;115:499-506.
    • (2012) Anesth Analg , vol.115 , pp. 499-506
    • Lee, G.C.1    Kicza, A.M.2    Liu, K.Y.3    Nyman, C.B.4    Kaufman, R.M.5    Body, S.C.6
  • 59
    • 79959942882 scopus 로고    scopus 로고
    • Correlations between global clotting function tests, duration of operation, and postoperative chest tube drainage in pediatric cardiac surgery
    • Hayashi T, Sakurai Y, Fukuda K, Yada K, Ogiwara K, Matsumoto T et al. Correlations between global clotting function tests, duration of operation, and postoperative chest tube drainage in pediatric cardiac surgery. Paed Anaesth 2011;21:865-71.
    • (2011) Paed Anaesth , vol.21 , pp. 865-871
    • Hayashi, T.1    Sakurai, Y.2    Fukuda, K.3    Yada, K.4    Ogiwara, K.5    Matsumoto, T.6
  • 61
    • 80155135733 scopus 로고    scopus 로고
    • Can RoTEM (R) analysis be applied for haemostatic monitoring in paediatric congenital heart surgery?
    • Andreasen JB, Hvas AM, Christiansen K, Ravn HB. Can RoTEM (R) analysis be applied for haemostatic monitoring in paediatric congenital heart surgery? Cardiol Young 2011;21:684-91.
    • (2011) Cardiol Young , vol.21 , pp. 684-691
    • Andreasen, J.B.1    Hvas, A.M.2    Christiansen, K.3    Ravn, H.B.4
  • 62
    • 33644928315 scopus 로고    scopus 로고
    • An audit of red cell and blood product use after the institution of thromboelastometry in a cardiac intensive care unit
    • Anderson L, Quasim I, Soutar R, Steven M, Macfie A, Korte W. An audit of red cell and blood product use after the institution of thromboelastometry in a cardiac intensive care unit. Transfus Med 2006;16:31-9.
    • (2006) Transfus Med , vol.16 , pp. 31-39
    • Anderson, L.1    Quasim, I.2    Soutar, R.3    Steven, M.4    Macfie, A.5    Korte, W.6
  • 63
    • 84888293444 scopus 로고    scopus 로고
    • Transfusion of allogeneic blood products in proximal aortic surgery with hypothermic circulatory arrest: Effect of thromboelastometry-guided transfusion management
    • Fassl J, Matt P, Eckstein F, Filipovic M, Gregor M, Zenklusen U et al. Transfusion of allogeneic blood products in proximal aortic surgery with hypothermic circulatory arrest: effect of thromboelastometry-guided transfusion management. J Cardiothorac Vasc Anesth 2013:27:1181-8.
    • (2013) J Cardiothorac Vasc Anesth , vol.27 , pp. 1181-1188
    • Fassl, J.1    Matt, P.2    Eckstein, F.3    Filipovic, M.4    Gregor, M.5    Zenklusen, U.6
  • 64
    • 34248158874 scopus 로고    scopus 로고
    • Cost reduction of perioperative coagulation management in cardiac surgery: Value of "bedside" thrombelastography (ROTEM)
    • Spalding GJ, Hartrumpf M, Sierig T, Oesberg N, Kirschke CG, Aloes JM. Cost reduction of perioperative coagulation management in cardiac surgery: value of "bedside" thrombelastography (ROTEM). Eur J Cardiothorac Surg 2007;31:1052-7.
    • (2007) Eur J Cardiothorac Surg , vol.31 , pp. 1052-1057
    • Spalding, G.J.1    Hartrumpf, M.2    Sierig, T.3    Oesberg, N.4    Kirschke, C.G.5    Aloes, J.M.6
  • 66
    • 67649447204 scopus 로고    scopus 로고
    • Bleeding management with fibrinogen concentrate targeting a high-normal plasma fibrinogen level: A pilot study
    • Rahe-Meyer N, Pichlmaier M, Haverich A, Solomon C, Winterhalter M, Piepenbrock S et al. Bleeding management with fibrinogen concentrate targeting a high-normal plasma fibrinogen level: a pilot study. Br J Anaesth 2009:102:785-92.
    • (2009) Br J Anaesth , vol.102 , pp. 785-792
    • Rahe-Meyer, N.1    Pichlmaier, M.2    Haverich, A.3    Solomon, C.4    Winterhalter, M.5    Piepenbrock, S.6
  • 67
    • 68749106893 scopus 로고    scopus 로고
    • Thromboelastometry-guided administration of fibrinogen concentrate for the treatment of excessive intraoperative bleeding in thoracoabdominal aortic aneurysm surgery
    • Rahe-Meyer N, Solomon C, Winterhalter M, Piepenbrock S, Tanaka K, Haverich A et al. Thromboelastometry-guided administration of fibrinogen concentrate for the treatment of excessive intraoperative bleeding in thoracoabdominal aortic aneurysm surgery. J Thorac Cardiovasc Surg 2009;138:694-702.
    • (2009) J Thorac Cardiovasc Surg , vol.138 , pp. 694-702
    • Rahe-Meyer, N.1    Solomon, C.2    Winterhalter, M.3    Piepenbrock, S.4    Tanaka, K.5    Haverich, A.6
  • 68
    • 84859926185 scopus 로고    scopus 로고
    • Thromboelastometry based early goaldirected coagulation management reduces blood transfusion requirements, adverse events, and costs in acute type a aortic dissection: A pilot study
    • Hanke AA, Herald U, Dirkmann D, Tsagakis K, Jakob H, Gorlinger K. Thromboelastometry based early goaldirected coagulation management reduces blood transfusion requirements, adverse events, and costs in acute type a aortic dissection: a pilot study. Transfus Med Hemother 2012;39:121-8.
    • (2012) Transfus Med Hemother , vol.39 , pp. 121-128
    • Hanke, A.A.1    Herald, U.2    Dirkmann, D.3    Tsagakis, K.4    Jakob, H.5    Gorlinger, K.6
  • 69
    • 84871544047 scopus 로고    scopus 로고
    • Effects of fibrinogen concentrate as first-line therapy during major aortic replacement surgery: A randomized, placebo-controlled trial
    • Rahe-Meyer N, Solomon C, Hanke A, Schmidt DS, Knoerzer D, Hochleitner G et al. Effects of fibrinogen concentrate as first-line therapy during major aortic replacement surgery: a randomized, placebo-controlled trial. Anesthesiology 2013;118:40-50.
    • (2013) Anesthesiology , vol.118 , pp. 40-50
    • Rahe-Meyer, N.1    Solomon, C.2    Hanke, A.3    Schmidt, D.S.4    Knoerzer, D.5    Hochleitner, G.6
  • 70
    • 77957984493 scopus 로고    scopus 로고
    • Thromboelastometrically guided transfusion protocol during aortic surgery with circulatory arrest: A prospective, randomized trial
    • e2
    • Girdauskas E, Kempfert J, Kuntze T, Borger MA, Enders J, Fassl J et al. Thromboelastometrically guided transfusion protocol during aortic surgery with circulatory arrest: a prospective, randomized trial. J Thorac Cardiovasc Surg 2010;140:1117-24 e2.
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 1117-1124
    • Girdauskas, E.1    Kempfert, J.2    Kuntze, T.3    Borger, M.A.4    Enders, J.5    Fassl, J.6
  • 71
    • 81855194434 scopus 로고    scopus 로고
    • First-line therapy with coagulation factor concentrates combined with point-of-care coagulation testing is associated with decreased allogeneic blood transfusion in cardiovascular surgery: A retrospective, single-center cohort study
    • Gorlinger K, Dirkmann D, Hanke AA, Kamler M, Kottenberg E, Thielmann M et al. First-line therapy with coagulation factor concentrates combined with point-of-care coagulation testing is associated with decreased allogeneic blood transfusion in cardiovascular surgery: a retrospective, single-center cohort study. Anesthesiology 2011;115:1179-91
    • (2011) Anesthesiology , vol.115 , pp. 1179-1191
    • Gorlinger, K.1    Dirkmann, D.2    Hanke, A.A.3    Kamler, M.4    Kottenberg, E.5    Thielmann, M.6
  • 73
    • 33749055499 scopus 로고    scopus 로고
    • Coagulation management during liver transplantation
    • Gorlinger K. [Coagulation management during liver transplantation]. Hamostaseologie 2006;26:S64-76.
    • (2006) Hamostaseologie , vol.26 , pp. S64-S76
    • Gorlinger, K.1
  • 75
    • 84889673270 scopus 로고    scopus 로고
    • Delicate balance of bleeding and thrombosis in endstage liver disease and liver transplantation
    • Saner FH, Gieseler RK, Akiz H, Canbay A, Gorlinger K. Delicate balance of bleeding and thrombosis in endstage liver disease and liver transplantation. Digestion 2013;88:135-44.
    • (2013) Digestion , vol.88 , pp. 135-144
    • Saner, F.H.1    Gieseler, R.K.2    Akiz, H.3    Canbay, A.4    Gorlinger, K.5
  • 76
    • 71949096431 scopus 로고    scopus 로고
    • Monitoring of haemostasis in liver transplantation: Comparison of laboratory based and point of care tests
    • Herbstreit F, Winter EM, Peters J, Hartmann M. Monitoring of haemostasis in liver transplantation: comparison of laboratory based and point of care tests. Anaesthesia 2010;65:44-9.
    • (2010) Anaesthesia , vol.65 , pp. 44-49
    • Herbstreit, F.1    Winter, E.M.2    Peters, J.3    Hartmann, M.4
  • 77
    • 64649094825 scopus 로고    scopus 로고
    • The coagulopathy of cirrhosis assessed by thromboelastometry and its correlation with conventional coagulation parameters
    • Tripodi A, Primignani M, Chantarangkul V, Viscardi Y, Dell'Era A, Fabris FM et al. The coagulopathy of cirrhosis assessed by thromboelastometry and its correlation with conventional coagulation parameters. Thromb Res 2009;124:132-6.
    • (2009) Thromb Res , vol.124 , pp. 132-136
    • Tripodi, A.1    Primignani, M.2    Chantarangkul, V.3    Viscardi, Y.4    Dell'Era, A.5    Fabris, F.M.6
  • 78
    • 33746378665 scopus 로고    scopus 로고
    • Transfusion triggers in orthotopic liver transplantation: A comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests
    • Coakley M, Reddy K, Mackie I, Mallett S. Transfusion triggers in orthotopic liver transplantation: a comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests. J Cardiothorac Vasc Anesth 2006;20:548-53.
    • (2006) J Cardiothorac Vasc Anesth , vol.20 , pp. 548-553
    • Coakley, M.1    Reddy, K.2    Mackie, I.3    Mallett, S.4
  • 79
    • 84865746474 scopus 로고    scopus 로고
    • An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation
    • Blasi A, Beltran J, Pereira A, Martinez-Palli G, Torrents A, Balust J et al. An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation. Transfusion (Paris) 2012;52:1989-98.
    • (2012) Transfusion (Paris) , vol.52 , pp. 1989-1998
    • Blasi, A.1    Beltran, J.2    Pereira, A.3    Martinez-Palli, G.4    Torrents, A.5    Balust, J.6
  • 80
    • 77949413099 scopus 로고    scopus 로고
    • Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation
    • Roullet S, Pillot J, Freyburger G, Biais M, Quinart A, Rault A et al. Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation. Br J Anaesth 2010;104:422-8.
    • (2010) Br J Anaesth , vol.104 , pp. 422-428
    • Roullet, S.1    Pillot, J.2    Freyburger, G.3    Biais, M.4    Quinart, A.5    Rault, A.6
  • 81
    • 79960471698 scopus 로고    scopus 로고
    • Correlation between rotation thrombelastometry ROTEM analysis and standard haemostatic parameters during liver transplantation
    • Stancheva A, Spassov L, Tzatchev K. Correlation between rotation thrombelastometry ROTEM analysis and standard haemostatic parameters during liver transplantation. Clin Lab 2011;57:407-13.
    • (2011) Clin Lab , vol.57 , pp. 407-413
    • Stancheva, A.1    Spassov, L.2    Tzatchev, K.3
  • 82
    • 79953329138 scopus 로고    scopus 로고
    • Thrombelastometry-based perioperative coagulation management in visceral surgery and liver transplantation: Experience of 10 years and 1105 LTX
    • Gorlinger K, Dirkmann D, Mueller-Beissenhirtz H, Paul A, Hartmann M, Saner F. Thrombelastometry-based perioperative coagulation management in visceral surgery and liver transplantation: experience of 10 years and 1105 LTX. Liver Transpl 2010;16:S86.
    • (2010) Liver Transpl , vol.16 , pp. S86
    • Gorlinger, K.1    Dirkmann, D.2    Mueller-Beissenhirtz, H.3    Paul, A.4    Hartmann, M.5    Saner, F.6
  • 83
    • 77958598977 scopus 로고    scopus 로고
    • Introduction of fibrinogen in the treatment of hemostatic disorders during orthotopic liver transplantation: Implications in the use of allogenic blood
    • Noval-Padillo JA, Leon-Justel A, Mellado-Miras P, Porras-Lopez F, Villegas-Duque D, Gomez-Bravo MA et al. Introduction of fibrinogen in the treatment of hemostatic disorders during orthotopic liver transplantation: implications in the use of allogenic blood. Transplant Proc 2010;42:2973-4.
    • (2010) Transplant Proc , vol.42 , pp. 2973-2974
    • Noval-Padillo, J.A.1    Leon-Justel, A.2    Mellado-Miras, P.3    Porras-Lopez, F.4    Villegas-Duque, D.5    Gomez-Bravo, M.A.6
  • 84
    • 79953218118 scopus 로고    scopus 로고
    • The use of thromboelastometry in the assessment of hemostasis during orthotopic liver transplantation reduces the demand for blood products
    • Trzebicki J, Flakiewicz E, Kosieradzki M, Blaszczyk B, Kolacz M, Jureczko L et al. The use of thromboelastometry in the assessment of hemostasis during orthotopic liver transplantation reduces the demand for blood products. Ann Transplant 2010;15:19-24.
    • (2010) Ann Transplant , vol.15 , pp. 19-24
    • Trzebicki, J.1    Flakiewicz, E.2    Kosieradzki, M.3    Blaszczyk, B.4    Kolacz, M.5    Jureczko, L.6
  • 85
    • 84869459194 scopus 로고    scopus 로고
    • Haemostatic monitoring during postpartum haemorrhage and implications for management
    • Solomon C, Collis RE, Collins PW. Haemostatic monitoring during postpartum haemorrhage and implications for management. Br J Anaesth 2012;109:851-63.
    • (2012) Br J Anaesth , vol.109 , pp. 851-863
    • Solomon, C.1    Collis, R.E.2    Collins, P.W.3
  • 86
    • 84860000731 scopus 로고    scopus 로고
    • Postpartum hemorrhage: When uterotonics and sutures fail
    • James AH, McLintock C, Lockhart E. Postpartum hemorrhage: when uterotonics and sutures fail. Am J Hematol 2012;87(Suppl 1):S16-22.
    • (2012) Am J Hematol , vol.87 , pp. S16-S22
    • James, A.H.1    McLintock, C.2    Lockhart, E.3
  • 87
    • 33846455126 scopus 로고    scopus 로고
    • The decrease of fibrinogen is an early predictor of the severity of postpartum hemorrhage
    • Charbit B, Mandelbrot L, Samain E, Baron G, Haddaoui B, Keita H et al. The decrease of fibrinogen is an early predictor of the severity of postpartum hemorrhage. J Thromb Haemost 2007;5:266-73.
    • (2007) J Thromb Haemost , vol.5 , pp. 266-273
    • Charbit, B.1    Mandelbrot, L.2    Samain, E.3    Baron, G.4    Haddaoui, B.5    Keita, H.6
  • 88
    • 67651113784 scopus 로고    scopus 로고
    • Bedside assessment of fibrinogen level in postpartum haemorrhage by thrombelastometry
    • Huissoud C, Carrabin N, Audibert F, Levrat A, Massignon D, Berland M et al. Bedside assessment of fibrinogen level in postpartum haemorrhage by thrombelastometry. BJOG 2009;116:1097-102.
    • (2009) BJOG , vol.116 , pp. 1097-1102
    • Huissoud, C.1    Carrabin, N.2    Audibert, F.3    Levrat, A.4    Massignon, D.5    Berland, M.6
  • 89
    • 84864450589 scopus 로고    scopus 로고
    • Obstetric hemorrhage and coagulation: An update. Thromboelastography, thromboelastometry, and conventional coagulation tests in the diagnosis and prediction of postpartum hemorrhage
    • De Lange NM, Lance MD, De Groot R, Beckers EA, Henskens YM, Scheepers HC. Obstetric hemorrhage and coagulation: an update. Thromboelastography, thromboelastometry, and conventional coagulation tests in the diagnosis and prediction of postpartum hemorrhage. Obstet Gynecol Surv 2012;67:426-35.
    • (2012) Obstet Gynecol Surv , vol.67 , pp. 426-435
    • De Lange, N.M.1    Lance, M.D.2    De Groot, R.3    Beckers, E.A.4    Henskens, Y.M.5    Scheepers, H.C.6
  • 90
    • 33749070779 scopus 로고    scopus 로고
    • Haemorrhagic complications in obstetrics
    • Pfanner G, Kilgert K. [Haemorrhagic complications in obstetrics]. Hamostaseologie 2006;26:S56-63.
    • (2006) Hamostaseologie , vol.26 , pp. S56-S63
    • Pfanner, G.1    Kilgert, K.2
  • 92
    • 79951952372 scopus 로고    scopus 로고
    • GRADE guidelines: 1. Introduction-GRADE evidence profiles and summary of findings tables
    • Guyatt G, Oxman AD, Akl EA, Kunz R, Vist G, Brozek J et al. GRADE guidelines: 1. Introduction-GRADE evidence profiles and summary of findings tables. J Clin Epidemiol 2011;64:383-94.
    • (2011) J Clin Epidemiol , vol.64 , pp. 383-394
    • Guyatt, G.1    Oxman, A.D.2    Akl, E.A.3    Kunz, R.4    Vist, G.5    Brozek, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.