Volumn 110, Issue 2, 2013, Pages 222-230

Fast interpretation of thromboelastometry in non-cardiac surgery: Reliability in patients with hypo-, normo-, and hypercoagulability

Author keywords

blood coagulation; liver transplantation; measurement techniques; postpartum haemorrhage; thromboelastometry; trauma

Indexed keywords

AREA UNDER THE CURVE; ARTICLE; BLOOD CLOTTING; BLOOD CLOTTING TIME; BLOOD EXAMINATION; CORRELATION COEFFICIENT; HUMAN; HYPERCOAGULABILITY; HYPOCOAGULABILITY; PREDICTION; PRIORITY JOURNAL; RECEIVER OPERATING CHARACTERISTIC; RELIABILITY; RETROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; STATISTICAL SIGNIFICANCE; THROMBOELASTOMETRY;

EID: 84872732533     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aes374     Document Type: Article
Times cited : (134)

References (50)
  • 1
    • 62449333205 scopus 로고    scopus 로고
    • Point-of-Care versus central laboratory coagulation testing during haemorrhagic surgery A multicenter study
    • Toulon P, Ozier Y, Ankri A, Flé ron MH, Leroux G, Samama CM. Point-of-Care versus central laboratory coagulation testing during haemorrhagic surgery A multicenter study. Thromb Haemost 2009; 101: 394-401
    • (2009) Thromb Haemost , vol.101 , pp. 394-401
    • Toulon, P.1    Ozier, Y.2    Ankri, A.3    Fléron, M.H.4    Leroux, G.5    Samama, C.M.6
  • 2
    • 81855221942 scopus 로고    scopus 로고
    • Functional definition and characterization of acute traumatic coagulopathy
    • Davenport R, Manson J, De'Ath H, et al. Functional definition and characterization of acute traumatic coagulopathy. Crit Care Med 2011; 39: 2652-8
    • (2011) Crit Care Med , vol.39 , pp. 2652-2658
    • Davenport, R.1    Manson, J.2    De'Ath, H.3
  • 3
    • 84055197918 scopus 로고    scopus 로고
    • Comparison of thromboelastometry (ROTEMw) with standard plasmatic coagulation testing in paediatric surgery
    • Haas T, Spielmann N, Mauch J, et al. Comparison of thromboelastometry (ROTEMw) with standard plasmatic coagulation testing in paediatric surgery. Br J Anaesth 2012; 108: 36-41
    • (2012) Br J Anaesth , vol.108 , pp. 36-41
    • Haas, T.1    Spielmann, N.2    Mauch, J.3
  • 4
    • 84859735736 scopus 로고    scopus 로고
    • Coagulation monitoring of the bleeding traumatized patient
    • Johansson PI. Coagulation monitoring of the bleeding traumatized patient. Curr Opin Anaesthesiol 2012; 25: 235-41
    • (2012) Curr Opin Anaesthesiol , vol.25 , pp. 235-241
    • Johansson, P.I.1
  • 5
    • 77953088469 scopus 로고    scopus 로고
    • The effect of plasma transfusion on morbidity and mortality: A systematic review and meta-Analysis
    • Murad MH, Stubbs JR, Gandhi MJ, et al. The effect of plasma transfusion on morbidity and mortality: A systematic review and meta-Analysis. Transfusion 2010; 50: 1370-83
    • (2010) Transfusion , vol.50 , pp. 1370-1383
    • Murad, M.H.1    Stubbs, J.R.2    Gandhi, M.J.3
  • 6
    • 84859078843 scopus 로고    scopus 로고
    • Prevalence of survivor bias in observational studies on fresh frozen plasma:erythrocyte ratios in trauma requiring massive transfusion
    • Ho AM, Dion PW, Yeung JH, et al. Prevalence of survivor bias in observational studies on fresh frozen plasma:erythrocyte ratios in trauma requiring massive transfusion. Anesthesiology 2012; 116: 716-28
    • (2012) Anesthesiology , vol.116 , pp. 716-728
    • Ho, A.M.1    Dion, P.W.2    Yeung, J.H.3
  • 7
    • 84862728018 scopus 로고    scopus 로고
    • Coagulation management of bleeding trauma patients is changing in German trauma centers: An analysis from the trauma registry of the German Society for Trauma Surgery
    • Wafaisade A, Lefering R, Maegele M, et al. Coagulation management of bleeding trauma patients is changing in German trauma centers: An analysis from the trauma registry of the German Society for Trauma Surgery. J Trauma Acute Care Surg 2012; 72: 936-42
    • (2012) J Trauma Acute Care Surg , vol.72 , pp. 936-942
    • Wafaisade, A.1    Lefering, R.2    Maegele, M.3
  • 8
    • 69349101483 scopus 로고    scopus 로고
    • Fresh frozen plasma is independently associated with a higher risk of multiple organ failure and acute respiratory distress syndrome
    • Watson GA, Sperry JL, Rosengart MR, et al. Fresh frozen plasma is independently associated with a higher risk of multiple organ failure and acute respiratory distress syndrome. J Trauma 2009; 67: 221-30
    • (2009) J Trauma , vol.67 , pp. 221-230
    • Watson, G.A.1    Sperry, J.L.2    Rosengart, M.R.3
  • 9
    • 77958538106 scopus 로고    scopus 로고
    • Effect of blood products transfusion on the development of postinjury multiple organ failure
    • Johnson JL, Moore EE, Kashuk JL, et al. Effect of blood products transfusion on the development of postinjury multiple organ failure. Arch Surg 2010; 145: 973-7
    • (2010) Arch Surg , vol.145 , pp. 973-977
    • Johnson, J.L.1    Moore, E.E.2    Kashuk, J.L.3
  • 10
    • 77952541592 scopus 로고    scopus 로고
    • Impact of plasma transfusion in trauma patients who do not require massive transfusion
    • Inaba K, Branco BC, Rhee P, et al. Impact of plasma transfusion in trauma patients who do not require massive transfusion. J Am Coll Surg 2010; 210: 957-65
    • (2010) J Am Coll Surg , vol.210 , pp. 957-965
    • Inaba, K.1    Branco, B.C.2    Rhee, P.3
  • 11
    • 79958778284 scopus 로고    scopus 로고
    • The effect of FFP:RBC ratio on morbidity and mortality in trauma patients based on transfusion prediction score
    • Borgman MA, Spinella PC, Holcomb JB, et al. The effect of FFP:RBC ratio on morbidity and mortality in trauma patients based on transfusion prediction score. Vox Sang 2011; 101: 44-54
    • (2011) Vox Sang , vol.101 , pp. 44-54
    • Borgman, M.A.1    Spinella, P.C.2    Holcomb, J.B.3
  • 12
    • 78651354101 scopus 로고    scopus 로고
    • The use of freshfrozen plasma in England: High levels of inappropriate use in adults and children
    • Stanworth SJ, Grant-Casey J, Lowe D, et al. The use of freshfrozen plasma in England: High levels of inappropriate use in adults and children. Transfusion 2011; 51: 62-70
    • (2011) Transfusion , vol.51 , pp. 62-70
    • Stanworth, S.J.1    Grant-Casey, J.2    Lowe, D.3
  • 14
    • 79953328927 scopus 로고    scopus 로고
    • ROTEMbased algorithm for point-of-Care coagulation management in visceral surgery and liver transplantation: Experience of eight years and 829 LTX
    • Goerlinger K, Dirkmann D, Hanke A, Dusse F, Hartmann M. ROTEMbased algorithm for point-of-Care coagulation management in visceral surgery and liver transplantation: Experience of eight years and 829 LTX. Liver Transplant 2008; 14(Suppl. 1): S203-4
    • (2008) Liver Transplant , vol.14 , Issue.SUPPL. 1
    • Goerlinger, K.1    Dirkmann, D.2    Hanke, A.3    Dusse, F.4    Hartmann, M.5
  • 15
    • 67651113784 scopus 로고    scopus 로고
    • Bedside assessment of fibrinogen level in postpartum haemorrhage by thrombelastometry
    • Huissoud C, Carrabin N, Audibert F, et al. Bedside assessment of fibrinogen level in postpartum haemorrhage by thrombelastometry. BJOG 2009; 116: 1097-102
    • (2009) BJOG , vol.116 , pp. 1097-1102
    • Huissoud, C.1    Carrabin, N.2    Audibert, F.3
  • 16
    • 77949413099 scopus 로고    scopus 로고
    • Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation
    • Roullet S, Pillot J, Freyburger G, et al. Rotation thromboelastometry detects thrombocytopenia and hypofibrinogenaemia during orthotopic liver transplantation. Br J Anaesth 2010; 104: 422-8
    • (2010) Br J Anaesth , vol.104 , pp. 422-428
    • Roullet, S.1    Pillot, J.2    Freyburger, G.3
  • 17
    • 84856956489 scopus 로고    scopus 로고
    • FIBTEM provides early prediction of massive transfusion in trauma
    • Schöchl H, Cotton B, Inaba K, et al. FIBTEM provides early prediction of massive transfusion in trauma. Crit Care 2011; 15: R265
    • (2011) Crit Care , vol.15
    • Schöchl, H.1    Cotton, B.2    Inaba, K.3
  • 18
    • 84865746474 scopus 로고    scopus 로고
    • An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation
    • 10.1111/j.1537-2995.2011.03526.x. [Epub ahead of print
    • Blasi A, Beltran J, Pereira A, et al. An assessment of thromboelastometry to monitor blood coagulation and guide transfusion support in liver transplantation. Transfusion 2012, doi: 10.1111/j.1537-2995.2011.03526.x. [Epub ahead of print
    • Transfusion 2012
    • Blasi, A.1    Beltran, J.2    Pereira, A.3
  • 19
    • 84862857278 scopus 로고    scopus 로고
    • Reproducibility of thrombelastometry (ROTEMw): Point-of-Care versus hospital laboratory performance
    • Haas T, Spielmann N, Mauch J, Speer O, Schmugge M, Weiss M. Reproducibility of thrombelastometry (ROTEMw): Point-of-Care versus hospital laboratory performance. Scand J Clin Lab Invest 2012; 72: 313-7
    • (2012) Scand J Clin Lab Invest , vol.72 , pp. 313-317
    • Haas, T.1    Spielmann, N.2    Mauch, J.3    Speer, O.4    Schmugge, M.5    Weiss, M.6
  • 20
    • 79953329138 scopus 로고    scopus 로고
    • Thromboelastometry-based perioperative coagulation management in visceral surgery and liver transplantation: Experience of 10 years and 1105 LTX
    • Görlinger K, Dirkmann D, Müller-Beißenhirtz H, Paul A, Hartmann M, Saner F. Thromboelastometry-based perioperative coagulation management in visceral surgery and liver transplantation: Experience of 10 years and 1105 LTX. Liver Transplant 2010; 16(Suppl. 1): S86
    • (2010) Liver Transplant , vol.16 , Issue.SUPPL. 1
    • Görlinger, K.1    Dirkmann, D.2    Müller-Beißenhirtz, H.3    Paul, A.4    Hartmann, M.5    Saner, F.6
  • 21
    • 77954849876 scopus 로고    scopus 로고
    • Towards early individual goal-directed coagulation management in trauma patients
    • Spahn DR, Ganter MT. Towards early individual goal-directed coagulation management in trauma patients. Br J Anaesth 2010; 105: 103-5
    • (2010) Br J Anaesth , vol.105 , pp. 103-105
    • Spahn, D.R.1    Ganter, M.T.2
  • 22
    • 78049348696 scopus 로고    scopus 로고
    • Active, personalized, and balanced coagulation management saves lives in patients with massive bleeding
    • Ganter MT, Spahn DR. Active, personalized, and balanced coagulation management saves lives in patients with massive bleeding. Anesthesiology 2010; 113: 1016-8
    • (2010) Anesthesiology , vol.113 , pp. 1016-1018
    • Ganter, M.T.1    Spahn, D.R.2
  • 23
    • 77950681467 scopus 로고    scopus 로고
    • Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-Guided administration of fibrinogen concentrate and prothrombin complex concentrate
    • Schöchl H, Nienaber U, Hofer G, et al. Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-Guided administration of fibrinogen concentrate and prothrombin complex concentrate. Crit Care 2010; 14: R55
    • (2010) Crit Care , vol.14
    • Schöchl, H.1    Nienaber, U.2    Hofer, G.3
  • 24
    • 79952197748 scopus 로고    scopus 로고
    • Transfusion in trauma: Thromboelastometry-Guided coagulation factor concentratebased therapy versus standard fresh frozen plasma-based therapy
    • Schöchl H, Nienaber U, Maegele M, et al. Transfusion in trauma: Thromboelastometry-Guided coagulation factor concentratebased therapy versus standard fresh frozen plasma-based therapy. Crit Care 2011; 15: R83
    • (2011) Crit Care , vol.15
    • Schöchl, H.1    Nienaber, U.2    Maegele, M.3
  • 25
    • 79958044332 scopus 로고    scopus 로고
    • The impact of fresh frozen plasma vs coagulation factor concentrates on morbidity and mortality in trauma-Associated haemorrhage and massive transfusion
    • Nienaber U, Innerhofer P, Westermann I, et al. The impact of fresh frozen plasma vs coagulation factor concentrates on morbidity and mortality in trauma-Associated haemorrhage and massive transfusion. Injury 2011; 42: 697-701
    • (2011) Injury , vol.42 , pp. 697-701
    • Nienaber, U.1    Innerhofer, P.2    Westermann, I.3
  • 27
    • 81855194434 scopus 로고    scopus 로고
    • First-line therapy with coagulation factor concentrates combined with point-of-Care coagulation testing is associated with decreased allogeneic blood transfusion in cardiovascular surgery: A retrospective, single-Center cohort study
    • Görlinger K, Dirkmann D, Hanke AA, et al. First-line therapy with coagulation factor concentrates combined with point-of-Care coagulation testing is associated with decreased allogeneic blood transfusion in cardiovascular surgery: A retrospective, single-Center cohort study. Anesthesiology 2011; 115: 1179-91
    • (2011) Anesthesiology , vol.115 , pp. 1179-1191
    • Görlinger, K.1    Dirkmann, D.2    Hanke, A.A.3
  • 29
    • 84859894923 scopus 로고    scopus 로고
    • Reduction of fresh frozen plasma requirements by perioperative point-of-Care coagulation management with early calculated goal-directed therapy
    • Görlinger K, Fries D, Dirkmann D, Weber CF, Hanke AA, Schöchl H. Reduction of fresh frozen plasma requirements by perioperative point-of-Care coagulation management with early calculated goal-directed therapy. Transfus Med Hemother 2012; 39: 104-13
    • (2012) Transfus Med Hemother , vol.39 , pp. 104-113
    • Görlinger, K.1    Fries, D.2    Dirkmann, D.3    Weber, C.F.4    Hanke, A.A.5    Schöchl, H.6
  • 30
    • 84862889184 scopus 로고    scopus 로고
    • Point-of-Care testing: A prospective randomized clinical trial of efficacy in coagulopathic cardiac surgery patients
    • Weber CF, Görlinger K, Meininger D, et al. Point-of-Care testing: A prospective randomized clinical trial of efficacy in coagulopathic cardiac surgery patients. Anesthesiology 2012; 117: 531-47
    • (2012) Anesthesiology , vol.117 , pp. 531-547
    • Weber, C.F.1    Görlinger, K.2    Meininger, D.3
  • 33
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 8476: 307-10 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 34
    • 84655170265 scopus 로고    scopus 로고
    • Agreed statistics: Measurement method comparison
    • Bland JM, Altman DG. Agreed statistics: Measurement method comparison. Anesthesiology 2012; 116: 182-5
    • (2012) Anesthesiology , vol.116 , pp. 182-185
    • Bland, J.M.1    Altman, D.G.2
  • 35
    • 26044460461 scopus 로고    scopus 로고
    • The use of receiver operating characteristic curves in biomedical informatics
    • DOI 10.1016/j.jbi.2005.02.008, PII S1532046405000171
    • Lasko TA, Bhagwat JG, Zou KH, Ohno-Machado L. The use of receiver operating characteristic curves in biomedical informatics. J Biomed Inform 2005; 38: 404-15 (Pubitemid 41405811)
    • (2005) Journal of Biomedical Informatics , vol.38 , Issue.5 , pp. 404-415
    • Lasko, T.A.1    Bhagwat, J.G.2    Zou, K.H.3    Ohno-Machado, L.4
  • 36
    • 33846894344 scopus 로고    scopus 로고
    • Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models
    • DOI 10.1161/CIRCULATIONAHA.105.594929, PII 0000301720070206000016
    • Zou KH, O'Malley AJ, Mauri L. Receiver-operating characteristic analysis for evaluating diagnostic tests and predictive models. Circulation 2007; 115: 654-7 (Pubitemid 46226175)
    • (2007) Circulation , vol.115 , Issue.5 , pp. 654-657
    • Zou, K.H.1    O'Malley, A.J.2    Mauri, L.3
  • 37
    • 0025756234 scopus 로고
    • The area under the ROC curve and its competitors
    • Hilden J. The area under the ROC curve and its competitors. Med Decis Making 1991; 11: 95-101
    • (1991) Med Decis Making , vol.11 , pp. 95-101
    • Hilden, J.1
  • 38
    • 19044363528 scopus 로고    scopus 로고
    • The effects of platelet count on clot retraction and tissue plasminogen activator-induced fibrinolysis on thrombelastography
    • DOI 10.1213/01.ANE.0000149902.73689.64
    • Katori N, Tanaka KA, Szlam F, Levy JH. The effects of platelet count on clot retraction and tissue plasminogen activatorinduced fibrinolysis on thrombelastography. Anesth Analg 2005; 100: 1781-5 (Pubitemid 40712739)
    • (2005) Anesthesia and Analgesia , vol.100 , Issue.6 , pp. 1781-1785
    • Katori, N.1    Tanaka, K.A.2    Szlam, F.3    Levy, J.H.4
  • 39
    • 71949096431 scopus 로고    scopus 로고
    • Monitoring of haemostasis in liver transplantation: Comparison of laboratory based and point of care tests
    • Herbstreit F, Winter EM, Peters J, Hartmann M. Monitoring of haemostasis in liver transplantation: Comparison of laboratory based and point of care tests. Anaesthesia 2010; 65: 44-9
    • (2010) Anaesthesia , vol.65 , pp. 44-49
    • Herbstreit, F.1    Winter, E.M.2    Peters, J.3    Hartmann, M.4
  • 41
    • 52949133678 scopus 로고    scopus 로고
    • Plasma fibrinogen level, bleeding, and transfusion after on-Pump coronary artery bypass grafting surgery: A prospective observational study
    • Karlsson M, Ternström L, Hyllner M, Baghaei F, Nilsson S, Jeppsson A. Plasma fibrinogen level, bleeding, and transfusion after on-Pump coronary artery bypass grafting surgery: A prospective observational study. Transfusion 2008; 10: 2152-8
    • (2008) Transfusion , vol.10 , pp. 2152-2158
    • Karlsson, M.1    Ternström, L.2    Hyllner, M.3    Baghaei, F.4    Nilsson, S.5    Jeppsson, A.6
  • 42
    • 41849110247 scopus 로고    scopus 로고
    • The value of rotation thromboelastometry to monitor disturbed perioperative haemostasis and bleeding risk in patients with cardiopulmonary bypass
    • DOI 10.1097/MBC.0b013e3282f3f9d4, PII 0000172120080400000006
    • Reinhöfer M, Brauer M, Franke U, Bar D, Marx G, Lösche W. The value of rotation thromboelastometry to monitor disturbed perioperative haemostasis and bleeding risk in patients with cardiopulmonary bypass. Blood Coagul Fibrinolysis 2008; 19: 212-9 (Pubitemid 351498725)
    • (2008) Blood Coagulation and Fibrinolysis , vol.19 , Issue.3 , pp. 212-219
    • Reinhofer, M.1    Brauer, M.2    Franke, U.3    Barz, D.4    Marx, G.5    Losche, W.6
  • 43
    • 79953824677 scopus 로고    scopus 로고
    • Preoperative fibrinogen plasma concentration is associated with perioperative bleeding and transfusion requirements in scoliosis surgery
    • Carling MS, Jeppsson A, Wessberg P, Henriksson A, Baghaei F, Brisby H. Preoperative fibrinogen plasma concentration is associated with perioperative bleeding and transfusion requirements in scoliosis surgery. Spine 2011; 36: 549-55
    • (2011) Spine , vol.36 , pp. 549-555
    • Carling, M.S.1    Jeppsson, A.2    Wessberg, P.3    Henriksson, A.4    Baghaei, F.5    Brisby, H.6
  • 44
    • 65349156418 scopus 로고    scopus 로고
    • Fibrinogen substitution improves whole blood clot firmness after dilution with hydroxyethyl starch in bleeding patients undergoing radical cystectomy: A randomized, placebo-Controlled clinical trial
    • Fenger-Eriksen C, Jensen TM, Kristensen BS, et al. Fibrinogen substitution improves whole blood clot firmness after dilution with hydroxyethyl starch in bleeding patients undergoing radical cystectomy: A randomized, placebo-Controlled clinical trial. J Thromb Haemost 2009; 7: 795-802
    • (2009) J Thromb Haemost , vol.7 , pp. 795-802
    • Fenger-Eriksen, C.1    Jensen, T.M.2    Kristensen, B.S.3
  • 45
    • 78049340172 scopus 로고    scopus 로고
    • Pathophysiology and treatment of coagulopathy in massive hemorrhage and hemodilution
    • Bolliger D, Görlinger K, Tanaka KA. Pathophysiology and treatment of coagulopathy in massive hemorrhage and hemodilution. Anesthesiology 2010; 113: 1205-19
    • (2010) Anesthesiology , vol.113 , pp. 1205-1219
    • Bolliger, D.1    Görlinger, K.2    Tanaka, K.A.3
  • 46
    • 78649994796 scopus 로고    scopus 로고
    • Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders
    • Fenger-Eriksen C, Moore GW, Rangarajan S, Ingerslev J, Sørensen B. Fibrinogen estimates are influenced by methods of measurement and hemodilution with colloid plasma expanders. Transfusion 2010; 50: 2571-6
    • (2010) Transfusion , vol.50 , pp. 2571-2576
    • Fenger-Eriksen, C.1    Moore, G.W.2    Rangarajan, S.3    Ingerslev, J.4    Sørensen, B.5
  • 47
    • 57349165319 scopus 로고    scopus 로고
    • Peculiar whole blood rotation thromboelastometry (Rotem) profile in 40 sideropenic anaemia patients
    • Spiezia L, Radu C, Marchioro P, et al. Peculiar whole blood rotation thromboelastometry (Rotem) profile in 40 sideropenic anaemia patients. Thromb Haemostat 2008; 100: 1106-10
    • (2008) Thromb Haemostat , vol.100 , pp. 1106-1110
    • Spiezia, L.1    Radu, C.2    Marchioro, P.3
  • 48
    • 84862985254 scopus 로고    scopus 로고
    • The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry
    • Ogawa S, Szlam F, Bolliger D, Nishimura T, Chen EP, Tanaka KA. The impact of hematocrit on fibrin clot formation assessed by rotational thromboelastometry. Anesth Analg 2012; 115: 16-21
    • (2012) Anesth Analg , vol.115 , pp. 16-21
    • Ogawa, S.1    Szlam, F.2    Bolliger, D.3    Nishimura, T.4    Chen, E.P.5    Tanaka, K.A.6
  • 49
    • 84872167122 scopus 로고    scopus 로고
    • Effect of haematocrit on fibrin-based clot firmness in the FIBTEM assay
    • accepted for publication
    • Solomon C, Rahe-Meyer N, Schöchl H, Ranucci M, Görlinger K. Effect of haematocrit on fibrin-based clot firmness in the FIBTEM assay. Blood Transfus 2012; 10, accepted for publication
    • (2012) Blood Transfus , vol.10
    • Solomon, C.1    Rahe-Meyer, N.2    Schöchl, H.3    Ranucci, M.4    Görlinger, K.5
  • 50
    • 33746378665 scopus 로고    scopus 로고
    • Transfusion Triggers in Orthotopic Liver Transplantation: A Comparison of the Thromboelastometry Analyzer, the Thromboelastogram, and Conventional Coagulation Tests
    • DOI 10.1053/j.jvca.2006.01.016, PII S1053077006000036
    • Coakley M, Reddy K, Mackie I, Mallett S. Transfusion triggers in orthotopic liver transplantation: A comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests. J Cardiothorac Vasc Anesth 2006; 20: 548-53 (Pubitemid 44119274)
    • (2006) Journal of Cardiothoracic and Vascular Anesthesia , vol.20 , Issue.4 , pp. 548-553
    • Coakley, M.1    Reddy, K.2    Mackie, I.3    Mallett, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.