메뉴 건너뛰기




Volumn 65, Issue 1, 2010, Pages 44-49

Monitoring of haemostasis in liver transplantation: Comparison of laboratory based and point of care tests

Author keywords

[No Author keywords available]

Indexed keywords

FIBRINOGEN;

EID: 71949096431     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2009.06159.x     Document Type: Article
Times cited : (72)

References (15)
  • 2
    • 0035570399 scopus 로고    scopus 로고
    • Intraoperative blood losses and transfusion requirements during adult liver transplantation remain difficult to predict
    • Steib A, Freys G, Lehmann C, Meyer C, Mahoudeau G. Intraoperative blood losses and transfusion requirements during adult liver transplantation remain difficult to predict. Canadian Journal of Anesthesia 2001; 48: 1075-1079 (Pubitemid 34223642)
    • (2001) Canadian Journal of Anesthesia , vol.48 , Issue.11 , pp. 1075-1079
    • Steib, A.1    Freys, G.2    Lehmann, C.3    Meyer, C.4    Mahoudeau, G.5
  • 3
    • 38349184516 scopus 로고    scopus 로고
    • Intraoperative pulmonary embolism and intracardiac thrombosis complicating liver transplantation: A systematic review
    • Warnaar N, Molenaar IQ, Colquhoun SD, et al. Intraoperative pulmonary embolism and intracardiac thrombosis complicating liver transplantation: a systematic review. Journal of Thrombosis and Haemostasis 2008; 6: 297-302.
    • (2008) Journal of Thrombosis and Haemostasis , vol.6 , pp. 297-302
    • Warnaar, N.1    Molenaar, I.Q.2    Colquhoun, S.D.3
  • 4
    • 0031265843 scopus 로고    scopus 로고
    • Transfusion based on clinical coagulation monitoring does reduce hemorrhage during liver transplantation
    • Kang Y. Transfusion based on clinical coagulation monitoring does reduce hemorrhage during liver transplantation. Liver Transplantation Surgery 1997; 3: 655-659
    • (1997) Liver Transplantation Surgery , vol.3 , pp. 655-659
    • Kang, Y.1
  • 5
    • 33746378665 scopus 로고    scopus 로고
    • Transfusion Triggers in Orthotopic Liver Transplantation: A Comparison of the Thromboelastometry Analyzer, the Thromboelastogram, and Conventional Coagulation Tests
    • DOI 10.1053/j.jvca.2006.01.016, PII S1053077006000036
    • Coakley M, Reddy K, Mackie I, Mallett S. Transfusion triggers in orthotopic liver transplantation: a comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests. Journal of Cardiothoracic and Vascular Anesthesia 2006; 20: 548-553 (Pubitemid 44119274)
    • (2006) Journal of Cardiothoracic and Vascular Anesthesia , vol.20 , Issue.4 , pp. 548-553
    • Coakley, M.1    Reddy, K.2    Mackie, I.3    Mallett, S.4
  • 6
    • 46049118409 scopus 로고    scopus 로고
    • The prevalence of a hepatin-like effect shown on the thromboelastograph in patients undergoing liver transplantation
    • DOI 10.1002/lt.21437
    • Agarwal S, Senzolo M, Melikian C, Burroughs A, Mallett SV. The prevalence of a heparin-like effect shown on the thromboelastograph in patients undergoing liver transplantation. Liver Transplantation 2008; 14: 855-860 (Pubitemid 351895515)
    • (2008) Liver Transplantation , vol.14 , Issue.6 , pp. 855-860
    • Agarwal, S.1    Senzolo, M.2    Melikian, C.3    Burroughs, A.4    Mallett, S.V.5
  • 7
    • 0029586431 scopus 로고
    • Thromboelastography and liver transplantation
    • Gillies BS. Thromboelastography and liver transplantation. Seminars in Thrombosis and Hemostasis 1995; 21 (Suppl. 4): 45-49
    • (1995) Seminars in Thrombosis and Hemostasis , vol.21 , Issue.SUPPL. 4 , pp. 45-49
    • Gillies, B.S.1
  • 8
    • 79953328927 scopus 로고    scopus 로고
    • ROTEM-based algorithm for point-of-care coagulation management in visceral surgery and liver transplantation: Experience of eight years and 829 LTX
    • Görlinger K, Dirkmann D, Hanke A, Dusse F, Hartmann M. ROTEM-based algorithm for point-of-care coagulation management in visceral surgery and liver transplantation: experience of eight years and 829 LTX. Liver Transpantation 2008; 14 (Suppl. 1): LB-485.
    • (2008) Liver Transpantation , vol.14 , Issue.SUPPL. 1
    • Görlinger, K.1    Dirkmann, D.2    Hanke, A.3    Dusse, F.4    Hartmann, M.5
  • 9
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Statistical Methods in Medical Research 1999; 8: 135-160 (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 10
    • 57149118055 scopus 로고    scopus 로고
    • Rotational thromboelastography for monitoring of fibrinogen concentrate therapy in fibrinogen deficiency
    • Kalina U, Stöhr HA, Bickhard H, et al. Rotational thromboelastography for monitoring of fibrinogen concentrate therapy in fibrinogen deficiency. Blood Coagulation and Fibrinolysis 2008; 19: 777-783
    • (2008) Blood Coagulation and Fibrinolysis , vol.19 , pp. 777-783
    • Kalina, U.1    Stöhr, H.A.2    Bickhard, H.3
  • 11
    • 34247123272 scopus 로고    scopus 로고
    • Clinically significant differences between point-of-care analysers and a standard analyser for monitoring the International Normalized Ratio in oral anticoagulant therapy: A multi-instrument evaluation in a hospital outpatient setting
    • DOI 10.1097/MBC.0b013e328040c105, PII 0000172120070400000013
    • Moore GW, Henley A, Cotton SS, Tugnait S, Rangarajan S. Clinically significant differences between point-of-care analysers and a standard analyser for monitoring the International Normalized Ratio in oral anticoagulant therapy: a multi-instrument evaluation in a hospital outpatient setting. Blood Coagulation and Fibrinolysis 2007; 18: 287-292 (Pubitemid 46597404)
    • (2007) Blood Coagulation and Fibrinolysis , vol.18 , Issue.3 , pp. 287-292
    • Moore, G.W.1    Henley, A.2    Cotton, S.S.3    Tugnait, S.4    Rangarajan, S.5
  • 13
    • 61349100290 scopus 로고    scopus 로고
    • Quality assurance for point-of-care testing of oral anticoagulation: A large-scale evaluation of the Hemochron Junior Signature Microcoagulation System
    • Maddox JM, Bogo PH, McGregor E, Pippard MJ, Kerr R. Quality assurance for point-of-care testing of oral anticoagulation: a large-scale evaluation of the Hemochron Junior Signature Microcoagulation System. International Journal of Laboratory Hematology 2009; 31: 142-150
    • (2009) International Journal of Laboratory Hematology , vol.31 , pp. 142-150
    • Maddox, J.M.1    Bogo, P.H.2    McGregor, E.3    Pippard, M.J.4    Kerr, R.5
  • 14
    • 0037342739 scopus 로고    scopus 로고
    • Maintaining adequate anticoagulation on extracorporeal membrane oxygenation therapy: Hemochron junior low range versus hemochron 400
    • Colby CE, Sheehan A, Benitz W, Van Meurs K, Halamek LP, Moss RL. Maintaining adequate anticoagulation on extracorporeal membrane oxygenation therapy: hemochron junior low range versus hemochron 400. The Journal of Extracorporeal Technology 2003; 35: 35-38 (Pubitemid 36337277)
    • (2003) Journal of Extra-Corporeal Technology , vol.35 , Issue.1 , pp. 35-38
    • Colby, C.E.1    Sheehan, A.2    Benitz, W.3    Van Meurs, K.4    Halamek, L.P.5    Moss, R.L.6
  • 15
    • 0036145279 scopus 로고    scopus 로고
    • Monitoring high-dose heparin levels by ACT and HMT during extracorporeal circulation: Diagnostic accuracy of three compact monitors
    • DOI 10.1191/0267659102pf530oa
    • Giavarina D, Carta M, Fabbri A, Manfredi J, Gasparotto E, Soffiati G. Monitoring high-dose heparin levels by ACT and HMT during extracorporeal circulation: diagnostic accuracy of three compact monitors. Perfusion 2002; 17: 23-26 (Pubitemid 34071703)
    • (2002) Perfusion , vol.17 , Issue.1 , pp. 23-26
    • Giavarina, D.1    Carta, M.2    Fabbri, A.3    Manfredi, J.4    Gasparotto, E.5    Soffiati, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.