-
1
-
-
84893651437
-
Heart disease and stroke statistics-2014 update: A report from the American Heart Association
-
A.S. Go, D. Mozaffarian, V.L. Roger, E.J. Benjamin, J.D. Berry, and M.J. Blaha Heart disease and stroke statistics-2014 update: a report from the American Heart Association Circulation 129 2014 e28 e292
-
(2014)
Circulation
, vol.129
, pp. e28-e292
-
-
Go, A.S.1
Mozaffarian, D.2
Roger, V.L.3
Benjamin, E.J.4
Berry, J.D.5
Blaha, M.J.6
-
2
-
-
73349129701
-
Advanced heart failure treated with continuous-flow left ventricular assist device
-
M.S. Slaughter, J.G. Rogers, C.A. Milano, S.D. Russell, J.V. Conte, and D. Feldman Advanced heart failure treated with continuous-flow left ventricular assist device N Engl J Med 361 2009 2241 2251
-
(2009)
N Engl J Med
, vol.361
, pp. 2241-2251
-
-
Slaughter, M.S.1
Rogers, J.G.2
Milano, C.A.3
Russell, S.D.4
Conte, J.V.5
Feldman, D.6
-
3
-
-
33645074465
-
Improved durability of the HeartMate XVE left ventricular assist device provides safe mechanical support up to 1 year but is associated with high risk of device failure in the second year
-
J. Martin, O. Friesewinkel, C. Benk, S. Sorg, S. Schultz, and F. Beyersdorf Improved durability of the HeartMate XVE left ventricular assist device provides safe mechanical support up to 1 year but is associated with high risk of device failure in the second year J Heart Lung Transplant 25 2006 384 390
-
(2006)
J Heart Lung Transplant
, vol.25
, pp. 384-390
-
-
Martin, J.1
Friesewinkel, O.2
Benk, C.3
Sorg, S.4
Schultz, S.5
Beyersdorf, F.6
-
4
-
-
52049104955
-
Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy
-
R. John, F. Kamdar, K. Liao, M. Colvin-Adams, A. Boyle, and L. Joyce Improved survival and decreasing incidence of adverse events with the HeartMate II left ventricular assist device as bridge-to-transplant therapy Ann Thorac Surg 86 2008 1227 1235
-
(2008)
Ann Thorac Surg
, vol.86
, pp. 1227-1235
-
-
John, R.1
Kamdar, F.2
Liao, K.3
Colvin-Adams, M.4
Boyle, A.5
Joyce, L.6
-
5
-
-
84855585557
-
Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices
-
J. Suarez, C.B. Patel, G.M. Felker, R. Becker, A.F. Hernandez, and J.G. Rogers Mechanisms of bleeding and approach to patients with axial-flow left ventricular assist devices Circ Heart Fail 4 2011 779 784
-
(2011)
Circ Heart Fail
, vol.4
, pp. 779-784
-
-
Suarez, J.1
Patel, C.B.2
Felker, G.M.3
Becker, R.4
Hernandez, A.F.5
Rogers, J.G.6
-
6
-
-
84862542752
-
Bleeding and thrombosis in patients with continuous-flow ventricular assist devices
-
P.M. Eckman, and R. John Bleeding and thrombosis in patients with continuous-flow ventricular assist devices Circulation 125 2012 3038 3047
-
(2012)
Circulation
, vol.125
, pp. 3038-3047
-
-
Eckman, P.M.1
John, R.2
-
7
-
-
68949202239
-
Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: Analysis of outpatient anti-coagulation
-
A.J. Boyle, S.D. Russell, J.J. Teuteberg, M.S. Slaughter, N. Moazami, and F.D. Pagani Low thromboembolism and pump thrombosis with the HeartMate II left ventricular assist device: analysis of outpatient anti-coagulation J Heart Lung Transplant 28 2009 881 887
-
(2009)
J Heart Lung Transplant
, vol.28
, pp. 881-887
-
-
Boyle, A.J.1
Russell, S.D.2
Teuteberg, J.J.3
Slaughter, M.S.4
Moazami, N.5
Pagani, F.D.6
-
8
-
-
67650732055
-
High incidence of thromboembolic events in left ventricular assist device patients treated with recombinant activated factor VII
-
B.A. Bruckner, D.J. DiBardino, Q. Ning, A. Adeboygeun, K. Mahmoud, and J. Valdes High incidence of thromboembolic events in left ventricular assist device patients treated with recombinant activated factor VII J Heart Lung Transplant 28 2009 785 790
-
(2009)
J Heart Lung Transplant
, vol.28
, pp. 785-790
-
-
Bruckner, B.A.1
Dibardino, D.J.2
Ning, Q.3
Adeboygeun, A.4
Mahmoud, K.5
Valdes, J.6
-
9
-
-
56249139674
-
Low thromboembolic risk for patients with the Heartmate II left ventricular assist device
-
R. John, F. Kamdar, K. Liao, M. Colvin-Adams, L. Miller, and L. Joyce Low thromboembolic risk for patients with the Heartmate II left ventricular assist device J Thorac Cardiovasc Surg 136 2008 1318 1323
-
(2008)
J Thorac Cardiovasc Surg
, vol.136
, pp. 1318-1323
-
-
John, R.1
Kamdar, F.2
Liao, K.3
Colvin-Adams, M.4
Miller, L.5
Joyce, L.6
-
10
-
-
58249093243
-
Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
-
S. Crow, R. John, A. Boyle, S. Shumway, K. Liao, and M. Colvin-Adams Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices J Thorac Cardiovasc Surg 137 2009 208 215
-
(2009)
J Thorac Cardiovasc Surg
, vol.137
, pp. 208-215
-
-
Crow, S.1
John, R.2
Boyle, A.3
Shumway, S.4
Liao, K.5
Colvin-Adams, M.6
-
11
-
-
0034231930
-
Clinical experience with long-term use of implantable left ventricular assist devices: Indications, implantation, and outcomes
-
V. Kasirajan, P.M. McCarthy, K.J. Hoercher, R.C. Starling, J.B. Young, and M.K. Banbury Clinical experience with long-term use of implantable left ventricular assist devices: indications, implantation, and outcomes Semin Thorac Cardiovasc Surg 12 3 2000 229 237
-
(2000)
Semin Thorac Cardiovasc Surg
, vol.12
, Issue.3
, pp. 229-237
-
-
Kasirajan, V.1
McCarthy, P.M.2
Hoercher, K.J.3
Starling, R.C.4
Young, J.B.5
Banbury, M.K.6
-
12
-
-
84865246616
-
Pulsatile vs. Continuous flow in ventricular assist device therapy
-
G. Loor, and G. Gonzalez-Stawinski Pulsatile vs. continuous flow in ventricular assist device therapy Best Pract Res Clin Anaesthesiol 26 2 2012 105 115
-
(2012)
Best Pract Res Clin Anaesthesiol
, vol.26
, Issue.2
, pp. 105-115
-
-
Loor, G.1
Gonzalez-Stawinski, G.2
-
13
-
-
84894238579
-
Comparison of hemodynamics in the ascending aorta between pulsatile and continuous flow left ventricular assist devices using computational fluid dynamics based on computed tomography images
-
C. Karmonik, S. Partovi, B. Schmack, A. Weymann, M. Loebe, and G.P. Noon Comparison of hemodynamics in the ascending aorta between pulsatile and continuous flow left ventricular assist devices using computational fluid dynamics based on computed tomography images Artif Organs 38 2014 142 148
-
(2014)
Artif Organs
, vol.38
, pp. 142-148
-
-
Karmonik, C.1
Partovi, S.2
Schmack, B.3
Weymann, A.4
Loebe, M.5
Noon, G.P.6
-
14
-
-
33749011474
-
The hemodynamics of the Berlin pulsatile VAD and the role of its MHV configuration
-
I. Avrahami, M. Rosenfeld, and S. Einav The hemodynamics of the Berlin pulsatile VAD and the role of its MHV configuration Ann Biomed Eng 34 2006 1373 1388
-
(2006)
Ann Biomed Eng
, vol.34
, pp. 1373-1388
-
-
Avrahami, I.1
Rosenfeld, M.2
Einav, S.3
-
15
-
-
32644453420
-
Experimental fluid mechanics of pulsatile artificial blood pumps
-
S. Deutsch, J.M. Tarbell, K.B. Manning, G. Rosenberg, and A.A. Fontaine Experimental fluid mechanics of pulsatile artificial blood pumps Annu Rev Fluid Mech 38 2006 65 86
-
(2006)
Annu Rev Fluid Mech
, vol.38
, pp. 65-86
-
-
Deutsch, S.1
Tarbell, J.M.2
Manning, K.B.3
Rosenberg, G.4
Fontaine, A.A.5
-
16
-
-
84864848430
-
A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: Shear stress, exposure time and hemolysis index
-
K.H. Fraser, T. Zhang, M.E. Taskin, B.P. Griffith, and Z.J. Wu A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index J Biomech Eng 134 2012 081002
-
(2012)
J Biomech Eng
, vol.134
, pp. 081002
-
-
Fraser, K.H.1
Zhang, T.2
Taskin, M.E.3
Griffith, B.P.4
Wu, Z.J.5
-
17
-
-
77951264913
-
Increased incidence of gastrointestinal bleeding following implantation of the HeartMate II LVAD
-
D.R. Stern, J. Kazam, P. Edwards, S. Maybaum, R.A. Bello, and D.A. D'Alessandro Increased incidence of gastrointestinal bleeding following implantation of the HeartMate II LVAD J Card Surg 25 2010 352 356
-
(2010)
J Card Surg
, vol.25
, pp. 352-356
-
-
Stern, D.R.1
Kazam, J.2
Edwards, P.3
Maybaum, S.4
Bello, R.A.5
D'Alessandro, D.A.6
-
18
-
-
12944288246
-
Numerical studies of blood shear and washing in a continuous flow ventricular assist device
-
J.B. Anderson, H.G. Wood, P.E. Allaire, J.C. McDaniel, D.B. Olsen, and G. Bearnson Numerical studies of blood shear and washing in a continuous flow ventricular assist device ASAIO J 46 2000 486 494
-
(2000)
ASAIO J
, vol.46
, pp. 486-494
-
-
Anderson, J.B.1
Wood, H.G.2
Allaire, P.E.3
McDaniel, J.C.4
Olsen, D.B.5
Bearnson, G.6
-
19
-
-
11144347532
-
Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics
-
X. Song, A.L. Throckmorton, H.G. Wood, J.F. Antaki, and D.B. Olsen Quantitative evaluation of blood damage in a centrifugal VAD by computational fluid dynamics J Fluids Eng 126 2004 410 418
-
(2004)
J Fluids Eng
, vol.126
, pp. 410-418
-
-
Song, X.1
Throckmorton, A.L.2
Wood, H.G.3
Antaki, J.F.4
Olsen, D.B.5
-
20
-
-
2342556423
-
Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device
-
X. Song, A. Untaroiu, H.G. Wood, P.E. Allaire, A.L. Throckmorton, and S.W. Day Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device ASAIO J 50 2004 215 224
-
(2004)
ASAIO J
, vol.50
, pp. 215-224
-
-
Song, X.1
Untaroiu, A.2
Wood, H.G.3
Allaire, P.E.4
Throckmorton, A.L.5
Day, S.W.6
-
21
-
-
50449098285
-
Mechanisms of thrombus formation
-
B. Furie, and B.C. Furie Mechanisms of thrombus formation N Engl J Med 359 2008 938 949
-
(2008)
N Engl J Med
, vol.359
, pp. 938-949
-
-
Furie, B.1
Furie, B.C.2
-
22
-
-
0030664285
-
Analysis of the involvement of the von Willebrand factor glycoprotein Ib interaction in platelet adhesion to a collagen-coated surface under flow conditions
-
M. Moroi, S.M. Jung, S. Nomura, S. Sekiguchi, A. Ordinas, and M. Diaz-Ricart Analysis of the involvement of the von Willebrand factor glycoprotein Ib interaction in platelet adhesion to a collagen-coated surface under flow conditions Blood 90 1997 4413 4424
-
(1997)
Blood
, vol.90
, pp. 4413-4424
-
-
Moroi, M.1
Jung, S.M.2
Nomura, S.3
Sekiguchi, S.4
Ordinas, A.5
Diaz-Ricart, M.6
-
23
-
-
0038363984
-
Glycoprotein Ib-IX-V
-
R.K. Andrews, E.E. Gardiner, Y. Shen, J.C. Whisstock, and M.C. Berndt Glycoprotein Ib-IX-V Int J Biochem Cell Biol 35 2003 1170 1174
-
(2003)
Int J Biochem Cell Biol
, vol.35
, pp. 1170-1174
-
-
Andrews, R.K.1
Gardiner, E.E.2
Shen, Y.3
Whisstock, J.C.4
Berndt, M.C.5
-
24
-
-
0037417375
-
Intercellular calcium communication regulates platelet aggregation and thrombus growth
-
W.S. Nesbitt, S. Giuliano, S. Kulkarni, S.M. Dopheide, I.S. Harper, and S.P. Jackson Intercellular calcium communication regulates platelet aggregation and thrombus growth J Cell Biol 160 2003 1151 1161
-
(2003)
J Cell Biol
, vol.160
, pp. 1151-1161
-
-
Nesbitt, W.S.1
Giuliano, S.2
Kulkarni, S.3
Dopheide, S.M.4
Harper, I.S.5
Jackson, S.P.6
-
25
-
-
0037169514
-
Distinct glycoprotein Ib/V/IX and integrin alpha IIb beta 3-dependent calcium signals cooperatively regulate platelet adhesion under flow
-
W.S. Nesbitt, S. Kulkarni, S. Giuliano, I. Goncalves, S.M. Dopheide, and C.L. Yap Distinct glycoprotein Ib/V/IX and integrin alpha IIb beta 3-dependent calcium signals cooperatively regulate platelet adhesion under flow J Biol Chem 277 2002 2965 2972
-
(2002)
J Biol Chem
, vol.277
, pp. 2965-2972
-
-
Nesbitt, W.S.1
Kulkarni, S.2
Giuliano, S.3
Goncalves, I.4
Dopheide, S.M.5
Yap, C.L.6
-
27
-
-
84860803422
-
Pathologic shear triggers shedding of vascular receptors: A novel mechanism for down-regulation of platelet glycoprotein VI in stenosed coronary vessels
-
M. Al-Tamimi, C.W. Tan, J. Qiao, G.J. Pennings, A. Javadzadegan, and A.S.C. Yong Pathologic shear triggers shedding of vascular receptors: a novel mechanism for down-regulation of platelet glycoprotein VI in stenosed coronary vessels Blood 119 2012 4311 4320
-
(2012)
Blood
, vol.119
, pp. 4311-4320
-
-
Al-Tamimi, M.1
Tan, C.W.2
Qiao, J.3
Pennings, G.J.4
Javadzadegan, A.5
Yong, A.S.C.6
-
28
-
-
72249088796
-
Shear-induced interaction of platelets with von Willebrand factor results in glycoprotein Ibα shedding
-
H. Cheng, R. Yan, S. Li, Y. Yuan, J. Liu, and C. Ruan Shear-induced interaction of platelets with von Willebrand factor results in glycoprotein Ibα shedding Am J Physiol Heart Circ Physiol 297 2009 H2128 H2135
-
(2009)
Am J Physiol Heart Circ Physiol
, vol.297
, pp. H2128-H2135
-
-
Cheng, H.1
Yan, R.2
Li, S.3
Yuan, Y.4
Liu, J.5
Ruan, C.6
-
29
-
-
84863514397
-
Evaluation of Eulerian and Lagrangian models for hemolysis estimation
-
M.E. Taskin, K.H. Fraser, T. Zhang, C. Wu, B.P. Griffith, and Z.J. Wu Evaluation of Eulerian and Lagrangian models for hemolysis estimation ASAIO J 58 2012 363 372
-
(2012)
ASAIO J
, vol.58
, pp. 363-372
-
-
Taskin, M.E.1
Fraser, K.H.2
Zhang, T.3
Wu, C.4
Griffith, B.P.5
Wu, Z.J.6
-
30
-
-
84892185217
-
Platelet glycoprotein Ibα ectodomain shedding and non-surgical bleeding in heart failure patients supported by continuous-flow left ventricular assist devices
-
J. Hu, N.K. Mondal, E.N. Sorensen, L. Cai, H.-B. Fang, and B.P. Griffith Platelet glycoprotein Ibα ectodomain shedding and non-surgical bleeding in heart failure patients supported by continuous-flow left ventricular assist devices J Heart Lung Transplant 33 2014 71 79
-
(2014)
J Heart Lung Transplant
, vol.33
, pp. 71-79
-
-
Hu, J.1
Mondal, N.K.2
Sorensen, E.N.3
Cai, L.4
Fang, H.-B.5
Griffith, B.P.6
-
31
-
-
34948848572
-
Platelet glycoprotein VI-related clinical defects
-
J.F. Arthur, S. Dunkley, and R.K. Andrews Platelet glycoprotein VI-related clinical defects Br J Haematol 139 2007 363 372
-
(2007)
Br J Haematol
, vol.139
, pp. 363-372
-
-
Arthur, J.F.1
Dunkley, S.2
Andrews, R.K.3
-
32
-
-
0035910757
-
Long-term antithrombotic protection by in vivo depletion of platelet glycoprotein VI in mice
-
B. Nieswandt, V. Schulte, W. Bergmeier, Re Mokhtari-Nejad, K. Rackebrandt, and J.-P. Cazenave Long-term antithrombotic protection by in vivo depletion of platelet glycoprotein VI in mice J Exp Med 193 2001 459 470
-
(2001)
J Exp Med
, vol.193
, pp. 459-470
-
-
Nieswandt, B.1
Schulte, V.2
Bergmeier, W.3
Mokhtari-Nejad, R.4
Rackebrandt, K.5
Cazenave, J.-P.6
-
33
-
-
82955161196
-
Study of Flow-Induced Hemolysis Using Novel Couette-Type Blood-Shearing Devices
-
T. Zhang, M.E. Taskin, H.B. Fang, A. Pampori, R. Jarvik, and B.P. Griffith Study of Flow-Induced Hemolysis Using Novel Couette-Type Blood-Shearing Devices Artif Organs 35 2011 1180 1186
-
(2011)
Artif Organs
, vol.35
, pp. 1180-1186
-
-
Zhang, T.1
Taskin, M.E.2
Fang, H.B.3
Pampori, A.4
Jarvik, R.5
Griffith, B.P.6
-
35
-
-
84925008039
-
Quantification of Shear-Induced Platelet Activation: High Shear Stresses for Short Exposure Time
-
[in press]
-
J. Ding, Z.S. Chen, S.Q. Niu, J.F. Zhang, N.K. Mondal, and B.P. Griffith Quantification of Shear-Induced Platelet Activation: High Shear Stresses for Short Exposure Time Artif Organs 2015 [in press]
-
(2015)
Artif Organs
-
-
Ding, J.1
Chen, Z.S.2
Niu, S.Q.3
Zhang, J.F.4
Mondal, N.K.5
Griffith, B.P.6
-
36
-
-
40649123746
-
Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease
-
U. Geisen, C. Heilmann, F. Beyersdorf, C. Benk, M. Berchtold-Herz, and C. Schlensak Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease Eur J Cardiothorac Surg 33 2008 679 684
-
(2008)
Eur J Cardiothorac Surg
, vol.33
, pp. 679-684
-
-
Geisen, U.1
Heilmann, C.2
Beyersdorf, F.3
Benk, C.4
Berchtold-Herz, M.5
Schlensak, C.6
-
37
-
-
78650155308
-
Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device
-
A.L. Meyer, D. Malehsa, C. Bara, U. Budde, M.S. Slaughter, and A. Haverich Acquired von Willebrand syndrome in patients with an axial flow left ventricular assist device Circ Heart Fail 3 2010 675 681
-
(2010)
Circ Heart Fail
, vol.3
, pp. 675-681
-
-
Meyer, A.L.1
Malehsa, D.2
Bara, C.3
Budde, U.4
Slaughter, M.S.5
Haverich, A.6
|