-
1
-
-
1542614574
-
Destination therapy with ventricular assist devices
-
J. Raman, and V. Jeevanadam Destination therapy with ventricular assist devices Cardiology 101 1-3 2004 104 110
-
(2004)
Cardiology
, vol.101
, Issue.13
, pp. 104-110
-
-
Raman, J.1
Jeevanadam, V.2
-
2
-
-
79957474297
-
Current state of ventricular assist devices
-
M. Caccamo, P. Eckman, and R. John Current state of ventricular assist devices Curr Heart Fail Rep 8 2 Jun 2011 91 98
-
(2011)
Curr Heart Fail Rep
, vol.8
, Issue.2
, pp. 91-98
-
-
Caccamo, M.1
Eckman, P.2
John, R.3
-
3
-
-
0035892018
-
Long-term use of a left ventricular assist device for end-stage heart failure
-
E.A. Rose, A.C. Gelijns, and A.J. Moskowitz Long-term use of a left ventricular assist device for end-stage heart failure N Engl J Med 345 20 Nov 15 2001 1435 1443
-
(2001)
N Engl J Med
, vol.345
, Issue.20
, pp. 1435-1443
-
-
Rose, E.A.1
Gelijns, A.C.2
Moskowitz, A.J.3
-
4
-
-
2342437924
-
Bridging to transplant with the HeartMate left ventricular assist device: The Columbia Presbyterian 12-year experience
-
J.A. Morgan, R. John, and V. Rao Bridging to transplant with the HeartMate left ventricular assist device: the Columbia Presbyterian 12-year experience J Thorac Cardiovasc Surg 127 5 May 2004 1309 1316
-
(2004)
J Thorac Cardiovasc Surg
, vol.127
, Issue.5
, pp. 1309-1316
-
-
Morgan, J.A.1
John, R.2
Rao, V.3
-
5
-
-
0035100167
-
Clinical experience with the MicroMed DeBakey ventricular assist device
-
G.P. Noon, D.L. Morley, and S. Irwin Clinical experience with the MicroMed DeBakey ventricular assist device Ann Thorac Surg 71 Suppl. 3 Mar 2001 S133 S138 discussion S144-S136
-
(2001)
Ann Thorac Surg
, vol.71
, Issue.SUPPL. 3
-
-
Noon, G.P.1
Morley, D.L.2
Irwin, S.3
-
6
-
-
2442455904
-
First experiences with a novel magnetically suspended axial flow left ventricular assist device
-
R. Hetzer, Y. Weng, and E.V. Potapov First experiences with a novel magnetically suspended axial flow left ventricular assist device Eur J Cardiothorac Surg 25 6 Jun 2004 964 970
-
(2004)
Eur J Cardiothorac Surg
, vol.25
, Issue.6
, pp. 964-970
-
-
Hetzer, R.1
Weng, Y.2
Potapov, E.V.3
-
7
-
-
0034823898
-
The Heartmate III: Design and in vivo studies of a maglev centrifugal left ventricular assist device
-
H.M. Loree, K. Bourque, and D.B. Gernes The Heartmate III: design and in vivo studies of a maglev centrifugal left ventricular assist device Artif Organs 25 5 May 2001 386 391
-
(2001)
Artif Organs
, vol.25
, Issue.5
, pp. 386-391
-
-
Loree, H.M.1
Bourque, K.2
Gernes, D.B.3
-
8
-
-
34547822405
-
Integration of signal pathways for stretch-dependent growth and differentiation in vascular smooth muscle
-
S. Albinsson, and P. Hellstrand Integration of signal pathways for stretch-dependent growth and differentiation in vascular smooth muscle Am J Physiol Cell Physiol 293 2 Aug 2007 C772 C782
-
(2007)
Am J Physiol Cell Physiol
, vol.293
, Issue.2
-
-
Albinsson, S.1
Hellstrand, P.2
-
9
-
-
66749092335
-
Cyclic stretch, reactive oxygen species, and vascular remodeling
-
K.G. Birukov Cyclic stretch, reactive oxygen species, and vascular remodeling Antioxid Redox Signal 11 7 Jul 2009 1651 1667
-
(2009)
Antioxid Redox Signal
, vol.11
, Issue.7
, pp. 1651-1667
-
-
Birukov, K.G.1
-
10
-
-
0028916537
-
Stretch affects phenotype and proliferation of vascular smooth muscle cells
-
K.G. Birukov, V.P. Shirinsky, and O.V. Stepanova Stretch affects phenotype and proliferation of vascular smooth muscle cells Mol Cell Biochem 144 2 Mar 23 1995 131 139
-
(1995)
Mol Cell Biochem
, vol.144
, Issue.2
, pp. 131-139
-
-
Birukov, K.G.1
Shirinsky, V.P.2
Stepanova, O.V.3
-
11
-
-
0011034337
-
The physiolgic importance of pulsatile blood flow
-
H. Wilkens, W. Regelson, and F.S. Hoffmeister The physiolgic importance of pulsatile blood flow N Engl J Med 267 Aug 30 1962 443 446
-
(1962)
N Engl J Med
, vol.267
, pp. 443-446
-
-
Wilkens, H.1
Regelson, W.2
Hoffmeister, F.S.3
-
12
-
-
0032818022
-
Diminished vasoconstrictive function caused by long-term nonpulsatile left heart bypass
-
T. Nishimura, E. Tatsumi, and T. Nishinaka Diminished vasoconstrictive function caused by long-term nonpulsatile left heart bypass Artif Organs 23 8 Aug 1999 722 726
-
(1999)
Artif Organs
, vol.23
, Issue.8
, pp. 722-726
-
-
Nishimura, T.1
Tatsumi, E.2
Nishinaka, T.3
-
13
-
-
12944272021
-
Effects of long-term nonpulsatile left heart bypass on the mechanical properties of the aortic wall
-
T. Nishimura, E. Tatsumi, and Y. Taenaka Effects of long-term nonpulsatile left heart bypass on the mechanical properties of the aortic wall ASAIO J 45 5 Sep-Oct 1999 455 459
-
(1999)
ASAIO J
, vol.45
, Issue.5
, pp. 455-459
-
-
Nishimura, T.1
Tatsumi, E.2
Taenaka, Y.3
-
14
-
-
0033839958
-
Effects of reduced pulse pressure to the cerebral metabolism during prolonged nonpulsatile left heart bypass
-
T. Nishinaka, E. Tatsumi, and T. Nishimura Effects of reduced pulse pressure to the cerebral metabolism during prolonged nonpulsatile left heart bypass Artif Organs 24 8 Aug 2000 676 679
-
(2000)
Artif Organs
, vol.24
, Issue.8
, pp. 676-679
-
-
Nishinaka, T.1
Tatsumi, E.2
Nishimura, T.3
-
15
-
-
33845787566
-
Endocrine function is not impaired in patients with a continuous MicroMed-DeBakey axial flow pump
-
G.M. Wieselthaler, M. Riedl, and H. Schima Endocrine function is not impaired in patients with a continuous MicroMed-DeBakey axial flow pump J Thorac Cardiovasc Surg 133 1 Jan 2007 2 6
-
(2007)
J Thorac Cardiovasc Surg
, vol.133
, Issue.1
, pp. 2-6
-
-
Wieselthaler, G.M.1
Riedl, M.2
Schima, H.3
-
16
-
-
0028060534
-
Influences of nonpulsatile pulmonary flow on pulmonary function. Evaluation in a chronic animal model
-
M. Sakaki, Y. Taenaka, and E. Tatsumi Influences of nonpulsatile pulmonary flow on pulmonary function. Evaluation in a chronic animal model J Thorac Cardiovasc Surg 108 3 Sep 1994 495 502
-
(1994)
J Thorac Cardiovasc Surg
, vol.108
, Issue.3
, pp. 495-502
-
-
Sakaki, M.1
Taenaka, Y.2
Tatsumi, E.3
-
17
-
-
0036798185
-
End-organ function during chronic nonpulsatile circulation
-
S. Saito, S. Westaby, and D. Piggot End-organ function during chronic nonpulsatile circulation Ann Thorac Surg 74 4 Oct 2002 1080 1085
-
(2002)
Ann Thorac Surg
, vol.74
, Issue.4
, pp. 1080-1085
-
-
Saito, S.1
Westaby, S.2
Piggot, D.3
-
18
-
-
8544243482
-
Renal circulation and cellular metabolism during left ventricular assisted circulation: Comparison study of pulsatile and nonpulsatile assists
-
A. Sezai, M. Shiono, and Y. Orime Renal circulation and cellular metabolism during left ventricular assisted circulation: comparison study of pulsatile and nonpulsatile assists Artif Organs 21 7 Jul 1997 830 835
-
(1997)
Artif Organs
, vol.21
, Issue.7
, pp. 830-835
-
-
Sezai, A.1
Shiono, M.2
Orime, Y.3
-
19
-
-
0141786640
-
Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months
-
G.V. Letsou, T.J. Myers, and I.D. Gregoric Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months Ann Thorac Surg 76 4 Oct 2003 1167 1170
-
(2003)
Ann Thorac Surg
, vol.76
, Issue.4
, pp. 1167-1170
-
-
Letsou, G.V.1
Myers, T.J.2
Gregoric, I.D.3
-
20
-
-
34547583929
-
End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices
-
B. Radovancevic, B. Vrtovec, and E. de Kort End-organ function in patients on long-term circulatory support with continuous- or pulsatile-flow assist devices J Heart Lung Transplant 26 8 Aug 2007 815 818
-
(2007)
J Heart Lung Transplant
, vol.26
, Issue.8
, pp. 815-818
-
-
Radovancevic, B.1
Vrtovec, B.2
De Kort, E.3
-
21
-
-
63149192300
-
Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients
-
F. Kamdar, A. Boyle, and K. Liao Effects of centrifugal, axial, and pulsatile left ventricular assist device support on end-organ function in heart failure patients J Heart Lung Transplant 28 4 Apr 2009 352 359
-
(2009)
J Heart Lung Transplant
, vol.28
, Issue.4
, pp. 352-359
-
-
Kamdar, F.1
Boyle, A.2
Liao, K.3
-
22
-
-
58249093243
-
Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices
-
S. Crow, R. John, and A. Boyle Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices J Thorac Cardiovasc Surg 137 1 Jan 2009 208 215
-
(2009)
J Thorac Cardiovasc Surg
, vol.137
, Issue.1
, pp. 208-215
-
-
Crow, S.1
John, R.2
Boyle, A.3
-
23
-
-
79960015603
-
Arteriovenous malformation and gastrointestinal bleeding in patients with the HeartMate II left ventricular assist device
-
Z.T. Demirozu, R. Radovancevic, and L.F. Hochman Arteriovenous malformation and gastrointestinal bleeding in patients with the HeartMate II left ventricular assist device J Heart Lung Transplant 30 8 Aug 2011 849 853
-
(2011)
J Heart Lung Transplant
, vol.30
, Issue.8
, pp. 849-853
-
-
Demirozu, Z.T.1
Radovancevic, R.2
Hochman, L.F.3
-
24
-
-
0026725790
-
Aortic stenosis and bleeding gastrointestinal angiodysplasia: Is acquired von Willebrand's disease the link?
-
T.E. Warkentin, J.C. Moore, and D.G. Morgan Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand's disease the link? Lancet 340 8810 Jul 4 1992 35 37
-
(1992)
Lancet
, vol.340
, Issue.8810
, pp. 35-37
-
-
Warkentin, T.E.1
Moore, J.C.2
Morgan, D.G.3
-
25
-
-
0017388806
-
On the nature and etiology of vascular ectasias of the colon. Degenerative lesions of aging
-
S.J. Boley, R. Sammartano, and A. Adams On the nature and etiology of vascular ectasias of the colon. Degenerative lesions of aging Gastroenterology 72 4 Pt 1 Apr 1977 650 660
-
(1977)
Gastroenterology
, vol.72
, Issue.4 PART 1
, pp. 650-660
-
-
Boley, S.J.1
Sammartano, R.2
Adams, A.3
-
26
-
-
18844396181
-
Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: A comparative analysis with pulsatile-type devices
-
V. Thohan, S.J. Stetson, and S.F. Nagueh Cellular and hemodynamics responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices J Heart Lung Transplant 24 5 May 2005 566 575
-
(2005)
J Heart Lung Transplant
, vol.24
, Issue.5
, pp. 566-575
-
-
Thohan, V.1
Stetson, S.J.2
Nagueh, S.F.3
-
27
-
-
77956394931
-
Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle
-
C.R. Bartoli, G.A. Giridharan, and K.N. Litwak Hemodynamic responses to continuous versus pulsatile mechanical unloading of the failing left ventricle ASAIO J 56 5 Sep-Oct 2010 410 416
-
(2010)
ASAIO J
, vol.56
, Issue.5
, pp. 410-416
-
-
Bartoli, C.R.1
Giridharan, G.A.2
Litwak, K.N.3
-
28
-
-
83555170951
-
Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling
-
T.S. Kato, A. Chokshi, and P. Singh Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling Circ Heart Fail 4 5 Sep 1 2011 546 553
-
(2011)
Circ Heart Fail
, vol.4
, Issue.5
, pp. 546-553
-
-
Kato, T.S.1
Chokshi, A.2
Singh, P.3
-
29
-
-
27544432577
-
Clinical outcomes in patients with chronic congestive heart failure who undergo left ventricular assist device implantation
-
N.C. Dang, V.K. Topkara, and B.T. Kim Clinical outcomes in patients with chronic congestive heart failure who undergo left ventricular assist device implantation J Thorac Cardiovasc Surg 130 5 Nov 2005 1302 1309
-
(2005)
J Thorac Cardiovasc Surg
, vol.130
, Issue.5
, pp. 1302-1309
-
-
Dang, N.C.1
Topkara, V.K.2
Kim, B.T.3
-
30
-
-
0031542957
-
Implantable left ventricular assist devices provide an excellent outpatient bridge to transplantation and recovery
-
J.J. DeRose Jr., J.P. Umana, and M. Argenziano Implantable left ventricular assist devices provide an excellent outpatient bridge to transplantation and recovery J Am Coll Cardiol 30 7 Dec 1997 1773 1777
-
(1997)
J Am Coll Cardiol
, vol.30
, Issue.7
, pp. 1773-1777
-
-
DeRose Jr., J.J.1
Umana, J.P.2
Argenziano, M.3
-
31
-
-
0031461068
-
Implantable left ventricular assist devices: An evolving long-term cardiac replacement therapy
-
J.J. DeRose, M. Argenziano, and B.C. Sun Implantable left ventricular assist devices: an evolving long-term cardiac replacement therapy Ann Surg 226 4 Oct 1997 461 468 discussion 468-470
-
(1997)
Ann Surg
, vol.226
, Issue.4
, pp. 461-468
-
-
Derose, J.J.1
Argenziano, M.2
Sun, B.C.3
-
32
-
-
0042917714
-
Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation
-
D.J. Goldstein Worldwide experience with the MicroMed DeBakey ventricular assist device as a bridge to transplantation Circulation 108 Suppl. 1 Sep 9 2003 II272 II277
-
(2003)
Circulation
, vol.108
, Issue.SUPPL. 1
-
-
Goldstein, D.J.1
-
33
-
-
34548311569
-
Use of a continuous-flow device in patients awaiting heart transplantation
-
L.W. Miller, F.D. Pagani, and S.D. Russell Use of a continuous-flow device in patients awaiting heart transplantation N Engl J Med 357 9 Aug 30 2007 885 896
-
(2007)
N Engl J Med
, vol.357
, Issue.9
, pp. 885-896
-
-
Miller, L.W.1
Pagani, F.D.2
Russell, S.D.3
-
34
-
-
33750077594
-
Does continuous flow left ventricular assist device technology have a positive impact on outcome pretransplant and posttransplant?
-
S. Klotz, J. Stypmann, and H. Welp Does continuous flow left ventricular assist device technology have a positive impact on outcome pretransplant and posttransplant? Ann Thorac Surg 82 5 Nov 2006 1774 1778
-
(2006)
Ann Thorac Surg
, vol.82
, Issue.5
, pp. 1774-1778
-
-
Klotz, S.1
Stypmann, J.2
Welp, H.3
-
35
-
-
46749139121
-
Clinical outcome and bridge to transplant rate of left ventricular assist device recipient patients: Comparison between continuous-flow and pulsatile-flow devices
-
A. Garatti, G. Bruschi, and T. Colombo Clinical outcome and bridge to transplant rate of left ventricular assist device recipient patients: comparison between continuous-flow and pulsatile-flow devices Eur J Cardiothorac Surg 34 2 Aug 2008 275 280 discussion 280
-
(2008)
Eur J Cardiothorac Surg
, vol.34
, Issue.2
, pp. 275-280
-
-
Garatti, A.1
Bruschi, G.2
Colombo, T.3
-
36
-
-
79959986433
-
Changing outcomes in patients bridged to heart transplantation with continuous- versus pulsatile-flow ventricular assist devices: An analysis of the registry of the International Society for Heart and Lung Transplantation
-
J.N. Nativi, S.G. Drakos, and A.Y. Kucheryavaya Changing outcomes in patients bridged to heart transplantation with continuous- versus pulsatile-flow ventricular assist devices: an analysis of the registry of the International Society for Heart and Lung Transplantation J Heart Lung Transplant 30 8 Aug 2011 854 861
-
(2011)
J Heart Lung Transplant
, vol.30
, Issue.8
, pp. 854-861
-
-
Nativi, J.N.1
Drakos, S.G.2
Kucheryavaya, A.Y.3
-
37
-
-
73349129701
-
Advanced heart failure treated with continuous-flow left ventricular assist device
-
M.S. Slaughter, J.G. Rogers, and C.A. Milano Advanced heart failure treated with continuous-flow left ventricular assist device N Engl J Med 361 23 Dec 3 2009 2241 2251
-
(2009)
N Engl J Med
, vol.361
, Issue.23
, pp. 2241-2251
-
-
Slaughter, M.S.1
Rogers, J.G.2
Milano, C.A.3
-
38
-
-
77957121107
-
Infectious complications in patients with left ventricular assist device: Etiology and outcomes in the continuous-flow era
-
V.K. Topkara, S. Kondareddy, and F. Malik Infectious complications in patients with left ventricular assist device: etiology and outcomes in the continuous-flow era Ann Thorac Surg 90 4 Oct 2010 1270 1277
-
(2010)
Ann Thorac Surg
, vol.90
, Issue.4
, pp. 1270-1277
-
-
Topkara, V.K.1
Kondareddy, S.2
Malik, F.3
-
39
-
-
33847245851
-
Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients
-
E.D. Feller, E.N. Sorensen, and M. Haddad Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients Ann Thorac Surg 83 3 Mar 2007 1082 1088
-
(2007)
Ann Thorac Surg
, vol.83
, Issue.3
, pp. 1082-1088
-
-
Feller, E.D.1
Sorensen, E.N.2
Haddad, M.3
-
40
-
-
0028469276
-
Ventricular interactions during mechanical circulatory support
-
D.J. Farrar Ventricular interactions during mechanical circulatory support Semin Thorac Cardiovasc Surg 6 3 Jul 1994 163 168
-
(1994)
Semin Thorac Cardiovasc Surg
, vol.6
, Issue.3
, pp. 163-168
-
-
Farrar, D.J.1
-
41
-
-
0021964977
-
Right heart interaction with the mechanically assisted left heart
-
D.J. Farrar, P.G. Compton, and J.J. Hershon Right heart interaction with the mechanically assisted left heart World J Surg 9 1 Feb 1985 89 102
-
(1985)
World J Surg
, vol.9
, Issue.1
, pp. 89-102
-
-
Farrar, D.J.1
Compton, P.G.2
Hershon, J.J.3
-
42
-
-
62849084374
-
Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device
-
J.R. Fitzpatrick 3rd, J.R. Frederick, and W. Hiesinger Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device J Thorac Cardiovasc Surg 137 4 Apr 2009 971 977
-
(2009)
J Thorac Cardiovasc Surg
, vol.137
, Issue.4
, pp. 971-977
-
-
Fitzpatrick III, J.R.1
Frederick, J.R.2
Hiesinger, W.3
-
43
-
-
44049094013
-
The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates
-
J.C. Matthews, T.M. Koelling, and F.D. Pagani The right ventricular failure risk score a pre-operative tool for assessing the risk of right ventricular failure in left ventricular assist device candidates J Am Coll Cardiol 51 22 Jun 3 2008 2163 2172
-
(2008)
J Am Coll Cardiol
, vol.51
, Issue.22
, pp. 2163-2172
-
-
Matthews, J.C.1
Koelling, T.M.2
Pagani, F.D.3
-
44
-
-
77949571229
-
Risk factors predictive of right ventricular failure after left ventricular assist device implantation
-
S.G. Drakos, L. Janicki, and B.D. Horne Risk factors predictive of right ventricular failure after left ventricular assist device implantation Am J Cardiol 105 7 Apr 1 2010 1030 1035
-
(2010)
Am J Cardiol
, vol.105
, Issue.7
, pp. 1030-1035
-
-
Drakos, S.G.1
Janicki, L.2
Horne, B.D.3
-
45
-
-
77949490707
-
Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomes
-
R.L. Kormos, J.J. Teuteberg, and F.D. Pagani Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes J Thorac Cardiovasc Surg 139 5 May 2010 1316 1324
-
(2010)
J Thorac Cardiovasc Surg
, vol.139
, Issue.5
, pp. 1316-1324
-
-
Kormos, R.L.1
Teuteberg, J.J.2
Pagani, F.D.3
-
46
-
-
49549110298
-
Right heart dysfunction after left ventricular assist device implantation: A comparison of the pulsatile HeartMate i and axial-flow HeartMate II devices
-
N.D. Patel, E.S. Weiss, and J. Schaffer Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices Ann Thorac Surg 86 3 Sep 2008 832 840 discussion 832-840
-
(2008)
Ann Thorac Surg
, vol.86
, Issue.3
, pp. 832-840
-
-
Patel, N.D.1
Weiss, E.S.2
Schaffer, J.3
|