메뉴 건너뛰기




Volumn 35, Issue 12, 2011, Pages 1180-1186

Study of flow-induced hemolysis using novel couette-type blood-shearing devices

Author keywords

Blood shearing device; Exposure time; Flow induced hemolysis; Shear stress

Indexed keywords

BLOOD; COMPUTATIONAL FLUID DYNAMICS; DAMAGE DETECTION; SEALS; SHEAR FLOW; SHEARING;

EID: 82955161196     PISSN: 0160564X     EISSN: 15251594     Source Type: Journal    
DOI: 10.1111/j.1525-1594.2011.01243.x     Document Type: Article
Times cited : (157)

References (12)
  • 1
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart valve prostheses—in vitro comparison of 25 aortic valves
    • Giersiepen M, Wurzinger LJ, Opitz R, Reul H. Estimation of shear stress-related blood damage in heart valve prostheses—in vitro comparison of 25 aortic valves. Int J Artif Organs 1990;13:300–6.
    • (1990) Int J Artif Organs , vol.13 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Opitz, R.3    Reul, H.4
  • 2
    • 0006708051 scopus 로고    scopus 로고
    • Relative blood damage index of the jellyfish valve and the Bjork-Shiley tilting-disk valve
    • Morsi Y, Kogure M, Umezu M. Relative blood damage index of the jellyfish valve and the Bjork-Shiley tilting-disk valve. J Artif Organs 1999;2:163–9.
    • (1999) J Artif Organs , vol.2 , pp. 163-169
    • Morsi, Y.1    Kogure, M.2    Umezu, M.3
  • 5
    • 33646271378 scopus 로고    scopus 로고
    • Hemolysis resulting from surface roughness under shear flow conditions using a rotational shear stressor
    • Maruyama O, Nishida M, Yamane T, Oshima I, Adachi Y, Masuzawa T. Hemolysis resulting from surface roughness under shear flow conditions using a rotational shear stressor. Artif Organs 2006;30:365–70.
    • (2006) Artif Organs , vol.30 , pp. 365-370
    • Maruyama, O.1    Nishida, M.2    Yamane, T.3    Oshima, I.4    Adachi, Y.5    Masuzawa, T.6
  • 6
    • 0001700505 scopus 로고
    • Stability of a viscous liquid contained between two rotating cylinders
    • Taylor GI. Stability of a viscous liquid contained between two rotating cylinders. Phil Trans R Soc Lond A 1923;223:289–343.
    • (1923) Phil Trans R Soc Lond A , vol.223 , pp. 289-343
    • Taylor, G.I.1
  • 7
    • 0029085081 scopus 로고
    • Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump
    • Bludszuweit C. Three-dimensional numerical prediction of stress loading of blood particles in a centrifugal pump. Artif Organs 1995;19:590–6.
    • (1995) Artif Organs , vol.19 , pp. 590-596
    • Bludszuweit, C.1
  • 8
    • 33846273513 scopus 로고    scopus 로고
    • The effect of angle on wall shear stresses in a LIMA to LAD anastomosis: Numerical modelling of pulsatile flow
    • Freshwater IJ, Morsi YS, Lai T. The effect of angle on wall shear stresses in a LIMA to LAD anastomosis: numerical modelling of pulsatile flow. Proc Inst Mech Eng [H] 2006;220:743–57.
    • (2006) Proc Inst Mech Eng [H] , vol.220 , pp. 743-757
    • Freshwater, I.J.1    Morsi, Y.S.2    Lai, T.3
  • 9
    • 0031474786 scopus 로고    scopus 로고
    • Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices
    • Malinauskas RA. Plasma hemoglobin measurement techniques for the in vitro evaluation of blood damage caused by medical devices. Artif Organs 1997;21:1255–67.
    • (1997) Artif Organs , vol.21 , pp. 1255-1267
    • Malinauskas, R.A.1
  • 10
    • 0028466998 scopus 로고
    • Effect of perfluorochemical emulsion on blood trauma and hemorheology
    • Kameneva MV, Antaki JF, Konishi H, et al. Effect of perfluorochemical emulsion on blood trauma and hemorheology. ASAIO J 1994;40:M576–9.
    • (1994) ASAIO J , vol.40 , pp. M576-M579
    • Kameneva, M.V.1    Antaki, J.F.2    Konishi, H.3
  • 11
    • 0038726249 scopus 로고    scopus 로고
    • Experimental design and sample size determination for testing synergism in drug combination studies based on uniform measures
    • Tan M, Fang HB, Tian GL, Houghton PJ. Experimental design and sample size determination for testing synergism in drug combination studies based on uniform measures. Stat Med 2003;22:2091–100.
    • (2003) Stat Med , vol.22 , pp. 2091-2100
    • Tan, M.1    Fang, H.B.2    Tian, G.L.3    Houghton, P.J.4
  • 12
    • 0242333304 scopus 로고    scopus 로고
    • Computational fluid dynamics prediction of blood damage in a centrifugal pump
    • Song X, Throckmorton AL, Wood HG, Antaki JF, Olsen DB. Computational fluid dynamics prediction of blood damage in a centrifugal pump. Artif Organs 2003;27:938–41.
    • (2003) Artif Organs , vol.27 , pp. 938-941
    • Song, X.1    Throckmorton, A.L.2    Wood, H.G.3    Antaki, J.F.4    Olsen, D.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.