메뉴 건너뛰기




Volumn 134, Issue 8, 2012, Pages

A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: Shear stress, exposure time and hemolysis index

Author keywords

artificial organs; computational fluid dynamics (CFD); hemodynamics; hemolysis; platelet activation; thrombosis; ventricular assist device (VAD); von Willebrand factor (vWf)

Indexed keywords

HEMOLYSIS; PLATELET ACTIVATION; THROMBOSIS; VENTRICULAR ASSIST DEVICE; VON WILLEBRAND FACTOR;

EID: 84864848430     PISSN: 01480731     EISSN: 15288951     Source Type: Journal    
DOI: 10.1115/1.4007092     Document Type: Article
Times cited : (299)

References (64)
  • 2
    • 77649126524 scopus 로고    scopus 로고
    • Heart disease and stroke statisitics 2010 update: A report from the american heart association
    • Lloyd-Jones, D., Adams, R. J., Brown, T. M., Carnethon, M., and Dai, S., 2010, "Heart Disease and Stroke Statisitics 2010 Update: A Report From the American Heart Association," Circulation, 121, pp. e46-e215.
    • (2010) Circulation , vol.121
    • Lloyd-Jones, D.1    Adams, R.J.2    Brown, T.M.3    Carnethon, M.4    Dai, S.5
  • 4
    • 78651236176 scopus 로고    scopus 로고
    • Health Resources and Services Administration, U. S. Department of Health and Human Services
    • Health Resources and Services Administration, U. S. Department of Health and Human Services, 2009, "Organ Procurement and Transplant Network."
    • (2009) Organ Procurement and Transplant Network
  • 5
    • 0030740053 scopus 로고    scopus 로고
    • The importance of pulsatile and nonpulsatile flow in the design of blood pumps
    • Allen, G. S., Murray, K. D., and Olsen, D. B., 1997, "The Importance of Pulsatile and Nonpulsatile Flow in the Design of Blood Pumps," Artif. Organs, 21, pp. 922-928. (Pubitemid 27325721)
    • (1997) Artificial Organs , vol.21 , Issue.8 , pp. 922-928
    • Allen, G.S.1    Murray, K.D.2    Olsen, D.B.3
  • 7
    • 0141813510 scopus 로고    scopus 로고
    • What price support? Ventricular assist device induced systemic response
    • DOI 10.1097/01.MAT.0000085672.42122.49
    • Thompson, L. O., Loebe, M., and Noon, G. P., 2003, "What Price Support? Ventricular Assist Device Induced Systemic Response," ASAIO J., 49, pp. 518-526. (Pubitemid 37129271)
    • (2003) ASAIO Journal , vol.49 , Issue.5 , pp. 518-526
    • Thompson, L.O.1    Loebe, M.2    Noon, G.P.3
  • 10
    • 0031854647 scopus 로고    scopus 로고
    • Red cell membrane damage
    • Kuypers, F. A., 1998, "Red Cell Membrane Damage," J. Heart Valve Dis., 7, pp. 387-395. (Pubitemid 28351303)
    • (1998) Journal of Heart Valve Disease , vol.7 , Issue.4 , pp. 387-395
    • Kuypers, F.A.1
  • 11
    • 0025082325 scopus 로고
    • Estimation of shear stress-related blood damage in heart valve prostheses - in vitro comparison of 25 aortic valves
    • Giersiepen, M., Wurzinger, L. J., Opitz, R., and Reul, H., 1990, "Estimation of Shear Stress-Related Blood Damage in Heart Valve Prosthesis-in vitro Comparison of 25 Aortic Valves," Int. J. Artif. Organs, 13, pp. 300-306. (Pubitemid 20310869)
    • (1990) International Journal of Artificial Organs , vol.13 , Issue.5 , pp. 300-306
    • Giersiepen, M.1    Wurzinger, L.J.2    Opitz, R.3    Reul, H.4
  • 12
    • 4444270516 scopus 로고    scopus 로고
    • The hemostatic system
    • Stassen, J. M., Arnout, J., and Deckmyn, H., 2004, "The Hemostatic System," Curr. Med. Chem., 11, pp. 2245-2260. Available at: http://www.ingentaconnect. com/content/ben/cmc/2004/00000011/00000017/art00002 (Pubitemid 39172347)
    • (2004) Current Medicinal Chemistry , vol.11 , Issue.17 , pp. 2245-2260
    • Stassen, J.M.1    Arnout, J.2    Deckmyn, H.3
  • 14
    • 0033161165 scopus 로고    scopus 로고
    • Computational simulation of platelet deposition and activation: I. Model Development and Properties
    • Sorensen, E. N., Burgreen, G. W., Wagner, W. R., and Antaki, J. F., 1999, "Computational Simulation of Platelet Deposition and Activation: I. Model Developement and Properties," Ann. Biomed. Eng., 27, pp. 436-448. (Pubitemid 129584998)
    • (1999) Annals of Biomedical Engineering , vol.27 , Issue.4-12 , pp. 436-448
    • Sorensen, E.N.1    Burgreen, G.W.2    Wagner, W.R.3    Antaki, J.F.4
  • 15
    • 0028500967 scopus 로고
    • 1993 Whitaker lecture: Biorheology in thrombosis research
    • DOI 10.1007/BF02367081
    • Hellums, J. D., 1994, "1993 Whitaker Lecture: Biorheology in Thrombosis Research," Ann. Biomed. Eng., 22, pp. 445-455. (Pubitemid 24327836)
    • (1994) Annals of Biomedical Engineering , vol.22 , Issue.5 , pp. 445-455
    • Hellums, J.D.1
  • 16
    • 0022214273 scopus 로고
    • Platelet and coagulation parameters following millisecond exposure to laminar shear stress
    • Wurzinger, L. J., Opitz, R., Blasberg, P., and Schmid-Schonbein, H., 1985, "Platelet and Coagulation Parameters Following Millisecond Exposure to Laminar Shear Stress," Thromb. Haemostasis, 54, pp. 381-386. (Pubitemid 16252453)
    • (1985) Thrombosis and Haemostasis , vol.54 , Issue.2 , pp. 381-386
    • Wurzinger, L.J.1    Opitz, R.2    Blasberg, P.3    Schmid-Schonbein, H.4
  • 17
    • 0032535509 scopus 로고    scopus 로고
    • Shear-induced platelet activation and platelet microparticle formation in native human blood
    • DOI 10.1016/S0049-3848(98)00158-3, PII S0049384898001583
    • Sakariassen, K. S., Holme, P. A., Orvin, U., Barstad, R. M., Solum, N. O., and Brosstad, F. R., 1998, "Shear-Induced Platelet Activation and Platelet Microparticle Formation in Native Human Blood," Thromb. Res., 92, pp. S33-S41. (Pubitemid 29012761)
    • (1998) Thrombosis Research , vol.92 , Issue.6 SUPPL. 2
    • Sakariassen, K.S.1    Holme, P.A.2    Orvim, U.3    Barstad, R.M.4    Solum, N.O.5    Brosstad, F.R.6
  • 18
    • 0142092583 scopus 로고    scopus 로고
    • Duration of exposure to high fluid shear stress is critical in shear-induced platelet activation-aggregation
    • Zhang, J.-N., Bergeron, A. L., Yu, Q., Sun, C., McBride, L., Bray, P. F., and Dong, J. F., 2003, "Duration of Exposure to High Fluid Shear Stress is Critical in Shear-Induced Platelet Activation-Aggregation," Thromb. Haemostasis, 90, pp. 672-678. (Pubitemid 37287635)
    • (2003) Thrombosis and Haemostasis , vol.90 , Issue.4 , pp. 672-678
    • Zhang, J.-N.1    Bergeron, A.L.2    Yu, Q.3    McBride, L.4    Bray, P.F.5    Dong, J.-F.6
  • 21
    • 0242426527 scopus 로고    scopus 로고
    • Short exposure time sensitivity of white cells to shear stress
    • DOI 10.1097/01.MAT.0000094194.93742.A7
    • Carter, J., Hristova, K., Harasaki, H., and Smith, W. A., 2003, "Short Exposure Time Sensitivity of White Cells to Shear Stress," ASAIO J., 49, pp. 687-691. (Pubitemid 37429668)
    • (2003) ASAIO Journal , vol.49 , Issue.6 , pp. 687-691
    • Carter, J.1    Hristova, K.2    Harasaki, H.3    Smith, W.A.4
  • 22
    • 0028266474 scopus 로고
    • Shear stress enhances the proteolysis of von Willebrand factor in normal plasma
    • Tsai, H.-M., Sussman, I. I., and Nagel, R. L., 1994, "Shear Stress Enhances the Proteolysis of von Willebrand Factor in Normal Plasma," Blood, 83, pp. 2171-2179. (Pubitemid 24112728)
    • (1994) Blood , vol.83 , Issue.8 , pp. 2171-2179
    • Tsai, H.-M.1    Sussman, I.I.2    Nagel, R.L.3
  • 24
    • 77957561535 scopus 로고    scopus 로고
    • Acquired von willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-Term support and at the time of transplantation"
    • Uriel, N., Pak, S.-W., Jorde, U. P., Jude, B., Susen, S., Vincentelli, A., Ennezat, P. V., Cappleman, S., Naka, Y., and Mancini, D., 2010, "Acquired von Willebrand Syndrome After Continuous-Flow Mechanical Device Support Contributes to a High Prevalence of Bleeding During Long-Term Support and at the Time of Transplantation," J. Am. Coll. Cardiol., 56, pp. 1207-1213.
    • (2010) J. Am. Coll. Cardiol. , vol.56 , pp. 1207-1213
    • Uriel, N.1    Pak, S.-W.2    Jorde, U.P.3    Jude, B.4    Susen, S.5    Vincentelli, A.6    Ennezat, P.V.7    Cappleman, S.8    Naka, Y.9    Mancini, D.10
  • 25
    • 78649756268 scopus 로고    scopus 로고
    • The effect of shear stress on protein conformation physical forces operating on biochemical systems: The case of von willebrand factor"
    • Di Stasio, E. and De Cristofaro, R., 2010, "The Effect of Shear Stress on Protein Conformation Physical Forces Operating on Biochemical Systems: The Case of von Willebrand Factor," Biophys. Chem., 153, pp. 1-8.
    • (2010) Biophys. Chem. , vol.153 , pp. 1-8
    • Di Stasio, E.1    De Cristofaro, R.2
  • 26
    • 79952313377 scopus 로고    scopus 로고
    • The use of computational fluid dynamics in the development of ventricular assist devices
    • Fraser, K. H., Taskin, M. E., Griffith, B. P., and Wu, Z. J., 2011, "The Use of Computational Fluid Dynamics in the Development of Ventricular Assist Devices," Med. Eng. Phys., 33, pp. 263-280.
    • (2011) Med. Eng. Phys. , vol.33 , pp. 263-280
    • Fraser, K.H.1    Taskin, M.E.2    Griffith, B.P.3    Wu, Z.J.4
  • 27
    • 0034940556 scopus 로고    scopus 로고
    • Particle image velocimetry measurements of blood velocity in a continuous flow ventricular assist device
    • Day, S. W., McDaniel, J. C., Wood, H. G., Allaire, P. E., Landrot, N., and Curtas, A., 2001, "Particle Image Velocimetry Measurements of Blood Velocity in a Continuous Flow Ventricular Assist Device," ASAIO J., 47, pp. 406-411. (Pubitemid 32655816)
    • (2001) ASAIO Journal , vol.47 , Issue.4 , pp. 406-411
    • Day, S.W.1    McDaniel, J.C.2    Wood, H.G.3    Allaire, P.E.4    Landrot, N.5    Curtas, A.6
  • 28
    • 10044288363 scopus 로고    scopus 로고
    • Leakage flow rate and wall shear stress distributions in a biocentrifugal ventricular assist device
    • DOI 10.1097/01.MAT.0000144363.92963.CB
    • Chua, L. P., Ong, K. S., Yu, C. M. S., and Zhou, T., 2004, "Leakage Flow Rate and Wall Shear Stress Distributions in a Biocentrifugal Ventricular Assist Device," ASAIO J., 50, pp. 530-536. (Pubitemid 39612522)
    • (2004) ASAIO Journal , vol.50 , Issue.6 , pp. 530-536
    • Leok, P.C.1    Kang, S.O.2    Yu, C.M.S.3    Zhou, T.4
  • 30
    • 0030017933 scopus 로고    scopus 로고
    • Application of computational fluid dynamics techniques to blood pumps
    • Sukumar, R., Ahavale, M. M., Makhijani, V. B., and Przekwas, A. J., 1996, "Application of Computational Fluid Dynamics Techniques to Blood Pumps," Artif. Organs, 20, pp. 529-533. (Pubitemid 26246657)
    • (1996) Artificial Organs , vol.20 , Issue.6 , pp. 529-533
    • Sukumar, R.1    Athavale, M.M.2    Makhijani, V.B.3    Przekwas, A.J.4
  • 31
    • 0029086396 scopus 로고
    • Computational flow optimization of rotary blood pump components
    • Antaki, J. F., Ghattas, O., Burgreen, G. W., He, B., 1995, "Computational Flow Optimization of Rotary Blood Pump Components," Artif. Organs, 19, pp. 608-615.
    • (1995) Artif. Organs , vol.19 , pp. 608-615
    • Antaki, J.F.1    Ghattas, O.2    Burgreen, G.W.3    He, B.4
  • 32
    • 84859615962 scopus 로고    scopus 로고
    • Computational model-based design of a wearable artificial pump-lung for cardiopulmonary/respiratory support
    • Wu, Z. J., Taskin, M. E., Zhang, T., Fraser, K. H., and Griffith, B. P., 2012, "Computational Model-Based Design of a Wearable Artificial Pump-Lung for Cardiopulmonary/Respiratory Support," Artif. Organs, 36, pp. 387-399.
    • (2012) Artif. Organs , vol.36 , pp. 387-399
    • Wu, Z.J.1    Taskin, M.E.2    Zhang, T.3    Fraser, K.H.4    Griffith, B.P.5
  • 33
    • 0035985035 scopus 로고    scopus 로고
    • Computational fluid dynamics and stent design
    • DOI 10.1046/j.1525-1594.2002.07084.x
    • Frank, A. O., Walsh, P. W., and Moore, J. E., Jr., 2002, "Computational Fluid Dynamics and Stent Design," Artif. Organs, 26, pp. 614-621. (Pubitemid 34779416)
    • (2002) Artificial Organs , vol.26 , Issue.7 , pp. 614-621
    • Frank, A.O.1    Walsh, P.W.2    Moore Jr., J.E.3
  • 34
    • 77951987684 scopus 로고    scopus 로고
    • Computational fluid dynamics analysis of thrombosis potential in ventricular assist device drainage cannulae
    • Fraser, K. H., Zhang, T., Taskin, M. E., Griffith, B. P., and Wu, Z. J., 2010, "Computational Fluid Dynamics Analysis of Thrombosis Potential in Ventricular Assist Device Drainage Cannulae," ASAIO J., 56, pp. 157-163.
    • (2010) ASAIO J. , vol.56 , pp. 157-163
    • Fraser, K.H.1    Zhang, T.2    Taskin, M.E.3    Griffith, B.P.4    Wu, Z.J.5
  • 36
    • 41149145906 scopus 로고    scopus 로고
    • Computational fluid dynamics investigation of a centrifugal blood pump
    • DOI 10.1111/j.1525-1594.2008.00552.x
    • Legendre, D., Antunes, P., Bock, E., Andrade, A., Biscegli, J. F., and Ortiz, J. P., 2008, "Computational Fluid Dynamics Investigation of a Centrifugal Blood Pump," Artif. Organs, 32, pp. 342-348. (Pubitemid 351442648)
    • (2008) Artificial Organs , vol.32 , Issue.4 , pp. 342-348
    • Legendre, D.1    Antunes, P.2    Bock, E.3    Andrade, A.4    Biscegli, J.F.5    Ortiz, J.P.6
  • 37
    • 27744605262 scopus 로고    scopus 로고
    • Numerical and experimental analysis of an axial flow left ventricular assist device: The influence of the diffuser on overall pump performance
    • DOI 10.1111/j.1525-1594.2005.29095.x
    • Untaroiu, A., Throckmorton, A. L., Patel, S. M., Wood, H. G., Allaire, P. E., and Olse, D. B., 2005, "Numerical and Experimental Analysis of an Axial Flow Left Ventricular Assist Device: The Influence of the Diffuser on Overall Pump Performance," Artif. Organs, 29, pp. 581-591. (Pubitemid 41602858)
    • (2005) Artificial Organs , vol.29 , Issue.7 , pp. 581-591
    • Untaroiu, A.1    Throckmorton, A.L.2    Patel, S.M.3    Wood, H.G.4    Allaire, P.E.5    Olsen, D.B.6
  • 38
    • 77952203682 scopus 로고    scopus 로고
    • Computational fluid dynamics analysis of blade tip clearances on hemodynamic performance and blood damage in a centrifugal ventricular assist device
    • Wu, J., Paden, B. E., Borovetz, H. S., and Antaki, J. F., 2010, "Computational Fluid Dynamics Analysis of Blade Tip Clearances on Hemodynamic Performance and Blood Damage in a Centrifugal Ventricular Assist Device," Artif. Organs, 34, pp. 402-411.
    • (2010) Artif. Organs , vol.34 , pp. 402-411
    • Wu, J.1    Paden, B.E.2    Borovetz, H.S.3    Antaki, J.F.4
  • 39
    • 78650042223 scopus 로고    scopus 로고
    • Computational characterization of flow and hemolytic performance of the ultramag blood pump for circulatory support
    • Taskin, M. E., Fraser, K. H., Zhang, T., Gellman, B., Fleischli, A., Dasse, K. A., Griffith, B. P., and Wu Z. J., 2011, "Computational Characterization of Flow and Hemolytic Performance of the UltraMag Blood Pump for Circulatory Support," Artif. Organs, 34, pp. 1099-1113.
    • (2011) Artif. Organs , vol.34 , pp. 1099-1113
    • Taskin, M.E.1    Fraser, K.H.2    Zhang, T.3    Gellman, B.4    Fleischli, A.5    Dasse, K.A.6    Griffith, B.P.7    Wu, Z.J.8
  • 41
    • 34250701082 scopus 로고    scopus 로고
    • Numerical simulation of an axial blood pump
    • DOI 10.1111/j.1525-1594.2007.00422.x
    • Chua, L. P., Su, B., Tau, M. L., and Zhou, T., 2007, "Numerical Simulation of an Axial Blood Pump," Artif. Organs, 31, pp. 560-570. (Pubitemid 46961711)
    • (2007) Artificial Organs , vol.31 , Issue.7 , pp. 560-570
    • Chua, L.P.1    Su, B.2    Lim, T.M.3    Zhou, T.4
  • 43
    • 33644993283 scopus 로고    scopus 로고
    • Computational and experimental evaluation of the fluid dynamics and hemocompatability of the centrimag blood pump
    • Zhang, J., Gellman, B., Koert, A., Dasse, K. A., Gilbert, R. J., Griffith, B. P., and Wu, Z. J., 2006, "Computational and Experimental Evaluation of the Fluid Dynamics and Hemocompatability of the Centrimag Blood Pump," Artif. Organs, 30, pp. 168-177.
    • (2006) Artif. Organs , vol.30 , pp. 168-177
    • Zhang, J.1    Gellman, B.2    Koert, A.3    Dasse, K.A.4    Gilbert, R.J.5    Griffith, B.P.6    Wu, Z.J.7
  • 44
    • 0000559492 scopus 로고    scopus 로고
    • Quantification of uncertainty in computational fluid dynamics
    • Roache, P. J., 1997, "Quantification of Uncertainty in Computational Fluid Dynamics," Ann. Rev. Fluid Mech., 29, pp. 123-160.
    • (1997) Ann. Rev. Fluid Mech. , vol.29 , pp. 123-160
    • Roache, P.J.1
  • 45
    • 0028486598 scopus 로고
    • Two-equation eddy-viscosity turbulence models for engineering applications
    • Menter, F. R., 1994, "Two-Equation Eddy-Viscosity Turbulence Models for Engineering Applications," AIAA J., 32, pp. 1598-1605. (Pubitemid 283214)
    • (1994) AIAA Journal , vol.32 , Issue.8 , pp. 1598-1605
    • Menter, F.R.1
  • 48
    • 0029090222 scopus 로고
    • Model for a general mechanical blood damage prediction
    • Bludszuweit, C., 1995, "Model for a General Mechanical Blood Damage Prediction," Artif. Organs, 19, pp. 583-598.
    • (1995) Artif. Organs , vol.19 , pp. 583-598
    • Bludszuweit, C.1
  • 49
    • 84863514397 scopus 로고    scopus 로고
    • Evaluation of eulerian and lagrangian models for hemolysis
    • Taskin, M. E., Fraser, K. H., Zhang, T., Wu, C., Griffith, B. P., and Wu, Z. J., 2012, "Evaluation of Eulerian and Lagrangian Models for Hemolysis," ASAIO J. 58 pp. 363-372.
    • (2012) ASAIO J. , vol.58 , pp. 363-372
    • Taskin, M.E.1    Fraser, K.H.2    Zhang, T.3    Wu, C.4    Griffith, B.P.5    Wu, Z.J.6
  • 50
    • 0019186014 scopus 로고
    • A couette viscometer for short time shearing of blood
    • Heuser, G., and Opitz, R., 1980, "A Couette Viscometer for Short Time Shearing of Blood," Biorheology, 17, pp. 17-24. (Pubitemid 10051159)
    • (1980) Biorheology , vol.17 , Issue.1-2 , pp. 17-24
    • Heuser, G.1    Opitz, R.2
  • 51
    • 82955161196 scopus 로고    scopus 로고
    • Study of flow-induced hemolysis using novel couette-Type blood shearing devices
    • Zhang, T., Taskin, M. E., Fang, H. B., Pampori, A., Jarvik, R., Griffith, B. P., and Wu Z. J., 2011, "Study of Flow-Induced Hemolysis Using Novel Couette-Type Blood Shearing Devices," Artif. Organs, 35, pp. 1180-1186.
    • (2011) Artif. Organs , vol.35 , pp. 1180-1186
    • Zhang, T.1    Taskin, M.E.2    Fang, H.B.3    Pampori, A.4    Jarvik, R.5    Griffith, B.P.6    Wu, Z.J.7
  • 52
    • 0242333304 scopus 로고    scopus 로고
    • Computational Fluid Dynamics Prediction of Blood Damage in a Centrifugal Pump
    • DOI 10.1046/j.1525-1594.2003.00026.x
    • Song, X., Throckmorton, A. L., Wood, H. G., Antaki, J. F., and Olsen, D. B., 2003, "Computational Fluid Dynamics Prediction of Blood Damage In a Centrifugal Pump," Artif. Organs, 27, pp. 938-941. (Pubitemid 37338804)
    • (2003) Artificial Organs , vol.27 , Issue.10 , pp. 938-941
    • Song, X.1    Throckmorton, A.L.2    Wood, H.G.3    Antaki, J.F.4    Olsen, D.B.5
  • 53
    • 84864859260 scopus 로고    scopus 로고
    • Standard practice for assessment of hemolysis in continuous flow blood pumps
    • American Society for Testing and Materials, West Conshohocken, PA
    • American Society for Testing and Materials, 1998, "Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps," Annual Book of ASTM Standards, West Conshohocken, PA, Vol. 13.01.
    • (1998) Annual Book of ASTM Standards , pp. 1301
  • 54
    • 84864832689 scopus 로고    scopus 로고
    • See supplementary material at, for: additional mesh study results; detailed descriptions of the flow fields and shear stress histograms for each operating condition; images showing the locations of high shear stress regions; histograms for residence time; and comparative sss and time results at optimum VAD conditions
    • See supplementary material at http://medschool.umaryland.edu/artificial- organs/pubs.asp for: additional mesh study results; detailed descriptions of the flow fields and shear stress histograms for each operating condition; images showing the locations of high shear stress regions; histograms for residence time; and comparative sss and time results at optimum VAD conditions.
  • 55
    • 10044259740 scopus 로고    scopus 로고
    • Correlation of in vivo clot deposition with the flow characteristics in the 50 cc Penn State Artificial Heart: A preliminary study
    • DOI 10.1097/01.MAT.0000145694.40637.A0
    • Hochareon, P., Manning, K. B., Fontaine, A. A., Tarbell, J. M., and Deutsch, S., 2004, "Correlation of in vivo Clot Deposition With the Flow Characteristics in the 50 cc Penn State Artificial Heart: A Preliminary Study," ASAIO J., 50, pp. 537-542. (Pubitemid 39612523)
    • (2004) ASAIO Journal , vol.50 , Issue.6 , pp. 537-542
    • Hochareon, P.1    Manning, K.B.2    Fontaine, A.A.3    Tarbell, J.M.4    Deutsch, S.5
  • 56
    • 34548183335 scopus 로고    scopus 로고
    • Flow-induced platelet activation and damage accumulation in a mechanical heart valve: Numerical studies
    • DOI 10.1111/j.1525-1594.2007.00446.x
    • Alemu, Y. and Bluestein, D., 2007, "Flow Induced Platelet Activation and Damage Accumulation in a Mechanical Heart Valve: Numerical Studies," Artif. Organs, 31, pp. 677-688. (Pubitemid 47304377)
    • (2007) Artificial Organs , vol.31 , Issue.9 , pp. 677-688
    • Alemu, Y.1    Bluestein, D.2
  • 57
    • 60949094794 scopus 로고    scopus 로고
    • Evaluation of platelet activation in patients supported by the jarvik 2000 high-rotational speed impeller ventricular assist device
    • Loffler, C., Straub, A., Bassler, N., Pernice, K., Beyersdorf, F., Bode, C., Siegenthaler, M. P., and Peter, K., 2009, "Evaluation of Platelet Activation in Patients Supported by the Jarvik 2000 High-Rotational Speed Impeller Ventricular Assist Device," J. Thorac. Cardiovasc. Surg., 137, pp. 736-741.
    • (2009) J. Thorac. Cardiovasc. Surg. , vol.137 , pp. 736-741
    • Loffler, C.1    Straub, A.2    Bassler, N.3    Pernice, K.4    Beyersdorf, F.5    Bode, C.6    Siegenthaler, M.P.7    Peter, K.8
  • 60
    • 0033929252 scopus 로고    scopus 로고
    • Paradoxical effects of viscosity on the VentrAssist rotary blood pump
    • DOI 10.1046/j.1525-1594.2000.06600.x
    • Vidakovic, S., Ayre, P., Woodard, J., Lingard, N., Tansley, G., and Reizes, J., 2000, "Paradoxical Effects of Viscosity on the VentrAssist Rotary Blood Pump," Artif. Organs, 24, pp. 478-482. (Pubitemid 30430511)
    • (2000) Artificial Organs , vol.24 , Issue.6 , pp. 478-482
    • Vidakovic, S.1    Ayre, P.2    Woodard, J.3    Lingard, N.4    Tansley, G.5    Reizes, J.6
  • 61
    • 0001331302 scopus 로고
    • The viscosity of the blood in narrow capillary tubes
    • Available at
    • Fahraeus, R. and Lindqvist, T., 1931, "The Viscosity of the Blood in Narrow Capillary Tubes," Am. J. Physiol., 96, pp. 562-568. Available at: http://ajplegacy.physiology. org/content/96/3/562
    • (1931) Am. J. Physiol. , vol.96 , pp. 562-568
    • Fahraeus, R.1    Lindqvist, T.2
  • 63
    • 70349342724 scopus 로고    scopus 로고
    • The importance of dq/dt on the flow field in a turbodynamic pump with pulsatile flow
    • Shu, F., Vandenberghe, S., and Antaki, J. F., 2009, "The Importance of dQ/dt on the Flow Field in a Turbodynamic Pump With Pulsatile Flow," Artif. Organs, 33, pp. 757-762.
    • (2009) Artif. Organs , vol.33 , pp. 757-762
    • Shu, F.1    Vandenberghe, S.2    Antaki, J.F.3
  • 64
    • 4544362831 scopus 로고    scopus 로고
    • Transient and quasi-steady computational fluid dynamics study of a left ventricular assist device
    • DOI 10.1097/01.MAT.0000136507.57707.0F
    • Song, X., Throckmorton, A. L., Wood, H. G., Allaire, P. E., and Olsen, D. B., 2004, "Transient and Quasi-Steady Computational Fluid Dynamics Study of a Left Ventricular Assist Device," ASAIO J., 50, pp. 410-417. (Pubitemid 39237948)
    • (2004) ASAIO Journal , vol.50 , Issue.5 , pp. 410-417
    • Song, X.1    Throckmorton, A.L.2    Wood, H.G.3    Allaire, P.E.4    Olsen, D.B.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.