메뉴 건너뛰기




Volumn 86, Issue 4, 2008, Pages 1227-1235

Improved Survival and Decreasing Incidence of Adverse Events With the HeartMate II Left Ventricular Assist Device as Bridge-to-Transplant Therapy

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; ALANINE AMINOTRANSFERASE; ASPARTATE AMINOTRANSFERASE; BILIRUBIN; CREATININE; HEPARIN; WARFARIN;

EID: 52049104955     PISSN: 00034975     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.athoracsur.2008.06.030     Document Type: Article
Times cited : (236)

References (34)
  • 1
    • 0035783884 scopus 로고    scopus 로고
    • Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation
    • Frazier O.H., Rose E.A., Oz M.C., et al. Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. J Thorac Cardiovasc Surg 122 (2001) 1186-1195
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 1186-1195
    • Frazier, O.H.1    Rose, E.A.2    Oz, M.C.3
  • 2
    • 24344473396 scopus 로고    scopus 로고
    • Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report-2005
    • International Society for Heart and Lung Transplantation
    • Deng M.C., Edwards L.B., Hertz M.I., et al., International Society for Heart and Lung Transplantation. Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: third annual report-2005. J Heart Lung Transplant 24 (2005) 1182
    • (2005) J Heart Lung Transplant , vol.24 , pp. 1182
    • Deng, M.C.1    Edwards, L.B.2    Hertz, M.I.3
  • 3
    • 0029113695 scopus 로고
    • Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system
    • Frazier O.H., Rose E.A., McCarthy P., et al. Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system. Ann Surg 222 (1995) 327-336
    • (1995) Ann Surg , vol.222 , pp. 327-336
    • Frazier, O.H.1    Rose, E.A.2    McCarthy, P.3
  • 4
    • 18244416554 scopus 로고    scopus 로고
    • Preoperative and postoperative comparison of patients with univentricular and biventricular support with the Thoratec ventricular assist device as a bridge to heart transplantation
    • Farrar D.J., Hill J.D., Pennington D.G., et al. Preoperative and postoperative comparison of patients with univentricular and biventricular support with the Thoratec ventricular assist device as a bridge to heart transplantation. J Thorac Cardiovasc Surg 113 (1997) 202-209
    • (1997) J Thorac Cardiovasc Surg , vol.113 , pp. 202-209
    • Farrar, D.J.1    Hill, J.D.2    Pennington, D.G.3
  • 5
    • 0035138879 scopus 로고    scopus 로고
    • Improved outcomes with an implantable left ventricular assist system: a multicenter study
    • Portner P.M., Jansen P.G., Oyer P.E., Wheldon D.R., and Ramasamy N. Improved outcomes with an implantable left ventricular assist system: a multicenter study. Ann Thorac Surg 71 (2001) 205-209
    • (2001) Ann Thorac Surg , vol.71 , pp. 205-209
    • Portner, P.M.1    Jansen, P.G.2    Oyer, P.E.3    Wheldon, D.R.4    Ramasamy, N.5
  • 6
    • 34249092461 scopus 로고    scopus 로고
    • Results of multicenter clinical trial with the Thoratec implantable ventricular assist device
    • Slaughter M.S., Tsui S.S., El-Banayosy A., et al. Results of multicenter clinical trial with the Thoratec implantable ventricular assist device. J Thorac Cardiovasc Surg 133 (2007) 1573-1580
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 1573-1580
    • Slaughter, M.S.1    Tsui, S.S.2    El-Banayosy, A.3
  • 7
    • 0035892018 scopus 로고    scopus 로고
    • Long-term mechanical left ventricular assistance for end-stage heart failure
    • Rose E.A., Gelijns A.C., Moskowitz A.J., et al. Long-term mechanical left ventricular assistance for end-stage heart failure. N Engl J Med 345 (2001) 1435-1443
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 8
    • 0035106218 scopus 로고    scopus 로고
    • HeartMate II left ventricular assist system: from concept to first clinical use
    • Griffith B.P., Kormos R.L., Borovetz H.S., et al. HeartMate II left ventricular assist system: from concept to first clinical use. Ann Thorac Surg 71 (2001) 116-120
    • (2001) Ann Thorac Surg , vol.71 , pp. 116-120
    • Griffith, B.P.1    Kormos, R.L.2    Borovetz, H.S.3
  • 9
    • 1642564243 scopus 로고    scopus 로고
    • Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection
    • Frazier O.H., Myers T.J., Westaby S., and Gregoric I.D. Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection. Ann Thorac Surg 77 (2004) 133-142
    • (2004) Ann Thorac Surg , vol.77 , pp. 133-142
    • Frazier, O.H.1    Myers, T.J.2    Westaby, S.3    Gregoric, I.D.4
  • 10
    • 34548311569 scopus 로고    scopus 로고
    • Use of a continuous-flow device in patients awaiting heart transplantation
    • Miller L.W., Pagani F.D., Russell S.D., et al. Use of a continuous-flow device in patients awaiting heart transplantation. N Engl J Med 357 (2007) 885-896
    • (2007) N Engl J Med , vol.357 , pp. 885-896
    • Miller, L.W.1    Pagani, F.D.2    Russell, S.D.3
  • 11
    • 0037123156 scopus 로고    scopus 로고
    • Left ventricular assist device therapy improves utilization of donor hearts
    • Aaronson K.D., Eppinger M.J., Dyke D.B., Wright S., and Pagani F.D. Left ventricular assist device therapy improves utilization of donor hearts. Ann Thorac Surg 39 (2004) 1247-1254
    • (2004) Ann Thorac Surg , vol.39 , pp. 1247-1254
    • Aaronson, K.D.1    Eppinger, M.J.2    Dyke, D.B.3    Wright, S.4    Pagani, F.D.5
  • 12
    • 2342437924 scopus 로고    scopus 로고
    • Bridging to transplant with the HeartMate left ventricular assist device: the Columbia Presbyterian 12-year experience
    • Morgan J.A., John R., Rao V., et al. Bridging to transplant with the HeartMate left ventricular assist device: the Columbia Presbyterian 12-year experience. J Thorac Cardiovasc Surg 127 (2004) 1309-1316
    • (2004) J Thorac Cardiovasc Surg , vol.127 , pp. 1309-1316
    • Morgan, J.A.1    John, R.2    Rao, V.3
  • 13
    • 33847245851 scopus 로고    scopus 로고
    • Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients
    • Feller E.D., Sorensen E.N., Haddad M., et al. Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Ann Thorac Surg 83 (2007) 1082-1088
    • (2007) Ann Thorac Surg , vol.83 , pp. 1082-1088
    • Feller, E.D.1    Sorensen, E.N.2    Haddad, M.3
  • 14
    • 35848952047 scopus 로고    scopus 로고
    • Initial clinical experience with the HeartMate II axial-flow left ventricular assist device
    • Frazier O.H., Gemmato C., Myers T.J., et al. Initial clinical experience with the HeartMate II axial-flow left ventricular assist device. Tex Heart Inst J 34 (2007) 275-281
    • (2007) Tex Heart Inst J , vol.34 , pp. 275-281
    • Frazier, O.H.1    Gemmato, C.2    Myers, T.J.3
  • 15
    • 34848923730 scopus 로고    scopus 로고
    • VentrAssist left ventricular assist device: clinical trial results and clinical development plan update
    • Esmore D., Spratt P., Larbalestier R., et al. VentrAssist left ventricular assist device: clinical trial results and clinical development plan update. Eur J Cardio Surg 32 (2007) 735-744
    • (2007) Eur J Cardio Surg , vol.32 , pp. 735-744
    • Esmore, D.1    Spratt, P.2    Larbalestier, R.3
  • 16
    • 52049103045 scopus 로고    scopus 로고
    • Strategies to reduce the incidence of LVAD-related infections
    • Jweied E., Joyce L., Liao K., and John R. Strategies to reduce the incidence of LVAD-related infections. J Heart Lung Transplant 27 Suppl (2008) 132
    • (2008) J Heart Lung Transplant , vol.27 , Issue.SUPPL , pp. 132
    • Jweied, E.1    Joyce, L.2    Liao, K.3    John, R.4
  • 17
    • 34548297997 scopus 로고    scopus 로고
    • Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection
    • Lietz K.L., Long J.W., Kfoury A.G., et al. Outcomes of left ventricular assist device implantation as destination therapy in the post-REMATCH era: implications for patient selection. Circulation 116 (2007) 497-505
    • (2007) Circulation , vol.116 , pp. 497-505
    • Lietz, K.L.1    Long, J.W.2    Kfoury, A.G.3
  • 18
    • 0345347290 scopus 로고
    • Artificial circulatory support with textured interior surfaces: a counterintuitive approach to minimize thromboembolism
    • Rose E.A., Levin H.R., Oz M.C., et al. Artificial circulatory support with textured interior surfaces: a counterintuitive approach to minimize thromboembolism. Circulation 90 (1994) II87-II91
    • (1994) Circulation , vol.90
    • Rose, E.A.1    Levin, H.R.2    Oz, M.C.3
  • 19
    • 0025140418 scopus 로고
    • Neointimal development on textured biomaterial surfaces during clinical use of an implantable left ventricular assist device
    • Graham T.R., Dasse K., Coumbe A., et al. Neointimal development on textured biomaterial surfaces during clinical use of an implantable left ventricular assist device. Eur J Cardiothoracic Surg 4 (1990) 182-190
    • (1990) Eur J Cardiothoracic Surg , vol.4 , pp. 182-190
    • Graham, T.R.1    Dasse, K.2    Coumbe, A.3
  • 20
    • 26444468857 scopus 로고    scopus 로고
    • High level of cerebral microembolization in patients supported with the DeBakey left ventricular assist device
    • Thoennissen N.H., Schneider M., Allroggen A., et al. High level of cerebral microembolization in patients supported with the DeBakey left ventricular assist device. J Thorac Cardiovasc Surg 130 (2005) 1159-1166
    • (2005) J Thorac Cardiovasc Surg , vol.130 , pp. 1159-1166
    • Thoennissen, N.H.1    Schneider, M.2    Allroggen, A.3
  • 21
    • 0033844106 scopus 로고    scopus 로고
    • Impact of current management practices on early and late death in more than 500 consecutive cardiac transplant recipients
    • John R., Rajasinghe H., Chen J.M., et al. Impact of current management practices on early and late death in more than 500 consecutive cardiac transplant recipients. Ann Surg 232 (2000) 302-311
    • (2000) Ann Surg , vol.232 , pp. 302-311
    • John, R.1    Rajasinghe, H.2    Chen, J.M.3
  • 22
    • 1642564239 scopus 로고    scopus 로고
    • Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support
    • Klotz S., Deng M.C., Stymann J., et al. Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Ann Thorac Surg 77 (2004) 143-150
    • (2004) Ann Thorac Surg , vol.77 , pp. 143-150
    • Klotz, S.1    Deng, M.C.2    Stymann, J.3
  • 23
    • 34748926436 scopus 로고    scopus 로고
    • Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices
    • Haft J., Armstrong W., Dyke D.B., et al. Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation 116 (2007) I8-I15
    • (2007) Circulation , vol.116
    • Haft, J.1    Armstrong, W.2    Dyke, D.B.3
  • 25
    • 33645081254 scopus 로고    scopus 로고
    • Amir O, Radovancevic B, Delgado RM, et al. Peripheral vascular reactivity in patients with pulsatile vs. axial flow left ventricular assist device support. J Heart Lung Transplant 2067;25:391-4.
    • Amir O, Radovancevic B, Delgado RM, et al. Peripheral vascular reactivity in patients with pulsatile vs. axial flow left ventricular assist device support. J Heart Lung Transplant 2067;25:391-4.
  • 26
    • 18844396181 scopus 로고    scopus 로고
    • Cellular and hemodynamic responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices
    • Thohan V., Stetson S.J., Nagueh S.F., et al. Cellular and hemodynamic responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. J Heart Lung Transplant 24 (2005) 566-575
    • (2005) J Heart Lung Transplant , vol.24 , pp. 566-575
    • Thohan, V.1    Stetson, S.J.2    Nagueh, S.F.3
  • 27
    • 40749128111 scopus 로고    scopus 로고
    • Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading
    • Garcia S., Kamdar F., Boyle A., et al. Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading. J Heart Lung Transplant 27 (2008) 261-267
    • (2008) J Heart Lung Transplant , vol.27 , pp. 261-267
    • Garcia, S.1    Kamdar, F.2    Boyle, A.3
  • 28
    • 2442465042 scopus 로고    scopus 로고
    • Implantable left ventricular assist device for treatment of pulmonary hypertension in candidates for orthotopic heart transplantation - a preliminary study
    • Martin J., Siegenthaler M.P., Friesewinkel O., et al. Implantable left ventricular assist device for treatment of pulmonary hypertension in candidates for orthotopic heart transplantation - a preliminary study. Eur J Cardiothorac Surg 25 (2004) 971-977
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 971-977
    • Martin, J.1    Siegenthaler, M.P.2    Friesewinkel, O.3
  • 29
    • 34247215492 scopus 로고    scopus 로고
    • Medically refractory pulmonary hypertension: treatment with nonpulsatile left ventricular assist devices
    • Etz C.D., Welp H.A., Tjan T.D., et al. Medically refractory pulmonary hypertension: treatment with nonpulsatile left ventricular assist devices. Ann Thorac Surg 83 (2007) 1697-1706
    • (2007) Ann Thorac Surg , vol.83 , pp. 1697-1706
    • Etz, C.D.1    Welp, H.A.2    Tjan, T.D.3
  • 30
    • 11844262604 scopus 로고    scopus 로고
    • Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device
    • Letsou G.V., Shah N., Gregoric I.D., Myers T.J., Delgado R., and Frazier O.H. Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device. J Heart Lung Transplant 24 (2005) 105-109
    • (2005) J Heart Lung Transplant , vol.24 , pp. 105-109
    • Letsou, G.V.1    Shah, N.2    Gregoric, I.D.3    Myers, T.J.4    Delgado, R.5    Frazier, O.H.6
  • 31
    • 0000428360 scopus 로고
    • Gastrointestinal bleeding in aortic stenosis [letter]
    • Heyde E.C. Gastrointestinal bleeding in aortic stenosis [letter]. N Engl J Med 259 (1958) 196
    • (1958) N Engl J Med , vol.259 , pp. 196
    • Heyde, E.C.1
  • 32
    • 0016174718 scopus 로고
    • Idiopathic gastrointestinal bleeding and aortic stenosis
    • Cody M.C., O'Donovan P.B., and Hughes Jr. R.W. Idiopathic gastrointestinal bleeding and aortic stenosis. Am J Dig Dis 19 (1974) 393-398
    • (1974) Am J Dig Dis , vol.19 , pp. 393-398
    • Cody, M.C.1    O'Donovan, P.B.2    Hughes Jr., R.W.3
  • 33
    • 0026725790 scopus 로고
    • Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand's disease the link?
    • Warkentin T.E., Moore J.C., and Morgan D.G. Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand's disease the link?. Lancet 340 (1992) 35-37
    • (1992) Lancet , vol.340 , pp. 35-37
    • Warkentin, T.E.1    Moore, J.C.2    Morgan, D.G.3
  • 34
    • 15344343618 scopus 로고    scopus 로고
    • Will left-ventricular assist device therapy replace heart transplantation in the foreseeable future?
    • Lietz K.L., and Miller L.W. Will left-ventricular assist device therapy replace heart transplantation in the foreseeable future?. Current Op Cardiol 20 (2005) 132
    • (2005) Current Op Cardiol , vol.20 , pp. 132
    • Lietz, K.L.1    Miller, L.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.