메뉴 건너뛰기




Volumn 25, Issue 4, 2006, Pages 384-390

Improved durability of the HeartMate XVE left ventricular assist device provides safe mechanical support up to 1 year but is associated with high risk of device failure in the second year

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; BLEEDING; CLINICAL ARTICLE; CONTROLLED STUDY; DEVICE INFECTION; DEVICE REMOVAL; EQUIPMENT DESIGN; FEMALE; HEART ASSIST DEVICE; HEART INJURY; HEART LEFT VENTRICLE; HEART TRANSPLANTATION; HEART VALVE; HUMAN; INCIDENCE; MALE; MATERIALS TESTING; MORTALITY; PRIORITY JOURNAL; PROSTHESIS FAILURE; RISK ASSESSMENT; SCORING SYSTEM; SURVIVAL RATE;

EID: 33645074465     PISSN: 10532498     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.healun.2005.11.437     Document Type: Article
Times cited : (40)

References (18)
  • 1
    • 0035100454 scopus 로고    scopus 로고
    • Advanced mechanical circulatory support with the HeartMate left ventricular assist device in the year 2000
    • J.W. Long Advanced mechanical circulatory support with the HeartMate left ventricular assist device in the year 2000 Ann Thorac Surg 71 suppl 2001 S176 S182
    • (2001) Ann Thorac Surg , vol.71 , Issue.SUPPL.
    • Long, J.W.1
  • 2
    • 0030894978 scopus 로고    scopus 로고
    • Bridge experience with long-term implantable left ventricular assist devices
    • M.C. Oz, M. Argenziano, K.A. Catanese Bridge experience with long-term implantable left ventricular assist devices Circulation 95 1997 1844 1852
    • (1997) Circulation , vol.95 , pp. 1844-1852
    • Oz, M.C.1    Argenziano, M.2    Catanese, K.A.3
  • 3
    • 0034062868 scopus 로고    scopus 로고
    • Novacor left ventricular assist system versus HeartMate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients: A prospective study
    • A. El-Banayosi, L. Arusoglu, L. Kizner Novacor left ventricular assist system versus HeartMate vented electric left ventricular assist system as a long-term mechanical circulatory support device in bridging patients a prospective study J Thorac Cardiovasc Surg 119 2000 581 587
    • (2000) J Thorac Cardiovasc Surg , vol.119 , pp. 581-587
    • El-Banayosi, A.1    Arusoglu, L.2    Kizner, L.3
  • 4
    • 0043239034 scopus 로고    scopus 로고
    • Outcome of patients surviving to heart transplantation after being mechanically bridged for more than 100 days
    • C. Schmid, H. Welp, S. Klotz Outcome of patients surviving to heart transplantation after being mechanically bridged for more than 100 days J Heart Lung Transplant 22 2003 1054 1058
    • (2003) J Heart Lung Transplant , vol.22 , pp. 1054-1058
    • Schmid, C.1    Welp, H.2    Klotz, S.3
  • 5
    • 14644399188 scopus 로고    scopus 로고
    • Relationship between bridging with ventricular assist device on rejection after heart transplantation
    • S.V. Pamboukian, M.R. Costanzo, S. Dunlap Relationship between bridging with ventricular assist device on rejection after heart transplantation J Heart Lung Transplant 24 2005 310 315
    • (2005) J Heart Lung Transplant , vol.24 , pp. 310-315
    • Pamboukian, S.V.1    Costanzo, M.R.2    Dunlap, S.3
  • 6
    • 0038799781 scopus 로고    scopus 로고
    • Recent improvements in outcome with the Novacor left ventricular assist device
    • J.T. Strauch, D. Spielvogel, P.L. Haldenwang Recent improvements in outcome with the Novacor left ventricular assist device J Heart Lung Transplant 22 2003 674 680
    • (2003) J Heart Lung Transplant , vol.22 , pp. 674-680
    • Strauch, J.T.1    Spielvogel, D.2    Haldenwang, P.L.3
  • 7
    • 33645080091 scopus 로고    scopus 로고
    • Thoratec Corporation Pleasanton, CA
    • Thoratec Registry 2004 Thoratec Corporation Pleasanton, CA
    • (2004) Thoratec Registry
  • 8
    • 0035892018 scopus 로고    scopus 로고
    • Long-term use of a left ventricular assist device for end-stage heart failure
    • E.A. Rose, A.C. Gelijns, A.J. Moskowitz Long-term use of a left ventricular assist device for end-stage heart failure N Engl J Med 345 2001 1435 1443
    • (2001) N Engl J Med , vol.345 , pp. 1435-1443
    • Rose, E.A.1    Gelijns, A.C.2    Moskowitz, A.J.3
  • 9
    • 0034626117 scopus 로고    scopus 로고
    • First permanent implant of the Jarvik 2000 Heart
    • S. Westaby, A.P. Banning, R. Jarvik First permanent implant of the Jarvik 2000 Heart Lancet 356 2000 900 903
    • (2000) Lancet , vol.356 , pp. 900-903
    • Westaby, S.1    Banning, A.P.2    Jarvik, R.3
  • 10
    • 0036895798 scopus 로고    scopus 로고
    • Adverse events in the use of HeartMate vented electric and Novacor left ventricular assist devices: Comparing apples and oranges
    • M.K. Pasque, J.G. Rogers Adverse events in the use of HeartMate vented electric and Novacor left ventricular assist devices comparing apples and oranges J Thorac Cardiovasc Surg 124 2002 1063 1067
    • (2002) J Thorac Cardiovasc Surg , vol.124 , pp. 1063-1067
    • Pasque, M.K.1    Rogers, J.G.2
  • 11
    • 2442613167 scopus 로고    scopus 로고
    • HeartMate VeLVAS design enhancements and its impact on device reliability
    • R.D. Dowling, S.J. Park, F.D. Pagani HeartMate VeLVAS design enhancements and its impact on device reliability Eur J Cardiothorac Surg 25 2004 958 963
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 958-963
    • Dowling, R.D.1    Park, S.J.2    Pagani, F.D.3
  • 12
    • 0030950627 scopus 로고    scopus 로고
    • Development and prospective validation of a clinical index to predict survival in ambulatory patients referred for cardiac transplant evaluation
    • K.D. Aaronson, J. Schwartz, T.M. Chen Development and prospective validation of a clinical index to predict survival in ambulatory patients referred for cardiac transplant evaluation Circulation 95 1997 2660 2667
    • (1997) Circulation , vol.95 , pp. 2660-2667
    • Aaronson, K.D.1    Schwartz, J.2    Chen, T.M.3
  • 13
    • 10944271912 scopus 로고    scopus 로고
    • Heart failure survival score continues to predict clinical outcomes in patients with heart failure receiving beta-blockers
    • T.M. Koelling, S. Joseph, K.D. Aaronson Heart failure survival score continues to predict clinical outcomes in patients with heart failure receiving beta-blockers J Heart Lung Transplant 23 2004 1414 1422
    • (2004) J Heart Lung Transplant , vol.23 , pp. 1414-1422
    • Koelling, T.M.1    Joseph, S.2    Aaronson, K.D.3
  • 14
    • 4243105976 scopus 로고    scopus 로고
    • Incidence and clinical management of life-threatening left ventricular assist device failure
    • E.J. Birks, P.D. Tansley, M.H. Yacoub Incidence and clinical management of life-threatening left ventricular assist device failure J Heart Lung Transplant 23 2004 964 969
    • (2004) J Heart Lung Transplant , vol.23 , pp. 964-969
    • Birks, E.J.1    Tansley, P.D.2    Yacoub, M.H.3
  • 15
    • 9344238774 scopus 로고    scopus 로고
    • Left ventricular assist device performance with long-term circulatory support: Lessons from the REMATCH trial
    • W.P. Dembitsky, A.J. Tector, S. Park Left ventricular assist device performance with long-term circulatory support lessons from the REMATCH trial Ann Thorac Surg 78 2004 2123 2130
    • (2004) Ann Thorac Surg , vol.78 , pp. 2123-2130
    • Dembitsky, W.P.1    Tector, A.J.2    Park, S.3
  • 16
    • 0036242943 scopus 로고    scopus 로고
    • Long-term follow-up of patients treated with an implantable left ventricular assist device as an extended bridge to heart transplantation
    • B. Peterzen, U. Lönn, K. Jansson Long-term follow-up of patients treated with an implantable left ventricular assist device as an extended bridge to heart transplantation J Heart Lung Transplant 21 2002 604 607
    • (2002) J Heart Lung Transplant , vol.21 , pp. 604-607
    • Peterzen, B.1    Lönn, U.2    Jansson, K.3
  • 17
    • 0000576204 scopus 로고    scopus 로고
    • Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist device
    • J.P. Slater, E.A. Rose, H.R. Levin Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist device Ann Thorac Surg 62 1996 1321 1328
    • (1996) Ann Thorac Surg , vol.62 , pp. 1321-1328
    • Slater, J.P.1    Rose, E.A.2    Levin, H.R.3
  • 18
    • 33645085208 scopus 로고    scopus 로고
    • A newly designed inflow valve conduit for the Thoratec HeartMate XVE (in vitro testing)
    • I.D. Gregoric, D. Tamez, O. Bataille A newly designed inflow valve conduit for the Thoratec HeartMate XVE (in vitro testing) ASAIO J 49 2003 166
    • (2003) ASAIO J , vol.49 , pp. 166
    • Gregoric, I.D.1    Tamez, D.2    Bataille, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.