-
1
-
-
0034145982
-
A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)
-
Ward KM, Aletras AH, Balaban RS. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). J Magn Reson 2000; 143(1): 79-87.
-
(2000)
J Magn Reson
, vol.143
, Issue.1
, pp. 79-87
-
-
Ward, K.M.1
Aletras, A.H.2
Balaban, R.S.3
-
2
-
-
0141564015
-
Novel pH-reporter MRI contrast agents
-
Aime S, Delli Castelli D, Terreno E. Novel pH-reporter MRI contrast agents. Angew Chem 2002; 114(22): 4510-4512.
-
(2002)
Angew Chem
, vol.114
, Issue.22
, pp. 4510-4512
-
-
Aime, S.1
Delli Castelli, D.2
Terreno, E.3
-
3
-
-
0033766573
-
Determination of pH using water protons and chemical exchange dependent saturation transfer (CEST)
-
Ward KM, Balaban RS. Determination of pH using water protons and chemical exchange dependent saturation transfer (CEST). Magn Reson Med 2000; 44(5): 799-802.
-
(2000)
Magn Reson Med
, vol.44
, Issue.5
, pp. 799-802
-
-
Ward, K.M.1
Balaban, R.S.2
-
4
-
-
67651124752
-
Responsive MRI agents for sensing metabolism in vivo
-
De Leon-Rodriguez LM, Lubag AJM, Malloy CR, Martinez GV, Gillies RJ, Sherry AD. Responsive MRI agents for sensing metabolism in vivo. Acc Chem Res 2009; 42(7): 948-957.
-
(2009)
Acc Chem Res
, vol.42
, Issue.7
, pp. 948-957
-
-
De Leon-Rodriguez, L.M.1
Lubag, A.J.M.2
Malloy, C.R.3
Martinez, G.V.4
Gillies, R.J.5
Sherry, A.D.6
-
5
-
-
53549113087
-
New 'multicolor' polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRI
-
McMahon MT, Gilad AA, DeLiso MA, Berman SM, Bulte JW, van Zijl PC. New 'multicolor' polypeptide diamagnetic chemical exchange saturation transfer (DIACEST) contrast agents for MRI. Magn Reson Med 2008; 60(4): 803-812.
-
(2008)
Magn Reson Med
, vol.60
, Issue.4
, pp. 803-812
-
-
McMahon, M.T.1
Gilad, A.A.2
DeLiso, M.A.3
Berman, S.M.4
Bulte, J.W.5
van Zijl, P.C.6
-
6
-
-
17044392297
-
Tunable imaging of cells labeled with MRI-PARACEST agents
-
Aime S, Carrera C, Delli Castelli D, Geninatti Crich S, Terreno E. Tunable imaging of cells labeled with MRI-PARACEST agents. Angew Chem Int Edn 2005; 44(12): 1813-1815.
-
(2005)
Angew Chem Int Edn
, vol.44
, Issue.12
, pp. 1813-1815
-
-
Aime, S.1
Carrera, C.2
Delli Castelli, D.3
Geninatti Crich, S.4
Terreno, E.5
-
7
-
-
72949107183
-
Multi-frequency PARACEST agents based on europium(III)-DOTA-tetraamide ligands
-
Viswanathan S, Ratnakar SJ, Green KN, Kovacs Z, De Leon-Rodriguez LM, Sherry AD. Multi-frequency PARACEST agents based on europium(III)-DOTA-tetraamide ligands. Angew Chem 2009; 48(49): 9330-9333.
-
(2009)
Angew Chem
, vol.48
, Issue.49
, pp. 9330-9333
-
-
Viswanathan, S.1
Ratnakar, S.J.2
Green, K.N.3
Kovacs, Z.4
De Leon-Rodriguez, L.M.5
Sherry, A.D.6
-
8
-
-
79952782590
-
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
-
van Zijl PC, Yadav NN. Chemical exchange saturation transfer (CEST): what is in a name and what isn't? Magn Reson Med 2011; 65(4): 927-948.
-
(2011)
Magn Reson Med
, vol.65
, Issue.4
, pp. 927-948
-
-
van Zijl, P.C.1
Yadav, N.N.2
-
9
-
-
84879555302
-
Nuts and bolts of chemical exchange saturation transfer MRI
-
Liu G, Song X, Chan KW, McMahon MT. Nuts and bolts of chemical exchange saturation transfer MRI. NMR Biomed 2013; 26(7): 810-828.
-
(2013)
NMR Biomed
, vol.26
, Issue.7
, pp. 810-828
-
-
Liu, G.1
Song, X.2
Chan, K.W.3
McMahon, M.T.4
-
10
-
-
84879540484
-
Nanoparticle-based chemical exchange saturation transfer (CEST) agents
-
Castelli DD, Terreno E, Longo D, Aime S. Nanoparticle-based chemical exchange saturation transfer (CEST) agents. NMR Biomed 2013; 26(7): 839-849.
-
(2013)
NMR Biomed
, vol.26
, Issue.7
, pp. 839-849
-
-
Castelli, D.D.1
Terreno, E.2
Longo, D.3
Aime, S.4
-
11
-
-
84879542786
-
Advantages of paramagnetic chemical exchange saturation transfer (CEST) complexes having slow to intermediate water exchange properties as responsive MRI agents
-
Soesbe TC, Wu Y, Dean Sherry A. Advantages of paramagnetic chemical exchange saturation transfer (CEST) complexes having slow to intermediate water exchange properties as responsive MRI agents. NMR Biomed 2013; 26(7): 829-838.
-
(2013)
NMR Biomed
, vol.26
, Issue.7
, pp. 829-838
-
-
Soesbe, T.C.1
Wu, Y.2
Dean, S.A.3
-
12
-
-
84870058718
-
Natural D-glucose as a biodegradable MRI contrast agent for detecting cancer
-
Chan KW, McMahon MT, Kato Y, Liu G, Bulte JW, Bhujwalla ZM, Artemov D, van Zijl PC. Natural D-glucose as a biodegradable MRI contrast agent for detecting cancer. Magn Reson Med 2012; 68(6): 1764-1773.
-
(2012)
Magn Reson Med
, vol.68
, Issue.6
, pp. 1764-1773
-
-
Chan, K.W.1
McMahon, M.T.2
Kato, Y.3
Liu, G.4
Bulte, J.W.5
Bhujwalla, Z.M.6
Artemov, D.7
van Zijl, P.C.8
-
13
-
-
84882272075
-
In vivo imaging of glucose uptake and metabolism in tumors
-
Walker-Samuel S, Ramasawmy R, Torrealdea F, Rega M, Rajkumar V, Johnson SP, Richardson S, Goncalves M, Parkes HG, Arstad E, Thomas DL, Pedley RB, Lythgoe MF, Golay X. In vivo imaging of glucose uptake and metabolism in tumors. Nat Med 2013; 19(18): 1067-1072.
-
(2013)
Nat Med
, vol.19
, Issue.18
, pp. 1067-1072
-
-
Walker-Samuel, S.1
Ramasawmy, R.2
Torrealdea, F.3
Rega, M.4
Rajkumar, V.5
Johnson, S.P.6
Richardson, S.7
Goncalves, M.8
Parkes, H.G.9
Arstad, E.10
Thomas, D.L.11
Pedley, R.B.12
Lythgoe, M.F.13
Golay, X.14
-
14
-
-
79954591390
-
Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons
-
Jin T, Autio J, Obata T, Kim S-G. Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons. Magn Reson Med 2011; 65(5): 1448-1460.
-
(2011)
Magn Reson Med
, vol.65
, Issue.5
, pp. 1448-1460
-
-
Jin, T.1
Autio, J.2
Obata, T.3
Kim, S.-G.4
-
15
-
-
34248376979
-
MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST)
-
van Zijl PC, Jones CK, Ren J, Malloy CR, Sherry AD. MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST). Proc Natl Acad Sci USA 2007; 104(11): 4359-4364.
-
(2007)
Proc Natl Acad Sci USA
, vol.104
, Issue.11
, pp. 4359-4364
-
-
van Zijl, P.C.1
Jones, C.K.2
Ren, J.3
Malloy, C.R.4
Sherry, A.D.5
-
16
-
-
78650205555
-
In vivo mapping of brain myo-inositol
-
Haris M, Cai K, Singh A, Hariharan H, Reddy R. In vivo mapping of brain myo-inositol. Neuroimage 2011; 54(3): 2079-2085.
-
(2011)
Neuroimage
, vol.54
, Issue.3
, pp. 2079-2085
-
-
Haris, M.1
Cai, K.2
Singh, A.3
Hariharan, H.4
Reddy, R.5
-
17
-
-
84863394212
-
Magnetic resonance imaging of glutamate
-
Cai K, Haris M, Singh A, Kogan F, Greenberg JH, Hariharan H, Detre JA, Reddy R. Magnetic resonance imaging of glutamate. Nat Med 2012; 18(2): 302-306.
-
(2012)
Nat Med
, vol.18
, Issue.2
, pp. 302-306
-
-
Cai, K.1
Haris, M.2
Singh, A.3
Kogan, F.4
Greenberg, J.H.5
Hariharan, H.6
Detre, J.A.7
Reddy, R.8
-
18
-
-
84868150699
-
Exchange rates of creatine kinase metabolites: feasibility of imaging creatine by chemical exchange saturation transfer MRI
-
Haris M, Nanga RP, Singh A, Cai K, Kogan F, Hariharan H, Reddy R. Exchange rates of creatine kinase metabolites: feasibility of imaging creatine by chemical exchange saturation transfer MRI. NMR Biomed 2012; 25(11): 1305-1309.
-
(2012)
NMR Biomed
, vol.25
, Issue.11
, pp. 1305-1309
-
-
Haris, M.1
Nanga, R.P.2
Singh, A.3
Cai, K.4
Kogan, F.5
Hariharan, H.6
Reddy, R.7
-
19
-
-
84896513600
-
Method for high-resolution imaging of creatine in vivo using chemical exchange saturation transfer
-
Kogan F, Haris M, Singh A, Cai K, Debrosse C, Nanga RP, Hariharan H, Reddy R. Method for high-resolution imaging of creatine in vivo using chemical exchange saturation transfer. Magn Reson Med 2013.
-
(2013)
Magn Reson Med
-
-
Kogan, F.1
Haris, M.2
Singh, A.3
Cai, K.4
Debrosse, C.5
Nanga, R.P.6
Hariharan, H.7
Reddy, R.8
-
20
-
-
84875461186
-
MRI-detectable pH nanosensors incorporated into hydrogels for in vivo sensing of transplanted-cell viability
-
Chan KW, Liu G, Song X, Kim H, Yu T, Arifin DR, Gilad AA, Hanes J, Walczak P, van Zijl PC, Bulte JW, McMahon MT. MRI-detectable pH nanosensors incorporated into hydrogels for in vivo sensing of transplanted-cell viability. Nat Mater 2013; 12(3): 268-275.
-
(2013)
Nat Mater
, vol.12
, Issue.3
, pp. 268-275
-
-
Chan, K.W.1
Liu, G.2
Song, X.3
Kim, H.4
Yu, T.5
Arifin, D.R.6
Gilad, A.A.7
Hanes, J.8
Walczak, P.9
van Zijl, P.C.10
Bulte, J.W.11
McMahon, M.T.12
-
21
-
-
84859104671
-
In vivo multicolor molecular MR imaging using diamagnetic chemical exchange saturation transfer liposomes
-
Liu G, Moake M, Har-el YE, Long CM, Chan KW, Cardona A, Jamil M, Walczak P, Gilad AA, Sgouros G, van Zijl PC, Bulte JW, McMahon MT. In vivo multicolor molecular MR imaging using diamagnetic chemical exchange saturation transfer liposomes. Magn Reson Med 2012; 67(4): 1106-1113.
-
(2012)
Magn Reson Med
, vol.67
, Issue.4
, pp. 1106-1113
-
-
Liu, G.1
Moake, M.2
Har-el, Y.E.3
Long, C.M.4
Chan, K.W.5
Cardona, A.6
Jamil, M.7
Walczak, P.8
Gilad, A.A.9
Sgouros, G.10
van Zijl, P.C.11
Bulte, J.W.12
McMahon, M.T.13
-
22
-
-
84856010278
-
Assessment of glycosaminoglycan concentration changes in the intervertebral disc via chemical exchange saturation transfer
-
Saar G, Zhang B, Ling W, Regatte RR, Navon G, Jerschow A. Assessment of glycosaminoglycan concentration changes in the intervertebral disc via chemical exchange saturation transfer. NMR Biomed 2012; 25(2): 255-261.
-
(2012)
NMR Biomed
, vol.25
, Issue.2
, pp. 255-261
-
-
Saar, G.1
Zhang, B.2
Ling, W.3
Regatte, R.R.4
Navon, G.5
Jerschow, A.6
-
23
-
-
40649092354
-
Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST)
-
Ling W, Regatte RR, Navon G, Jerschow A. Assessment of glycosaminoglycan concentration in vivo by chemical exchange-dependent saturation transfer (gagCEST). Proc Natl Acad Sci USA 2008; 105(7): 2266-2270.
-
(2008)
Proc Natl Acad Sci USA
, vol.105
, Issue.7
, pp. 2266-2270
-
-
Ling, W.1
Regatte, R.R.2
Navon, G.3
Jerschow, A.4
-
24
-
-
33846853038
-
Artificial reporter gene providing MRI contrast based on proton exchange
-
Gilad AA, McMahon MT, Walczak P, Winnard PT Jr, Raman V, van Laarhoven HW, Skoglund CM, Bulte JW, van Zijl PC. Artificial reporter gene providing MRI contrast based on proton exchange. Nat Biotechnol 2007; 25(2): 217-219.
-
(2007)
Nat Biotechnol
, vol.25
, Issue.2
, pp. 217-219
-
-
Gilad, A.A.1
McMahon, M.T.2
Walczak, P.3
Winnard, P.T.4
Raman, V.5
van Laarhoven, H.W.6
Skoglund, C.M.7
Bulte, J.W.8
van Zijl, P.C.9
-
25
-
-
0345600052
-
Amide proton transfer (APT) contrast for imaging of brain tumors
-
Zhou J, Lal B, Wilson DA, Laterra J, van Zijl PC. Amide proton transfer (APT) contrast for imaging of brain tumors. Magn Reson Med 2003; 50(6): 1120-1126.
-
(2003)
Magn Reson Med
, vol.50
, Issue.6
, pp. 1120-1126
-
-
Zhou, J.1
Lal, B.2
Wilson, D.A.3
Laterra, J.4
van Zijl, P.C.5
-
26
-
-
84870064437
-
MRI biosensor for protein kinase A encoded by a single synthetic gene
-
Airan RD, Bar-Shir A, Liu G, Pelled G, McMahon MT, van Zijl PC, Bulte JW, Gilad AA. MRI biosensor for protein kinase A encoded by a single synthetic gene. Magn Reson Med 2012; 68(6): 1919-1923.
-
(2012)
Magn Reson Med
, vol.68
, Issue.6
, pp. 1919-1923
-
-
Airan, R.D.1
Bar-Shir, A.2
Liu, G.3
Pelled, G.4
McMahon, M.T.5
van Zijl, P.C.6
Bulte, J.W.7
Gilad, A.A.8
-
27
-
-
77956516259
-
CEST and PARACEST MR contrast agents
-
Hancu I, Dixon WT, Woods M, Vinogradov E, Sherry AD, Lenkinski RE. CEST and PARACEST MR contrast agents. Acta Radiol 2010; 51(8): 910-923.
-
(2010)
Acta Radiol
, vol.51
, Issue.8
, pp. 910-923
-
-
Hancu, I.1
Dixon, W.T.2
Woods, M.3
Vinogradov, E.4
Sherry, A.D.5
Lenkinski, R.E.6
-
28
-
-
84873851132
-
Transforming thymidine into a magnetic resonance imaging probe for monitoring gene expression
-
Bar-Shir A, Liu G, Liang Y, Yadav NN, McMahon MT, Walczak P, Nimmagadda S, Pomper MG, Tallman KA, Greenberg MM, van Zijl PC, Bulte JW, Gilad AA. Transforming thymidine into a magnetic resonance imaging probe for monitoring gene expression. J Am Chem Soc 2013; 135(4): 1617-1624.
-
(2013)
J Am Chem Soc
, vol.135
, Issue.4
, pp. 1617-1624
-
-
Bar-Shir, A.1
Liu, G.2
Liang, Y.3
Yadav, N.N.4
McMahon, M.T.5
Walczak, P.6
Nimmagadda, S.7
Pomper, M.G.8
Tallman, K.A.9
Greenberg, M.M.10
van Zijl, P.C.11
Bulte, J.W.12
Gilad, A.A.13
-
29
-
-
16444378910
-
Iopamidol: Exploring the potential use of a well-established X-ray contrast agent for MRI
-
Aime S, Calabi L, Biondi L, De Miranda M, Ghelli S, Paleari L, Rebaudengo C, Terreno E. Iopamidol: Exploring the potential use of a well-established X-ray contrast agent for MRI. Magn Reson Med 2005; 53(4): 830-834.
-
(2005)
Magn Reson Med
, vol.53
, Issue.4
, pp. 830-834
-
-
Aime, S.1
Calabi, L.2
Biondi, L.3
De Miranda, M.4
Ghelli, S.5
Paleari, L.6
Rebaudengo, C.7
Terreno, E.8
-
30
-
-
79952784831
-
Iopamidol as a responsive MRI-chemical exchange saturation transfer contrast agent for pH mapping of kidneys: in vivo studies in mice at 7 T
-
Longo DL, Dastru W, Digilio G, Keupp J, Langereis S, Lanzardo S, Prestigio S, Steinbach O, Terreno E, Uggeri F, Aime S. Iopamidol as a responsive MRI-chemical exchange saturation transfer contrast agent for pH mapping of kidneys: in vivo studies in mice at 7 T. Magn Reson Med 2011; 65(1): 202-211.
-
(2011)
Magn Reson Med
, vol.65
, Issue.1
, pp. 202-211
-
-
Longo, D.L.1
Dastru, W.2
Digilio, G.3
Keupp, J.4
Langereis, S.5
Lanzardo, S.6
Prestigio, S.7
Steinbach, O.8
Terreno, E.9
Uggeri, F.10
Aime, S.11
-
31
-
-
84880835488
-
Salicylic acid and analogs: diamagnetic chemical exchange satuation transfer (diaCEST) magnetic resonance imaging (MRI) contrast agents with highly shifted exchangeable protons
-
Yang X, Song X, Li Y, Liu G, Ray Banerjee S, Pomper MG, McMahon MT. Salicylic acid and analogs: diamagnetic chemical exchange satuation transfer (diaCEST) magnetic resonance imaging (MRI) contrast agents with highly shifted exchangeable protons. Angew Chemie Int Edn 2013; 52(31): 8116-8119.
-
(2013)
Angew Chemie Int Edn
, vol.52
, Issue.31
, pp. 8116-8119
-
-
Yang, X.1
Song, X.2
Li, Y.3
Liu, G.4
Ray Banerjee, S.5
Pomper, M.G.6
McMahon, M.T.7
-
32
-
-
84932887841
-
Carbon-13 chemical shifts + intramolecular hydrogen bonding
-
Maciel GE, Savitsky GB. Carbon-13 chemical shifts + intramolecular hydrogen bonding. J Phys Chem 1964; 68(2): 437.
-
(1964)
J Phys Chem
, vol.68
, Issue.2
, pp. 437
-
-
Maciel, G.E.1
Savitsky, G.B.2
-
33
-
-
0035831968
-
Low barrier hydrogen bonds within salicylate mono-anions
-
Mock WL, Morsch LA. Low barrier hydrogen bonds within salicylate mono-anions. Tetrahedron 2001; 57(15): 2957-2964.
-
(2001)
Tetrahedron
, vol.57
, Issue.15
, pp. 2957-2964
-
-
Mock, W.L.1
Morsch, L.A.2
-
34
-
-
33645772151
-
Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-l-lysine and a starburst dendrimer
-
McMahon MT, Gilad AA, Zhou J, Sun PZ, Bulte JW, van Zijl PC. Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): Ph calibration for poly-l-lysine and a starburst dendrimer. Magn Reson Med 2006; 55(4): 836-847.
-
(2006)
Magn Reson Med
, vol.55
, Issue.4
, pp. 836-847
-
-
McMahon, M.T.1
Gilad, A.A.2
Zhou, J.3
Sun, P.Z.4
Bulte, J.W.5
van Zijl, P.C.6
-
35
-
-
1642357433
-
Crystal structures of prostaglandin D-2 11-ketoreductase (AKR1C3) in complex with the nonsteroidal anti-inflammatory drugs flufenamic acid and indomethacin
-
Lovering AL, Ride JP, Bunce CM, Desmond JC, Cummings SM, White SA. Crystal structures of prostaglandin D-2 11-ketoreductase (AKR1C3) in complex with the nonsteroidal anti-inflammatory drugs flufenamic acid and indomethacin. Cancer Res 2004; 64(5): 1802-1810.
-
(2004)
Cancer Res
, vol.64
, Issue.5
, pp. 1802-1810
-
-
Lovering, A.L.1
Ride, J.P.2
Bunce, C.M.3
Desmond, J.C.4
Cummings, S.M.5
White, S.A.6
-
36
-
-
67651089633
-
Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies
-
Ali MM, Liu G, Shah T, Flask CA, Pagel MD. Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies. Acc Chem Res 2009; 42(7): 915-924.
-
(2009)
Acc Chem Res
, vol.42
, Issue.7
, pp. 915-924
-
-
Ali, M.M.1
Liu, G.2
Shah, T.3
Flask, C.A.4
Pagel, M.D.5
-
37
-
-
84876700384
-
Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7T
-
Jones CK, Huang A, Xu J, Edden RA, Schar M, Hua J, Oskolkov N, Zaca D, Zhou J, McMahon MT, Pillai JJ, van Zijl PC. Nuclear Overhauser enhancement (NOE) imaging in the human brain at 7T. Neuroimage 2013; 77: 114-124.
-
(2013)
Neuroimage
, vol.77
, pp. 114-124
-
-
Jones, C.K.1
Huang, A.2
Xu, J.3
Edden, R.A.4
Schar, M.5
Hua, J.6
Oskolkov, N.7
Zaca, D.8
Zhou, J.9
McMahon, M.T.10
Pillai, J.J.11
van Zijl, P.C.12
-
38
-
-
0030049337
-
Perfusion imaging with compensation for asymmetric magnetization transfer effects
-
Pekar J, Jezzard P, Roberts DA, Leigh JS, Jr., Frank JA, McLaughlin AC. Perfusion imaging with compensation for asymmetric magnetization transfer effects. Magn Reson Med 1996; 35(1): 70-79.
-
(1996)
Magn Reson Med
, vol.35
, Issue.1
, pp. 70-79
-
-
Pekar, J.1
Jezzard, P.2
Roberts, D.A.3
Leigh, J.S.4
Frank, J.A.5
McLaughlin, A.C.6
-
39
-
-
84863154445
-
Imaging in vivo extracellular pH with a single paramagnetic chemical exchange saturation transfer magnetic resonance imaging contrast agent
-
Liu GS, Li YG, Sheth VR, Pagel MD. Imaging in vivo extracellular pH with a single paramagnetic chemical exchange saturation transfer magnetic resonance imaging contrast agent. Mol Imag 2012; 11(1): 47-57.
-
(2012)
Mol Imag
, vol.11
, Issue.1
, pp. 47-57
-
-
Liu, G.S.1
Li, Y.G.2
Sheth, V.R.3
Pagel, M.D.4
-
40
-
-
77951553892
-
Encoding the frequency dependence in MRI contrast media: the emerging class of CEST agents
-
Terreno E, Castelli DD, Aime S. Encoding the frequency dependence in MRI contrast media: the emerging class of CEST agents. Contrast Media Mol Imag 2010; 5(2): 78-98.
-
(2010)
Contrast Media Mol Imag
, vol.5
, Issue.2
, pp. 78-98
-
-
Terreno, E.1
Castelli, D.D.2
Aime, S.3
-
41
-
-
50249145152
-
Chemical exchange saturation transfer contrast agents for magnetic resonance imaging
-
Sherry AD, Woods M. Chemical exchange saturation transfer contrast agents for magnetic resonance imaging. Annu Rev Biomed Eng 2008; 10: 391-411.
-
(2008)
Annu Rev Biomed Eng
, vol.10
, pp. 391-411
-
-
Sherry, A.D.1
Woods, M.2
-
42
-
-
46749158331
-
Detection of enzymatic activity by PARACEST MRI: a general approach to target a large variety of enzymes
-
Chauvin T, Durand P, Bernier M, Meudal H, Doan B-T, Noury F, Badet B, Beloeil J-C, Tóth É. Detection of enzymatic activity by PARACEST MRI: a general approach to target a large variety of enzymes. Angew Chem Int Edn 2008; 47(23): 4370-4372.
-
(2008)
Angew Chem Int Edn
, vol.47
, Issue.23
, pp. 4370-4372
-
-
Chauvin, T.1
Durand, P.2
Bernier, M.3
Meudal, H.4
Doan, B.-T.5
Noury, F.6
Badet, B.7
Beloeil, J.-C.8
Tóth, E.9
-
43
-
-
33750319936
-
Molecular imaging using a targeted magnetic resonance hyperpolarized biosensor
-
Schroder L, Lowery TJ, Hilty C, Wemmer DE, Pines A. Molecular imaging using a targeted magnetic resonance hyperpolarized biosensor. Science 2006; 314(5798): 446-449.
-
(2006)
Science
, vol.314
, Issue.5798
, pp. 446-449
-
-
Schroder, L.1
Lowery, T.J.2
Hilty, C.3
Wemmer, D.E.4
Pines, A.5
-
44
-
-
84896548266
-
The Hanes-Woolf linear QUESP method improves the measurements of fast chemical exchange rates with CEST MRI
-
Randtke EA, Chen LQ, Corrales LR, Pagel MD. The Hanes-Woolf linear QUESP method improves the measurements of fast chemical exchange rates with CEST MRI. Magn Reson Med. DOI: 10.1002/mrm.24792.
-
Magn Reson Med
-
-
Randtke, E.A.1
Chen, L.Q.2
Corrales, L.R.3
Pagel, M.D.4
-
45
-
-
84859103883
-
Simplified quantification of labile proton concentration-weighted chemical exchange rate (k(ws)) with RF saturation time dependent ratiometric analysis (QUESTRA): normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI
-
Sun PZ. Simplified quantification of labile proton concentration-weighted chemical exchange rate (k(ws)) with RF saturation time dependent ratiometric analysis (QUESTRA): normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI. Magn Reson Med 2012; 67(4): 936-942.
-
(2012)
Magn Reson Med
, vol.67
, Issue.4
, pp. 936-942
-
-
Sun, P.Z.1
|