메뉴 건너뛰기




Volumn 71, Issue 4, 2014, Pages 1603-1612

The Hanes-Woolf linear QUESP method improves the measurements of fast chemical exchange rates with CEST MRI

Author keywords

Bloch; chemical exchange rates; chemical exchange saturation transfer; MRI; omega plot; QUESP; QUEST

Indexed keywords

FINANCE; MAGNETIC RESONANCE IMAGING;

EID: 84896548266     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24792     Document Type: Article
Times cited : (49)

References (25)
  • 1
    • 38449089092 scopus 로고    scopus 로고
    • An overview of responsive MRI contrast agents for molecular imaging
    • Yoo B, Pagel MD,. An overview of responsive MRI contrast agents for molecular imaging. Front Biosci 2007; 13: 1733-1752.
    • (2007) Front Biosci , vol.13 , pp. 1733-1752
    • Yoo, B.1    Pagel, M.D.2
  • 2
    • 84863154445 scopus 로고    scopus 로고
    • Imaging in vivo extracellular pH with a single PARACEST MRI contrast agent
    • Liu G, Li Y, Sheth VR, Pagel MD,. Imaging in vivo extracellular pH with a single PARACEST MRI contrast agent. Mol Imaging 2012; 11: 47-57.
    • (2012) Mol Imaging , vol.11 , pp. 47-57
    • Liu, G.1    Li, Y.2    Sheth, V.R.3    Pagel, M.D.4
  • 3
    • 49049101091 scopus 로고    scopus 로고
    • Imaging pH using the chemical exchange saturation transfer (CEST) MRI: Correction of concomitant RF irradiation effects to quantify CST MRI for chemical exchange rate and pH
    • Sun PZ, Sorensen AG,. Imaging pH using the chemical exchange saturation transfer (CEST) MRI: correction of concomitant RF irradiation effects to quantify CST MRI for chemical exchange rate and pH. Magn Reson Med 2008; 60: 390-397.
    • (2008) Magn Reson Med , vol.60 , pp. 390-397
    • Sun, P.Z.1    Sorensen, A.G.2
  • 4
    • 72449142598 scopus 로고    scopus 로고
    • Simultaneous determination of labile proton concentration and exchange rate utilizing optimal RF power: Radio frequency power (RFP) dependence of chemical exchange saturation transfer (CEST) MRI
    • Sun PZ,. Simultaneous determination of labile proton concentration and exchange rate utilizing optimal RF power: radio frequency power (RFP) dependence of chemical exchange saturation transfer (CEST) MRI. J Magn Reson 2010; 202: 155-161.
    • (2010) J Magn Reson , vol.202 , pp. 155-161
    • Sun, P.Z.1
  • 5
    • 21244455698 scopus 로고    scopus 로고
    • Optimization of the irradiation power in chemical exchange dependent saturation transfer experiments
    • Sun PZ, van Zijl PCM, Zhou J,. Optimization of the irradiation power in chemical exchange dependent saturation transfer experiments. J Magn Reson 2005; 175: 193-200.
    • (2005) J Magn Reson , vol.175 , pp. 193-200
    • Sun, P.Z.1    Van Zijl, P.C.M.2    Zhou, J.3
  • 7
    • 84865484314 scopus 로고    scopus 로고
    • SWIFT-CEST: A new MRI method to overcome T2 shortening caused by PARACEST contrast agents
    • Soesbe TC, Togao O, Takahashi M, Sherry AD,. SWIFT-CEST: a new MRI method to overcome T2 shortening caused by PARACEST contrast agents. Magn Reson Med 2012; 68: 816-821.
    • (2012) Magn Reson Med , vol.68 , pp. 816-821
    • Soesbe, T.C.1    Togao, O.2    Takahashi, M.3    Sherry, A.D.4
  • 8
    • 16444362041 scopus 로고    scopus 로고
    • Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI
    • Woessner DE, Zhang S, Merritt ME, Sherry AD,. Numerical solution of the Bloch equations provides insights into the optimum design of PARACEST agents for MRI. Magn Reson Med 2005; 53: 790-799.
    • (2005) Magn Reson Med , vol.53 , pp. 790-799
    • Woessner, D.E.1    Zhang, S.2    Merritt, M.E.3    Sherry, A.D.4
  • 9
    • 33645772151 scopus 로고    scopus 로고
    • Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): PH calibration for poly-L-lysine and a starburst dendrimer
    • McMahon MT, Gilad AA, Zhou J, Sun PZ, Bulte JW, van Zijl PC,. Quantifying exchange rates in chemical exchange saturation transfer agents using the saturation time and saturation power dependencies of the magnetization transfer effect on the magnetic resonance imaging signal (QUEST and QUESP): pH calibration for poly-L-lysine and a starburst dendrimer. Magn Reson Med 2006; 55: 836-847.
    • (2006) Magn Reson Med , vol.55 , pp. 836-847
    • McMahon, M.T.1    Gilad, A.A.2    Zhou, J.3    Sun, P.Z.4    Bulte, J.W.5    Van Zijl, P.C.6
  • 11
    • 67651089633 scopus 로고    scopus 로고
    • Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies
    • Ali MM, Liu G, Shah T, Flask CA, Pagel MD,. Using two chemical exchange saturation transfer magnetic resonance imaging contrast agents for molecular imaging studies. Acc Chem Res 2009; 42: 915-924.
    • (2009) Acc Chem Res , vol.42 , pp. 915-924
    • Ali, M.M.1    Liu, G.2    Shah, T.3    Flask, C.A.4    Pagel, M.D.5
  • 12
    • 80052965440 scopus 로고    scopus 로고
    • Simulation and optimization of pulsed radio frequency irradiation scheme for chemical exchange saturation transfer (CEST) MRI - Demonstration of pH-weighted pulsed-amide proton CEST MRI in an animal model of acute cerebral ischemia
    • Sun PZ, Wang E, Cheung JS, Zhang X, Benner T, Sorensen AG,. Simulation and optimization of pulsed radio frequency irradiation scheme for chemical exchange saturation transfer (CEST) MRI-demonstration of pH-weighted pulsed-amide proton CEST MRI in an animal model of acute cerebral ischemia. Magn Reson Med 2011; 66: 1042-1048.
    • (2011) Magn Reson Med , vol.66 , pp. 1042-1048
    • Sun, P.Z.1    Wang, E.2    Cheung, J.S.3    Zhang, X.4    Benner, T.5    Sorensen, A.G.6
  • 13
    • 84859103883 scopus 로고    scopus 로고
    • ws) with RF saturation time dependent ratiometric analysis (QUESTRA): Normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI
    • ws) with RF saturation time dependent ratiometric analysis (QUESTRA): normalization of relaxation and RF irradiation spillover effects for improved quantitative chemical exchange saturation transfer (CEST) MRI. Magn Reson Med 2012; 67: 936-942.
    • (2012) Magn Reson Med , vol.67 , pp. 936-942
    • Sun, P.Z.1
  • 14
    • 0034145982 scopus 로고    scopus 로고
    • A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST)
    • Ward KM, Aletras AH, Balaban RS,. A new class of contrast agents for MRI based on proton chemical exchange dependent saturation transfer (CEST). J Magn Reson 2000; 143: 79-87.
    • (2000) J Magn Reson , vol.143 , pp. 79-87
    • Ward, K.M.1    Aletras, A.H.2    Balaban, R.S.3
  • 16
    • 33751330608 scopus 로고
    • Determination of enzyme dissociation constants
    • Lineweaver H, Burk D,. Determination of enzyme dissociation constants. J Am Chem Soc 1934; 56: 658-666.
    • (1934) J Am Chem Soc , vol.56 , pp. 658-666
    • Lineweaver, H.1    Burk, D.2
  • 17
    • 5844225066 scopus 로고
    • On the evaluation of the constants Vm and KM in enzyme reactions
    • Hofstee BH,. On the evaluation of the constants Vm and KM in enzyme reactions. Science 1952; 116: 329-331.
    • (1952) Science , vol.116 , pp. 329-331
    • Hofstee, B.H.1
  • 18
    • 0001465376 scopus 로고
    • Studies on plant amylases: The effect of starch concentration upon the velocity of hydrolysis by the amylase of germinated barley
    • Hanes CS,. Studies on plant amylases: the effect of starch concentration upon the velocity of hydrolysis by the amylase of germinated barley. Biochem J 1932; 26: 1406-1421.
    • (1932) Biochem J , vol.26 , pp. 1406-1421
    • Hanes, C.S.1
  • 19
    • 84863177886 scopus 로고    scopus 로고
    • Improved pH measurements with a single PARACEST MRI contrast agent
    • Sheth VR, Liu G, Li Y, Pagel MD,. Improved pH measurements with a single PARACEST MRI contrast agent. Contrast Media Mol Imaging 2012; 7: 26-34.
    • (2012) Contrast Media Mol Imaging , vol.7 , pp. 26-34
    • Sheth, V.R.1    Liu, G.2    Li, Y.3    Pagel, M.D.4
  • 20
    • 32544454854 scopus 로고
    • Calibration of the methanol and glycol nuclear magnetic resonance thermometers with a static thermistor probe
    • Van Geet AL,. Calibration of the methanol and glycol nuclear magnetic resonance thermometers with a static thermistor probe. Anal Chem 1968; 40: 2227-2229.
    • (1968) Anal Chem , vol.40 , pp. 2227-2229
    • Van Geet, A.L.1
  • 21
    • 78649916470 scopus 로고    scopus 로고
    • Numerical solutions to the time-dependent Bloch equations revisited
    • Murase K, Tanki M,. Numerical solutions to the time-dependent Bloch equations revisited. Magn Reson Imaging 2011; 29: 126-131.
    • (2011) Magn Reson Imaging , vol.29 , pp. 126-131
    • Murase, K.1    Tanki, M.2
  • 22
    • 84865142753 scopus 로고    scopus 로고
    • Evaluating the use of a continuous approximation for model-based quantification of pulsed chemical exchange saturation transfer (CEST)
    • Tee YK, Khrapitchev AA, Sibson NR, Payne SJ, Chappell MA,. Evaluating the use of a continuous approximation for model-based quantification of pulsed chemical exchange saturation transfer (CEST). J Magn Reson 2012; 222: 88-95.
    • (2012) J Magn Reson , vol.222 , pp. 88-95
    • Tee, Y.K.1    Khrapitchev, A.A.2    Sibson, N.R.3    Payne, S.J.4    Chappell, M.A.5
  • 23
    • 84859109553 scopus 로고    scopus 로고
    • Understanding quantitative pulsed CEST in the presence of MT
    • Desmond KL, Stanisz GJ,. Understanding quantitative pulsed CEST in the presence of MT. Magn Reson Med 2012; 67: 979-990.
    • (2012) Magn Reson Med , vol.67 , pp. 979-990
    • Desmond, K.L.1    Stanisz, G.J.2
  • 24
    • 36849059642 scopus 로고    scopus 로고
    • Correction for artifacts induced by B0 and B1 field inhomogeneities in pH-sensitive chemical exchange saturation transfer (CEST) imaging
    • Sun PZ, Farrar CT, Sorensen AG,. Correction for artifacts induced by B0 and B1 field inhomogeneities in pH-sensitive chemical exchange saturation transfer (CEST) imaging. Magn Reson Med 2007; 58: 1207-1215.
    • (2007) Magn Reson Med , vol.58 , pp. 1207-1215
    • Sun, P.Z.1    Farrar, C.T.2    Sorensen, A.G.3
  • 25
    • 80051938706 scopus 로고    scopus 로고
    • A self-calibrating PARACEST MRI contrast agent that detects esterase enzyme activity
    • Li Y, Sheth VR, Liu G, Pagel MD,. A self-calibrating PARACEST MRI contrast agent that detects esterase enzyme activity. Contrast Media Mol Imaging 2011; 6: 219-228.
    • (2011) Contrast Media Mol Imaging , vol.6 , pp. 219-228
    • Li, Y.1    Sheth, V.R.2    Liu, G.3    Pagel, M.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.