-
1
-
-
84876810849
-
-
World Health Organization (WHO). Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. WHO Technical Report Series 843. WHO: Geneva;
-
World Health Organization (WHO). Assessment of fracture risk and its application to screening for postmenopausal osteoporosis. WHO Technical Report Series 843. WHO: Geneva; 1994.
-
(1994)
-
-
-
2
-
-
0032869574
-
Interim report and recommendations of the World Health Organization task-force for osteoporosis
-
Genant HK, Cooper C, Poor G, Reid I, Ehrlich G, Kanis J, Nordin BEC, Barrett-Connor E, Black D, Bonjour J-P, Dawson-Hughes B, Delmas PD, Dequeker J, Eis SR, Gennari LR, Martin TJ, Masri B, Mautalen CA, Meunier PJ, Miller PD, Mithal A, Morii H, Papapoulos S, Woolf A, Yu W, Khaltaev N. Interim report and recommendations of the World Health Organization task-force for osteoporosis. Osteoporos. Int. 1999; 10: 259-264.
-
(1999)
Osteoporos. Int.
, vol.10
, pp. 259-264
-
-
Genant, H.K.1
Cooper, C.2
Poor, G.3
Reid, I.4
Ehrlich, G.5
Kanis, J.6
Nordin, B.E.C.7
Barrett-Connor, E.8
Black, D.9
Bonjour, J.-P.10
Dawson-Hughes, B.11
Delmas, P.D.12
Dequeker, J.13
Eis, S.R.14
Gennari, L.R.15
Martin, T.J.16
Masri, B.17
Mautalen, C.A.18
Meunier, P.J.19
Miller, P.D.20
Mithal, A.21
Morii, H.22
Papapoulos, S.23
Woolf, A.24
Yu, W.25
Khaltaev, N.26
more..
-
3
-
-
0033969402
-
Bone matters: are density increases necessary to reduce fracture risk?
-
Faulkner KG. Bone matters: are density increases necessary to reduce fracture risk? J. Bone Miner. Res. 2000; 15: 183-187.
-
(2000)
J. Bone Miner. Res.
, vol.15
, pp. 183-187
-
-
Faulkner, K.G.1
-
4
-
-
0942268144
-
Fracture incidence and association with bone mineral density in elderly men and women: the Rotterdam study
-
Schuit SCE, Klift M, Weel AEAM, de Laet CEDH, Burger H, Seeman E, Hofman A, Uitterlinden AG, van Leeuwen JPTM, Pols HAP. Fracture incidence and association with bone mineral density in elderly men and women: the Rotterdam study. Bone 2004; 34: 195-202.
-
(2004)
Bone
, vol.34
, pp. 195-202
-
-
Schuit, S.C.E.1
Klift, M.2
Weel, A.E.A.M.3
de Laet, C.E.D.H.4
Burger, H.5
Seeman, E.6
Hofman, A.7
Uitterlinden, A.G.8
van Leeuwen, J.P.T.M.9
Pols, H.A.P.10
-
5
-
-
0035700603
-
Ten year probabilities of osteoporotic fractures according to BMD and diagnostic thresholds
-
Kanis JA, Johnell O, Oden A, Dawson A, De Laet C, Jonsson B. Ten year probabilities of osteoporotic fractures according to BMD and diagnostic thresholds. Osteoporos. Int. 2001; 12: 989-995.
-
(2001)
Osteoporos. Int.
, vol.12
, pp. 989-995
-
-
Kanis, J.A.1
Johnell, O.2
Oden, A.3
Dawson, A.4
De Laet, C.5
Jonsson, B.6
-
6
-
-
0036119735
-
Improvement in spine bone density and reduction in risk of vertebral fractures during treatment with antiresorptive drugs
-
Cummings SR, Karpf DB, Harris F, Genant HK, Ensrud K, LaCroix AZ, Black DM. Improvement in spine bone density and reduction in risk of vertebral fractures during treatment with antiresorptive drugs. Am. J. Med. 2002; 112: 281-289.
-
(2002)
Am. J. Med.
, vol.112
, pp. 281-289
-
-
Cummings, S.R.1
Karpf, D.B.2
Harris, F.3
Genant, H.K.4
Ensrud, K.5
LaCroix, A.Z.6
Black, D.M.7
-
7
-
-
0030786934
-
Bone density and the risk of hip fracture in men and women: cross sectional analysis
-
De Lact C, van Hout B, Burger H, Hofman A, Pols H. Bone density and the risk of hip fracture in men and women: cross sectional analysis. Br. Med. J. 1997; 315: 221-225.
-
(1997)
Br. Med. J.
, vol.315
, pp. 221-225
-
-
De Lact, C.1
van Hout, B.2
Burger, H.3
Hofman, A.4
Pols, H.5
-
8
-
-
84864304634
-
Microarchitecture, the key to bone quality
-
Brandi ML. Microarchitecture, the key to bone quality. Rheumatology 2009; 48: 3-8.
-
(2009)
Rheumatology
, vol.48
, pp. 3-8
-
-
Brandi, M.L.1
-
9
-
-
0028963682
-
Risk factors for hip fracture in white women. Study of osteoporotic fractures research group
-
Cummings SR, Nevitt MC, Browner WS, Stone K, Fox KM, Ensrud KE, Cauley J, Black D, Vogt TM. Risk factors for hip fracture in white women. Study of osteoporotic fractures research group. N. Engl. J. Med. 1995; 332: 767-773.
-
(1995)
N. Engl. J. Med.
, vol.332
, pp. 767-773
-
-
Cummings, S.R.1
Nevitt, M.C.2
Browner, W.S.3
Stone, K.4
Fox, K.M.5
Ensrud, K.E.6
Cauley, J.7
Black, D.8
Vogt, T.M.9
-
10
-
-
0029885623
-
Clinical utility of bone mass measurements in adults: consensus of an international panel
-
Miller PD, Bonnick SL, Rosen CJ, Altman RD, Avioli LV, Dequeker J, Felsenberg D, Genant HK, Gennari C, Harper KD, Hodsman AB, Kleerekoper M, Mautalen CA, McClung MR, Meunier PJ, Nelson DA, Peel NF, Raisz LG, Recker RR, Utian WH, Wasnich RD, Watts NB. Clinical utility of bone mass measurements in adults: consensus of an international panel. Semin. Arthritis Rheum. 1996; 25: 361-372.
-
(1996)
Semin. Arthritis Rheum.
, vol.25
, pp. 361-372
-
-
Miller, P.D.1
Bonnick, S.L.2
Rosen, C.J.3
Altman, R.D.4
Avioli, L.V.5
Dequeker, J.6
Felsenberg, D.7
Genant, H.K.8
Gennari, C.9
Harper, K.D.10
Hodsman, A.B.11
Kleerekoper, M.12
Mautalen, C.A.13
McClung, M.R.14
Meunier, P.J.15
Nelson, D.A.16
Peel, N.F.17
Raisz, L.G.18
Recker, R.R.19
Utian, W.H.20
Wasnich, R.D.21
Watts, N.B.22
more..
-
11
-
-
0019151527
-
Age changes in bone mineralization: cortical thickness and Haversian canal area
-
Thompson DD. Age changes in bone mineralization: cortical thickness and Haversian canal area. Calcif. Tissue Int. 1980; 31: 5-11.
-
(1980)
Calcif. Tissue Int.
, vol.31
, pp. 5-11
-
-
Thompson, D.D.1
-
12
-
-
33751383444
-
Quantitative MRI for the assessment of bone structure and function
-
Wehrli FW, Song HK, Saha PK, Wright AC. Quantitative MRI for the assessment of bone structure and function. NMR Biomed. 2006; 19: 731-764.
-
(2006)
NMR Biomed.
, vol.19
, pp. 731-764
-
-
Wehrli, F.W.1
Song, H.K.2
Saha, P.K.3
Wright, A.C.4
-
13
-
-
0025730177
-
Trabecular structure: preliminary application of MR interferometry
-
Wehrli FW, Ford JC, Attie M, Kressel HY, Kaplan FS. Trabecular structure: preliminary application of MR interferometry. Radiology 1991; 179: 615-621.
-
(1991)
Radiology
, vol.179
, pp. 615-621
-
-
Wehrli, F.W.1
Ford, J.C.2
Attie, M.3
Kressel, H.Y.4
Kaplan, F.S.5
-
14
-
-
0032790990
-
Fracture analysis of radiographs: assessment of trabecular bone structure and prediction of elastic modulus and strength
-
Majumdar S, Lin J, Link T, Millard J, Augat P, Ouyang X, Gould NR, Genant H. Fracture analysis of radiographs: assessment of trabecular bone structure and prediction of elastic modulus and strength. Med. Phys. 1999; 26: 1330-1340.
-
(1999)
Med. Phys.
, vol.26
, pp. 1330-1340
-
-
Majumdar, S.1
Lin, J.2
Link, T.3
Millard, J.4
Augat, P.5
Ouyang, X.6
Gould, N.R.7
Genant, H.8
-
15
-
-
0030660690
-
Unraveling the role of structure and density in determining vertebral bone strength
-
Veenland J, Link T, Konermann W, Meier N, Grashuis J, Gelsema E. Unraveling the role of structure and density in determining vertebral bone strength. Calcif. Tissue Int. 1997; 61: 474-479.
-
(1997)
Calcif. Tissue Int.
, vol.61
, pp. 474-479
-
-
Veenland, J.1
Link, T.2
Konermann, W.3
Meier, N.4
Grashuis, J.5
Gelsema, E.6
-
17
-
-
76549120263
-
High-resolution peripheral QCT imaging of bone micro-structure in adolescents
-
Burrows M, Liu D, McKay H. High-resolution peripheral QCT imaging of bone micro-structure in adolescents. Osteoporos. Int. 2009; 21: 515-520.
-
(2009)
Osteoporos. Int.
, vol.21
, pp. 515-520
-
-
Burrows, M.1
Liu, D.2
McKay, H.3
-
18
-
-
3042796042
-
Quantitative high-resolution magnetic resonance imaging reveals structural implications of renal osteodystrophy on trabecular and cortical bone
-
Wehrli FW, Leonard MB, Saha PK, Song H, Gomberg BR. Quantitative high-resolution magnetic resonance imaging reveals structural implications of renal osteodystrophy on trabecular and cortical bone. J. Magn. Reson. Imaging 2004; 20: 83-89.
-
(2004)
J. Magn. Reson. Imaging
, vol.20
, pp. 83-89
-
-
Wehrli, F.W.1
Leonard, M.B.2
Saha, P.K.3
Song, H.4
Gomberg, B.R.5
-
19
-
-
79960570069
-
MRI of trabecular bone using a decay due to diffusion in the internal field contrast imaging sequence
-
Mintzopoulos D, Ackerman JL, Song YQ. MRI of trabecular bone using a decay due to diffusion in the internal field contrast imaging sequence. J. Magn. Reson. Imaging 2011; 34: 361-371.
-
(2011)
J. Magn. Reson. Imaging
, vol.34
, pp. 361-371
-
-
Mintzopoulos, D.1
Ackerman, J.L.2
Song, Y.Q.3
-
20
-
-
0027170485
-
Age-related changes in the tensile properties of cortical bone: the relative importance of changes in porosity, mineralization and microstructure
-
McCalden RW, McGeough JA, Barker MB, Court-Brown CM. Age-related changes in the tensile properties of cortical bone: the relative importance of changes in porosity, mineralization and microstructure. J. Bone Joint Surg. Am. 1993; 75: 1193-1205.
-
(1993)
J. Bone Joint Surg. Am.
, vol.75
, pp. 1193-1205
-
-
McCalden, R.W.1
McGeough, J.A.2
Barker, M.B.3
Court-Brown, C.M.4
-
21
-
-
20544456605
-
Effects of damage morphology on cortical bone fragility
-
Diab T, Vashishth D. Effects of damage morphology on cortical bone fragility. Bone 2005; 37: 96-102.
-
(2005)
Bone
, vol.37
, pp. 96-102
-
-
Diab, T.1
Vashishth, D.2
-
23
-
-
0034967812
-
Distribution of intracortical porosity in human midfemoral cortex by age and gender
-
Bousson V, Meunier A, Bergot C, Vicaut E, Rocha MA, Morais MH, Laval-Jeantet AM, Laredo JD. Distribution of intracortical porosity in human midfemoral cortex by age and gender. J. Bone Miner. Res. 2001; 16: 1308-1317.
-
(2001)
J. Bone Miner. Res.
, vol.16
, pp. 1308-1317
-
-
Bousson, V.1
Meunier, A.2
Bergot, C.3
Vicaut, E.4
Rocha, M.A.5
Morais, M.H.6
Laval-Jeantet, A.M.7
Laredo, J.D.8
-
24
-
-
0023901292
-
Stiffness of compact bone: effects of porosity and density
-
Schaffler MB, Burr DB. Stiffness of compact bone: effects of porosity and density. J. Biomech. 1988; 21: 13-16.
-
(1988)
J. Biomech.
, vol.21
, pp. 13-16
-
-
Schaffler, M.B.1
Burr, D.B.2
-
25
-
-
0023873049
-
The effect of porosity and mineral content on Young's modulus of elasticity of compact bone
-
Currey J. The effect of porosity and mineral content on Young's modulus of elasticity of compact bone. J. Biomech. 1988; 21: 131-139.
-
(1988)
J. Biomech.
, vol.21
, pp. 131-139
-
-
Currey, J.1
-
26
-
-
0031983224
-
Influence of bone composition and apparent density on fracture toughness of the human femur and tibia
-
Yeni YN, Brown CU, Norman TL. Influence of bone composition and apparent density on fracture toughness of the human femur and tibia. Bone 1998; 22: 79-84.
-
(1998)
Bone
, vol.22
, pp. 79-84
-
-
Yeni, Y.N.1
Brown, C.U.2
Norman, T.L.3
-
27
-
-
77953520506
-
Age and gender related differences in the geometric properties and biomechanical significance of intra-cortical porosity in the distal radius and tibia
-
Burghardt AJ, Kazakia GJ, Ramachandran S, Link TM, Majumdar S. Age and gender related differences in the geometric properties and biomechanical significance of intra-cortical porosity in the distal radius and tibia. J. Bone Miner. Res. 2010; 25: 983-993.
-
(2010)
J. Bone Miner. Res.
, vol.25
, pp. 983-993
-
-
Burghardt, A.J.1
Kazakia, G.J.2
Ramachandran, S.3
Link, T.M.4
Majumdar, S.5
-
28
-
-
0024379891
-
The relative effects of collagen fiber orientation, porosity, density, and mineralization on bone strength
-
Martin RB, Ishida J. The relative effects of collagen fiber orientation, porosity, density, and mineralization on bone strength. J. Biomech. 1989; 22: 419-426.
-
(1989)
J. Biomech.
, vol.22
, pp. 419-426
-
-
Martin, R.B.1
Ishida, J.2
-
30
-
-
0033135755
-
The role of collagen in the declining mechanical properties of aging human cortical bone
-
Zioupos P, Currey JD, Hamer AJ. The role of collagen in the declining mechanical properties of aging human cortical bone. J. Biomed. Mater. Res. 1999; 45: 108-116.
-
(1999)
J. Biomed. Mater. Res.
, vol.45
, pp. 108-116
-
-
Zioupos, P.1
Currey, J.D.2
Hamer, A.J.3
-
31
-
-
0019769139
-
A mixed pacing model for bone collagen
-
Lees S. A mixed pacing model for bone collagen. Calcif. Tissue Int. 1981; 33: 591-602.
-
(1981)
Calcif. Tissue Int.
, vol.33
, pp. 591-602
-
-
Lees, S.1
-
32
-
-
0036313364
-
Age-related changes in the collagen network and toughness of bone
-
Wang X, Shen X, Li X, Mauli Agrawal C. Age-related changes in the collagen network and toughness of bone. Bone 2002; 31: 1-7.
-
(2002)
Bone
, vol.31
, pp. 1-7
-
-
Wang, X.1
Shen, X.2
Li, X.3
Mauli Agrawal, C.4
-
37
-
-
0013861099
-
Bone density and composition: age-related and pathological changes in water and mineral content
-
Mueller KH, Trias A, Ray RD. Bone density and composition: age-related and pathological changes in water and mineral content. J. Bone Joint Surg. Am. 1966; 48: 140-148.
-
(1966)
J. Bone Joint Surg. Am.
, vol.48
, pp. 140-148
-
-
Mueller, K.H.1
Trias, A.2
Ray, R.D.3
-
38
-
-
0020032931
-
Fluid spaces in canine bone and marrow
-
Morris MA, Lopez-Curto JA, Hughes SPF, An K, Bassingthwaighte JB, Kelly PJ. Fluid spaces in canine bone and marrow. Microvasc. Res. 1982; 32: 188-200.
-
(1982)
Microvasc. Res.
, vol.32
, pp. 188-200
-
-
Morris, M.A.1
Lopez-Curto, J.A.2
Hughes, S.P.F.3
An, K.4
Bassingthwaighte, J.B.5
Kelly, P.J.6
-
39
-
-
0032983135
-
Bone poroelasticity
-
Cowin SC. Bone poroelasticity. J. Biomech. 1999; 32: 217-238.
-
(1999)
J. Biomech.
, vol.32
, pp. 217-238
-
-
Cowin, S.C.1
-
40
-
-
32644452256
-
The influence of water removal on the strength and toughness of cortical bone
-
Nyman JS, Roy A, Shen X, Rae LA, Tyler JH, Wang X. The influence of water removal on the strength and toughness of cortical bone. J. Biochem. 2006; 39(5): 931-938.
-
(2006)
J. Biochem.
, vol.39
, Issue.5
, pp. 931-938
-
-
Nyman, J.S.1
Roy, A.2
Shen, X.3
Rae, L.A.4
Tyler, J.H.5
Wang, X.6
-
42
-
-
0026648265
-
Evaluation of the skeletal kinetics of fluorine-18-fluoride ion with PET
-
Hawkins RA, Choi Y, Huang SC, Hoh CK, Dahlbom M, Schiepers C, Satyamurthy N, Barrio JR, Phelps ME. Evaluation of the skeletal kinetics of fluorine-18-fluoride ion with PET. J. Nucl. Med. 1992; 33: 633-642.
-
(1992)
J. Nucl. Med.
, vol.33
, pp. 633-642
-
-
Hawkins, R.A.1
Choi, Y.2
Huang, S.C.3
Hoh, C.K.4
Dahlbom, M.5
Schiepers, C.6
Satyamurthy, N.7
Barrio, J.R.8
Phelps, M.E.9
-
43
-
-
0023890808
-
Skeletal blood flow, iliac histomorphometry, and strontium kinetics in osteoporosis: a relationship between blood flow and corrected apposition rate
-
Reeve J, Arlot M, Wootton R, Edouard C, Tellez M, Hesp R, Green JR, Meunier PJ. Skeletal blood flow, iliac histomorphometry, and strontium kinetics in osteoporosis: a relationship between blood flow and corrected apposition rate. J. Clin. Endocrinol. Metab. 1988; 66: 1124-1131.
-
(1988)
J. Clin. Endocrinol. Metab.
, vol.66
, pp. 1124-1131
-
-
Reeve, J.1
Arlot, M.2
Wootton, R.3
Edouard, C.4
Tellez, M.5
Hesp, R.6
Green, J.R.7
Meunier, P.J.8
-
44
-
-
33750728630
-
The physiology of bone blood flow: a review
-
McCarthy I. The physiology of bone blood flow: a review. J. Bone Joint Surg. 2006; 88: 4-9.
-
(2006)
J. Bone Joint Surg.
, vol.88
, pp. 4-9
-
-
McCarthy, I.1
-
45
-
-
84876791873
-
-
Pharmacokinetic modeling study on bone perfusion of osteoporosis. Proceedings of the 18th Annual Meeting ISMRM, Stockholm, Sweden
-
Ma HT, Griffith JF, Yeung DK, Leung PC. Pharmacokinetic modeling study on bone perfusion of osteoporosis. Proceedings of the 18th Annual Meeting ISMRM, Stockholm, Sweden, 2010; 1968.
-
(2010)
, pp. 1968
-
-
Ma, H.T.1
Griffith, J.F.2
Yeung, D.K.3
Leung, P.C.4
-
46
-
-
68849131946
-
Reduced bone perfusion in proximal femur of subjects with decreased bone mineral density preferentially affects the femoral neck
-
Wang YX, Griffith JF, Kwok AWL, Leung JCS, Yeung DKW, Ahuja AT, Leung PC. Reduced bone perfusion in proximal femur of subjects with decreased bone mineral density preferentially affects the femoral neck. Bone 2009; 45: 711-715.
-
(2009)
Bone
, vol.45
, pp. 711-715
-
-
Wang, Y.X.1
Griffith, J.F.2
Kwok, A.W.L.3
Leung, J.C.S.4
Yeung, D.K.W.5
Ahuja, A.T.6
Leung, P.C.7
-
48
-
-
0031024406
-
Bone mineral density and blood flow to the lower extremities: the study of osteoporotic fractures
-
Vogt MT, Cauley JA, Kuller LH, Nevitt MC. Bone mineral density and blood flow to the lower extremities: the study of osteoporotic fractures. J. Bone Miner. Res. 1997; 12: 283-289.
-
(1997)
J. Bone Miner. Res.
, vol.12
, pp. 283-289
-
-
Vogt, M.T.1
Cauley, J.A.2
Kuller, L.H.3
Nevitt, M.C.4
-
49
-
-
0025876984
-
Lung parenchyma: projection reconstruction MR imaging
-
Bergin CJ, Pauly JM, Macovski A. Lung parenchyma: projection reconstruction MR imaging. Radiology 1991; 179: 777-781.
-
(1991)
Radiology
, vol.179
, pp. 777-781
-
-
Bergin, C.J.1
Pauly, J.M.2
Macovski, A.3
-
51
-
-
0031593443
-
Design of practical T2-selective RF excitation (TELEX) pulses
-
Sussman MS, Pauly JM, Wright GA. Design of practical T2-selective RF excitation (TELEX) pulses. Magn. Reson. Med. 1998; 40: 890-899.
-
(1998)
Magn. Reson. Med.
, vol.40
, pp. 890-899
-
-
Sussman, M.S.1
Pauly, J.M.2
Wright, G.A.3
-
53
-
-
22744434905
-
Magnetic resonance imaging of cortical bone with ultrashort TE (UTE) pulse sequences
-
Reichert ILH, Robson MD, Gatehouse PD, He T, Chappell KE, Holmes J, Girgis S, Bydder GM. Magnetic resonance imaging of cortical bone with ultrashort TE (UTE) pulse sequences. Magn. Reson. Imaging, 2005; 23: 611-618.
-
(2005)
Magn. Reson. Imaging
, vol.23
, pp. 611-618
-
-
Reichert, I.L.H.1
Robson, M.D.2
Gatehouse, P.D.3
He, T.4
Chappell, K.E.5
Holmes, J.6
Girgis, S.7
Bydder, G.M.8
-
54
-
-
35948947385
-
Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging
-
Larson PE, Conolly SM, Pauly JM, Nishimura DG. Using adiabatic inversion pulses for long-T2 suppression in ultrashort echo time (UTE) imaging. Magn. Reson. Med. 2007; 58: 952-961.
-
(2007)
Magn. Reson. Med.
, vol.58
, pp. 952-961
-
-
Larson, P.E.1
Conolly, S.M.2
Pauly, J.M.3
Nishimura, D.G.4
-
55
-
-
35948963686
-
Ultrashort TE spectroscopic imaging (UTESI) of cortical bone
-
Du J, Hamilton G, Takahashi A, Bydder M, Chung CB. Ultrashort TE spectroscopic imaging (UTESI) of cortical bone. Magn. Reson. Med. 2007; 58: 1001-1009.
-
(2007)
Magn. Reson. Med.
, vol.58
, pp. 1001-1009
-
-
Du, J.1
Hamilton, G.2
Takahashi, A.3
Bydder, M.4
Chung, C.B.5
-
56
-
-
40049083116
-
Two dimensional ultrashort echo time imaging using a spiral trajectory
-
Du J, Takahashi A, Bydder M, Chung CB. Two dimensional ultrashort echo time imaging using a spiral trajectory. Magn. Reson. Imaging 2008; 26: 304-312.
-
(2008)
Magn. Reson. Imaging
, vol.26
, pp. 304-312
-
-
Du, J.1
Takahashi, A.2
Bydder, M.3
Chung, C.B.4
-
57
-
-
67749116329
-
Ultrashort TE imaging with off-resonance saturation contrast (UTE-OSC)
-
Du J, Takahashi A, Bydder M, Chung CB, Bydder GM. Ultrashort TE imaging with off-resonance saturation contrast (UTE-OSC). Magn. Reson. Med. 2009; 62: 527-531.
-
(2009)
Magn. Reson. Med.
, vol.62
, pp. 527-531
-
-
Du, J.1
Takahashi, A.2
Bydder, M.3
Chung, C.B.4
Bydder, G.M.5
-
58
-
-
75749154996
-
Dual inversion recovery, ultrashort echo time (DIR UTE) imaging: creating high contrast for short-T2 species
-
Du J, Takahashi A, Bae WC, Chung CB, Bydder GM. Dual inversion recovery, ultrashort echo time (DIR UTE) imaging: creating high contrast for short-T2 species. Magn. Reson. Med. 2010; 63: 447-455.
-
(2010)
Magn. Reson. Med.
, vol.63
, pp. 447-455
-
-
Du, J.1
Takahashi, A.2
Bae, W.C.3
Chung, C.B.4
Bydder, G.M.5
-
59
-
-
78649449575
-
Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone
-
Du J, Carl M, Bydder M, Takahashi A, Chung CB, Bydder GM. Qualitative and quantitative ultrashort echo time (UTE) imaging of cortical bone. J. Magn. Reson. 2010; 207: 304-311.
-
(2010)
J. Magn. Reson.
, vol.207
, pp. 304-311
-
-
Du, J.1
Carl, M.2
Bydder, M.3
Takahashi, A.4
Chung, C.B.5
Bydder, G.M.6
-
60
-
-
38949211045
-
In vivo MRI of submilli second T2 species with two-dimensional and three-dimensional radial sequences and applications to the measurement of cortical bone water
-
Techawiboonwong A, Song HK, Wehrli FW. In vivo MRI of submilli second T2 species with two-dimensional and three-dimensional radial sequences and applications to the measurement of cortical bone water. NMR Biomed. 2008; 21: 59-70.
-
(2008)
NMR Biomed.
, vol.21
, pp. 59-70
-
-
Techawiboonwong, A.1
Song, H.K.2
Wehrli, F.W.3
-
61
-
-
51549099461
-
Cortical bone water: in vivo quantification with ultrashort echo-time MR imaging
-
Techawiboonwong A, Song HK, Leonard MB, Wehrli FW. Cortical bone water: in vivo quantification with ultrashort echo-time MR imaging. Radiology 2008; 248: 824-833.
-
(2008)
Radiology
, vol.248
, pp. 824-833
-
-
Techawiboonwong, A.1
Song, H.K.2
Leonard, M.B.3
Wehrli, F.W.4
-
62
-
-
33646447508
-
Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
-
Rahmer J, Bornert P, Groen J, Bos C. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn. Reson. Med. 2006; 55: 1075-1082.
-
(2006)
Magn. Reson. Med.
, vol.55
, pp. 1075-1082
-
-
Rahmer, J.1
Bornert, P.2
Groen, J.3
Bos, C.4
-
63
-
-
79954582760
-
Short T2 contrast with three-dimensional ultrashort echo time imaging
-
Du J, Bydder M, Takahashi AM, Carl M, Chung CB, Bydder GM. Short T2 contrast with three-dimensional ultrashort echo time imaging. Magn. Reson. Imaging 2011; 29: 470-482.
-
(2011)
Magn. Reson. Imaging
, vol.29
, pp. 470-482
-
-
Du, J.1
Bydder, M.2
Takahashi, A.M.3
Carl, M.4
Chung, C.B.5
Bydder, G.M.6
-
64
-
-
0037925188
-
Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI
-
Wu Y, Ackerman JL, Chesler DA, Graham L, Wang Y, Glimcher MJ. Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI. Magn. Reson. Med. 2003; 50: 59-68.
-
(2003)
Magn. Reson. Med.
, vol.50
, pp. 59-68
-
-
Wu, Y.1
Ackerman, J.L.2
Chesler, D.A.3
Graham, L.4
Wang, Y.5
Glimcher, M.J.6
-
65
-
-
57149109582
-
Quantitative bone matrix density measurement by water- and fat-suppressed proton projection MRI (WASPI) with polymer calibration phantoms
-
Cao H, Ackerman JL, Hrovat MI, Graham L, Glimcher MJ, Wu Y. Quantitative bone matrix density measurement by water- and fat-suppressed proton projection MRI (WASPI) with polymer calibration phantoms. Magn. Reson. Med. 2008; 60: 1433-1443.
-
(2008)
Magn. Reson. Med.
, vol.60
, pp. 1433-1443
-
-
Cao, H.1
Ackerman, J.L.2
Hrovat, M.I.3
Graham, L.4
Glimcher, M.J.5
Wu, Y.6
-
66
-
-
0038287424
-
Detection of hydroxyl ions in bone mineral by solid-state NMR spectroscopy
-
Cho G, Wu Y, Ackerman JL. Detection of hydroxyl ions in bone mineral by solid-state NMR spectroscopy. Science 2003; 300: 1123-1127.
-
(2003)
Science
, vol.300
, pp. 1123-1127
-
-
Cho, G.1
Wu, Y.2
Ackerman, J.L.3
-
67
-
-
77950886601
-
Bone matrix imaged in vivo by water- and fat-suppressed proton projection MRI (WASPI) of animal and human subjects
-
Wu Y, Hrovat MI, Ackerman JL, Reese TG, Cao H, Ecklund K, Glimcher MJ. Bone matrix imaged in vivo by water- and fat-suppressed proton projection MRI (WASPI) of animal and human subjects. J. Magn. Reson. Imaging 2010; 31: 954-963.
-
(2010)
J. Magn. Reson. Imaging
, vol.31
, pp. 954-963
-
-
Wu, Y.1
Hrovat, M.I.2
Ackerman, J.L.3
Reese, T.G.4
Cao, H.5
Ecklund, K.6
Glimcher, M.J.7
-
68
-
-
84876786070
-
-
Role of MRI and MRS for the study of bone and bone marrow in animal models of disease. Sunrise Lecture Notes of the 19th Annual Meeting ISMRM, Montreal, Canada
-
Wehrli F. Role of MRI and MRS for the study of bone and bone marrow in animal models of disease. Sunrise Lecture Notes of the 19th Annual Meeting ISMRM, Montreal, Canada, 2011.
-
(2011)
-
-
Wehrli, F.1
-
69
-
-
66149150655
-
Magnetization transfer contrast imaging in bovine and human cortical bone applying an ultrashort echo time sequence at 3 Tesla
-
Springer F, Martirosian P, Machann J, Schwenzer NF, Claussen CD, Schick F. Magnetization transfer contrast imaging in bovine and human cortical bone applying an ultrashort echo time sequence at 3 Tesla. Magn. Reson. Med. 2009; 61: 1040-1048.
-
(2009)
Magn. Reson. Med.
, vol.61
, pp. 1040-1048
-
-
Springer, F.1
Martirosian, P.2
Machann, J.3
Schwenzer, N.F.4
Claussen, C.D.5
Schick, F.6
-
70
-
-
58149288349
-
Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner
-
Springer F, Martirosian P, Schwenzer NF, Szimtenings M, Kreisler P, Claussen CD, Schick F. Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner. Invest. Radiol. 2008; 43: 802-808.
-
(2008)
Invest. Radiol.
, vol.43
, pp. 802-808
-
-
Springer, F.1
Martirosian, P.2
Schwenzer, N.F.3
Szimtenings, M.4
Kreisler, P.5
Claussen, C.D.6
Schick, F.7
-
71
-
-
80052426374
-
Rapid assessment of longitudinal relaxation time in materials and tissue with extremely fast signal decay using UTE sequences and the variable flip angle method
-
Springer F, Steidle G, Martirosian P, Syha R, Claussen CD, Schick F. Rapid assessment of longitudinal relaxation time in materials and tissue with extremely fast signal decay using UTE sequences and the variable flip angle method. Invest. Radiol. 2011; 46: 610-617.
-
(2011)
Invest. Radiol.
, vol.46
, pp. 610-617
-
-
Springer, F.1
Steidle, G.2
Martirosian, P.3
Syha, R.4
Claussen, C.D.5
Schick, F.6
-
72
-
-
84876815251
-
-
Ultrashort TE (UTE) imaging of the cortical bone at 3T. Proceedings of the 15th Annual Meeting ISMRM, Berlin, Germany
-
Du J, Takahashi AM, Shimakawa A, Bydder M, Sinha S, Bydder GM. Ultrashort TE (UTE) imaging of the cortical bone at 3T. Proceedings of the 15th Annual Meeting ISMRM, Berlin, Germany, 2007; 381.
-
(2007)
, pp. 381
-
-
Du, J.1
Takahashi, A.M.2
Shimakawa, A.3
Bydder, M.4
Sinha, S.5
Bydder, G.M.6
-
73
-
-
77349095247
-
Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence
-
Du J, Chiang AJ, Chung CB, Statum S, Znamirowski R, Takahashi A, Bydder GM. Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence. Magn. Reson. Imaging 2010; 28: 178-184.
-
(2010)
Magn. Reson. Imaging
, vol.28
, pp. 178-184
-
-
Du, J.1
Chiang, A.J.2
Chung, C.B.3
Statum, S.4
Znamirowski, R.5
Takahashi, A.6
Bydder, G.M.7
-
74
-
-
84865526371
-
Comparison of optimized soft-tissue suppression schemes for ultrashort echo time (UTE) MRI
-
Epub ahead of print).
-
Li C, Magland J, Rad H, Song HK, Wehrli F. Comparison of optimized soft-tissue suppression schemes for ultrashort echo time (UTE) MRI. Magn. Reson. Med. 2011; 68: 680-689 (Epub ahead of print).
-
(2011)
Magn. Reson. Med.
, vol.68
, pp. 680-689
-
-
Li, C.1
Magland, J.2
Rad, H.3
Song, H.K.4
Wehrli, F.5
-
75
-
-
84856212651
-
Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA)
-
Epub ahead of print).
-
Grodzki DM, Jakob PM, Heismann B. Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA). Magn. Reson. Med. 2011; 67: 510-518 (Epub ahead of print).
-
(2011)
Magn. Reson. Med.
, vol.67
, pp. 510-518
-
-
Grodzki, D.M.1
Jakob, P.M.2
Heismann, B.3
-
76
-
-
79960600053
-
MRI with zero echo time: hard versus sweep pulse excitation
-
Weiger M, Pruessmann KP, Hennel F. MRI with zero echo time: hard versus sweep pulse excitation. Magn. Reson. Med. 2011; 66: 379-389.
-
(2011)
Magn. Reson. Med.
, vol.66
, pp. 379-389
-
-
Weiger, M.1
Pruessmann, K.P.2
Hennel, F.3
-
78
-
-
79952800913
-
Direct imaging and quantification of carotid plaque calcification
-
Du J, Corbeil J, Znamirowski R, Angle N, Peterson M, Bydder GM, Kahn AM. Direct imaging and quantification of carotid plaque calcification. Magn. Reson. Med. 2011; 65: 1013-1020.
-
(2011)
Magn. Reson. Med.
, vol.65
, pp. 1013-1020
-
-
Du, J.1
Corbeil, J.2
Znamirowski, R.3
Angle, N.4
Peterson, M.5
Bydder, G.M.6
Kahn, A.M.7
-
79
-
-
46849108279
-
Improved slice selection for R2* mapping during cryoablation with eddy current compensation
-
Lu A, Daniel BL, Pauly JM, Pauly KB. Improved slice selection for R2* mapping during cryoablation with eddy current compensation. J. Magn. Reson. Imaging, 2008; 28: 190-198.
-
(2008)
J. Magn. Reson. Imaging
, vol.28
, pp. 190-198
-
-
Lu, A.1
Daniel, B.L.2
Pauly, J.M.3
Pauly, K.B.4
-
80
-
-
1242337463
-
Optimisation of T2 and M0 measurements of bi-exponential systems
-
Anastasiou A, Hall LD. Optimisation of T2 and M0 measurements of bi-exponential systems. Magn. Reson. Imaging 2004; 22: 67-80.
-
(2004)
Magn. Reson. Imaging
, vol.22
, pp. 67-80
-
-
Anastasiou, A.1
Hall, L.D.2
-
81
-
-
84855884320
-
Ultrashort echo time spectroscopic imaging (UTESI): an efficient method for quantifying bound and free water
-
Diaz E, Chung CB, Bae WC, Statum S, Znamirowski R, Bydder GM, Du J. Ultrashort echo time spectroscopic imaging (UTESI): an efficient method for quantifying bound and free water. NMR Biomed. 2012; 25: 161-168.
-
(2012)
NMR Biomed.
, vol.25
, pp. 161-168
-
-
Diaz, E.1
Chung, C.B.2
Bae, W.C.3
Statum, S.4
Znamirowski, R.5
Bydder, G.M.6
Du, J.7
-
82
-
-
84857365086
-
Ultrashort echo time imaging with bicomponent analysis
-
Du J, Diaz E, Carl M, Bae W, Chung C, Bydder GM. Ultrashort echo time imaging with bicomponent analysis. Magn. Reson. Med. 2012; 67: 645-649.
-
(2012)
Magn. Reson. Med.
, vol.67
, pp. 645-649
-
-
Du, J.1
Diaz, E.2
Carl, M.3
Bae, W.4
Chung, C.5
Bydder, G.M.6
-
84
-
-
84856976366
-
Ultrashort echo time (UTE) imaging with bicomponent analysis: bound and free water evaluation of bovine cortical bone subject to sequential drying
-
Biswas R, Bae W, Diaz E, Masuda K, Chung C, Bydder GM, Du J. Ultrashort echo time (UTE) imaging with bicomponent analysis: bound and free water evaluation of bovine cortical bone subject to sequential drying. Bone 2012; 50: 749-755.
-
(2012)
Bone
, vol.50
, pp. 749-755
-
-
Biswas, R.1
Bae, W.2
Diaz, E.3
Masuda, K.4
Chung, C.5
Bydder, G.M.6
Du, J.7
-
85
-
-
84863397896
-
Quantitative ultrashort echo time (UTE) MRI of human cortical bone: correlation with porosity and biomechanical properties
-
Epub ahead of print).
-
Bae WC, Chen PC, Chung CB, Masuda K, Lima D, Du J. Quantitative ultrashort echo time (UTE) MRI of human cortical bone: correlation with porosity and biomechanical properties. J. Bone Miner. Res. 2011; 27: 848-857 (Epub ahead of print).
-
(2011)
J. Bone Miner. Res.
, vol.27
, pp. 848-857
-
-
Bae, W.C.1
Chen, P.C.2
Chung, C.B.3
Masuda, K.4
Lima, D.5
Du, J.6
-
86
-
-
79251639225
-
Non-invasive predictors of human cortical bone mechanical properties: T-2-discriminated H-1 NMR compared with high resolution X-ray
-
Horch RA, Gochberg DF, Nyman JS, Does MD. Non-invasive predictors of human cortical bone mechanical properties: T-2-discriminated H-1 NMR compared with high resolution X-ray. PLoS One 2011; 6(1): e16359.
-
(2011)
PLoS One
, vol.6
, Issue.1
-
-
Horch, R.A.1
Gochberg, D.F.2
Nyman, J.S.3
Does, M.D.4
-
87
-
-
37349054707
-
Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of bone
-
Nyman JS, Ni Q, Nicolella DP, Wang X. Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of bone. Bone 2008; 42(1): 193-199.
-
(2008)
Bone
, vol.42
, Issue.1
, pp. 193-199
-
-
Nyman, J.S.1
Ni, Q.2
Nicolella, D.P.3
Wang, X.4
-
89
-
-
84876806787
-
-
Assessment of cortical bone structure with FSE, 2D and 3D UTE sequences. ISMRM Workshop: Advances in Musculoskeletal Magnetic Resonance Imaging, 16 February 2009, San Francisco, CA, USA
-
Du J, Bae W, Bydder CM, Takahashi A, Chung CB, Bydder GM. Assessment of cortical bone structure with FSE, 2D and 3D UTE sequences. ISMRM Workshop: Advances in Musculoskeletal Magnetic Resonance Imaging, 16 February 2009, San Francisco, CA, USA, 2009.
-
(2009)
-
-
Du, J.1
Bae, W.2
Bydder, C.M.3
Takahashi, A.4
Chung, C.B.5
Bydder, G.M.6
-
90
-
-
33751383444
-
Quantitative MRI for the assessment of bone structure and function
-
Wehrli FW, Song HK, Saha PK, Wright AC. Quantitative MRI for the assessment of bone structure and function. NMR Biomed. 2006; 19: 731-764.
-
(2006)
NMR Biomed.
, vol.19
, pp. 731-764
-
-
Wehrli, F.W.1
Song, H.K.2
Saha, P.K.3
Wright, A.C.4
-
92
-
-
0036217939
-
Diffusion of exchangeable water in cortical bone studies by nuclear magnetic resonance
-
Fernandez-Seara MA, Wehrli SL, Wehrli FW. Diffusion of exchangeable water in cortical bone studies by nuclear magnetic resonance. Biophys. J. 2002; 82: 522-529.
-
(2002)
Biophys. J.
, vol.82
, pp. 522-529
-
-
Fernandez-Seara, M.A.1
Wehrli, S.L.2
Wehrli, F.W.3
-
93
-
-
0035576307
-
Super-Osteons (remodeling clusters) in the cortex of the femoral shaft influence of age and gender
-
Bell KL, Loveridge N, Reever J, Thomas C, Feik SA, Clement JG. Super-Osteons (remodeling clusters) in the cortex of the femoral shaft influence of age and gender. Anat. Rec. 2001; 264: 378-386.
-
(2001)
Anat. Rec.
, vol.264
, pp. 378-386
-
-
Bell, K.L.1
Loveridge, N.2
Reever, J.3
Thomas, C.4
Feik, S.A.5
Clement, J.G.6
-
94
-
-
0027312482
-
Quantitative interpretation of magnetization transfer
-
Henkelman RM, Huang X, Xiang Q, Stanisz GJ, Swanson SD, Bronskill MJ. Quantitative interpretation of magnetization transfer. Magn. Reson. Med. 1993; 29: 759-766.
-
(1993)
Magn. Reson. Med.
, vol.29
, pp. 759-766
-
-
Henkelman, R.M.1
Huang, X.2
Xiang, Q.3
Stanisz, G.J.4
Swanson, S.D.5
Bronskill, M.J.6
-
96
-
-
0036999133
-
Precise estimation of fundamental in-vivo MT parameters in human brain in clinically feasible times
-
Ramani A, Dalton C, Miller DH, Tofts PS, Barker GJ. Precise estimation of fundamental in-vivo MT parameters in human brain in clinically feasible times. Magn. Reson. Imaging 2002; 20: 721-731.
-
(2002)
Magn. Reson. Imaging
, vol.20
, pp. 721-731
-
-
Ramani, A.1
Dalton, C.2
Miller, D.H.3
Tofts, P.S.4
Barker, G.J.5
-
97
-
-
84876794648
-
-
Preliminary results on bone perfusion measurement using dynamic contrast enhanced ultrashort TE imaging. Proceedings of the 19th Annual Meeting ISMRM, Montreal, QC, Canada
-
Girard O, Du J, Bydder GM, Mattrey R. Preliminary results on bone perfusion measurement using dynamic contrast enhanced ultrashort TE imaging. Proceedings of the 19th Annual Meeting ISMRM, Montreal, QC, Canada, 2011; 3210.
-
(2011)
, pp. 3210
-
-
Girard, O.1
Du, J.2
Bydder, G.M.3
Mattrey, R.4
-
98
-
-
0031404162
-
Modeling tracer kinetics in dynamic Gd-DTPA MR imaging
-
Tofts P. Modeling tracer kinetics in dynamic Gd-DTPA MR imaging. J. Magn. Reson. Imaging, 1997; 7: 91-101.
-
(1997)
J. Magn. Reson. Imaging
, vol.7
, pp. 91-101
-
-
Tofts, P.1
-
99
-
-
84869432194
-
Deuterium nuclear magnetic resonance unambiguously quantifies pore and collagen-bound water in cortical bone
-
in press.
-
Ong HH, Wright AC, Wehrli F. Deuterium nuclear magnetic resonance unambiguously quantifies pore and collagen-bound water in cortical bone. J. Bone Miner. Res. 2012; in press.
-
(2012)
J. Bone Miner. Res.
-
-
Ong, H.H.1
Wright, A.C.2
Wehrli, F.3
-
100
-
-
84870065097
-
Clinically-compatible MRI strategies for discriminating bound and pore water in cortical bone
-
Epub ahead of print).
-
Horch R, Gochberg D, Nyman J, Does M. Clinically-compatible MRI strategies for discriminating bound and pore water in cortical bone. Magn. Reson. Med. 2012; 68: 1774-1784 (Epub ahead of print).
-
(2012)
Magn. Reson. Med.
, vol.68
, pp. 1774-1784
-
-
Horch, R.1
Gochberg, D.2
Nyman, J.3
Does, M.4
-
101
-
-
77956360750
-
Ultrashort TE T1rho (UTE T1rho) imaging of the Achilles tendon and meniscus
-
Du J, Carl M, Diaz E, Takahashi A, Han E, Szeverenyi NM, Chung CB, Bydder GM. Ultrashort TE T1rho (UTE T1rho) imaging of the Achilles tendon and meniscus. Magn. Reson. Med. 2010; 64: 834-842.
-
(2010)
Magn. Reson. Med.
, vol.64
, pp. 834-842
-
-
Du, J.1
Carl, M.2
Diaz, E.3
Takahashi, A.4
Han, E.5
Szeverenyi, N.M.6
Chung, C.B.7
Bydder, G.M.8
-
102
-
-
77955110691
-
Optimization of RF excitation to maximize signal and T2 contrast of tissues with rapid transverse relaxation
-
Carl M, Bydder M, Du J, Takahashi A, Han E. Optimization of RF excitation to maximize signal and T2 contrast of tissues with rapid transverse relaxation. Magn. Reson. Med. 2010; 64: 481-490.
-
(2010)
Magn. Reson. Med.
, vol.64
, pp. 481-490
-
-
Carl, M.1
Bydder, M.2
Du, J.3
Takahashi, A.4
Han, E.5
-
104
-
-
36849088522
-
Sparse MRI: the application of compressed sensing for rapid MR imaging
-
Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn. Reson. Med. 2007; 58: 1182-1195.
-
(2007)
Magn. Reson. Med.
, vol.58
, pp. 1182-1195
-
-
Lustig, M.1
Donoho, D.2
Pauly, J.M.3
-
105
-
-
84876800213
-
-
Radial-Cones: a new sampling scheme for compressed sensing accelerated 3D ultrashort echo time imaging. Proceedings of the 20th Annual Meeting ISMRM, Melbourne, Australia
-
Johnson KM. Radial-Cones: a new sampling scheme for compressed sensing accelerated 3D ultrashort echo time imaging. Proceedings of the 20th Annual Meeting ISMRM, Melbourne, Australia, 2012; 285.
-
(2012)
, pp. 285
-
-
Johnson, K.M.1
-
106
-
-
84876812891
-
-
Compressed sensing 3D ultrashort echo time (COMPUTE) imaging. Proceedings of the 20th Annual Meeting ISMRM, Melbourne, Australia
-
Li C, Magland J, Wehrli F. Compressed sensing 3D ultrashort echo time (COMPUTE) imaging. Proceedings of the 20th Annual Meeting ISMRM, Melbourne, Australia, 2012; 1402.
-
(2012)
, pp. 1402
-
-
Li, C.1
Magland, J.2
Wehrli, F.3
|