메뉴 건너뛰기




Volumn 6, Issue 1, 2011, Pages

Non-invasive predictors of human cortical bone mechanical properties: T2-Discriminated 1H NMR compared with high resolution X-ray

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; BONE DENSITY; BONE RADIOGRAPHY; BONE STRESS; CADAVER; CLINICAL ASSESSMENT; CONTROLLED STUDY; CORTICAL BONE; FEMALE; HUMAN; HUMAN TISSUE; INTERMETHOD COMPARISON; MALE; MICRO-COMPUTED TOMOGRAPHY; NON INVASIVE PROCEDURE; PREDICTION; PROTON NUCLEAR MAGNETIC RESONANCE; RELAXATION TIME;

EID: 79251639225     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0016359     Document Type: Article
Times cited : (103)

References (21)
  • 1
    • 0035700603 scopus 로고    scopus 로고
    • Ten year probabilities of osteoporotic fractures according to BMD and diagnostic thresholds
    • Kanis JA, Johnell O, Oden A, Dawson A, De Laet C, et al. (2001) Ten year probabilities of osteoporotic fractures according to BMD and diagnostic thresholds. Osteoporos Int 12: 989-995.
    • (2001) Osteoporos Int , vol.12 , pp. 989-995
    • Kanis, J.A.1    Johnell, O.2    Oden, A.3    Dawson, A.4    De Laet, C.5
  • 3
    • 33847629923 scopus 로고    scopus 로고
    • Discrepancies in bone mineral density and fracture risk in patients with type 1 and type 2 diabetes-ameta-analysis
    • Vestergaard P (2007) Discrepancies in bone mineral density and fracture risk in patients with type 1 and type 2 diabetes-ameta-analysis.Osteoporos Int 18: 427-444.
    • (2007) Osteoporos Int , vol.18 , pp. 427-444
    • Vestergaard, P.1
  • 4
    • 0026586120 scopus 로고
    • New approaches for interpreting projected bone densitometry data
    • Carter DR, Bouxsein ML, Marcus R (1992) New approaches for interpreting projected bone densitometry data. J Bone Miner Res 7: 137-145.
    • (1992) J Bone Miner Res , vol.7 , pp. 137-145
    • Carter, D.R.1    Bouxsein, M.L.2    Marcus, R.3
  • 6
    • 32644452256 scopus 로고    scopus 로고
    • The influence of water removal on the strength and toughness of cortical bone
    • Nyman JS, Roy A, Shen XM, Acuna RL, Tyler JH, et al. (2006) The influence of water removal on the strength and toughness of cortical bone. Journal of Biomechanics 39: 931-938.
    • (2006) Journal of Biomechanics , vol.39 , pp. 931-938
    • Nyman, J.S.1    Roy, A.2    Shen, X.M.3    Acuna, R.L.4    Tyler, J.H.5
  • 7
    • 33846850575 scopus 로고    scopus 로고
    • Structural and functional assessment of trabecular and cortical bone by micro magnetic resonance imaging
    • Wehrli FW (2007) Structural and functional assessment of trabecular and cortical bone by micro magnetic resonance imaging. J Magn Reson Imaging 25: 390-409.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 390-409
    • Wehrli, F.W.1
  • 8
    • 37549071099 scopus 로고    scopus 로고
    • Magnetic resonance imaging for osteoporosis
    • Majumdar S (2008) Magnetic resonance imaging for osteoporosis. Skeletal Radiol 37: 95-97.
    • (2008) Skeletal Radiol , vol.37 , pp. 95-97
    • Majumdar, S.1
  • 9
    • 0031966115 scopus 로고    scopus 로고
    • Highresolution magnetic resonance imaging: Three-dimensional trabecular bone architecture and biomechanical properties
    • Majumdar S, Kothari M, Augat P, Newitt DC, Link TM, et al. (1998) Highresolution magnetic resonance imaging: three-dimensional trabecular bone architecture and biomechanical properties. Bone 22: 445-454.
    • (1998) Bone , vol.22 , pp. 445-454
    • Majumdar, S.1    Kothari, M.2    Augat, P.3    Newitt, D.C.4    Link, T.M.5
  • 10
    • 28544444873 scopus 로고    scopus 로고
    • Effect of ultrastructural changes on the toughness of bone
    • Nyman JS, Reyes M, Wang X (2005) Effect of ultrastructural changes on the toughness of bone. Micron 36: 566-582.
    • (2005) Micron , vol.36 , pp. 566-582
    • Nyman, J.S.1    Reyes, M.2    Wang, X.3
  • 11
    • 1642485801 scopus 로고    scopus 로고
    • Water content measured by proton-deuteron exchange NMR predicts bone mineral density and mechanical properties
    • Fernandez-Seara MA, Wehrli SL, Takahashi M, Wehrli FW (2004) Water content measured by proton-deuteron exchange NMR predicts bone mineral density and mechanical properties. J Bone Miner Res 19: 289-296.
    • (2004) J Bone Miner Res , vol.19 , pp. 289-296
    • Fernandez-Seara, M.A.1    Wehrli, S.L.2    Takahashi, M.3    Wehrli, F.W.4
  • 12
    • 37549009939 scopus 로고    scopus 로고
    • Diffusion-based MR methods for bone structure and evolution
    • Sigmund EE, Cho H, Chen P, Byrnes S, Song YQ, et al. (2008) Diffusion-based MR methods for bone structure and evolution. Magn Reson Med 59: 28-39.
    • (2008) Magn Reson Med , vol.59 , pp. 28-39
    • Sigmund, E.E.1    Cho, H.2    Chen, P.3    Byrnes, S.4    Song, Y.Q.5
  • 13
    • 37349054707 scopus 로고    scopus 로고
    • Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of bone
    • Nyman JS, Ni Q, Nicolella DP, Wang X (2008) Measurements of mobile and bound water by nuclear magnetic resonance correlate with mechanical properties of bone. Bone 42: 193-199.
    • (2008) Bone , vol.42 , pp. 193-199
    • Nyman, J.S.1    Ni, Q.2    Nicolella, D.P.3    Wang, X.4
  • 14
    • 33751368661 scopus 로고    scopus 로고
    • Clinical ultrashort echo time imaging of bone and other connective tissues
    • Robson MD, Bydder GM (2006) Clinical ultrashort echo time imaging of bone and other connective tissues. NMR in Biomedicine 19: 765-780.
    • (2006) NMR in Biomedicine , vol.19 , pp. 765-780
    • Robson, M.D.1    Bydder, G.M.2
  • 15
    • 35948947385 scopus 로고    scopus 로고
    • Using adiabatic inversion pulses for long-T-2 suppression in ultrashort echo time (UTE) imaging
    • Larson PEZ, Conolly SM, Pauly JM, Nishimura DG (2007) Using adiabatic inversion pulses for long-T-2 suppression in ultrashort echo time (UTE) imaging. Magnetic Resonance in Medicine 58: 952-961.
    • (2007) Magnetic Resonance in Medicine , vol.58 , pp. 952-961
    • Larson, P.E.Z.1    Conolly, S.M.2    Pauly, J.M.3    Nishimura, D.G.4
  • 16
    • 34247581820 scopus 로고    scopus 로고
    • Selective 3D ultrashort TE imaging: Comparison of "dual-echo" acquisition and magnetization preparation for improving short-T-2 contrast
    • Rahmer J, Blume U, Bornert P (2007) Selective 3D ultrashort TE imaging: comparison of "dual-echo" acquisition and magnetization preparation for improving short-T-2 contrast. Magnetic Resonance Materials in Physics Biology and Medicine 20: 83-92.
    • (2007) Magnetic Resonance Materials in Physics Biology and Medicine , vol.20 , pp. 83-92
    • Rahmer, J.1    Blume, U.2    Bornert, P.3
  • 17
    • 75749154996 scopus 로고    scopus 로고
    • Dual Inversion Recovery, Ultrashort Echo Time (DIR UTE) Imaging: Creating High Contrast for Short-T-2 Species
    • Du J, Takahashi AM, Bae WC, Chung CB, Bydder GM (2010) Dual Inversion Recovery, Ultrashort Echo Time (DIR UTE) Imaging: Creating High Contrast for Short-T-2 Species. Magnetic Resonance in Medicine 63: 447-455.
    • (2010) Magnetic Resonance in Medicine , vol.63 , pp. 447-455
    • Du, J.1    Takahashi, A.M.2    Bae, W.C.3    Chung, C.B.4    Bydder, G.M.5
  • 19
  • 21
    • 77953520506 scopus 로고    scopus 로고
    • Age- and Gender-Related Differences in the Geometric Properties and Biomechanical Significance of Intracortical Porosity in the Distal Radius and Tibia
    • Burghardt AJ, Kazakia GJ, Ramachandran S, Link TM, Majumdar S (2010) Age- and Gender-Related Differences in the Geometric Properties and Biomechanical Significance of Intracortical Porosity in the Distal Radius and Tibia. Journal of Bone and Mineral Research 25: 983-993.
    • (2010) Journal of Bone and Mineral Research , vol.25 , pp. 983-993
    • Burghardt, A.J.1    Kazakia, G.J.2    Ramachandran, S.3    Link, T.M.4    Majumdar, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.