메뉴 건너뛰기




Volumn 28, Issue 2, 2010, Pages 178-184

Orientational analysis of the Achilles tendon and enthesis using an ultrashort echo time spectroscopic imaging sequence

Author keywords

Bulk susceptibility; Enthesis; Magic angle; Short T2; Spectroscopic imaging; Tendon; Ultrashort TE

Indexed keywords

ACHILLES TENDON; ARTICLE; CONTROLLED STUDY; HUMAN; HUMAN TISSUE; IMAGE ANALYSIS; IMAGE ENHANCEMENT; IMAGE QUALITY; IMAGE RECONSTRUCTION; PRIORITY JOURNAL; PROSTHESIS; QUANTITATIVE STUDY; SENSITIVITY ANALYSIS; SIGNAL DETECTION; SPECTROSCOPY; THREE DIMENSIONAL IMAGING; ULTRASHORT ECHO TIME SPECTROSCOPY;

EID: 77349095247     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2009.06.002     Document Type: Article
Times cited : (53)

References (31)
  • 1
    • 33846804509 scopus 로고    scopus 로고
    • Collagen structure: the molecular source of the tendon magic angle effect
    • Fullerton G.D., Rahal A. Collagen structure: the molecular source of the tendon magic angle effect. J Magn Reson Imaging 2007, 25:345-361.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 345-361
    • Fullerton, G.D.1    Rahal, A.2
  • 2
    • 26944446604 scopus 로고    scopus 로고
    • Dependence of the spin-spin relaxation time of water in collagen gels on collagen fiber directions
    • Takeuchi M., Sekino M., Iriguchi N., Ueno S. Dependence of the spin-spin relaxation time of water in collagen gels on collagen fiber directions. Magn Reson Med Sci 2004, 3:153-157.
    • (2004) Magn Reson Med Sci , vol.3 , pp. 153-157
    • Takeuchi, M.1    Sekino, M.2    Iriguchi, N.3    Ueno, S.4
  • 3
    • 0021860864 scopus 로고
    • Orientation of tendons in the magnetic field and its effect on T2 relaxation time
    • Fullerton G.D., Cameron I.L., Ord V.A. Orientation of tendons in the magnetic field and its effect on T2 relaxation time. Radiology 1985, 155:433-435.
    • (1985) Radiology , vol.155 , pp. 433-435
    • Fullerton, G.D.1    Cameron, I.L.2    Ord, V.A.3
  • 6
    • 0026010198 scopus 로고
    • Effect of tendon orientation on MR imaging signal intensity: a manifestation of the "Magic Angle" phenomenon
    • Erickson S.J., Cox I.H., Hyde J.S., Carrera G.F., Strandt J.A., Estkowski L.D. Effect of tendon orientation on MR imaging signal intensity: a manifestation of the "Magic Angle" phenomenon. Radiology 1991, 181:389-392.
    • (1991) Radiology , vol.181 , pp. 389-392
    • Erickson, S.J.1    Cox, I.H.2    Hyde, J.S.3    Carrera, G.F.4    Strandt, J.A.5    Estkowski, L.D.6
  • 7
    • 0027200370 scopus 로고
    • The "magic angle" effect: background physics and clinical relevance
    • Erickson S.J., Prost R.W., Timins M.E. The "magic angle" effect: background physics and clinical relevance. Radiology 1993, 188:23-25.
    • (1993) Radiology , vol.188 , pp. 23-25
    • Erickson, S.J.1    Prost, R.W.2    Timins, M.E.3
  • 9
    • 33750596439 scopus 로고    scopus 로고
    • The magic-angle effect of the supraspinatus tendon
    • Madden M.E. The magic-angle effect of the supraspinatus tendon. Radiologic Technology 2006, 77:357-365.
    • (2006) Radiologic Technology , vol.77 , pp. 357-365
    • Madden, M.E.1
  • 10
    • 33748467383 scopus 로고    scopus 로고
    • Magic angle effect in MR imaging of ankle tendons: influence of foot positioning on prevalence and site in asymptomatic subjects and cadaveric tendons
    • Mengiardi B., Pfirrmann C.W., Schottle P.B., Bode B., Hodler J., Vienne P., et al. Magic angle effect in MR imaging of ankle tendons: influence of foot positioning on prevalence and site in asymptomatic subjects and cadaveric tendons. Eur Radiol 2006, 16:2197-2206.
    • (2006) Eur Radiol , vol.16 , pp. 2197-2206
    • Mengiardi, B.1    Pfirrmann, C.W.2    Schottle, P.B.3    Bode, B.4    Hodler, J.5    Vienne, P.6
  • 11
    • 0025876984 scopus 로고
    • Lung parenchyma: projection reconstruction MR imaging
    • Bergin C.J., Pauly J.M., Macovski A. Lung parenchyma: projection reconstruction MR imaging. Radiology 1991, 179:777-781.
    • (1991) Radiology , vol.179 , pp. 777-781
    • Bergin, C.J.1    Pauly, J.M.2    Macovski, A.3
  • 13
    • 40049083116 scopus 로고    scopus 로고
    • Two dimensional ultrashort echo time imaging using a spiral trajectory
    • Du J., Takahashi A., Bydder M., Chung C.B. Two dimensional ultrashort echo time imaging using a spiral trajectory. Magn Reson Imaging 2008, 26:304-312.
    • (2008) Magn Reson Imaging , vol.26 , pp. 304-312
    • Du, J.1    Takahashi, A.2    Bydder, M.3    Chung, C.B.4
  • 14
    • 33646447508 scopus 로고    scopus 로고
    • Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    • Rahmer J., Bornert P., Groen J., Bos C. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med 2006, 55:1075-1082.
    • (2006) Magn Reson Med , vol.55 , pp. 1075-1082
    • Rahmer, J.1    Bornert, P.2    Groen, J.3    Bos, C.4
  • 15
    • 3543122435 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences
    • Robson M.D., Benjamin M., Gishen P., Bydder G.M. Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences. Clin Radiol 2004, 59:727-735.
    • (2004) Clin Radiol , vol.59 , pp. 727-735
    • Robson, M.D.1    Benjamin, M.2    Gishen, P.3    Bydder, G.M.4
  • 16
    • 33846811674 scopus 로고    scopus 로고
    • Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences
    • Benjamin M., Bydder G.M. Magnetic resonance imaging of entheses using ultrashort TE (UTE) pulse sequences. J Magn Reson Imaging 2007, 25:381-389.
    • (2007) J Magn Reson Imaging , vol.25 , pp. 381-389
    • Benjamin, M.1    Bydder, G.M.2
  • 19
    • 60549101369 scopus 로고    scopus 로고
    • Ultrashort TE spectroscopic imaging (UTESI): application to the imaging of short T2 relaxation tissues in the musculoskeletal system
    • Du J., Takahashi A., Chung C.B. Ultrashort TE spectroscopic imaging (UTESI): application to the imaging of short T2 relaxation tissues in the musculoskeletal system. J Magn Reson Imaging 2009, 29:412-421.
    • (2009) J Magn Reson Imaging , vol.29 , pp. 412-421
    • Du, J.1    Takahashi, A.2    Chung, C.B.3
  • 21
    • 0028829261 scopus 로고
    • MR Spectroscopic imaging of collagen: tendons and knee menisci
    • Gold G.E., Pauly J.M., Macovski A., Herfkens R.J. MR Spectroscopic imaging of collagen: tendons and knee menisci. Magn Reson Med 1995, 34:647-654.
    • (1995) Magn Reson Med , vol.34 , pp. 647-654
    • Gold, G.E.1    Pauly, J.M.2    Macovski, A.3    Herfkens, R.J.4
  • 23
    • 0036708131 scopus 로고    scopus 로고
    • Time-resolved, undersampled projection reconstruction imaging for high resolution CE-MRA of the distal runoff vessels
    • Du J., Carroll T.J., Wagner H.J., Vigen K., Fain S.B., Block W.F., et al. Time-resolved, undersampled projection reconstruction imaging for high resolution CE-MRA of the distal runoff vessels. Magn Reson Med 2002, 48:516-522.
    • (2002) Magn Reson Med , vol.48 , pp. 516-522
    • Du, J.1    Carroll, T.J.2    Wagner, H.J.3    Vigen, K.4    Fain, S.B.5    Block, W.F.6
  • 24
    • 7044262262 scopus 로고    scopus 로고
    • Contrast enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction
    • Du J., Carroll T.J., Brodsky E., Lu A.M., Grist T.M., Mistretta C.A., et al. Contrast enhanced peripheral magnetic resonance angiography using time-resolved vastly undersampled isotropic projection reconstruction. J Magn Reson Imaging 2004, 20:894-900.
    • (2004) J Magn Reson Imaging , vol.20 , pp. 894-900
    • Du, J.1    Carroll, T.J.2    Brodsky, E.3    Lu, A.M.4    Grist, T.M.5    Mistretta, C.A.6
  • 28
    • 0031948923 scopus 로고    scopus 로고
    • Effects of gradient anisotropy in MRI
    • Aldefeld B., Bornert P. Effects of gradient anisotropy in MRI. Magn Reson Med 1998, 39:606-614.
    • (1998) Magn Reson Med , vol.39 , pp. 606-614
    • Aldefeld, B.1    Bornert, P.2
  • 29
    • 0034762213 scopus 로고    scopus 로고
    • Temperature mapping of frozen tissues using eddy current compensated half excitation RF pulses
    • Wansapura J.P., Daniel B.L., Pauly J., Butts K. Temperature mapping of frozen tissues using eddy current compensated half excitation RF pulses. Magn Reson Med 2001, 46:985-992.
    • (2001) Magn Reson Med , vol.46 , pp. 985-992
    • Wansapura, J.P.1    Daniel, B.L.2    Pauly, J.3    Butts, K.4
  • 30
    • 46849108279 scopus 로고    scopus 로고
    • Improved slice selection for R2* mapping during cryoablation with eddy current compensation
    • Lu A., Daniel B.L., Pauly J.M., Pauly K.B. Improved slice selection for R2* mapping during cryoablation with eddy current compensation. J Magn Reson Imaging 2008, 28:180-198.
    • (2008) J Magn Reson Imaging , vol.28 , pp. 180-198
    • Lu, A.1    Daniel, B.L.2    Pauly, J.M.3    Pauly, K.B.4
  • 31
    • 0001426032 scopus 로고
    • Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradient in NMR systems
    • Jehenson P., Westphal M., Schiff N. Analytical method for the compensation of eddy-current effects induced by pulsed magnetic field gradient in NMR systems. J Magn Reson 1990, 90:264-278.
    • (1990) J Magn Reson , vol.90 , pp. 264-278
    • Jehenson, P.1    Westphal, M.2    Schiff, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.