메뉴 건너뛰기




Volumn 28, Issue 1, 2008, Pages 190-198

Improved slice selection for R2* mapping during cryoablation with eddy current compensation

Author keywords

Cryoablation; Eddy current correction; Half pulse excitation; Temperature mapping; Ultra short TE imaging

Indexed keywords

ARTICLE; CRYOABLATION; DOG; FREEZING; IMAGE QUALITY; IMAGE RECONSTRUCTION; IN VIVO STUDY; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; RADIOFREQUENCY;

EID: 46849108279     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21396     Document Type: Article
Times cited : (50)

References (20)
  • 3
    • 3543122435 scopus 로고    scopus 로고
    • Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences
    • Robson MD, Benjamin M, Gishen P, Bydder GM. Magnetic resonance imaging of the Achilles tendon using ultrashort TE (UTE) pulse sequences. Clin Radiol 2004;59:727-735.
    • (2004) Clin Radiol , vol.59 , pp. 727-735
    • Robson, M.D.1    Benjamin, M.2    Gishen, P.3    Bydder, G.M.4
  • 5
    • 23844462238 scopus 로고    scopus 로고
    • In vivo thermometry of frozen tissue using R2* and signal intensity
    • Wansapura JP, Daniel BL, Vigen KK, Butts K. In vivo thermometry of frozen tissue using R2* and signal intensity. Acad Radiol 2005; 12:1080-1084.
    • (2005) Acad Radiol , vol.12 , pp. 1080-1084
    • Wansapura, J.P.1    Daniel, B.L.2    Vigen, K.K.3    Butts, K.4
  • 10
    • 0034762213 scopus 로고    scopus 로고
    • Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses
    • Wansapura J, Daniel BL, Pauly JM, Butts K. Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses. Magn Reson Med 2001;46:985-992.
    • (2001) Magn Reson Med , vol.46 , pp. 985-992
    • Wansapura, J.1    Daniel, B.L.2    Pauly, J.M.3    Butts, K.4
  • 11
    • 0037925300 scopus 로고    scopus 로고
    • Centering the projection reconstruction trajectory: Reducing gradient delay errors
    • Peters DC, Derbyshire JA, McVeigh ER. Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 2003;50:1-6.
    • (2003) Magn Reson Med , vol.50 , pp. 1-6
    • Peters, D.C.1    Derbyshire, J.A.2    McVeigh, E.R.3
  • 12
    • 0038621306 scopus 로고    scopus 로고
    • The use of measured k-space trajectory for reconstruction of radial MRI data
    • Hawaii
    • Dale BM, Duerk JL. The use of measured k-space trajectory for reconstruction of radial MRI data. In: Proc 10th Annual Meeting ISMRM, Hawaii, 2002. p 2334.
    • (2002) Proc 10th Annual Meeting ISMRM , pp. 2334
    • Dale, B.M.1    Duerk, J.L.2
  • 13
    • 0032059889 scopus 로고    scopus 로고
    • Simple correction method for k-space trajectory deviations in MRI
    • Duyn JH, Yang Y, Frank JA, Veen JW. Simple correction method for k-space trajectory deviations in MRI. J Magn Reson 1998;132: 150-153.
    • (1998) J Magn Reson , vol.132 , pp. 150-153
    • Duyn, J.H.1    Yang, Y.2    Frank, J.A.3    Veen, J.W.4
  • 15
    • 14744296815 scopus 로고    scopus 로고
    • Rapid fat suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction
    • Lu A, Grist TM, Block WF. Rapid fat suppressed isotropic steady-state free precession imaging using true 3D multiple-half-echo projection reconstruction. Magn Reson Med 2005;53:692-699.
    • (2005) Magn Reson Med , vol.53 , pp. 692-699
    • Lu, A.1    Grist, T.M.2    Block, W.F.3
  • 19
    • 33846101573 scopus 로고    scopus 로고
    • Consistent non-Cartesian off-axis MRI quality: Calibrating and removing multiple sources of demodulation phase errors
    • Jung Y, Jashnani Y, Kijowski R, Block WF. Consistent non-Cartesian off-axis MRI quality: calibrating and removing multiple sources of demodulation phase errors. Magn Reson Med 2007;57: 206-212.
    • (2007) Magn Reson Med , vol.57 , pp. 206-212
    • Jung, Y.1    Jashnani, Y.2    Kijowski, R.3    Block, W.F.4
  • 20
    • 33646447508 scopus 로고    scopus 로고
    • Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
    • Rahmer, J, Bornert P, Groen J, Bos C. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med 2006;55:1075-1082.
    • (2006) Magn Reson Med , vol.55 , pp. 1075-1082
    • Rahmer, J.1    Bornert, P.2    Groen, J.3    Bos, C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.