-
2
-
-
0021850318
-
High resolution NMR imaging in solids
-
Emid S., and Creyghton J.H.N. High resolution NMR imaging in solids. Physica B 128 (1985) 81-83
-
(1985)
Physica B
, vol.128
, pp. 81-83
-
-
Emid, S.1
Creyghton, J.H.N.2
-
3
-
-
33646777487
-
Single-point ramped imaging with T1 enhancement (SPRITE)
-
Balcom B.J., MacGregor R.P., Beyea S.D., Green D.P., Armstrong R.L., and Bremner T.W. Single-point ramped imaging with T1 enhancement (SPRITE). J Magn Reson A 123 (1996) 131-134
-
(1996)
J Magn Reson A
, vol.123
, pp. 131-134
-
-
Balcom, B.J.1
MacGregor, R.P.2
Beyea, S.D.3
Green, D.P.4
Armstrong, R.L.5
Bremner, T.W.6
-
5
-
-
0037925188
-
Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI
-
Wu Y., Ackerman J.L., Chesler D.A., Graham L., Wang Y., and Glimcher M.J. Density of organic matrix of native mineralized bone measured by water- and fat-suppressed proton projection MRI. Magn Reson Med 50 (2003) 59-68
-
(2003)
Magn Reson Med
, vol.50
, pp. 59-68
-
-
Wu, Y.1
Ackerman, J.L.2
Chesler, D.A.3
Graham, L.4
Wang, Y.5
Glimcher, M.J.6
-
6
-
-
0025876984
-
Lung parenchyma: projection reconstruction MR imaging
-
Bergin C.J., Pauly J.M., and Macovski A. Lung parenchyma: projection reconstruction MR imaging. Radiology 179 (1991) 777-781
-
(1991)
Radiology
, vol.179
, pp. 777-781
-
-
Bergin, C.J.1
Pauly, J.M.2
Macovski, A.3
-
8
-
-
0033026560
-
Ultra-short echo-time 2D time-of-flight MR angiography using a half-pulse excitation
-
Nielsen H.T.C., Gold G.E., Olcott E.W., Pauly J.M., and Nishimura D.G. Ultra-short echo-time 2D time-of-flight MR angiography using a half-pulse excitation. Magn Reson Med 41 (1999) 591-599
-
(1999)
Magn Reson Med
, vol.41
, pp. 591-599
-
-
Nielsen, H.T.C.1
Gold, G.E.2
Olcott, E.W.3
Pauly, J.M.4
Nishimura, D.G.5
-
9
-
-
0037236412
-
Magnetic resonance imaging of short T2 components in tissues
-
Gatehouse P.D., and Bydder G.M. Magnetic resonance imaging of short T2 components in tissues. Clin Radiol 58 (2003) 1-19
-
(2003)
Clin Radiol
, vol.58
, pp. 1-19
-
-
Gatehouse, P.D.1
Bydder, G.M.2
-
10
-
-
0347917187
-
MRI of the brain with ultra-short echo-time pulse sequences
-
Waldman A., Rees J.H., Brock C.S., Robson M.D., Gatehouse P.D., and Bydder G.M. MRI of the brain with ultra-short echo-time pulse sequences. Neuroradiology 45 (2003) 887-892
-
(2003)
Neuroradiology
, vol.45
, pp. 887-892
-
-
Waldman, A.1
Rees, J.H.2
Brock, C.S.3
Robson, M.D.4
Gatehouse, P.D.5
Bydder, G.M.6
-
11
-
-
4644370568
-
Contrast-enhanced MRI of the menisci of the knee using ultrashort echo time (UTE) pulse sequences: imaging of the red and white zones
-
Gatehouse P.D., He T., Puri B.K., Thomas R.D., Resnick D., and Bydder G.M. Contrast-enhanced MRI of the menisci of the knee using ultrashort echo time (UTE) pulse sequences: imaging of the red and white zones. Br J Radiol 77 (2004) 641-647
-
(2004)
Br J Radiol
, vol.77
, pp. 641-647
-
-
Gatehouse, P.D.1
He, T.2
Puri, B.K.3
Thomas, R.D.4
Resnick, D.5
Bydder, G.M.6
-
12
-
-
0347595433
-
Magnetic resonance imaging of periosteum with Ultrashort TE pulse sequences
-
Reichert I.L.H., Benjamin M., Gatehouse P.D., He T., Chappell K.E., Holmes J., et al. Magnetic resonance imaging of periosteum with Ultrashort TE pulse sequences. J Magn Reson Imaging 19 (2004) 99-107
-
(2004)
J Magn Reson Imaging
, vol.19
, pp. 99-107
-
-
Reichert, I.L.H.1
Benjamin, M.2
Gatehouse, P.D.3
He, T.4
Chappell, K.E.5
Holmes, J.6
-
13
-
-
33646438018
-
Ultra-Short TE imaging with single-digit (8 microsecond) TE
-
Brittain J.H., Shankaranarayanan A., Ramanan V., Shimakawa A., Cunningham C.H., Hinks S., et al. Ultra-Short TE imaging with single-digit (8 microsecond) TE. Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan (2004) 629
-
(2004)
Proceedings of the 12th Annual Meeting of ISMRM, Kyoto, Japan
, pp. 629
-
-
Brittain, J.H.1
Shankaranarayanan, A.2
Ramanan, V.3
Shimakawa, A.4
Cunningham, C.H.5
Hinks, S.6
-
14
-
-
40049102991
-
Multi-echo ultrashort TE (UTE) imaging and T2* mapping of knee cartilage
-
Du J., Takahashi A.M., Shimakawa A., Brittain J.H., Bydder M., and Bydder G.M. Multi-echo ultrashort TE (UTE) imaging and T2* mapping of knee cartilage. Proceedings of the 14th Annual Meeting of ISMRM, Seattle, USA (2006) 57
-
(2006)
Proceedings of the 14th Annual Meeting of ISMRM, Seattle, USA
, pp. 57
-
-
Du, J.1
Takahashi, A.M.2
Shimakawa, A.3
Brittain, J.H.4
Bydder, M.5
Bydder, G.M.6
-
17
-
-
33751367390
-
Magnetic resonance imaging: improved visualization of bone with Ultrashort (UTE) pulse sequences
-
Bydder M., Robson M.D., Gatehouse P.D., Znamirowski R.M., Benjamin M., and Bydder G.M. Magnetic resonance imaging: improved visualization of bone with Ultrashort (UTE) pulse sequences. Proceedings of the 13th Annual Meeting of the ISMRM, Miami, USA (2005) 1989
-
(2005)
Proceedings of the 13th Annual Meeting of the ISMRM, Miami, USA
, pp. 1989
-
-
Bydder, M.1
Robson, M.D.2
Gatehouse, P.D.3
Znamirowski, R.M.4
Benjamin, M.5
Bydder, G.M.6
-
18
-
-
33646447508
-
Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling
-
Rahmer J., Bornert P., Groen J., and Bos C. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med 55 (2006) 1075-1082
-
(2006)
Magn Reson Med
, vol.55
, pp. 1075-1082
-
-
Rahmer, J.1
Bornert, P.2
Groen, J.3
Bos, C.4
-
19
-
-
0029095343
-
Optimized gradient waveforms for spiral scanning
-
King K.F., Foo T.K.F., and Crawford C.R. Optimized gradient waveforms for spiral scanning. Magn Reson Med 34 (1995) 156-160
-
(1995)
Magn Reson Med
, vol.34
, pp. 156-160
-
-
King, K.F.1
Foo, T.K.F.2
Crawford, C.R.3
-
20
-
-
0034762213
-
Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses
-
Wanspaura J.P., Daniel B.L., Pauly J.M., and Butts K. Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses. Magn Reson Med 46 (2001) 985-992
-
(2001)
Magn Reson Med
, vol.46
, pp. 985-992
-
-
Wanspaura, J.P.1
Daniel, B.L.2
Pauly, J.M.3
Butts, K.4
-
21
-
-
0026696668
-
Twisting radial lines with application to robust magnetic resonance imaging of irregular flow
-
Jackson J.I., Nishimura D.G., and Macovski A. Twisting radial lines with application to robust magnetic resonance imaging of irregular flow. Magn Reson Med 25 (1992) 128-139
-
(1992)
Magn Reson Med
, vol.25
, pp. 128-139
-
-
Jackson, J.I.1
Nishimura, D.G.2
Macovski, A.3
-
22
-
-
33745693133
-
Suppression of long T2 components for short T2 imaging
-
Pauly J.M., Conolly S.M., and Macovski A. Suppression of long T2 components for short T2 imaging. Proceedings of the 10th Annual Meeting of SMRI, New York, USA (1992) 330
-
(1992)
Proceedings of the 10th Annual Meeting of SMRI, New York, USA
, pp. 330
-
-
Pauly, J.M.1
Conolly, S.M.2
Macovski, A.3
-
23
-
-
0031593443
-
Design of practical T2-selective RF excitation (TELEX) pulses
-
Sussman M.S., Pauly J.M., and Wright G.A. Design of practical T2-selective RF excitation (TELEX) pulses. Magn Reson Med 40 (1998) 890-899
-
(1998)
Magn Reson Med
, vol.40
, pp. 890-899
-
-
Sussman, M.S.1
Pauly, J.M.2
Wright, G.A.3
-
24
-
-
33745713979
-
Designing long-T2 suppression pulses for ultrashort echo time imaging
-
Larson P.E., Gurney P.T., Nayak K., Gold G.E., Pauly J.M., and Nishimura D.G. Designing long-T2 suppression pulses for ultrashort echo time imaging. Magn Reson Med 56 (2006) 94-103
-
(2006)
Magn Reson Med
, vol.56
, pp. 94-103
-
-
Larson, P.E.1
Gurney, P.T.2
Nayak, K.3
Gold, G.E.4
Pauly, J.M.5
Nishimura, D.G.6
-
25
-
-
48549111126
-
Highly selective π/2 and π pulse generation
-
Silver M.S., Joseph R.I., and Hoult D.I. Highly selective π/2 and π pulse generation. J Magn Reson 59 (1984) 347-351
-
(1984)
J Magn Reson
, vol.59
, pp. 347-351
-
-
Silver, M.S.1
Joseph, R.I.2
Hoult, D.I.3
-
26
-
-
0026320313
-
Fast selective black blood MR imaging
-
Edelman R.R., Chien D., and Kim D. Fast selective black blood MR imaging. Radiology 181 (1991) 655-660
-
(1991)
Radiology
, vol.181
, pp. 655-660
-
-
Edelman, R.R.1
Chien, D.2
Kim, D.3
-
27
-
-
33744953576
-
Correction for gradient amplifier hysteresis artifacts in spiral scans
-
King K.F., Gai N., Ganin A., and Glover G.H. Correction for gradient amplifier hysteresis artifacts in spiral scans. Proceedings of the 8th Annual Meeting of ISMRM, Denver, USA (2000) 336
-
(2000)
Proceedings of the 8th Annual Meeting of ISMRM, Denver, USA
, pp. 336
-
-
King, K.F.1
Gai, N.2
Ganin, A.3
Glover, G.H.4
-
28
-
-
0031895850
-
Gradient characterization using a Fourier-transform technique
-
Ally M.T., Glover G.H., and Pelc N.J. Gradient characterization using a Fourier-transform technique. Magn Reson Med 39 (1998) 581-587
-
(1998)
Magn Reson Med
, vol.39
, pp. 581-587
-
-
Ally, M.T.1
Glover, G.H.2
Pelc, N.J.3
-
29
-
-
0031837476
-
A novel k-space trajectory measurement technique
-
Zhang Y., Hetherington H.P., Stokely E.M., Mason G.F., and Twieg D.B. A novel k-space trajectory measurement technique. Magn Reson Med 39 (1998) 999-1004
-
(1998)
Magn Reson Med
, vol.39
, pp. 999-1004
-
-
Zhang, Y.1
Hetherington, H.P.2
Stokely, E.M.3
Mason, G.F.4
Twieg, D.B.5
-
30
-
-
0032059889
-
Simple correction method for k-space trajectory deviations in MRI
-
Duyn J.H., Yang Y.H., Frank J.A., and Veen J.W. Simple correction method for k-space trajectory deviations in MRI. J Magn Reson 132 (1998) 150-153
-
(1998)
J Magn Reson
, vol.132
, pp. 150-153
-
-
Duyn, J.H.1
Yang, Y.H.2
Frank, J.A.3
Veen, J.W.4
-
31
-
-
0037925300
-
Centering the projection reconstruction trajectory: reducing gradient delay errors
-
Peters D.C., Derbyshire J.A., and McVeigh E.R. Centering the projection reconstruction trajectory: reducing gradient delay errors. Magn Reson Med 50 (2003) 1-6
-
(2003)
Magn Reson Med
, vol.50
, pp. 1-6
-
-
Peters, D.C.1
Derbyshire, J.A.2
McVeigh, E.R.3
-
32
-
-
0020619692
-
Experimental simulation evaluation of ECG-gated heart scans with a small number of views
-
Joseph P.M., and Whitley J. Experimental simulation evaluation of ECG-gated heart scans with a small number of views. Med Phys 10 (1983) 444-449
-
(1983)
Med Phys
, vol.10
, pp. 444-449
-
-
Joseph, P.M.1
Whitley, J.2
-
33
-
-
0033971791
-
Undersampled projection reconstruction applied to MR angiography
-
Peters D.C., Korosec F.R., Grist T.M., Block W.F., Holden J.E., Vigen K.K., et al. Undersampled projection reconstruction applied to MR angiography. Magn Reson Med 43 (2000) 91-101
-
(2000)
Magn Reson Med
, vol.43
, pp. 91-101
-
-
Peters, D.C.1
Korosec, F.R.2
Grist, T.M.3
Block, W.F.4
Holden, J.E.5
Vigen, K.K.6
-
35
-
-
0026878097
-
Deblurring for non-2D Fourier transform magnetic resonance imaging
-
Noll D.C., Pauly J.M., Meyer C.H., Nishimura D.G., and Macovski A. Deblurring for non-2D Fourier transform magnetic resonance imaging. Magn Reson Med 25 (1992) 319-333
-
(1992)
Magn Reson Med
, vol.25
, pp. 319-333
-
-
Noll, D.C.1
Pauly, J.M.2
Meyer, C.H.3
Nishimura, D.G.4
Macovski, A.5
|