메뉴 건너뛰기




Volumn 39, Issue 1, 2013, Pages 23-29

Effect of model parameters on finite element analysis of micromotions in implant dentistry

Author keywords

Dental implantation; Immediate dental implant loading; Motion; Osseointegration

Indexed keywords

ARTICLE; BIOLOGICAL MODEL; BONE REGENERATION; DENTAL ABUTMENT; DENTAL PROCEDURE; FINITE ELEMENT ANALYSIS; FRICTION; HUMAN; METHODOLOGY; MOVEMENT (PHYSIOLOGY); STATISTICAL MODEL; TOOTH IMPLANT; TOOTH IMPLANTATION; YOUNG MODULUS;

EID: 84875485147     PISSN: 01606972     EISSN: 15481336     Source Type: Journal    
DOI: 10.1563/AAID-JOI-D-11-00221     Document Type: Article
Times cited : (42)

References (24)
  • 1
    • 36849023382 scopus 로고    scopus 로고
    • Influence of connection geometry on dynamic micromotion at the implant-abutment interface
    • Meng JC, Everts JE, Qian F, Gratton DG. Influence of connection geometry on dynamic micromotion at the implant-abutment interface. Int J Prosthodont. 2007;20:623-625.
    • (2007) Int J Prosthodont. , vol.20 , pp. 623-625
    • Meng, J.C.1    Everts, J.E.2    Qian, F.3    Gratton, D.G.4
  • 2
    • 85047681494 scopus 로고    scopus 로고
    • Micromotion and dynamic fatigue properties of the dental implant-abutment interface
    • Gratton DG, Aquilino SA, Stanford CM. Micromotion and dynamic fatigue properties of the dental implant-abutment interface. J Prosthet Dent. 2001;85:47-52.
    • (2001) J Prosthet Dent. , vol.85 , pp. 47-52
    • Gratton, D.G.1    Aquilino, S.A.2    Stanford, C.M.3
  • 4
    • 30844432439 scopus 로고    scopus 로고
    • In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems
    • Steinebrunner L, Wolfart S, Bössmann K, Kern M. In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems. Int J Oral Maxillofac Implants. 2005;20:875-881.
    • (2005) Int J Oral Maxillofac Implants , vol.20 , pp. 875-881
    • Steinebrunner, L.1    Wolfart, S.2    Bössmann, K.3    Kern, M.4
  • 5
    • 0029377916 scopus 로고
    • Comparison of screw loosening, rotation, and deflection among three implant designs
    • Dixon DL, Breeding LC, Sadler JP, McKay ML. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent. 1995;74:270-278.
    • (1995) J Prosthet Dent. , vol.74 , pp. 270-278
    • Dixon, D.L.1    Breeding, L.C.2    Sadler, J.P.3    McKay, M.L.4
  • 6
    • 0033074393 scopus 로고    scopus 로고
    • Assessment of cold welding properties of the internal conical interface of two commercially available implant systems
    • Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent. 1999;81:159-166.
    • (1999) J Prosthet Dent. , vol.81 , pp. 159-166
    • Norton, M.R.1
  • 7
    • 0034186179 scopus 로고    scopus 로고
    • In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems
    • Norton MR. In vitro evaluation of the strength of the conical implant-to-abutment joint in two commercially available implant systems. J Prosthet Dent. 2000;83:567-571.
    • (2000) J Prosthet Dent. , vol.83 , pp. 567-571
    • Norton, M.R.1
  • 8
    • 3242884501 scopus 로고    scopus 로고
    • Present status of immediate loading of oral implants
    • Romanos GE. Present status of immediate loading of oral implants. J Oral Implantol. 2004;30:189-197.
    • (2004) J Oral Implantol. , vol.30 , pp. 189-197
    • Romanos, G.E.1
  • 9
    • 34249782310 scopus 로고    scopus 로고
    • The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip
    • Udofia I, Liu F, Jin Z, Roberts P, Grigoris P. The initial stability and contact mechanics of a press-fit resurfacing arthroplasty of the hip. J Bone Joint Surg Br. 2007;89:549-556.
    • (2007) J Bone Joint Surg Br. , vol.89 , pp. 549-556
    • Udofia, I.1    Liu, F.2    Jin, Z.3    Roberts, P.4    Grigoris, P.5
  • 10
    • 0031309247 scopus 로고    scopus 로고
    • Influence of bone quality on stress distribution for endosseous implants
    • Holmes DC, Loftus JT. Influence of bone quality on stress distribution for endosseous implants. J Oral Implantol. 1997;23:104-111.
    • (1997) J Oral Implantol. , vol.23 , pp. 104-111
    • Holmes, D.C.1    Loftus, J.T.2
  • 11
    • 50349101986 scopus 로고    scopus 로고
    • The effect of provisional restoration type on micromovement of implants
    • Holst S, Geiselhoeringer H, Wichmann M, Holst AI. The effect of provisional restoration type on micromovement of implants. J Prosthet Dent. 2008;100:173-182.
    • (2008) J Prosthet Dent. , vol.100 , pp. 173-182
    • Holst, S.1    Geiselhoeringer, H.2    Wichmann, M.3    Holst, A.I.4
  • 12
    • 0042760299 scopus 로고    scopus 로고
    • Osseointegration under immediate loading: Biome-chanical stress-strain and bone formation - Resorption
    • Kawahara H, Kawahara D, Hayakawa M, Tamai Y, Kuremoto T, Matsuda S. Osseointegration under immediate loading: biome-chanical stress-strain and bone formation - resorption. Implant Dent. 2003;12:61-68.
    • (2003) Implant Dent. , vol.12 , pp. 61-68
    • Kawahara, H.1    Kawahara, D.2    Hayakawa, M.3    Tamai, Y.4    Kuremoto, T.5    Matsuda, S.6
  • 13
    • 0033140443 scopus 로고    scopus 로고
    • In vivo bone response to biomechanical loading at the bone/dental-implant interface
    • Brunski JB. In vivo bone response to biomechanical loading at the bone/dental-implant interface. Adv Dent Res. 1999;13:99-119.
    • (1999) Adv Dent Res. , vol.13 , pp. 99-119
    • Brunski, J.B.1
  • 14
    • 0032102958 scopus 로고    scopus 로고
    • Timing of loading and effect of micromotion on bone-dental implant interface: Review of experimental literature
    • Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. Timing of loading and effect of micromotion on bone-dental implant interface: review of experimental literature. J Biomed Mater Res. 1998;43:192-203.
    • (1998) J Biomed Mater Res. , vol.43 , pp. 192-203
    • Szmukler-Moncler, S.1    Salama, H.2    Reingewirtz, Y.3    Dubruille, J.H.4
  • 15
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler S, Piattelli A, Favero GA, Dubruille JH. Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clin Oral Implants Res. 2000;11:12-25.
    • (2000) Clin Oral Implants Res. , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 17
    • 2342577562 scopus 로고    scopus 로고
    • In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy
    • Engelke W, Decco OA, Rau MJ, Massoni MC, Schwarzwäller W. In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy. Implant Dent. 2004;13:88-94.
    • (2004) Implant Dent. , vol.13 , pp. 88-94
    • Engelke, W.1    Decco, O.A.2    Rau, M.J.3    Massoni, M.C.4    Schwarzwäller, W.5
  • 18
    • 0343052959 scopus 로고    scopus 로고
    • Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses
    • Bühler DW, Oxland TR, Nolte LP. Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses. Med Eng Phys. 1997;19:187-199.
    • (1997) Med Eng Phys. , vol.19 , pp. 187-199
    • Bühler, D.W.1    Oxland, T.R.2    Nolte, L.P.3
  • 19
    • 50849107348 scopus 로고    scopus 로고
    • The influence of abutment angulation on micromotion level for immediately loaded dental implants: A 3-D finite element analysis
    • Kao HC, Gung YW, Chung TF, Hsu ML. The influence of abutment angulation on micromotion level for immediately loaded dental implants: a 3-D finite element analysis. Int J Oral Maxillofac Implants. 2008;23:623-630.
    • (2008) Int J Oral Maxillofac Implants , vol.23 , pp. 623-630
    • Kao, H.C.1    Gung, Y.W.2    Chung, T.F.3    Hsu, M.L.4
  • 20
    • 77955909209 scopus 로고    scopus 로고
    • Parameters of implant stability measurements based on resonance frequency and damping capacity: A comparative finite element analysis
    • Winter W, Möhrle S, Holst S, Karl M. Parameters of implant stability measurements based on resonance frequency and damping capacity: a comparative finite element analysis. Int J Oral Maxillofac Implants. 2010;25:532-539.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 532-539
    • Winter, W.1    Möhrle, S.2    Holst, S.3    Karl, M.4
  • 21
    • 80053079936 scopus 로고    scopus 로고
    • Effect of geometric parameters on finite element analysis of bone loading caused by nonpassively fitting implant-supported dental restorations
    • Winter W, Steinmann P, Holst S, Karl M. Effect of geometric parameters on finite element analysis of bone loading caused by nonpassively fitting implant-supported dental restorations. Quintessence Int. 2011;42:471-478.
    • (2011) Quintessence Int. , vol.42 , pp. 471-478
    • Winter, W.1    Steinmann, P.2    Holst, S.3    Karl, M.4
  • 23
    • 68149100001 scopus 로고    scopus 로고
    • Parametric analysis of the strength in the '''Toronto''' osseous-prosthesis system
    • Cicciù M, Risitano G, Maiorana C, Franceschini G. Parametric analysis of the strength in the '''Toronto''' osseous-prosthesis system. Minerva Stomatol. 2009;58:9-23.
    • (2009) Minerva Stomatol. , vol.58 , pp. 9-23
    • Cicciù, M.1    Risitano, G.2    Maiorana, C.3    Franceschini, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.