메뉴 건너뛰기




Volumn 20, Issue 5, 2009, Pages 467-471

Implant micromotion is related to peak insertion torque and bone density

Author keywords

Bone density; Dental implant; Immediate loading; Insertion torque; Micromotion; Primary stability

Indexed keywords

ANIMAL; ARTICLE; BONE DENSITY; CATTLE; COMPARATIVE STUDY; DENTAL CARE; DENTAL SURGERY; METHODOLOGY; TOOTH IMPLANTATION; TORQUE;

EID: 64549138551     PISSN: 09057161     EISSN: 16000501     Source Type: Journal    
DOI: 10.1111/j.1600-0501.2008.01679.x     Document Type: Article
Times cited : (231)

References (22)
  • 1
    • 0027023659 scopus 로고
    • Issues in bone mechanics related to oral implants
    • Bidez, M.W. Misch, C.E. (1992) Issues in bone mechanics related to oral implants. Implant Dentistry 1 : 289 294.
    • (1992) Implant Dentistry , vol.1 , pp. 289-294
    • Bidez, M.W.1    Misch, C.E.2
  • 2
    • 0033140443 scopus 로고    scopus 로고
    • In vivo bone response to biomechanical loading at the bone/dental-implant interface
    • Brunski, J.B. (1999) In vivo bone response to biomechanical loading at the bone/dental-implant interface. Advances in Dental Research 13 : 99 119.
    • (1999) Advances in Dental Research , vol.13 , pp. 99-119
    • Brunski, J.B.1
  • 4
    • 2342577562 scopus 로고    scopus 로고
    • In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy
    • Engelke, W., Decco, O.A., Rau, M.J., Massoni, M.C. Schwarzwaller, W. (2004) In vitro evaluation of horizontal implant micromovement in bone specimen with contact endoscopy. Implant Dentistry 13 : 88 94.
    • (2004) Implant Dentistry , vol.13 , pp. 88-94
    • Engelke, W.1    Decco, O.A.2    Rau, M.J.3    Massoni, M.C.4    Schwarzwaller, W.5
  • 6
    • 0347667233 scopus 로고
    • Occlusal forces during function
    • In. Rowlands, C.C. ed. Ann Arbor. University of Michigan Press.
    • Graf, H. (1975) Occlusal forces during function. In : Rowlands, C.C., ed. Occlusion: Research on Form and Function, 90 110. Ann Arbor : University of Michigan Press.
    • (1975) Occlusion: Research on Form and Function , pp. 90-110
    • Graf, H.1
  • 7
    • 33748302973 scopus 로고    scopus 로고
    • The first EAO consensus conference 16-19 February 2006, Pfaffikon, Schwyz, Switzerland
    • Hammerle, H.F. van Steenberghe, D. (2006) The first EAO consensus conference 16-19 February 2006, Pfaffikon, Schwyz, Switzerland. Clinical Oral Implant Research 17 (Suppl. 2) : 1.
    • (2006) Clinical Oral Implant Research , vol.17 , Issue.SUPPL. 2 , pp. 1
    • Hammerle, H.F.1    Van Steenberghe, D.2
  • 8
    • 0011791493 scopus 로고    scopus 로고
    • Der Einfluss einer zeitlich limitierten kontrollierten Bewegung auf die Fraktureilung
    • Hente, R., Lechner, J., Fuechtmeier, B., Schlegel, U. Perren, S.M. (2001) Der Einfluss einer zeitlich limitierten kontrollierten Bewegung auf die Fraktureilung. Hefte Unfallchirurg 283 : 23 24.
    • (2001) Hefte Unfallchirurg , vol.283 , pp. 23-24
    • Hente, R.1    Lechner, J.2    Fuechtmeier, B.3    Schlegel, U.4    Perren, S.M.5
  • 9
    • 4644291445 scopus 로고    scopus 로고
    • Biomechanical aspects of marginal bone resorption around osseointegrated implants: Considerations based on a three-dimensional finite element analysis
    • Kitamura, E., Stegaroiu, R., Nomura, S. Miyakawa, O. (2004) Biomechanical aspects of marginal bone resorption around osseointegrated implants: considerations based on a three-dimensional finite element analysis. Clinical Oral Implants Research 15 : 401 412.
    • (2004) Clinical Oral Implants Research , vol.15 , pp. 401-412
    • Kitamura, E.1    Stegaroiu, R.2    Nomura, S.3    Miyakawa, O.4
  • 10
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants: A human cadaver study
    • O'Sullivan, D., Sennerby, L. Meredith, N. (2000) Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clinical Implant Dentistry & Related Research 2 : 85 92.
    • (2000) Clinical Implant Dentistry & Related Research , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 12
    • 0036854433 scopus 로고    scopus 로고
    • Evolution of the internal fixation of long bone fractures. the scientific basis of biological internal fixation: Choosing a new balance between stability and biology
    • Perren, S.M. (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. Journal ofBone and Joint Surgery (Br) 84 : 1093 1110.
    • (2002) Journal OfBone and Joint Surgery (Br) , vol.84 , pp. 1093-1110
    • Perren, S.M.1
  • 13
    • 24344488119 scopus 로고    scopus 로고
    • Bone healing: Histologic and physiologic concepts
    • In. Summer-Smith, G. ed. New York. Thieme, AO Publishing.
    • Rahn, B. (2002) Bone healing: histologic and physiologic concepts. In : Summer-Smith, G., ed. Bone in Clinical Orthopedics, 287 326. New York : Thieme, AO Publishing.
    • (2002) Bone in Clinical Orthopedics , pp. 287-326
    • Rahn, B.1
  • 15
    • 0033200642 scopus 로고    scopus 로고
    • Bone dynamics of osseointegration, ankylosis, and tooth movement
    • Roberts, W.E. (1999) Bone dynamics of osseointegration, ankylosis, and tooth movement. Journal of Indiana Dental Association 78 : 24 32.
    • (1999) Journal of Indiana Dental Association , vol.78 , pp. 24-32
    • Roberts, W.E.1
  • 16
    • 0026521288 scopus 로고
    • Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs
    • Soballe, K., Brockstedt-Rasmussen, H., Hansen, E.S. Bunger, C. (1992) Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studied in dogs. Acta Orthopedica Scandinava 63 : 128 140.
    • (1992) Acta Orthopedica Scandinava , vol.63 , pp. 128-140
    • Soballe, K.1    Brockstedt-Rasmussen, H.2    Hansen, E.S.3    Bunger, C.4
  • 18
    • 0034139407 scopus 로고    scopus 로고
    • Considerations preliminary to the application of early and immediate loading protocols in dental implantology
    • Szmukler-Moncler, S., Piattelli, A., Favero, G.A. Dubruille, J.H. (2000) Considerations preliminary to the application of early and immediate loading protocols in dental implantology. Clinical Oral Implants Research 11 : 12 25.
    • (2000) Clinical Oral Implants Research , vol.11 , pp. 12-25
    • Szmukler-Moncler, S.1    Piattelli, A.2    Favero, G.A.3    Dubruille, J.H.4
  • 20
    • 0033073260 scopus 로고    scopus 로고
    • Bone classification: Clinical-histomorphometric comparison
    • Trisi, P. Rao, W. (1999) Bone classification: clinical-histomorphometric comparison. Clinical Oral Implants Research 10 : 1 7.
    • (1999) Clinical Oral Implants Research , vol.10 , pp. 1-7
    • Trisi, P.1    Rao, W.2
  • 22
    • 0026298340 scopus 로고
    • Three-dimensional analyses of human bite-force magnitude and moment
    • van Eijden, T.M. (1991) Three-dimensional analyses of human bite-force magnitude and moment. Archives of Oral Biology 36 : 535 539.
    • (1991) Archives of Oral Biology , vol.36 , pp. 535-539
    • Van Eijden, T.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.