Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses

Author keywords

Hip prosthesis; Interface motion; Mechanical testing; Optical detectors; Three dimensional displacement transducer

Indexed keywords

BIOMECHANICS; BONE; IMPLANTS (SURGICAL); INTERFACES (MATERIALS); OPTICAL SENSORS; RELIABILITY; SILICON SENSORS; STRAIN; THERMISTORS;

EID: 0343052959     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(96)00060-4     Document Type: Article
Times cited : (53)

References (37)
  • 1
    • 0024430093 scopus 로고
    • The effect of stem fit on bone hypertrophy and pain relief in cemented total hip arthroplasty
    • Whiteside, L. A., The effect of stem fit on bone hypertrophy and pain relief in cemented total hip arthroplasty. Clinical Orthopaedics, 1989, 247, 138-147.
    • (1989) Clinical Orthopaedics , vol.247 , pp. 138-147
    • Whiteside, L.A.1
  • 4
    • 0028344842 scopus 로고
    • Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs
    • Hua, J. and Walker, P. S., Relative motion of hip stems under load. An in vitro study of symmetrical, asymmetrical, and custom asymmetrical designs. Journal of Bone and Joint Surgery, 1994, 76A, 95-103.
    • (1994) Journal of Bone and Joint Surgery , vol.76 A , pp. 95-103
    • Hua, J.1    Walker, P.S.2
  • 6
    • 0026131363 scopus 로고
    • Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur
    • McKellop, H., Ebramzadeh, E., Niederer, P. G. and Sarmiento, A., Comparison of the stability of press-fit hip prosthesis femoral stems using a synthetic model femur. Journal of Orthopaedic Research, 1991, 9, 297-305.
    • (1991) Journal of Orthopaedic Research , vol.9 , pp. 297-305
    • McKellop, H.1    Ebramzadeh, E.2    Niederer, P.G.3    Sarmiento, A.4
  • 8
    • 0021329367 scopus 로고
    • Instability, migration and laxity of total hip prostheses: A roentgen stereophotogrammatric study
    • Mjoberg, B., Hansson, L. I. and Selvik, G., Instability, migration and laxity of total hip prostheses: a roentgen stereophotogrammatric study. Acta Orthopaedica Scandinavica, 1984, 55, 141-145.
    • (1984) Acta Orthopaedica Scandinavica , vol.55 , pp. 141-145
    • Mjoberg, B.1    Hansson, L.I.2    Selvik, G.3
  • 9
    • 0026353010 scopus 로고
    • In vivo measurement of relative motion between an uncemented femoral total hip component and the femur by roentegen sterophotogrammetric analysis
    • Nistor, L., Blaha, J. D., Kjellström, U. and Selvik, G., In vivo measurement of relative motion between an uncemented femoral total hip component and the femur by roentegen sterophotogrammetric analysis. Clinical Orthopaedics, 1991, 269, 220-227.
    • (1991) Clinical Orthopaedics , vol.269 , pp. 220-227
    • Nistor, L.1    Blaha, J.D.2    Kjellström, U.3    Selvik, G.4
  • 10
  • 11
    • 0024498830 scopus 로고
    • The effect of collar and distal stem fixation on micromotion of femoral stem in uncemented total hip arthroplasty
    • Whiteside, L. A. and Easley, J. C., The effect of collar and distal stem fixation on micromotion of femoral stem in uncemented total hip arthroplasty. Clinical Orthopaedics, 1989, 239, 145-153.
    • (1989) Clinical Orthopaedics , vol.239 , pp. 145-153
    • Whiteside, L.A.1    Easley, J.C.2
  • 14
    • 0026457532 scopus 로고
    • Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses
    • Engh, C. A., O'Connor, D., Jasty, M., McGovern, T., Bobyn, J. D. and Harris, W. H., Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clinical Orthopaedics, 1982, 285, 13-29.
    • (1982) Clinical Orthopaedics , vol.285 , pp. 13-29
    • Engh, C.A.1    O'Connor, D.2    Jasty, M.3    McGovern, T.4    Bobyn, J.D.5    Harris, W.H.6
  • 15
    • 0024957650 scopus 로고
    • Examination of rotational fixation of the femoral component in total hip arthroplasty
    • Sugiyama, H., Witheside, L. A. and Kaiser, A. D., Examination of rotational fixation of the femoral component in total hip arthroplasty. Clinical Orthopaedics, 1989, 249, 122-128.
    • (1989) Clinical Orthopaedics , vol.249 , pp. 122-128
    • Sugiyama, H.1    Witheside, L.A.2    Kaiser, A.D.3
  • 16
    • 0027530299 scopus 로고
    • Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components
    • Whiteside, L. A., White, S. E., Engh, C. A. and Head, W., Mechanical evaluation of cadaver retrieval specimens of cementless bone-ingrown total hip arthroplasty femoral components. Journal of Arthroplasty, 1993, 8(2), 147-155.
    • (1993) Journal of Arthroplasty , vol.8 , Issue.2 , pp. 147-155
    • Whiteside, L.A.1    White, S.E.2    Engh, C.A.3    Head, W.4
  • 18
    • 0024463988 scopus 로고
    • Experimental method for the in vitro testing of the initial stability of cementless hip prostheses
    • Schneider, E., Eulenberger, J., Steiner, W., Wyder, D., Friedman, R. J. and Perren, S. M., Experimental method for the in vitro testing of the initial stability of cementless hip prostheses. Journal of Biomechanics, 1989, 22(6/7), 735-744.
    • (1989) Journal of Biomechanics , vol.22 , Issue.6-7 , pp. 735-744
    • Schneider, E.1    Eulenberger, J.2    Steiner, W.3    Wyder, D.4    Friedman, R.J.5    Perren, S.M.6
  • 19
    • 0026848841 scopus 로고
    • A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses
    • Gilbert, J. L., Bloomfeld, R. S., Lautenschlager, E. P. and Wixson, R. L., A computer-based biomechanical analysis of the three-dimensional motion of cementless hip prostheses. Journal of Biomechanics, 1992, 25(4), 329-340.
    • (1992) Journal of Biomechanics , vol.25 , Issue.4 , pp. 329-340
    • Gilbert, J.L.1    Bloomfeld, R.S.2    Lautenschlager, E.P.3    Wixson, R.L.4
  • 20
    • 0027669981 scopus 로고
    • Stem curvature and load angle influence the initial relative bone-implant motion of cementless femoral stems
    • Berzins, A., Summer, D. R., Andriacchi, T. P. and Galante, J. O., Stem curvature and load angle influence the initial relative bone-implant motion of cementless femoral stems. Journal of Orthopaedic Research, 1993, 11(5), 758-769.
    • (1993) Journal of Orthopaedic Research , vol.11 , Issue.5 , pp. 758-769
    • Berzins, A.1    Summer, D.R.2    Andriacchi, T.P.3    Galante, J.O.4
  • 21
    • 0026231958 scopus 로고
    • Non-contacted measurement of small translations and rotations in all degrees of freedom
    • Dürselen, L., Claes, L. and Wilke, H. J., Non-contacted measurement of small translations and rotations in all degrees of freedom. Biomed Technik, 1991, 36, 248-252.
    • (1991) Biomed Technik , vol.36 , pp. 248-252
    • Dürselen, L.1    Claes, L.2    Wilke, H.J.3
  • 22
    • 4243367100 scopus 로고
    • Biomechanische untersuchung zur primärstabilität der bicontact-revisionsprothese
    • eds S. Weller and R. Volkmann. Georg Thieme, Stuttgart
    • Blömer, W., Biomechanische untersuchung zur primärstabilität der bicontact-revisionsprothese. In Das Bicontact Hüftendoprothesen System, eds S. Weller and R. Volkmann. Georg Thieme, Stuttgart, 1994, pp. 147-160.
    • (1994) Das Bicontact Hüftendoprothesen System , pp. 147-160
    • Blömer, W.1
  • 23
  • 24
    • 0025653959 scopus 로고
    • The effect of the hollow-stem prosthesis on the distribution of stresses in cortical bone
    • Mattheck, C., Vorberg, U. and Kranz, C., The effect of the hollow-stem prosthesis on the distribution of stresses in cortical bone. Biomed Technik, 1990, 35, 316-319.
    • (1990) Biomed Technik , vol.35 , pp. 316-319
    • Mattheck, C.1    Vorberg, U.2    Kranz, C.3
  • 25
    • 0026863992 scopus 로고
    • Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty
    • Cheal, E. J., Spector, M. and Hayes, W. C., Role of loads and prosthesis material properties on the mechanics of the proximal femur after total hip arthroplasty. Journal of Orthopaedic Research, 1992, 10(3), 401-422.
    • (1992) Journal of Orthopaedic Research , vol.10 , Issue.3 , pp. 401-422
    • Cheal, E.J.1    Spector, M.2    Hayes, W.C.3
  • 27
    • 0024840370 scopus 로고
    • In vitro analysis of proximal femoral strains using pea femoral implants and a hip abductor muscle simulator
    • Finlay, J. B., Rorabeck, C. H., Bourne, R. B. and Tew, W. M., In vitro analysis of proximal femoral strains using pea femoral implants and a hip abductor muscle simulator. Journal of Arthroplasty, 1989, 4(4), 335-345.
    • (1989) Journal of Arthroplasty , vol.4 , Issue.4 , pp. 335-345
    • Finlay, J.B.1    Rorabeck, C.H.2    Bourne, R.B.3    Tew, W.M.4
  • 29
    • 0025968284 scopus 로고
    • The effect of defect size on the stress concentration and fracture characteristics for a tubular torsional model with a transverse hole
    • Kuo, R. F., Chao, E. Y. S., Rim, K. and Park, J. B., The effect of defect size on the stress concentration and fracture characteristics for a tubular torsional model with a transverse hole. Journal of Biomechanics, 1991, 24(2), 147-155.
    • (1991) Journal of Biomechanics , vol.24 , Issue.2 , pp. 147-155
    • Kuo, R.F.1    Chao, E.Y.S.2    Rim, K.3    Park, J.B.4
  • 30
    • 0016936798 scopus 로고
    • Lateral-effect photodiodes
    • Kelly, B. O., Lateral-effect photodiodes. Laser Focus Magazine, 1976, 3, 38-44.
    • (1976) Laser Focus Magazine , vol.3 , pp. 38-44
    • Kelly, B.O.1
  • 31
    • 0017983222 scopus 로고
    • Position sensitive light detectors with high linearity
    • Petersson, G. P. and Lindholm, L. E., Position sensitive light detectors with high linearity. IEEE Journal of Solid State Circuits, 1978, SC-13(3), 392-399.
    • (1978) IEEE Journal of Solid State Circuits , vol.SC-13 , Issue.3 , pp. 392-399
    • Petersson, G.P.1    Lindholm, L.E.2
  • 34
    • 0016871395 scopus 로고
    • Practical electro-optic deflection measurements system
    • Hutcheson, L. D., Practical electro-optic deflection measurements system. Optical Engineering, 1976, 15(1), 61-63.
    • (1976) Optical Engineering , vol.15 , Issue.1 , pp. 61-63
    • Hutcheson, L.D.1
  • 35
    • 0342617447 scopus 로고
    • Siemens Matsushita Components
    • Siemens Matsushita Components, Handbook Thermistoren, 1994, pp. 198-201.
    • (1994) Handbook Thermistoren , pp. 198-201
  • 36
    • 0027641060 scopus 로고
    • Hip joint loading during walking and running, measured in two patients
    • Bergmann, G., Graichen, F. and Rohlmann, A., Hip joint loading during walking and running, measured in two patients. Journal of Biomechanics, 1993, 26(8), 969-990.
    • (1993) Journal of Biomechanics , vol.26 , Issue.8 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.