In vitro evaluation of bacterial leakage along the implant-abutment interface of different implant systems

Author keywords

Abutments; Bacterial leakage; Chewing simulation; Dental implants

Indexed keywords

ARTICLE; COMPARATIVE STUDY; DENTURE; ESCHERICHIA COLI; ISOLATION AND PURIFICATION; MASTICATION; MICROBIOLOGY; NONPARAMETRIC TEST; TOOTH DISEASE; TOOTH IMPLANTATION; WEIGHT BEARING;

EID: 30844432439     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (212)

References (16)
  • 1
    • 0037364681 scopus 로고    scopus 로고
    • Persistent acute inflammation at the implant-abutment interface
    • Broggini N, McManus LM, Hermann JS, et al. Persistent acute inflammation at the implant-abutment interface. J Dent Res 2003;82:232-237.
    • (2003) J Dent Res , vol.82 , pp. 232-237
    • Broggini, N.1    McManus, L.M.2    Hermann, J.S.3
  • 2
    • 0019663098 scopus 로고
    • A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
    • Adell R, Lekholm U, Rockler B, Brånemark P-I. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg 1981;10:387-416.
    • (1981) Int J Oral Surg , vol.10 , pp. 387-416
    • Adell, R.1    Lekholm, U.2    Rockler, B.3    Brånemark, P.-I.4
  • 3
    • 0038838352 scopus 로고
    • Fluid and microbial leakage of implant-abutment assembly in vitro
    • Traversy MC, Birek P. Fluid and microbial leakage of implant-abutment assembly in vitro [abstract]. J Dent Res 1992;71:754.
    • (1992) J Dent Res , vol.71 , pp. 754
    • Traversy, M.C.1    Birek, P.2
  • 4
    • 0027654684 scopus 로고
    • Bacterial colonization of the internal part of two-stage implants. An in vivo study
    • Quirynen M, van Steenberghe D. Bacterial colonization of the internal part of two-stage implants. An in vivo study. Clin Oral Implants Res 1993;4:158-161.
    • (1993) Clin Oral Implants Res , vol.4 , pp. 158-161
    • Quirynen, M.1    Van Steenberghe, D.2
  • 5
    • 0028701189 scopus 로고
    • Microbial penetration along the implant components of the Brånemark system. An in vitro study
    • Quirynen M, Bollen CM, Eyssen H, van Steenberghe D. Microbial penetration along the implant components of the Brånemark system. An in vitro study. Clin Oral Implants Res 1994;5:239-244.
    • (1994) Clin Oral Implants Res , vol.5 , pp. 239-244
    • Quirynen, M.1    Bollen, C.M.2    Eyssen, H.3    Van Steenberghe, D.4
  • 6
    • 0348149943 scopus 로고
    • Mikroben in subgingivalen Implantatspalträumen
    • Wahl G, Schaal KP. Mikroben in subgingivalen Implantatspalträumen. Z Zahnärztl Implantol 1989;5:287-291.
    • (1989) Z Zahnärztl Implantol , vol.5 , pp. 287-291
    • Wahl, G.1    Schaal, K.P.2
  • 10
    • 0027017667 scopus 로고
    • The microbial colonization of implant elements made of plastics and titanium
    • Wahl G, Muller F, Schaal KP. The microbial colonization of implant elements made of plastics and titanium. Schweiz Monatsschr Zahnmed 1992;102:1321-1326.
    • (1992) Schweiz Monatsschr Zahnmed , vol.102 , pp. 1321-1326
    • Wahl, G.1    Muller, F.2    Schaal, K.P.3
  • 11
    • 0033196816 scopus 로고    scopus 로고
    • Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro
    • Besimo CE, Guindy JS, Lewetag D, Meyer J. Prevention of bacterial leakage into and from prefabricated screw-retained crowns on implants in vitro. Int J Oral Maxillofac Implants 1999;14:654-660.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 654-660
    • Besimo, C.E.1    Guindy, J.S.2    Lewetag, D.3    Meyer, J.4
  • 12
    • 0029377916 scopus 로고
    • Comparison of screw loosening, rotation, and deflection among three implant designs
    • Dixon DL, Breeding LC, Sadler JP, McKay ML.Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent 1995;74:270-278.
    • (1995) J Prosthet Dent , vol.74 , pp. 270-278
    • Dixon, D.L.1    Breeding, L.C.2    Sadler, J.P.3    McKay, M.L.4
  • 13
    • 0030098964 scopus 로고    scopus 로고
    • The effect of implant/abutment hexagonal misfit on screw joint stability
    • Binon PP. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 1996;9:149-160.
    • (1996) Int J Prosthodont , vol.9 , pp. 149-160
    • Binon, P.P.1
  • 14
    • 0032617145 scopus 로고    scopus 로고
    • Microleakage at the abutment-implant interface of osseointegrated implants: A comparative study
    • Gross M, Abramovich I, Weiss EI. Microleakage at the abutment-implant interface of osseointegrated implants: A comparative study. Int J Oral Maxillofac Implants 1999;14:94-100.
    • (1999) Int J Oral Maxillofac Implants , vol.14 , pp. 94-100
    • Gross, M.1    Abramovich, I.2    Weiss, E.I.3
  • 15
    • 0029688591 scopus 로고    scopus 로고
    • Marginal fit of prefabricated crowns of the Ha-Ti implant system: An in vitro scanning electron microscopic study
    • Besimo D, Bodenschatz V, Guggenheim R, Hassell T. Marginal fit of prefabricated crowns of the Ha-Ti implant system: An in vitro scanning electron microscopic study. Int J Prosthodont 1996;9:87-94.
    • (1996) Int J Prosthodont , vol.9 , pp. 87-94
    • Besimo, D.1    Bodenschatz, V.2    Guggenheim, R.3    Hassell, T.4
  • 16
    • 0026167259 scopus 로고
    • Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study
    • Rangert B, Gunne J, Sullivan DY. Mechanical aspects of a Brånemark implant connected to a natural tooth: An in vitro study. Int J Oral Maxillofac Implants 1991;6:177-186.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 177-186
    • Rangert, B.1    Gunne, J.2    Sullivan, D.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.