메뉴 건너뛰기




Volumn 42, Issue 6, 2011, Pages 471-478

Effect of geometric parameters on finite element analysis of bone loading caused by nonpassively fitting implant-supported dental restorations

Author keywords

Bone loading; Finite element analysis; Implant supported restoration; Model geometry; Passive fit; Von Mises equivalent stress

Indexed keywords

TOOTH CEMENT;

EID: 80053079936     PISSN: 00336572     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (7)

References (35)
  • 1
    • 33845506823 scopus 로고    scopus 로고
    • Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification
    • Al-Sukhun J, Kelleway J, Helenius M. Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. I. Mathematical validation and experimental verification. J Biomed Mater Res A 2007;80:234-246.
    • (2007) J Biomed Mater Res A , vol.80 , pp. 234-246
    • Al-Sukhun, J.1    Kelleway, J.2    Helenius, M.3
  • 2
    • 0036348012 scopus 로고    scopus 로고
    • Statistical methods in finite element analysis
    • Dar FH, Meakin JR, Aspden RM. Statistical methods in finite element analysis. J Biomech 2002;35:1155-1161.
    • (2002) J Biomech , vol.35 , pp. 1155-1161
    • Dar, F.H.1    Meakin, J.R.2    Aspden, R.M.3
  • 3
    • 0030893518 scopus 로고    scopus 로고
    • Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis
    • Korioth TW, Versluis A. Modeling the mechanical behavior of the jaws and their related structures by finite element (FE) analysis. Crit Rev Oral Biol Med 1997;8:90-104.
    • (1997) Crit Rev Oral Biol Med , vol.8 , pp. 90-104
    • Korioth, T.W.1    Versluis, A.2
  • 4
    • 0033111586 scopus 로고    scopus 로고
    • The effectiveness of element downsizing on a three-dimensional finite element model of bone trabeculae in implant biomechanics
    • Sato Y, Wadamoto M, Tsuga K, Teixeira ER. The effectiveness of element downsizing on a three-dimensional finite element model of bone trabeculae in implant biomechanics. J Oral Rehabil 1999;26:288-291.
    • (1999) J Oral Rehabil , vol.26 , pp. 288-291
    • Sato, Y.1    Wadamoto, M.2    Tsuga, K.3    Teixeira, E.R.4
  • 5
    • 33845488700 scopus 로고    scopus 로고
    • Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. II. Variables affecting the predictive behavior of a finite element model of a human mandible
    • Al-Sukhun J, Lindqvist C, Helenius M. Development of a three-dimensional finite element model of a human mandible containing endosseous dental implants. II. Variables affecting the predictive behavior of a finite element model of a human mandible. J Biomed Mater Res A 2007;80:247-256.
    • (2007) J Biomed Mater Res A , vol.80 , pp. 247-256
    • Al-Sukhun, J.1    Lindqvist, C.2    Helenius, M.3
  • 7
    • 35748966394 scopus 로고    scopus 로고
    • Influence of anisotropy on peri-implant stress and strain in complete mandible model from CT
    • Liao SH, Tong RF, Dong JX. Influence of anisotropy on peri-implant stress and strain in complete mandible model from CT. Comput Med Imaging Graph 2008;32:53-60.
    • (2008) Comput Med Imaging Graph , vol.32 , pp. 53-60
    • Liao, S.H.1    Tong, R.F.2    Dong, J.X.3
  • 8
    • 64649084225 scopus 로고    scopus 로고
    • Three-dimensional finite element modeling from CT images of tooth and its validation
    • Tajima K, Chen KK, Takahashi N, Noda N, Nagamatsu Y, Kakigawa H. Three-dimensional finite element modeling from CT images of tooth and its validation. Dent Mater J 2009;28:219-226.
    • (2009) Dent Mater J , vol.28 , pp. 219-226
    • Tajima, K.1    Chen, K.K.2    Takahashi, N.3    Noda, N.4    Nagamatsu, Y.5    Kakigawa, H.6
  • 10
    • 0035377329 scopus 로고    scopus 로고
    • Application of finite element analysis in implant dentistry: A review of the literature
    • Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: A review of the literature. J Prosthet Dent 2001;85:585-598.
    • (2001) J Prosthet Dent , vol.85 , pp. 585-598
    • Geng, J.P.1    Tan, K.B.2    Liu, G.R.3
  • 11
    • 43249109361 scopus 로고    scopus 로고
    • A finite element analysis of two different dental implants: Stress distribution in the prosthesis, abutment, implant, and supporting bone
    • Quaresma SE, Cury PR, Sendyk WR, Sendyk C. A finite element analysis of two different dental implants: Stress distribution in the prosthesis, abutment, implant, and supporting bone. J Oral Implantol 2008;34:1-6.
    • (2008) J Oral Implantol , vol.34 , pp. 1-6
    • Quaresma, S.E.1    Cury, P.R.2    Sendyk, W.R.3    Sendyk, C.4
  • 12
    • 0041418181 scopus 로고    scopus 로고
    • Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis
    • Tada S, Stegaroiu R, Kitamura E, Miyakawa O, Kusakari H. Influence of implant design and bone quality on stress/strain distribution in bone around implants: A 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2003;18:357-368.
    • (2003) Int J Oral Maxillofac Implants , vol.18 , pp. 357-368
    • Tada, S.1    Stegaroiu, R.2    Kitamura, E.3    Miyakawa, O.4    Kusakari, H.5
  • 14
    • 38549172805 scopus 로고    scopus 로고
    • Step-wise analysis of the dental implant insertion process using the finite element technique
    • van Staden RC, Guan H, Johnson NW, Loo YC, Meredith N. Step-wise analysis of the dental implant insertion process using the finite element technique. Clin Oral Implants Res 2008;19:303-313.
    • (2008) Clin Oral Implants Res , vol.19 , pp. 303-313
    • van Staden, R.C.1    Guan, H.2    Johnson, N.W.3    Loo, Y.C.4    Meredith, N.5
  • 16
    • 58449083652 scopus 로고    scopus 로고
    • Finite element analysis of stress in bone adjacent to dental implants
    • Rubo JH, Souza EA. Finite element analysis of stress in bone adjacent to dental implants. J Oral Implantol 2008;34:248-255.
    • (2008) J Oral Implantol , vol.34 , pp. 248-255
    • Rubo, J.H.1    Souza, E.A.2
  • 17
    • 44949237047 scopus 로고    scopus 로고
    • Effect of framework shape on the fracture strength of implant-supported all-ceramic fixed partial dentures in the molar region
    • Tsumita M, Kokubo Y, Vult von Steyern P, Fukushima S. Effect of framework shape on the fracture strength of implant-supported all-ceramic fixed partial dentures in the molar region. J Prosthodont 2008;17:274-285.
    • (2008) J Prosthodont , vol.17 , pp. 274-285
    • Tsumita, M.1    Kokubo, Y.2    Vult Von Steyern, P.3    Fukushima, S.4
  • 18
    • 14844290222 scopus 로고    scopus 로고
    • Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown
    • Sevimay M, Turhan F, Kiliçarslan MA, Eskitascioglu G. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. J Prosthet Dent 2005;93:227-234.
    • (2005) J Prosthet Dent , vol.93 , pp. 227-234
    • Sevimay, M.1    Turhan, F.2    Kiliçarslan, M.A.3    Eskitascioglu, G.4
  • 19
    • 0030322971 scopus 로고    scopus 로고
    • The experimental verification of the efficacy of finite element modeling to dental implant systems
    • Baiamonte T, Abbate MF, Pizzarello F, Lozada J, James R. The experimental verification of the efficacy of finite element modeling to dental implant systems. J Oral Implantol 1996;22:104-110.
    • (1996) J Oral Implantol , vol.22 , pp. 104-110
    • Baiamonte, T.1    Abbate, M.F.2    Pizzarello, F.3    Lozada, J.4    James, R.5
  • 20
    • 34548548244 scopus 로고    scopus 로고
    • Comparison of implant body designs and threaded designs of dental implants: A 3-dimensional finite element analysis
    • Huang HL, Chang CH, Hsu JT, Fallgatter AM, Ko CC. Comparison of implant body designs and threaded designs of dental implants: A 3-dimensional finite element analysis. Int J Oral Maxillofac Implants 2007;22:551-562.
    • (2007) Int J Oral Maxillofac Implants , vol.22 , pp. 551-562
    • Huang, H.L.1    Chang, C.H.2    Hsu, J.T.3    Fallgatter, A.M.4    Ko, C.C.5
  • 21
    • 0036592503 scopus 로고    scopus 로고
    • Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models
    • Nagasao T, Kobayashi M, Tsuchiya Y, Kaneko T, Nakajima T. Finite element analysis of the stresses around endosseous implants in various reconstructed mandibular models. J Craniomaxillofac Surg 2002;30:170-177.
    • (2002) J Craniomaxillofac Surg , vol.30 , pp. 170-177
    • Nagasao, T.1    Kobayashi, M.2    Tsuchiya, Y.3    Kaneko, T.4    Nakajima, T.5
  • 22
    • 41549111389 scopus 로고    scopus 로고
    • Predictions of bone remodeling around dental implant systems
    • Chou HY, Jagodnik JJ, Müftü S. Predictions of bone remodeling around dental implant systems. J Biomech 2008;41:1365-1373.
    • (2008) J Biomech , vol.41 , pp. 1365-1373
    • Chou, H.Y.1    Jagodnik, J.J.2    Müftü, S.3
  • 23
    • 77954862317 scopus 로고    scopus 로고
    • The effect of thread design on stress distribution in a solid screw implant:A 3D finite element analysis
    • Eraslan O, Inan O. The effect of thread design on stress distribution in a solid screw implant:A 3D finite element analysis. Clin Oral Investig 2010;14:411-416.
    • (2010) Clin Oral Investig , vol.14 , pp. 411-416
    • Eraslan, O.1    Inan, O.2
  • 24
    • 0036514370 scopus 로고    scopus 로고
    • Finite element analysis on dental implant-supported prostheses without passive fit
    • Kunavisarut C, Lang LA, Stoner BR, Felton DA. Finite element analysis on dental implant-supported prostheses without passive fit. J Prosthodont 2002;11:30-40.
    • (2002) J Prosthodont , vol.11 , pp. 30-40
    • Kunavisarut, C.1    Lang, L.A.2    Stoner, B.R.3    Felton, D.A.4
  • 25
    • 33644854187 scopus 로고    scopus 로고
    • Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis
    • Natali AN, Pavan PG, Ruggero AL. Evaluation of stress induced in peri-implant bone tissue by misfit in multi-implant prosthesis. Dent Mater 2006;22:388-395.
    • (2006) Dent Mater , vol.22 , pp. 388-395
    • Natali, A.N.1    Pavan, P.G.2    Ruggero, A.L.3
  • 26
    • 39149119937 scopus 로고    scopus 로고
    • Investigation of bone inelastic response in interaction phenomena with dental implants
    • Natali AN, Carniel EL, Pavan PG. Investigation of bone inelastic response in interaction phenomena with dental implants. Dent Mater 2008;24:561-569.
    • (2008) Dent Mater , vol.24 , pp. 561-569
    • Natali, A.N.1    Carniel, E.L.2    Pavan, P.G.3
  • 27
    • 77952831265 scopus 로고    scopus 로고
    • Effect of superstructure materials and misfit on stress distribution in a single implant-supported prosthesis: A finite element analysis
    • Assunção WG, Gomes EA, Barão VA, Delben JA, Tabata LF, de Sousa EA. Effect of superstructure materials and misfit on stress distribution in a single implant-supported prosthesis: A finite element analysis. J Craniofac Surg 2010;21:689-695.
    • (2010) J Craniofac Surg , vol.21 , pp. 689-695
    • Assunção, W.G.1    Gomes, E.A.2    Barão, V.A.3    Delben, J.A.4    Tabata, L.F.5    de Sousa, E.A.6
  • 29
    • 2942635731 scopus 로고    scopus 로고
    • Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data
    • Mellal A, Wiskott HW, Botsis J, Scherrer SS, Belser UC. Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data. Clin Oral Implants Res 2004;15:239-248.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 239-248
    • Mellal, A.1    Wiskott, H.W.2    Botsis, J.3    Scherrer, S.S.4    Belser, U.C.5
  • 30
    • 84991043040 scopus 로고    scopus 로고
    • Bone loading due to different misfit types in implant-supported fixed dental prostheses: A 3D-finite element analysis based on experimental results
    • press
    • Winter W, Möhrle S, Holst S, Karl M. Bone loading due to different misfit types in implant-supported fixed dental prostheses: A 3D-finite element analysis based on experimental results. Int J Oral Maxillofac Implants (in press).
    • Int J Oral Maxillofac Implants
    • Winter, W.1    Möhrle, S.2    Holst, S.3    Karl, M.4
  • 31
    • 0038030632 scopus 로고    scopus 로고
    • Prevention of mesh-dependent damage growth in finite element simulations of crack formation in acrylic bone cement
    • Stolk J, Verdonschot N, Mann KA, Huiskes R. Prevention of mesh-dependent damage growth in finite element simulations of crack formation in acrylic bone cement. J Biomech 2003;36:861-871.
    • (2003) J Biomech , vol.36 , pp. 861-871
    • Stolk, J.1    Verdonschot, N.2    Mann, K.A.3    Huiskes, R.4
  • 32
    • 72449209142 scopus 로고    scopus 로고
    • Numerical simulation of the effect of time-to-loading on peri-implant bone
    • Akça K, Eser A, Canay S. Numerical simulation of the effect of time-to-loading on peri-implant bone. Med Eng Phys 2010;32:7-13.
    • (2010) Med Eng Phys , vol.32 , pp. 7-13
    • Akça, K.1    Eser, A.2    Canay, S.3
  • 33
    • 77955909209 scopus 로고    scopus 로고
    • Parameters of implant stability measurements based on resonance frequency and damping capacity: A comparative finite element analysis
    • Winter W, Möhrle S, Holst S, Karl M. Parameters of implant stability measurements based on resonance frequency and damping capacity: A comparative finite element analysis. Int J Oral Maxillofac Implants 2010;25:532-539.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 532-539
    • Winter, W.1    Möhrle, S.2    Holst, S.3    Karl, M.4
  • 34
    • 0036528280 scopus 로고    scopus 로고
    • A comparative analysis based on different strength criteria for evaluation of risk factor for dental implants
    • Natali AN, Pavan PG. A comparative analysis based on different strength criteria for evaluation of risk factor for dental implants. Comput Methods Biomech Biomed Engin 2002;5:127-133.
    • (2002) Comput Methods Biomech Biomed Engin , vol.5 , pp. 127-133
    • Natali, A.N.1    Pavan, P.G.2
  • 35
    • 70349575393 scopus 로고    scopus 로고
    • Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants
    • Eser A, Akça K, Eckert S, Cehreli MC. Nonlinear finite element analysis versus ex vivo strain gauge measurements on immediately loaded implants. Int J Oral Maxillofac Implants 2009;24:439-446.
    • (2009) Int J Oral Maxillofac Implants , vol.24 , pp. 439-446
    • Eser, A.1    Akça, K.2    Eckert, S.3    Cehreli, M.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.