Volumn 60, Issue 7, 2013, Pages 2776-2798

Overview of control systems for the operation of DFIGs in wind energy applications

Author keywords

Control strategies; crowbar; doubly fed induction generator (DFIG); low voltage ride through (LVRT); reactive support; robust controller; voltage unbalance; wind turbine

Indexed keywords

ASYNCHRONOUS GENERATORS; CONTROL SYSTEMS; ELECTRIC FAULT CURRENTS; WIND TURBINES;

EID: 84874831311     PISSN: 02780046     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIE.2013.2243372     Document Type: Article
Times cited : (656)

References (228)
  • 4
    • 84874924775 scopus 로고    scopus 로고
    • Accessed on May. [Online]
    • Web site "The wind Power Net," Accessed on May 2012. [Online]. Available: http://www.thewindpower.net
    • (2012) The Wind Power Net
    • Site, W.1
  • 6
    • 61649120073 scopus 로고    scopus 로고
    • Optimization of multibrid permanentmagnet wind generator systems
    • Mar
    • H. Li, Z. Chen, and H. Polinder, "Optimization of multibrid permanentmagnet wind generator systems," IEEE Trans. Energy Convers., vol. 24, no. 1, pp. 82-92, Mar. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.1 , pp. 82-92
    • Li, H.1    Chen, Z.2    Polinder, H.3
  • 7
    • 33947414834 scopus 로고    scopus 로고
    • Comparison of direct-drive and geared generator concepts for wind turbines
    • DOI 10.1109/TEC.2006.875476
    • H. Polinder, F. F. A. van der Pijl, G.-J. de Vilder, and P. J. Tavner, "Comparison of direct-drive and geared generator concepts for wind turbines," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 725-733, Sep. 2006. (Pubitemid 46445161)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 725-733
    • Polinder, H.1    Van Der Pijl, F.F.A.2    De Vilder, G.-J.3    Tavner, P.J.4
  • 9
    • 84874824740 scopus 로고    scopus 로고
    • ENERCON wind energy converters Technology & Service, Aurich, Germany. [Online]
    • Enercon. (2010). ENERCON wind energy converters Technology & Service, Aurich, Germany. [Online]. Available: http://www.enercon.de/p/downloads/EN-Eng- TandS-0710.pdf
    • (2010) Enercon
  • 10
    • 84857409011 scopus 로고    scopus 로고
    • Analytical and multiphysics approach to the optimal design of a 10-MW DFIG for directdrive wind turbines
    • Jul
    • V. Delli Colli, F. Marignetti, and C. Attaianese, "Analytical and multiphysics approach to the optimal design of a 10-MW DFIG for directdrive wind turbines," IEEE Trans. Ind. Electron., vol. 59, no. 7, pp. 2791-2799, Jul. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.7 , pp. 2791-2799
    • Delli Colli, V.1    Marignetti, F.2    Attaianese, C.3
  • 11
    • 85008522382 scopus 로고    scopus 로고
    • Input-output feedback linearization and speed control of a surface permanent-magnet synchronous wind generator with the boost-chopper converter
    • Sep
    • C. Xia, Q. Geng, X. Gu, T. Shi, and Z. Song, "Input-output feedback linearization and speed control of a surface permanent-magnet synchronous wind generator with the boost-chopper converter," IEEE Trans. Ind. Electron., vol. 59, no. 9, pp. 3489-3500, Sep. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.9 , pp. 3489-3500
    • Xia, C.1    Geng, Q.2    Gu, X.3    Shi, T.4    Song, Z.5
  • 12
    • 84868110719 scopus 로고    scopus 로고
    • Wind turbine generation system with optimized DC-link design and control
    • Mar
    • J. M. Espi and J. Castello, "Wind turbine generation system with optimized DC-link design and control," IEEE Trans. Ind. Electron., vol. 60, no. 3, pp. 919-929, Mar. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.3 , pp. 919-929
    • Espi, J.M.1    Castello, J.2
  • 13
    • 84874903936 scopus 로고    scopus 로고
    • Vestas. [Online]
    • Vestas, Last Accesed on Sep. 2012. [Online]. Available: http://www.vestas.com/en/wind-power-plants/procurement/turbine-overview.aspx#/ vestas-univers
    • (2012) Last Accesed on Sep.
  • 14
    • 84874924411 scopus 로고    scopus 로고
    • Last Accessed on September. [Online]
    • Clipper, Last Accessed on September 2012. [Online]. Available: http://www.clipperwind.com/productline.html
    • (2012) Clipper
  • 15
    • 0030146394 scopus 로고    scopus 로고
    • Doubly fed induction generator using back-to-back PWM converters and its application to variablespeed wind-energy generation
    • R. Pena, J. C. Clare, and G. M. Asher, "Doubly fed induction generator using back-to-backPWMconverters and its application to variable-speed wind-energy generation," Proc. Inst. Elect. Eng.-Elect. Power Appl., vol. 143, no. 3, pp. 231-241, May 1996. (Pubitemid 126760209)
    • (1996) IEE Proceedings: Electric Power Applications , vol.143 , Issue.3 , pp. 231-241
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 16
    • 0030234060 scopus 로고    scopus 로고
    • A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine
    • R. Pena, J. C. Clare, and G. M. Asher, "A doubly fed induction generator using back-to-back PWM converters supplying an isolated load from a variable speed wind turbine," Proc. Inst. Elect. Eng.-Elect. Power Appl., vol. 143, no. 5, pp. 380-387, Sep. 1996. (Pubitemid 126760218)
    • (1996) IEE Proceedings: Electric Power Applications , vol.143 , Issue.5 , pp. 380-387
    • Pena, R.1    Clare, J.C.2    Asher, G.M.3
  • 17
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • DOI 10.1109/2943.999610
    • S. Muller, M. Deicke, and R. W. De Doncker, "Doubly fed induction generator systems for wind turbines," IEEE Ind. Appl.Mag., vol. 8, no. 3, pp. 26-33, May/Jun. 2002. (Pubitemid 34630524)
    • (2002) IEEE Industry Applications Magazine , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3
  • 18
    • 63149196644 scopus 로고    scopus 로고
    • The brushless doubly-fed machine vector model in the rotor flux oriented reference frame
    • F. Barati, H. Oraee, E. Abdi, S. Shao, and R. McMahon, "The brushless doubly-fed machine vector model in the rotor flux oriented reference frame," in Proc. 34th Annu. IEEE IECON, 2008, pp. 1415-1420.
    • (2008) Proc. 34th Annu. IEEE IECON , pp. 1415-1420
    • Barati, F.1    Oraee, H.2    Abdi, E.3    Shao, S.4    McMahon, R.5
  • 19
    • 0029183383 scopus 로고
    • Performance capability analysis of the brushless doubly-fed machine as a wind generator
    • M. Boger and A.Wallace, "Performance capability analysis of the brushless doubly-fed machine as a wind generator," in Proc. 7th Int. Conf. Elect. Mach. Drives (Conf. Publ. No. 412), 1995, pp. 458-461.
    • (1995) Proc. 7th Int. Conf. Elect. Mach. Drives (Conf. Publ. 412) , pp. 458-461
    • Boger, M.1    Wallace, A.2
  • 20
    • 78650090052 scopus 로고    scopus 로고
    • Design and control of a high-efficiency Doubly-Fed Brushless machine for wind power generator application
    • L. Xu, B. Guan, H. Liu, L. Gao, and K. Tsai, "Design and control of a high-efficiency Doubly-Fed Brushless machine for wind power generator application," in Proc. IEEE ECCE, 2010, pp. 2409-2416.
    • (2010) Proc. IEEE ECCE , pp. 2409-2416
    • Xu, L.1    Guan, B.2    Liu, H.3    Gao, L.4    Tsai, K.5
  • 21
    • 84868110625 scopus 로고    scopus 로고
    • Analysis and enhancement of low-voltage ride-through capability of brushless doubly fed induction generator
    • Mar
    • S. Tohidi, H. Oraee, M. R. Zolghadri, S. Shao, and P. Tavner, "Analysis and enhancement of low-voltage ride-through capability of brushless doubly fed induction generator," IEEE Trans. Ind. Electron., vol. 60, no. 3, pp. 1146-1155, Mar. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.3 , pp. 1146-1155
    • Tohidi, S.1    Oraee, H.2    Zolghadri, M.R.3    Shao, S.4    Tavner, P.5
  • 22
    • 84857429250 scopus 로고    scopus 로고
    • Analysis and test results of a brushless doubly fed induction machine with rotary transformer
    • Jun
    • M. Ruviaro, F. Runcos, N. Sadowski, and I. M. Borges, "Analysis and test results of a brushless doubly fed induction machine with rotary transformer," IEEE Trans. Ind. Electron., vol. 59, no. 6, pp. 2670-2677, Jun. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.6 , pp. 2670-2677
    • Ruviaro, M.1    Runcos, F.2    Sadowski, N.3    Borges, I.M.4
  • 23
    • 79960029011 scopus 로고    scopus 로고
    • A critical review on the grid integration issues of DFIG based wind farms
    • H. T. Jadhav and R. Roy, "A critical review on the grid integration issues of DFIG based wind farms," in Proc. 10th Int. Conf. Environ. Elect. Eng., 2011, pp. 1-4.
    • (2011) Proc. 10th Int. Conf. Environ. Elect. Eng. , pp. 1-4
    • Jadhav, H.T.1    Roy, R.2
  • 25
    • 84860894267 scopus 로고    scopus 로고
    • Comparison of power fluctuation between OptiSlip and DFIG controlled wind turbines
    • M. S. Marhaba, S. Farhangi, and M. A. Paymani, "Comparison of power fluctuation between OptiSlip and DFIG controlled wind turbines," in Proc. 3rd PEDSTC, 2012, pp. 290-295.
    • (2012) Proc. 3rd PEDSTC , pp. 290-295
    • Marhaba, M.S.1    Farhangi, S.2    Paymani, M.A.3
  • 26
    • 77951465407 scopus 로고    scopus 로고
    • Comparison of reactive power compensation strategy of wind farm based on OptiSlip wind turbines
    • L. Lin, F. Sun, Y. Yang, and Q. Li, "Comparison of reactive power compensation strategy of wind farm based on OptiSlip wind turbines," in Proc. Int. Conf. SUPERGEN Supply, 2009, pp. 1-6.
    • (2009) Proc. Int. Conf. SUPERGEN Supply , pp. 1-6
    • Lin, L.1    Sun, F.2    Yang, Y.3    Li, Q.4
  • 27
    • 56649109819 scopus 로고    scopus 로고
    • Comparison between OptiSlip and fixed speed wind energy conversion systems
    • M. R. Khadraoui and M. Elleuch, "Comparison between OptiSlip and fixed speed wind energy conversion systems," in Proc. 5th Int. Multi- Conf. SSD, 2008, pp. 1-6.
    • (2008) Proc. 5th Int. Multi-Conf. SSD , pp. 1-6
    • Khadraoui, M.R.1    Elleuch, M.2
  • 29
    • 77249175320 scopus 로고    scopus 로고
    • Direct power control of doubly-fed-induction-generator-based wind turbines under unbalanced grid voltage
    • Feb
    • G. Abad, M. A. Rodriguez, G. Iwanski, and J. Poza, "Direct power control of doubly-fed-induction-generator-based wind turbines under unbalanced grid voltage," IEEE Trans. Power Electron., vol. 25, no. 2, pp. 442-452, Feb. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.2 , pp. 442-452
    • Abad, G.1    Rodriguez, M.A.2    Iwanski, G.3    Poza, J.4
  • 30
    • 0036223151 scopus 로고    scopus 로고
    • Control and performance of a doubly-fed induction machine intended for a flywheel energy storage system
    • DOI 10.1109/63.988676, PII S0885899302021646
    • H. Akagi and H. Sato, "Control and performance of a doubly-fed induction machine intended for a flywheel energy storage system," IEEE Trans. Power Electron., vol. 17, no. 1, pp. 109-116, Jan. 2002. (Pubitemid 34307398)
    • (2002) IEEE Transactions on Power Electronics , vol.17 , Issue.1 , pp. 109-116
    • Akagi, H.1    Sato, H.2
  • 31
    • 70349625590 scopus 로고    scopus 로고
    • Direct virtual torque control for doubly fed induction generator grid connection
    • Oct
    • J. Arbi, M. J.-B. Ghorbal, I. Slama-Belkhodja, and L. Charaabi, "Direct virtual torque control for doubly fed induction generator grid connection," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4163-4173, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4163-4173
    • Arbi, J.1    Ghorbal, M.J.-B.2    Slama-Belkhodja, I.3    Charaabi, L.4
  • 32
    • 0026916448 scopus 로고
    • Double-output induction generator operating at subsynchronous and supersynchronous speeds: Steady-state performance optimisation and wind-energy recovery
    • I. Cadirci and M. Ermis, "Double-output induction generator operating at subsynchronous and supersynchronous speeds: Steady-state performance optimisation and wind-energy recovery," Proc. Inst. Elect. Eng.-Elect. Power Appl., vol. 139, no. 5, pp. 429-442, Sep. 1992. (Pubitemid 23598170)
    • (1992) IEE Proceedings B: Electric Power Applications , vol.139 , Issue.5 , pp. 429-442
    • Cadirci, I.1    Ermis, M.2
  • 33
    • 82155162497 scopus 로고    scopus 로고
    • Modeling and ride-through control of doubly fed induction generators during symmetrical voltage sags
    • Dec
    • V. Flores Mendes, C. V. de Sousa, S. R. Silva, J. Rabelo, and W. Hofmann, "Modeling and ride-through control of doubly fed induction generators during symmetrical voltage sags," IEEE Trans. Energy Convers., vol. 26, no. 4, pp. 1161-1171, Dec. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.4 , pp. 1161-1171
    • Flores Mendes, V.1    De Sousa, C.V.2    Silva, S.R.3    Rabelo, J.4    Hofmann, W.5
  • 34
    • 0021389576 scopus 로고
    • Cycloconvertor-excited divided-winding doubly-fed machine as a wind-power convertor
    • P. G. Holmes and N. A. Elsonbaty, "Cycloconvertor-excited dividedwinding doubly-fed machine as a wind-power convertor," Proc. Inst. Elect. Eng.-Elect. Power Appl., vol. 131, no. 2, pp. 61-69, Mar. 1984. (Pubitemid 14525947)
    • (1984) IEE Proceedings B: Electric Power Applications , vol.131 , Issue.2 , pp. 61-69
    • Holmes, P.G.1    Elsonbaty, N.A.2
  • 35
    • 78649942403 scopus 로고    scopus 로고
    • Direct active and reactive power regulation of DFIG using sliding-mode control approach
    • Dec
    • J. Hu, H. Nian, B. Hu, Y. He, and Z. Q. Zhu, "Direct active and reactive power regulation of DFIG using sliding-mode control approach," IEEE Trans. Energy Convers., vol. 25, no. 4, pp. 1028-1039, Dec. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.4 , pp. 1028-1039
    • Hu, J.1    Nian, H.2    Hu, B.3    He, Y.4    Zhu, Z.Q.5
  • 36
    • 83355175410 scopus 로고    scopus 로고
    • Predictive direct virtual torque control of doubly fed induction generator for grid synchronization
    • J. Hu, J. Zhu, Q. Ma, and Y. Zhang, "Predictive direct virtual torque control of doubly fed induction generator for grid synchronization," in Proc. ICEMS, 2011, pp. 1-6.
    • (2011) Proc. ICEMS , pp. 1-6
    • Hu, J.1    Zhu, J.2    Ma, Q.3    Zhang, Y.4
  • 37
    • 84859012909 scopus 로고    scopus 로고
    • Control of DFIG wind turbine with direct-current vector control configuration
    • Jan
    • S. Li, T. A. Haskew, K. A. Williams, and R. P. Swatloski, "Control of DFIG wind turbine with direct-current vector control configuration," IEEE Trans. Sustain. Energy, vol. 3, no. 1, pp. 1-11, Jan. 2012.
    • (2012) IEEE Trans. Sustain. Energy , vol.3 , Issue.1 , pp. 1-11
    • Li, S.1    Haskew, T.A.2    Williams, K.A.3    Swatloski, R.P.4
  • 38
    • 42549152712 scopus 로고    scopus 로고
    • A novel direct torque control of doubly-fed induction generator used for variable speed wind power generation
    • Z. Liu, O. A. Mohammed, and S. Liu, "A novel direct torque control of doubly-fed induction generator used for variable speed wind power generation," in Proc. IEEE Power Eng. Soc.Gen.Meeting, 2007, pp. 1-6.
    • (2007) Proc. IEEE Power Eng. Soc.Gen. Meeting , pp. 1-6
    • Liu, Z.1    Mohammed, O.A.2    Liu, S.3
  • 39
    • 79955781437 scopus 로고    scopus 로고
    • A new direct torque control of doubly-fed induction generator under unbalanced grid voltage
    • B. B. Pimple, V. Y. Vekhande, and B. G. Fernandes, "A new direct torque control of doubly-fed induction generator under unbalanced grid voltage," in Proc. 6th Annu. IEEE APEC Expo., 2011, pp. 1576-1581.
    • (2011) Proc. 6th Annu. IEEE APEC Expo. , pp. 1576-1581
    • Pimple, B.B.1    Vekhande, V.Y.2    Fernandes, B.G.3
  • 40
    • 79952849991 scopus 로고    scopus 로고
    • Comparison of control strategy for Double-Fed Induction Generator (DFIG)
    • L. Qizhong, Y. Lan, and W. Guoxiang, "Comparison of control strategy for Double-Fed Induction Generator (DFIG)," in Proc. 3rd ICMTMA, 2011, vol. 1, pp. 741-744.
    • (2011) Proc. 3rd ICMTMA , vol.1 , pp. 741-744
    • Qizhong, L.1    Lan, Y.2    Guoxiang, W.3
  • 41
    • 70349628410 scopus 로고    scopus 로고
    • Reactive power control design in doubly fed induction generators for wind turbines
    • Oct
    • B. C. Rabelo, W. Hofmann, J. L. da Silva, R. G. de Oliveira, and S. R. Silva, "Reactive power control design in doubly fed induction generators for wind turbines," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4154-4162, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4154-4162
    • Rabelo, B.C.1    Hofmann, W.2    Da Silva, J.L.3    De Oliveira, R.G.4    Silva, S.R.5
  • 42
    • 57349122088 scopus 로고    scopus 로고
    • Direct power control applied to doubly fed induction generator under unbalanced grid voltage conditions
    • Sep
    • D. Santos-Martin, J. L. Rodriguez-Amenedo, and S. Arnalte, "Direct power control applied to doubly fed induction generator under unbalanced grid voltage conditions," IEEE Trans. Power Electron., vol. 23, no. 5, pp. 2328-2336, Sep. 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.5 , pp. 2328-2336
    • Santos-Martin, D.1    Rodriguez-Amenedo, J.L.2    Arnalte, S.3
  • 43
    • 0017501761 scopus 로고
    • Static scherbius system of induction-motor speed control
    • G. A. Smith, "Static Scherbius system of induction-motor speed control," Proc. Inst. Elect. Eng., vol. 124, no. 6, pp. 557-560, Jun. 1977. (Pubitemid 8553652)
    • (1977) Proceedings of the Institution of Electrical Engineers , vol.124 , Issue.6 , pp. 557-560
    • Smith, G.A.1
  • 45
    • 79959567612 scopus 로고    scopus 로고
    • Comparative study of control strategies for the doubly fed induction generator in wind energy conversion systems: A DSP-based implementation approach
    • Jul
    • E. Tremblay, S. Atayde, and A. Chandra, "Comparative study of control strategies for the doubly fed induction generator in wind energy conversion systems: A DSP-based implementation approach," IEEE Trans. Sustain. Energy, vol. 2, no. 3, pp. 288-299, Jul. 2011.
    • (2011) IEEE Trans. Sustain. Energy , vol.2 , Issue.3 , pp. 288-299
    • Tremblay, E.1    Atayde, S.2    Chandra, A.3
  • 46
    • 0028396564 scopus 로고
    • Modelling and output power optimisation of a wind turbine driven double output induction generator
    • Mar
    • M. Y. Uctug, I. Eskandarzadeh, and H. Ince, "Modelling and output power optimisation of a wind turbine driven double output induction generator," Proc. Inst. Elect. Eng.-Elect. Power Appl., vol. 141, no. 2, pp. 33-38, Mar. 1994.
    • (1994) Proc. Inst. Elect. Eng.-Elect. Power Appl. , vol.141 , Issue.2 , pp. 33-38
    • Uctug, M.Y.1    Eskandarzadeh, I.2    Ince, H.3
  • 47
    • 67650079491 scopus 로고    scopus 로고
    • Direct control algorithm for doubly fed induction generators in weak grids
    • Jul
    • K. C.Wong, S. L. Ho, and K.W. E. Cheng, "Direct control algorithm for doubly fed induction generators in weak grids," IET Elect. Power Appl., vol. 3, no. 4, pp. 371-380, Jul. 2009.
    • (2009) IET Elect. Power Appl. , vol.3 , Issue.4 , pp. 371-380
    • Wong, C.K.1    Ho, S.L.2    Cheng, K.W.E.3
  • 48
    • 50049106578 scopus 로고    scopus 로고
    • Direct power control for wind-turbine driven doubly-fed induction generator with constant switch frequency
    • G. Xiao-Ming, S. Dan, H. Ben-Teng, and H. Ling-Ling, "Direct power control for wind-turbine driven doubly-fed induction generator with constant switch frequency," in Proc. ICEMS, 2007, pp. 253-258.
    • (2007) Proc. ICEMS , pp. 253-258
    • Xiao-Ming, G.1    Dan, S.2    Ben-Teng, H.3    Ling-Ling, H.4
  • 49
    • 33947418456 scopus 로고    scopus 로고
    • Direct active and reactive power control of DFIG for wind energy generation
    • DOI 10.1109/TEC.2006.875472
    • L. Xu and P. Cartwright, "Direct active and reactive power control of DFIG for wind energy generation," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 750-758, Sep. 2006. (Pubitemid 46445164)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 750-758
    • Xu, L.1    Cartwright, P.2
  • 50
    • 0026238031 scopus 로고
    • Active and reactive power control for doubly-fed wound rotor induction generator
    • DOI 10.1109/63.97761
    • M. Yamamoto and O. Motoyoshi, "Active and reactive power control for doubly-fed wound rotor induction generator," IEEE Trans. Power Electron., vol. 6, no. 4, pp. 624-629, Oct. 1991. (Pubitemid 21716209)
    • (1991) IEEE Transactions on Power Electronics , vol.6 , Issue.4 , pp. 624-629
    • Yamamoto Mitsutoshi1    Motoyoshi Osamu2
  • 51
    • 33947703689 scopus 로고    scopus 로고
    • Direct power control of DFIG with constant switching frequency and improved transient performance
    • DOI 10.1109/TEC.2006.889549, Special Issue on Wind Power
    • D. Zhi and L. Xu, "Direct power control of DFIG with constant switching frequency and improved transient performance," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 110-118, Mar. 2007. (Pubitemid 46487483)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.1 , pp. 110-118
    • Zhi, D.1    Xu, L.2
  • 52
    • 84862707483 scopus 로고
    • Neue methode zur regelung von asynchronen motoren
    • C. Kramer, "Neue methode zur regelung von asynchronen motoren," Elektrotech.Z., vol. 29, p. 734, 1908.
    • (1908) Elektrotech.Z. , vol.29 , pp. 734
    • Kramer, C.1
  • 53
    • 0002707790 scopus 로고
    • Induction motor speed control with static inverter in the rotor
    • Jan
    • A. Lavi and R. J. Polge, "Induction motor speed control with static inverter in the rotor," IEEE Trans. Power App. Syst., vol. PAS-85, no. 1, pp. 76-84, Jan. 1966.
    • (1966) IEEE Trans. Power App. Syst. , vol.PAS-85 , Issue.1 , pp. 76-84
    • Lavi, A.1    Polge, R.J.2
  • 54
    • 0025152555 scopus 로고
    • Steady state analysis and experimental investigation of a doubly-fed induction machine supplied by a 'current-source' cycloconverter in the rotor
    • M. Machmoum, M. Cherkaoui, R. le Doeuff, and F. M. Sargos, "Steady state analysis and experimental investigation of a doubly-fed induction machine supplied by a 'current-source' cycloconverter in the rotor," in Proc. 4th Int. Conf. Power Electron. Variable-Speed Drives, 1990, pp. 81-86. (Pubitemid 20728043)
    • (1990) IEE Conference Publication , Issue.324 , pp. 81-86
    • Machmoum, M.1    Cherkaoui, M.2    Le Doeuff, R.3    Sargos, F.M.4
  • 55
    • 0038043135 scopus 로고    scopus 로고
    • Modeling and control of a wind turbine driven doubly fed induction generator
    • Jun
    • A. Tapia, G. Tapia, J. X. Ostolaza, and J. R. Saenz, "Modeling and control of a wind turbine driven doubly fed induction generator," IEEE Trans. Energy Convers., vol. 18, no. 2, pp. 194-204, Jun. 2003.
    • (2003) IEEE Trans. Energy Convers. , vol.18 , Issue.2 , pp. 194-204
    • Tapia, A.1    Tapia, G.2    Ostolaza, J.X.3    Saenz, J.R.4
  • 56
    • 70349612968 scopus 로고    scopus 로고
    • Stability analysis of a wind energy conversion system based on a doubly fed induction generator fed by a matrix converter
    • Oct
    • R. Cardenas, R. Pena, G. Tobar, J. Clare, P. Wheeler, and G. Asher, "Stability analysis of a wind energy conversion system based on a doubly fed induction generator fed by a matrix converter," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4194-4206, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4194-4206
    • Cardenas, R.1    Pena, R.2    Tobar, G.3    Clare, J.4    Wheeler, P.5    Asher, G.6
  • 57
    • 70349612250 scopus 로고    scopus 로고
    • A topology for multiple generation system with doubly fed induction machines and indirect matrix converter
    • Oct
    • R. Pena, R. Cardenas, E. Reyes, J. Clare, and P. Wheeler, "A topology for multiple generation system with doubly fed induction machines and indirect matrix converter," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4181-4193, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4181-4193
    • Pena, R.1    Cardenas, R.2    Reyes, E.3    Clare, J.4    Wheeler, P.5
  • 58
    • 0035329744 scopus 로고    scopus 로고
    • Vector control methods for induction machines: An overview
    • DOI 10.1109/13.925828, PII S0018935901038638
    • J. A. Santisteban and R. M. Stephan, "Vector control methods for induction machines: An overview," IEEE Trans. Educ., vol. 44, no. 2, pp. 170- 175, May 2001. (Pubitemid 32609836)
    • (2001) IEEE Transactions on Education , vol.44 , Issue.2 , pp. 170-175
    • Santisteban, J.A.1    Stephan, R.M.2
  • 60
    • 40849100539 scopus 로고    scopus 로고
    • Wind-diesel generation using doubly fed induction machines
    • DOI 10.1109/TEC.2007.914681
    • R. Pena, R. Cardenas, J. Proboste, J. Clare, and G. Asher, "Wind-diesel generation using doubly fed induction machines," IEEE Trans. Energy Convers., vol. 23, no. 1, pp. 202-214, Mar. 2008. (Pubitemid 351392315)
    • (2008) IEEE Transactions on Energy Conversion , vol.23 , Issue.1 , pp. 202-214
    • Pena, R.1    Cardenas, R.2    Proboste, J.3    Clare, J.4    Asher, G.5
  • 61
    • 38349018990 scopus 로고    scopus 로고
    • Sensorless control of doubly-fed induction generators using a rotor-current-based MRAS observer
    • Jan
    • R. Peña, R. Cardenas, J. Proboste, G. Asher, and J. Clare, "Sensorless control of doubly-fed induction generators using a rotor-current-based MRAS observer," IEEE Trans. Ind. Electron., vol. 55, no. 1, pp. 330- 339, Jan. 2008.
    • (2008) IEEE Trans. Ind. Electron. , vol.55 , Issue.1 , pp. 330-339
    • Peña, R.1    Cardenas, R.2    Proboste, J.3    Asher, G.4    Clare, J.5
  • 62
    • 33847716755 scopus 로고    scopus 로고
    • Power flow optimisation and grid integration of wind turbines with the doubly-fed induction generator
    • DOI 10.1109/PESC.2005.1582050, 1582050, 36th IEEE Power Electronics Specialists Conference 2005
    • B. Rabelo and W. Hofmann, "Power flow optimisation and grid integration of wind turbines with the doubly-fed induction generator," in Proc. IEEE Power Electron. Spec. Conf., 2005, pp. 2930-2936. (Pubitemid 46379595)
    • (2005) PESC Record - IEEE Annual Power Electronics Specialists Conference , vol.2005 , pp. 2930-2936
    • Rabelo, B.1    Hofmann, W.2
  • 63
    • 51049093767 scopus 로고    scopus 로고
    • A high power density converter system for the Gamesa G10x 4, 5 MW wind turbine keywords
    • B. Andresen and J. Birk, "A high power density converter system for the Gamesa G10x 4, 5 MW wind turbine keywords," in Proc. Eur. Conf. Power Electron. Appl., 2007, pp. 1-8.
    • (2007) Proc. Eur. Conf. Power Electron. Appl. , pp. 1-8
    • Andresen, B.1    Birk, J.2
  • 65
    • 84874832793 scopus 로고    scopus 로고
    • Method for operation of a converter system
    • Gamesa Patent 754 505 2B2, May 14
    • J. Llorente, A. Bjorn, and J. Birk, "Method for operation of a converter system," Gamesa Patent 754 505 2B2, May 14, 2008.
    • (2008)
    • Llorente, J.1    Bjorn, A.2    Birk, J.3
  • 66
    • 35048813951 scopus 로고    scopus 로고
    • A new torque and flux controller for direct torque control of induction machines
    • DOI 10.1109/TIA.2006.882685
    • N. R. N. Idris, C. L. Toh, and M. E. Elbuluk, "A new torque and flux controller for direct torque control of induction machines," IEEE Trans. Ind. Appl., vol. 42, no. 6, pp. 1358-1366, Nov./Dec. 2006. (Pubitemid 44824035)
    • (2006) IEEE Transactions on Industry Applications , vol.42 , Issue.6 , pp. 1358-1366
    • Idris, N.R.N.1    Toh, C.L.2    Elbuluk, M.E.3
  • 67
    • 38349058764 scopus 로고    scopus 로고
    • Dual direct torque control of doubly fed induction machine
    • Oct
    • F. Bonnet, P.-E. Vidal, and M. Pietrzak-David, "Dual direct torque control of doubly fed induction machine," IEEE Trans. Ind. Electron., vol. 54, no. 5, pp. 2482-2490, Oct. 2007.
    • (2007) IEEE Trans. Ind. Electron. , vol.54 , Issue.5 , pp. 2482-2490
    • Bonnet, F.1    Vidal, P.-E.2    Pietrzak-David, M.3
  • 68
    • 77952954068 scopus 로고    scopus 로고
    • Direct torque control for doubly fed induction machine-based wind turbines under voltage dips and without crowbar protection
    • Jun
    • G. Abad, M. A. Rodriguez, J. Poza, and J. M. Canales, "Direct torque control for doubly fed induction machine-based wind turbines under voltage dips and without crowbar protection," IEEE Trans. Energy Convers., vol. 25, no. 2, pp. 586-588, Jun. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.2 , pp. 586-588
    • Abad, G.1    Rodriguez, M.A.2    Poza, J.3    Canales, J.M.4
  • 69
    • 44449114106 scopus 로고    scopus 로고
    • Two-level VSC based predictive direct torque control of the doubly fed induction machine with reduced torque and flux ripples at low constant switching frequency
    • DOI 10.1109/TPEL.2008.921160
    • G. Abad, M. A. Rodriguez, and J. Poza, "Two-level VSC based predictive direct torque control of the doubly fed induction machine with reduced torque and flux ripples at low constant switching frequency," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1050-1061, May 2008. (Pubitemid 351756682)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1050-1061
    • Abad, G.1    Rodriguez, M.A.2    Poza, J.3
  • 70
    • 84874898944 scopus 로고    scopus 로고
    • ABB, ABB, Zurich, Switzerland. [Online]
    • ABB, ABB low voltage wind turbine converters ACS800-67, 0.6 to 2.2 MW, Zurich, Switzerland, 2012. [Online]. Available: http://www05.abb.com/global/ scot/scot201.nsf/veritydisplay/d971c93658b48422c1257799002541f5/$file/ acs800-67-wind%20turbine%20converter-flyer-3aua0000086088-en-rev%20a.pdf
    • (2012) ABB Low Voltage Wind Turbine Converters ACS800-67, 0.6 to 2.2 MW
  • 71
    • 0032073781 scopus 로고    scopus 로고
    • Direct power control of PWM converter without power-source voltage sensors
    • PII S0093999498038808
    • T. Noguchi, H. Tomiki, S. Kondo, and I. Takahashi, "Direct power control of PWM converter without power-source voltage sensors," IEEE Trans. Ind. Appl., vol. 34, no. 3, pp. 473-479, May/Jun. 1998. (Pubitemid 128740176)
    • (1998) IEEE Transactions on Industry Applications , vol.34 , Issue.3 , pp. 473-479
    • Noguchi, T.1    Tomiki, H.2    Kondo, S.3    Takahashi, I.4
  • 72
    • 0037954489 scopus 로고    scopus 로고
    • Analysis and design of Direct Power Control (DPC) for a three phase synchronous rectifier via output regulation subspaces
    • May
    • G. Escobar, A. M. Stankovic, J. M. Carrasco, E. Galvan, and R. Ortega, "Analysis and design of Direct Power Control (DPC) for a three phase synchronous rectifier via output regulation subspaces," IEEE Trans. Power Electron., vol. 18, no. 3, pp. 823-830, May 2003.
    • (2003) IEEE Trans. Power Electron. , vol.18 , Issue.3 , pp. 823-830
    • Escobar, G.1    Stankovic, A.M.2    Carrasco, J.M.3    Galvan, E.4    Ortega, R.5
  • 74
    • 0035330905 scopus 로고    scopus 로고
    • Direct power control of grid-connected wound rotor induction machine without rotor position sensors
    • DOI 10.1109/63.923772, PII S0885899301040352
    • R. Datta and V. T. Ranganathan, "Direct power control of grid-connected wound rotor induction machine without rotor position sensors," IEEE Trans. Power Electron., vol. 16, no. 3, pp. 390-399, May 2001. (Pubitemid 32534596)
    • (2001) IEEE Transactions on Power Electronics , vol.16 , Issue.3 , pp. 390-399
    • Datta, R.1    Ranganathan, V.T.2
  • 75
    • 29244434858 scopus 로고    scopus 로고
    • Control of a switched reluctance generator for variable-speed wind energy applications
    • DOI 10.1109/TEC.2005.853733
    • R. Cardenas, R. Pena, M. Perez, J. Clare, G. Asher, and P. Wheeler, "Control of a switched reluctance generator for variable-speed wind energy applications," IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 781- 791, Dec. 2005. (Pubitemid 41830054)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.4 , pp. 781-791
    • Cardenas, R.1    Pena, R.2    Perez, M.3    Clare, J.4    Asher, G.5    Wheeler, P.6
  • 76
    • 63149149467 scopus 로고    scopus 로고
    • Sensorless control for a switched reluctance wind generator, based on current slopes and neural networks
    • Mar
    • E. Echenique, J. Dixon, R. Cardenas, and R. Pena, "Sensorless control for a switched reluctance wind generator, based on current slopes and neural networks," IEEE Trans. Ind. Electron., vol. 56, no. 3, pp. 817- 825, Mar. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.3 , pp. 817-825
    • Echenique, E.1    Dixon, J.2    Cardenas, R.3    Pena, R.4
  • 77
    • 84858714112 scopus 로고    scopus 로고
    • A review of maximum power point tracking algorithms for wind energy systems
    • Jun
    • M. A. Abdullah, A. H. M. Yatim, C. W. Tan, and R. Saidur, "A review of maximum power point tracking algorithms for wind energy systems," Renew. Sustain. Energy Rev., vol. 16, no. 5, pp. 3220-3227, Jun. 2012.
    • (2012) Renew. Sustain. Energy Rev. , vol.16 , Issue.5 , pp. 3220-3227
    • Abdullah, M.A.1    Yatim, A.H.M.2    Tan, C.W.3    Saidur, R.4
  • 78
    • 1542285787 scopus 로고    scopus 로고
    • Sensorless vector control of induction machines for variable-speed wind energy applications
    • Mar
    • R. Cardenas and R. Pena, "Sensorless vector control of induction machines for variable-speed wind energy applications," IEEE Trans. Energy Convers., vol. 19, no. 1, pp. 196-205, Mar. 2004.
    • (2004) IEEE Trans. Energy Convers. , vol.19 , Issue.1 , pp. 196-205
    • Cardenas, R.1    Pena, R.2
  • 79
    • 84866632003 scopus 로고    scopus 로고
    • Lyapunov-designed super-twisting sliding mode control for wind energy conversion optimization
    • Feb
    • C. Evangelista, P. Puleston, F. Valenciaga, and L. M. Fridman, "Lyapunov-designed super-twisting sliding mode control for wind energy conversion optimization," IEEE Trans. Ind. Electron., vol. 60, no. 2, pp. 538-545, Feb. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.2 , pp. 538-545
    • Evangelista, C.1    Puleston, P.2    Valenciaga, F.3    Fridman, L.M.4
  • 80
    • 84868087222 scopus 로고    scopus 로고
    • Wind turbine power coefficient analysis of a new maximum power point tracking technique
    • Mar
    • Y. Xia, K. H. Ahmed, and B. W. Williams, "Wind turbine power coefficient analysis of a new maximum power point tracking technique," IEEE Trans. Ind. Electron., vol. 60, no. 3, pp. 1122-1132, Mar. 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.3 , pp. 1122-1132
    • Xia, Y.1    Ahmed, K.H.2    Williams, B.W.3
  • 81
    • 84867963240 scopus 로고    scopus 로고
    • Quantum-inspired particle swarm optimization for power system operations considering wind power uncertainty and carbon tax in Australia
    • Nov
    • F. Yao, Z. Y. Dong, K. Meng, Z. Xu, H. H. Iu, and K. P. Wong, "Quantum-inspired particle swarm optimization for power system operations considering wind power uncertainty and carbon tax in Australia," IEEE Trans. Ind. Informat., vol. 8, no. 4, pp. 880-888, Nov. 2012.
    • (2012) IEEE Trans. Ind. Informat. , vol.8 , Issue.4 , pp. 880-888
    • Yao, F.1    Dong, Z.Y.2    Meng, K.3    Xu, Z.4    Iu, H.H.5    Wong, K.P.6
  • 83
    • 84874822938 scopus 로고    scopus 로고
    • Dynamic response analysis of small wind energy conversion systems (WECS) operating with torque control versus speed control
    • L. G. González, E. Figueres, G. Garcerá, and O. Carranza, "Dynamic response analysis of small wind energy conversion systems (WECS) operating with torque control versus speed control," in Proc. ICREPQ, 2009, pp. 1-5.
    • (2009) Proc. ICREPQ , pp. 1-5
    • González, L.G.1    Figueres, E.2    Garcerá, G.3    Carranza, O.4
  • 84
    • 17044373671 scopus 로고    scopus 로고
    • Wind generation optimisation algorithm for a doubly fed induction generator
    • DOI 10.1049/ip-gtd:20041061
    • G. Tapia and A. Tapia, "Wind generation optimisation algorithm for a doubly fed induction generator," Proc. Inst. Elect. Eng.-Gen. Transmiss. Distrib., vol. 152, no. 2, pp. 253-263, Mar. 2005. (Pubitemid 40497034)
    • (2005) IEE Proceedings: Generation, Transmission and Distribution , vol.152 , Issue.2 , pp. 253-263
    • Tapia, G.1    Tapia, A.2
  • 85
    • 33746054925 scopus 로고    scopus 로고
    • Experimental evaluation of wind turbines maximum power point tracking controllers
    • DOI 10.1016/j.enconman.2006.03.033, PII S0196890406001245
    • H. Camblong, I. M. de Alegria, M. Rodriguez, and G. Abad, "Experimental evaluation of wind turbines maximum power point tracking controllers," Energy Convers. Manage., vol. 47, no. 18/19, pp. 2846- 2858, Nov. 2006. (Pubitemid 44069605)
    • (2006) Energy Conversion and Management , vol.47 , Issue.18-19 , pp. 2846-2858
    • Camblong, H.1    De Alegria, I.M.2    Rodriguez, M.3    Abad, G.4
  • 86
    • 80055038462 scopus 로고    scopus 로고
    • A study of maximum power point tracking algorithms for wind energy system
    • M. A. Abdullah, A. H. M. Yatim, and C. Wei, "A study of maximum power point tracking algorithms for wind energy system," in Proc. IEEE Conf. CET, 2011, pp. 321-326.
    • (2011) Proc. IEEE Conf. CET , pp. 321-326
    • Abdullah, M.A.1    Yatim, A.H.M.2    Wei, C.3
  • 87
    • 70449626165 scopus 로고    scopus 로고
    • A comparison of maximum-power-point tracking control techniques for low-power variable-speed wind generators
    • Jul. 1-3
    • C. Patsios, A. Chaniotis, M. Rotas, and A. G. Kladas, "A comparison of maximum-power-point tracking control techniques for low-power variable-speed wind generators," in Proc. ELECTROMOTION, Jul. 1-3, 2009, pp. 1-6.
    • (2009) Proc. ELECTROMOTION , pp. 1-6
    • Patsios, C.1    Chaniotis, A.2    Rotas, M.3    Kladas, A.G.4
  • 88
    • 33947657812 scopus 로고    scopus 로고
    • Control of a doubly-fed induction wind generator under unbalanced grid voltage conditions
    • T. Brekken, N. Mohan, and T. Undeland, "Control of a doubly-fed induction wind generator under unbalanced grid voltage conditions," in Proc. Eur. Conf. Power Electron. Appl., 2005, p. 10.
    • (2005) Proc. Eur. Conf. Power Electron. Appl. , pp. 10
    • Brekken, T.1    Mohan, N.2    Undeland, T.3
  • 89
    • 33947613668 scopus 로고    scopus 로고
    • Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    • DOI 10.1109/TEC.2006.889550, Special Issue on Wind Power
    • T. K. A. Brekken and N. Mohan, "Control of a doubly fed induction wind generator under unbalanced grid voltage conditions," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 129-135, Mar. 2007. (Pubitemid 46487485)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.1 , pp. 129-135
    • Brekken, T.K.A.1    Mohan, N.2
  • 90
    • 82155168213 scopus 로고    scopus 로고
    • DFIG power generation capability and feasibility regions under unbalanced grid voltage conditions
    • Dec
    • M. I. Martinez, G. Tapia, A. Susperregui, and H. Camblong, "DFIG power generation capability and feasibility regions under unbalanced grid voltage conditions," IEEE Trans. Energy Convers., vol. 26, no. 4, pp. 1051-1062, Dec. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.4 , pp. 1051-1062
    • Martinez, M.I.1    Tapia, G.2    Susperregui, A.3    Camblong, H.4
  • 91
    • 34249802057 scopus 로고    scopus 로고
    • Control system for unbalanced operation of stand-alone doubly fed induction generators
    • DOI 10.1109/TEC.2007.895393
    • R. Peña, R. Cárdenas, E. Escobar, J. Clare, and P. Wheeler, "Control system for unbalanced operation of stand-alone doubly fed induction generators," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 544-545, Jun. 2007. (Pubitemid 46845657)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 544-545
    • Pena, R.1    Cardenas, R.2    Escobar, E.3    Clare, J.4    Wheeler, P.5
  • 92
    • 57349152192 scopus 로고    scopus 로고
    • Control strategy for a doublyfed induction generator feeding an unbalanced grid or stand-alone load
    • Feb
    • R. Pena, R. Cardenas, and E. Escobar, "Control strategy for a doublyfed induction generator feeding an unbalanced grid or stand-alone load," Elect. Power Syst. Res., vol. 79, no. 2, pp. 355-364, Feb. 2009.
    • (2009) Elect. Power Syst. Res. , vol.79 , Issue.2 , pp. 355-364
    • Pena, R.1    Cardenas, R.2    Escobar, E.3
  • 93
    • 79956312957 scopus 로고    scopus 로고
    • Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems
    • Mar.
    • V.-T. Phan and H.-H. Lee, "Improved predictive current control for unbalanced stand-alone doubly-fed induction generator-based wind power systems," IET Elect. Power Appl., vol. 5, no. 3, pp. 275-287, Mar. 2011.
    • (2011) IET Elect. Power Appl. , vol.5 , Issue.3 , pp. 275-287
    • Phan, V.-T.1    Lee, H.-H.2
  • 94
    • 34247104981 scopus 로고    scopus 로고
    • Sensorless direct voltage control of the stand-alone slip-ring induction generator
    • DOI 10.1109/TIE.2007.892746
    • G. Iwanski and W. Koczara, "Sensorless direct voltage control of the stand-alone slip-ring induction generator," IEEE Trans. Ind. Electron., vol. 54, no. 2, pp. 1237-1239, Apr. 2007. (Pubitemid 46591045)
    • (2007) IEEE Transactions on Industrial Electronics , vol.54 , Issue.2 , pp. 1237-1239
    • Iwanski, G.1    Koczara, W.2
  • 95
    • 84863011990 scopus 로고    scopus 로고
    • Performance enhancement of stand-alone DFIG systems with control of rotor and load side converters using resonant controllers
    • Jan./Feb
    • V.-T. Phan and H.-H. Lee, "Performance enhancement of stand-alone DFIG systems with control of rotor and load side converters using resonant controllers," IEEE Trans. Ind. Appl., vol. 48, no. 1, pp. 199-210, Jan./Feb. 2012.
    • (2012) IEEE Trans. Ind. Appl. , vol.48 , Issue.1 , pp. 199-210
    • Phan, V.-T.1    Lee, H.-H.2
  • 96
    • 0028443468 scopus 로고
    • Analysis of wind driven grid connected induction generators under unbalanced grid conditions
    • Jun
    • G. H. Ghorashi, S. Murthy, B. P. Singh, and B. Singh, "Analysis of wind driven grid connected induction generators under unbalanced grid conditions," IEEE Trans. Energy Convers., vol. 9, no. 2, pp. 217-223, Jun. 1994.
    • (1994) IEEE Trans. Energy Convers. , vol.9 , Issue.2 , pp. 217-223
    • Ghorashi, G.H.1    Murthy, S.2    Singh, B.P.3    Singh, B.4
  • 98
    • 61649105219 scopus 로고    scopus 로고
    • Operation of gridconnected DFIG under unbalanced grid voltage condition
    • Mar
    • Y. Zhou, P. Bauer, J. A. Ferreira, and J. Pierik, "Operation of gridconnected DFIG under unbalanced grid voltage condition," IEEE Trans. Energy Convers., vol. 24, no. 1, pp. 240-246, Mar. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.1 , pp. 240-246
    • Zhou, Y.1    Bauer, P.2    Ferreira, J.A.3    Pierik, J.4
  • 99
    • 33947313847 scopus 로고    scopus 로고
    • Dynamic modeling and control of DFIG-based wind turbines under unbalanced network conditions
    • DOI 10.1109/TPWRS.2006.889113
    • L. Xu and Y. Wang, "Dynamic modeling and control of DFIG-based wind turbines under unbalanced network conditions," IEEE Trans. Power Syst., vol. 22, no. 1, pp. 314-323, Feb. 2007. (Pubitemid 46437741)
    • (2007) IEEE Transactions on Power Systems , vol.22 , Issue.1 , pp. 314-323
    • Xu, L.1    Wang, Y.2
  • 100
    • 0042658183 scopus 로고    scopus 로고
    • A novel doubly-fed induction wind generator control scheme for reactive power control and torque pulsation compensation under unbalanced grid voltage conditions
    • Acapulco, Mexico
    • T. Brekken and N. Mohan, "A novel doubly-fed induction wind generator control scheme for reactive power control and torque pulsation compensation under unbalanced grid voltage conditions," in Proc. 34th IEEE Annu. Power Electron. Spec. Conf., Acapulco, Mexico, 2003, pp. 15-19.
    • (2003) Proc. 34th IEEE Annu. Power Electron. Spec. Conf. , pp. 15-19
    • Brekken, T.1    Mohan, N.2
  • 101
    • 56749103139 scopus 로고    scopus 로고
    • Compensation of network voltage unbalance using doubly fed induction generator-based wind farms
    • Mar
    • Y.Wang, L. Xu, and B.W.Williams, "Compensation of network voltage unbalance using doubly fed induction generator-based wind farms," IET Renew. Power Gen., vol. 3, no. 1, pp. 12-22, Mar. 2009.
    • (2009) IET Renew. Power Gen. , vol.3 , Issue.1 , pp. 12-22
    • Wang, Y.1    Xu, L.2    Williams, B.W.3
  • 102
    • 60449101280 scopus 로고    scopus 로고
    • Improved control of DFIG systems during network unbalance using PI-R current regulators
    • Feb
    • J. Hu, Y. He, L. Xu, and B. W. Williams, "Improved control of DFIG systems during network unbalance using PI-R current regulators," IEEE Trans. Ind. Electron., vol. 56, no. 2, pp. 439-451, Feb. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.2 , pp. 439-451
    • Hu, J.1    He, Y.2    Xu, L.3    Williams, B.W.4
  • 103
    • 70749090496 scopus 로고    scopus 로고
    • Reinforced control and operation of DFIG-based windpower- generation system under unbalanced grid voltage conditions
    • Dec
    • J. Hu and Y. He, "Reinforced control and operation of DFIG-based windpower- generation system under unbalanced grid voltage conditions," IEEE Trans. Energy Convers., vol. 24, no. 4, pp. 905-915, Dec. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.4 , pp. 905-915
    • Hu, J.1    He, Y.2
  • 104
    • 77949925218 scopus 로고    scopus 로고
    • An improved control method for DFIG-based wind system supplying unbalanced stand-alone loads
    • V.-T. Phan, S.-H. Kwak, and H.-H. Lee, "An improved control method for DFIG-based wind system supplying unbalanced stand-alone loads," in Proc. IEEE ISIE, 2009, pp. 1081-1086.
    • (2009) Proc. IEEE ISIE , pp. 1081-1086
    • Phan, V.-T.1    Kwak, S.-H.2    Lee, H.-H.3
  • 105
    • 78650161183 scopus 로고    scopus 로고
    • Control of an unbalanced stand-alone DFIGbased wind system using predictive current control method
    • V.-T. Phan and H.-H. Lee, "Control of an unbalanced stand-alone DFIGbased wind system using predictive current control method," in Proc. IEEE ECCE, 2010, pp. 2521-2528.
    • (2010) Proc. IEEE ECCE , pp. 2521-2528
    • Phan, V.-T.1    Lee, H.-H.2
  • 106
    • 80051771432 scopus 로고    scopus 로고
    • Robust controller for DFIGs of grid-connected wind turbines
    • Sep
    • J. P. da Costa, H. Pinheiro, T. Degner, and G. Arnold, "Robust controller for DFIGs of grid-connected wind turbines," IEEE Trans. Ind. Electron., vol. 58, no. 9, pp. 4023-4038, Sep. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.9 , pp. 4023-4038
    • Da Costa, J.P.1    Pinheiro, H.2    Degner, T.3    Arnold, G.4
  • 107
    • 84863769799 scopus 로고    scopus 로고
    • Design and implementation of four-leg voltage-source-converter-based VFC for autonomous wind energy conversion system
    • Dec
    • B. Singh and S. Sharma, "Design and implementation of four-leg voltage-source-converter-based VFC for autonomous wind energy conversion system," IEEE Trans. Ind. Electron., vol. 59, no. 12, pp. 4694- 4703, Dec. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.12 , pp. 4694-4703
    • Singh, B.1    Sharma, S.2
  • 108
    • 80053637688 scopus 로고    scopus 로고
    • Analysis and experimental validation of control systems for four-leg matrix converter applications
    • Jan
    • R. Cardenas, C. Juri, R. Pena, J. Clare, and P. Wheeler, "Analysis and experimental validation of control systems for four-leg matrix converter applications," IEEE Trans. Ind. Electron., vol. 59, no. 1, pp. 141-153, Jan. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.1 , pp. 141-153
    • Cardenas, R.1    Juri, C.2    Pena, R.3    Clare, J.4    Wheeler, P.5
  • 109
    • 79952637476 scopus 로고    scopus 로고
    • Experimental validation of a space vector modulation algorithm for four-leg matrix converters
    • Apr
    • R. Cardenas, R. Pena, P. Wheeler, and J. Clare, "Experimental validation of a space vector modulation algorithm for four-leg matrix converters," IEEE Trans. Ind. Electron., vol. 58, no. 4, pp. 1282-1293, Apr. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.4 , pp. 1282-1293
    • Cardenas, R.1    Pena, R.2    Wheeler, P.3    Clare, J.4
  • 110
    • 84863281386 scopus 로고    scopus 로고
    • Operation of wind-turbine-driven DFIG systems under distorted grid voltage conditions: Analysis and experimental validations
    • May
    • H. Xu, J. Hu, and Y. He, "Operation of wind-turbine-driven DFIG systems under distorted grid voltage conditions: Analysis and experimental validations," IEEE Trans. Power Electron., vol. 27, no. 5, pp. 2354-2366, May 2012.
    • (2012) IEEE Trans. Power Electron. , vol.27 , Issue.5 , pp. 2354-2366
    • Xu, H.1    Hu, J.2    He, Y.3
  • 111
    • 73849090195 scopus 로고    scopus 로고
    • Coordinated control of DFIG and FSIG-based wind farms under unbalanced grid conditions
    • Jan
    • Y. Wang and L. Xu, "Coordinated control of DFIG and FSIG-based wind farms under unbalanced grid conditions," IEEE Trans. Power Del., vol. 25, no. 1, pp. 367-377, Jan. 2010.
    • (2010) IEEE Trans. Power Del. , vol.25 , Issue.1 , pp. 367-377
    • Wang, Y.1    Xu, L.2
  • 112
    • 72949097448 scopus 로고    scopus 로고
    • Improved direct power control of a DFIGbased wind turbine during network unbalance
    • Nov
    • P. Zhou, Y. He, and D. Sun, "Improved direct power control of a DFIGbased wind turbine during network unbalance," IEEE Trans. Power Electron., vol. 24, no. 11, pp. 2465-2474, Nov. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.11 , pp. 2465-2474
    • Zhou, P.1    He, Y.2    Sun, D.3
  • 113
    • 0036957414 scopus 로고    scopus 로고
    • Vector control of a diesel-driven doubly fed induction machine for a stand-alone variable speed energy system
    • R. Pena, R. Cardenas, G. M. Asher, J. C. Clare, J. Rodriguez, and P. Cortes, "Vector control of a diesel-driven doubly fed induction machine for a stand-alone variable speed energy system," in Proc. 28th Annu. IEEE IECON, 2002, vol. 2, pp. 985-990.
    • (2002) Proc. 28th Annu. IEEE IECON , vol.2 , pp. 985-990
    • Pena, R.1    Cardenas, R.2    Asher, G.M.3    Clare, J.C.4    Rodriguez, J.5    Cortes, P.6
  • 114
    • 0036953931 scopus 로고    scopus 로고
    • Control strategy of doubly fed induction generators for a wind diesel energy system
    • R. Pena, R. Cardenas, J. Clare, and G. Asher, "Control strategy of doubly fed induction generators for a wind diesel energy system," in Proc. 28th Annu. IEEE IECON, 2002, vol. 4, pp. 3297-3302.
    • (2002) Proc. 28th Annu. IEEE IECON , vol.4 , pp. 3297-3302
    • Pena, R.1    Cardenas, R.2    Clare, J.3    Asher, G.4
  • 115
    • 29244453235 scopus 로고    scopus 로고
    • MRAS observer for sensorless control of standalone doubly fed induction generators
    • DOI 10.1109/TEC.2005.847965
    • R. Cardenas, R. Pena, J. Proboste, G. Asher, and J. Clare, "MRAS observer for sensorless control of standalone doubly fed induction generators," IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 710-718, Dec. 2005. (Pubitemid 41830046)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.4 , pp. 710-718
    • Cardenas, R.1    Pena, R.2    Proboste, J.3    Asher, G.4    Clare, J.5
  • 116
    • 84860190704 scopus 로고    scopus 로고
    • Sensorless starting of a wound-field synchronous starter/generator for aerospace applications
    • Sep
    • A. Griffo, D. Drury, T. Sawata, and P. H. Mellor, "Sensorless starting of a wound-field synchronous starter/generator for aerospace applications," IEEE Trans. Ind. Electron., vol. 59, no. 9, pp. 3579-3587, Sep. 2012.
    • (2012) IEEE Trans. Ind. Electron. , vol.59 , Issue.9 , pp. 3579-3587
    • Griffo, A.1    Drury, D.2    Sawata, T.3    Mellor, P.H.4
  • 117
    • 0242580903 scopus 로고    scopus 로고
    • A sensorless Integrated Doubly-Fed Electric Alternator/Active filter (IDEA) for variable speed wind energy system
    • M. Abolhassani, P. Niazi, H. Tolivat, and P. Enjeti, "A sensorless Integrated Doubly-Fed Electric Alternator/Active filter (IDEA) for variable speed wind energy system," in Conf. Rec. 38th IEEE IAS Annu. Meeting, 2003, pp. 507-514.
    • (2003) Conf. Rec. 38th IEEE IAS Annu. Meeting , pp. 507-514
    • Abolhassani, M.1    Niazi, P.2    Tolivat, H.3    Enjeti, P.4
  • 118
    • 0035421985 scopus 로고    scopus 로고
    • A simple position-sensorless algorithm for rotor-side field-oriented control of wound-rotor induction machine
    • DOI 10.1109/41.937411, PII S0278004601062803
    • R. Datta and V. T. Ranganathan, "A simple position-sensorless algorithm for rotor-side field-oriented control of wound-rotor induction machine," IEEE Trans. Ind. Electron., vol. 48, no. 4, pp. 786-793, Aug. 2001. (Pubitemid 32780047)
    • (2001) IEEE Transactions on Industrial Electronics , vol.48 , Issue.4 , pp. 786-793
    • Datta, R.1    Ranganathan, V.T.2
  • 119
    • 0032114643 scopus 로고    scopus 로고
    • Double-fed induction machine: Converter optimisation and field oriented control without position sensor
    • L. Morel, H. Godfroid, A. Mirzaian, and J. M. Kauffmann, "Doublefed induction machine: Converter optimisation and field oriented control without position sensor," Proc. Inst. Elect. Eng.-Elect. Power Appl., vol. 145, no. 4, pp. 360-368, Jul. 1998. (Pubitemid 128728086)
    • (1998) IEE Proceedings: Electric Power Applications , vol.145 , Issue.4 , pp. 360-368
    • Morel, L.1    Godfroid, H.2    Mirzaian, A.3    Kauffmann, J.M.4
  • 120
    • 76249085156 scopus 로고    scopus 로고
    • Sensorless control of a double-fed machine for wind power generators
    • Dubrovnik and Cavtat, Croatia, [CD-ROM]
    • E. Bogalecka and Z. Krzeminski, "Sensorless control of a double-fed machine for wind power generators," in Proc. EPE-PMC, Dubrovnik and Cavtat, Croatia, 2002, [CD-ROM].
    • (2002) Proc. EPE-PMC
    • Bogalecka, E.1    Krzeminski, Z.2
  • 121
    • 0034228293 scopus 로고    scopus 로고
    • Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder
    • Jul
    • B. Hopfensperger, D. J. Atkinson, and R. A. Lakin, "Stator-flux- oriented control of a doubly-fed induction machine with and without position encoder," Proc. Inst. Elect. Eng.-Elect. Power Appl., vol. 147, no. 4, pp. 241-250, Jul. 2000.
    • (2000) Proc. Inst. Elect. Eng.-Elect. Power Appl. , vol.147 , Issue.4 , pp. 241-250
    • Hopfensperger, B.1    Atkinson, D.J.2    Lakin, R.A.3
  • 122
    • 20444498076 scopus 로고    scopus 로고
    • A novel sensorless control strategy of doubly fed induction motor and its examination with the physical modeling of machines
    • DOI 10.1109/TMAG.2005.846500
    • O. A. Mohammed, Z. Liu, and S. Liu, "A novel sensorless control strategy of doubly fed induction motor and its examination with the physical modeling of machines," IEEE Trans. Magn., vol. 41, no. 5, pp. 1852- 1855, May 2005. (Pubitemid 40963601)
    • (2005) IEEE Transactions on Magnetics , vol.41 , Issue.5 , pp. 1852-1855
    • Mohammed, O.A.1    Liu, Z.2    Liu, S.3
  • 123
    • 0029307617 scopus 로고
    • Torque and reactive power control of a doubly fed induction machine by position sensorless scheme
    • May/Jun
    • L. Xu and W. Cheng, "Torque and reactive power control of a doubly fed induction machine by position sensorless scheme," IEEE Trans. Ind. Appl., vol. 31, no. 3, pp. 636-642, May/Jun. 1995.
    • (1995) IEEE Trans. Ind. Appl. , vol.31 , Issue.3 , pp. 636-642
    • Xu, L.1    Cheng, W.2
  • 124
    • 0026923905 scopus 로고
    • Adaptive speed identification for vector control of induction motors without rotational transducers
    • DOI 10.1109/28.158829
    • C. Schauder, "Adaptive speed identification for vector control of induction motors without rotational transducers," IEEE Trans. Ind. Appl., vol. 28, no. 5, pp. 1054-1061, Sep./Oct. 1992. (Pubitemid 23555887)
    • (1992) IEEE Transactions on Industry Applications , vol.28 , Issue.5 , pp. 1054-1061
    • Schauder Colin1
  • 128
    • 3042683467 scopus 로고    scopus 로고
    • Rotor current based MRAS observer for doubly-fed induction machines
    • Jun
    • R. Cardenas, R. Pena, J. Proboste, G. Asher, and J. Clare, "Rotor current based MRAS observer for doubly-fed induction machines," Electron. Lett., vol. 40, no. 12, pp. 769-770, Jun. 2004.
    • (2004) Electron. Lett. , vol.40 , Issue.12 , pp. 769-770
    • Cardenas, R.1    Pena, R.2    Proboste, J.3    Asher, G.4    Clare, J.5
  • 129
    • 84857809774 scopus 로고    scopus 로고
    • Comparison of MRAS based speed estimation methods for a stand-alone doubly fed induction generator
    • M. Pattnaik and D. Kastha, "Comparison of MRAS based speed estimation methods for a stand-alone doubly fed induction generator," in Proc. ICEAS, 2011, pp. 1-6.
    • (2011) Proc. ICEAS , pp. 1-6
    • Pattnaik, M.1    Kastha, D.2
  • 130
    • 52349105824 scopus 로고    scopus 로고
    • A novel position sensor-less control scheme of Doubly Fed Induction Wind Generator based on MRAS method
    • Y. Guofeng, L. Yongdong, C. Jianyun, and J. Xinjian, "A novel position sensor-less control scheme of Doubly Fed Induction Wind Generator based on MRAS method," in Proc. IEEE PESC, 2008, pp. 2723-2727.
    • (2008) Proc. IEEE PESC , pp. 2723-2727
    • Guofeng, Y.1    Yongdong, L.2    Jianyun, C.3    Xinjian, J.4
  • 131
    • 78650377749 scopus 로고    scopus 로고
    • A MRAS observer applied to sensorless doubly fed induction machine drives
    • M. S. Carmeli, M. Iacchetti, and R. Perini, "A MRAS observer applied to sensorless doubly fed induction machine drives," in Proc. IEEE ISIE, 2010, vol. 1, pp. 3077-3082.
    • (2010) Proc. IEEE ISIE , vol.1 , pp. 3077-3082
    • Carmeli, M.S.1    Iacchetti, M.2    Perini, R.3
  • 132
    • 70349614159 scopus 로고    scopus 로고
    • Adaptive observer for sensorless control of stand-alone doubly fed induction generator
    • Oct
    • D. G. Forchetti, G. O. García, S. Member, and M. I. Valla, "Adaptive observer for sensorless control of stand-alone doubly fed induction generator," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4174-4180, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4174-4180
    • Forchetti, D.G.1    García, G.O.2    Member, S.3    Valla, M.I.4
  • 133
    • 44449156762 scopus 로고    scopus 로고
    • MRAS observers for sensorless control of doubly-fed induction generators
    • DOI 10.1109/TPEL.2008.921189
    • R. Cardenas, R. Pena, J. Clare, G. Asher, and J. Proboste, "MRAS observers for sensorless control of doubly-fed induction generators," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1075-1084, May 2008. (Pubitemid 351756684)
    • (2008) IEEE Transactions on Power Electronics , vol.23 , Issue.3 , pp. 1075-1084
    • Cardenas, R.1    Pena, R.2    Clare, J.3    Asher, G.4    Proboste, J.5
  • 135
    • 84858016049 scopus 로고    scopus 로고
    • An MRAS observer for sensorless DFIM drives with direct estimation of the torque and flux rotor current components
    • May
    • F. Castelli-Dezza, G. Foglia, M. F. Iacchetti, and R. Perini, "An MRAS observer for sensorless DFIM drives with direct estimation of the torque and flux rotor current components," IEEE Trans. Power Electron., vol. 27, no. 5, pp. 2576-2584, May 2012.
    • (2012) IEEE Trans. Power Electron. , vol.27 , Issue.5 , pp. 2576-2584
    • Castelli-Dezza, F.1    Foglia, G.2    Iacchetti, M.F.3    Perini, R.4
  • 137
    • 57849124252 scopus 로고    scopus 로고
    • Sensorless control of standalone doubly fed induction generator with an adaptive observer
    • D. Forchetti, G. O. Garcia, and M. I. Valla, "Sensorless control of standalone doubly fed induction generator with an adaptive observer," in Proc. IEEE ISIE, 2008, pp. 2444-2449.
    • (2008) Proc. IEEE ISIE , pp. 2444-2449
    • Forchetti, D.1    Garcia, G.O.2    Valla, M.I.3
  • 138
    • 32644442892 scopus 로고    scopus 로고
    • Comparative analysis of experimental performance and stability of sensorless induction motor drives
    • Feb
    • K. Ohyama, G. Asher, and M. Sumner, "Comparative analysis of experimental performance and stability of sensorless induction motor drives," IEEE Trans. Ind. Electron., vol. 53, no. 1, pp. 178-186, Feb. 2005.
    • (2005) IEEE Trans. Ind. Electron. , vol.53 , Issue.1 , pp. 178-186
    • Ohyama, K.1    Asher, G.2    Sumner, M.3
  • 139
    • 80052348041 scopus 로고    scopus 로고
    • Adaptive tuning of the stator inductance in a rotorcurrent- based MRAS observer for sensorless doubly fed inductionmachine drives
    • Oct
    • M. F. Iacchetti, "Adaptive tuning of the stator inductance in a rotorcurrent- based MRAS observer for sensorless doubly fed inductionmachine drives," IEEE Trans. Ind. Electron., vol. 58, no. 10, pp. 4683- 4692, Oct. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.10 , pp. 4683-4692
    • Iacchetti, M.F.1
  • 140
    • 79951618591 scopus 로고    scopus 로고
    • Effects of mismatched parameters in MRAS sensorless doubly fed induction machine drives
    • Nov
    • M. S. Carmeli, F. Castelli-dezza, M. Iacchetti, and R. Perini, "Effects of mismatched parameters in MRAS sensorless doubly fed induction machine drives," IEEE Trans. Power Electron., vol. 25, no. 11, pp. 2842- 2851, Nov. 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.11 , pp. 2842-2851
    • Carmeli, M.S.1    Castelli-Dezza, F.2    Iacchetti, M.3    Perini, R.4
  • 141
    • 70049110358 scopus 로고    scopus 로고
    • Rotor position phase-locked loop for decoupled P-Q control of DFIG for wind power generation
    • Sep
    • B. Mwinyiwiwa, Y. Zhang, B. Shen, and B.-T. Ooi, "Rotor position phase-locked loop for decoupled P-Q control of DFIG for wind power generation," IEEE Trans. Energy Convers., vol. 24, no. 3, pp. 758-765, Sep. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.3 , pp. 758-765
    • Mwinyiwiwa, B.1    Zhang, Y.2    Shen, B.3    Ooi, B.-T.4
  • 142
    • 67349112843 scopus 로고    scopus 로고
    • Sensorless maximum power point tracking of wind by DFIG using rotor Position Phase Lock Loop (PLL)
    • Apr
    • B. Shen, B. Mwinyiwiwa, Y. Zhang, and B.-T. Ooi, "Sensorless maximum power point tracking of wind by DFIG using rotor Position Phase Lock Loop (PLL)," IEEE Trans. Power Electron., vol. 24, no. 4, pp. 942- 951, Apr. 2009.
    • (2009) IEEE Trans. Power Electron. , vol.24 , Issue.4 , pp. 942-951
    • Shen, B.1    Mwinyiwiwa, B.2    Zhang, Y.3    Ooi, B.-T.4
  • 143
    • 49249131011 scopus 로고    scopus 로고
    • Design of a robust speed and position sensorless decoupled P-Q controlled doubly-fed induction generator for variable-speed wind energy applications
    • K. Gogas, G. Joos, B. T. Ooi, Y. Z. Zhang, and B. Mwinyiwiwa, "Design of a robust speed and position sensorless decoupled P-Q controlled doubly-fed induction generator for variable-speed wind energy applications," in Proc. IEEE Canada EPC, 2007, pp. 62-67.
    • (2007) Proc. IEEE Canada EPC , pp. 62-67
    • Gogas, K.1    Joos, G.2    Ooi, B.T.3    Zhang, Y.Z.4    Mwinyiwiwa, B.5
  • 144
    • 80052378723 scopus 로고    scopus 로고
    • Air-gap-power-vector-based sensorless method for DFIG control without flux estimator
    • Oct
    • G. D. Marques and D. M. Sousa, "Air-gap-power-vector-based sensorless method for DFIG control without flux estimator," IEEE Trans. Ind. Electron., vol. 58, no. 10, pp. 4717-4726, Oct. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.10 , pp. 4717-4726
    • Marques, G.D.1    Sousa, D.M.2
  • 146
    • 79951955124 scopus 로고    scopus 로고
    • A DFIG sensorless rotor-position detector based on a hysteresis controller
    • Mar
    • G. D. Marques, V. F. Pires, S. Sousa, and D. M. Sousa, "A DFIG sensorless rotor-position detector based on a hysteresis controller," IEEE Trans. Energy Convers., vol. 26, no. 1, pp. 9-17, Mar. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.1 , pp. 9-17
    • Marques, G.D.1    Pires, V.F.2    Sousa, S.3    Sousa, D.M.4
  • 149
    • 32644431559 scopus 로고    scopus 로고
    • Sensorless control of induction machines; With or without signal injection?
    • Feb
    • J. Holtz, "Sensorless control of induction machines; With or without signal injection?" IEEE Trans. Ind. Electron., vol. 53, no. 1, pp. 7-30, Feb. 2005.
    • (2005) IEEE Trans. Ind. Electron. , vol.53 , Issue.1 , pp. 7-30
    • Holtz, J.1
  • 150
    • 34548266685 scopus 로고    scopus 로고
    • Estimation of wind penetration as limited by frequency deviation
    • DOI 10.1109/TEC.2006.881082
    • C. Luo, H. G. Far, H. Banakar, P. Keung, B. Ooi, and L. Fellow, "Estimation of wind penetration as limited by frequency deviation," IEEE Trans. Energy Convers., vol. 22, no. 3, pp. 783-791, Sep. 2007. (Pubitemid 47323594)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.3 , pp. 783-791
    • Luo, C.1    Far, H.G.2    Banakar, H.3    Keung, P.-K.4    Ooi, B.-T.5
  • 151
    • 39749190182 scopus 로고    scopus 로고
    • Impacts of wind power minute-to-minute variations on power system operation
    • DOI 10.1109/TPWRS.2007.913298
    • H. Banakar, C. Luo, B. T. Ooi, L. Fellow, A. A. G. C. Feedback, and L. Time, "Impacts of wind power minute-to-minute variations on power system operation," IEEE Trans. Power Syst., vol. 23, no. 1, pp. 150-160, Feb. 2008. (Pubitemid 351292099)
    • (2008) IEEE Transactions on Power Systems , vol.23 , Issue.1 , pp. 150-160
    • Banakar, H.1    Luo, C.2    Ooi, B.T.3
  • 152
    • 33947368592 scopus 로고    scopus 로고
    • Frequency deviation of thermal power plants due to wind farms
    • DOI 10.1109/TEC.2006.874210
    • C. Luo, S. Member, B. Ooi, and L. Fellow, "Frequency deviation of thermal power plants due to wind farms," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 708-716, Sep. 2006. (Pubitemid 46445159)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 708-716
    • Luo, C.1    Ooi, B.-T.2
  • 153
    • 84863115500 scopus 로고    scopus 로고
    • Coordinated frequency regulation by doubly fed induction generator-based wind power plants
    • Jan
    • Z.-S. Zhang, Y.-Z. Sun, J. Lin, and G.-J. Li, "Coordinated frequency regulation by doubly fed induction generator-based wind power plants," IET Renew. Power Gen., vol. 6, no. 1, pp. 38-47, Jan. 2012.
    • (2012) IET Renew. Power Gen. , vol.6 , Issue.1 , pp. 38-47
    • Zhang, Z.-S.1    Sun, Y.-Z.2    Lin, J.3    Li, G.-J.4
  • 154
    • 78751483312 scopus 로고    scopus 로고
    • Control of DFIG-based wind farms for power network frequency support
    • X. Zhang, H. Li, and Y. Wang, "Control of DFIG-based wind farms for power network frequency support," in Proc. Int. Conf. POWERCON, 2010, pp. 1-6.
    • (2010) Proc. Int. Conf. POWERCON , pp. 1-6
    • Zhang, X.1    Li, H.2    Wang, Y.3
  • 155
    • 32144457162 scopus 로고    scopus 로고
    • Wind turbines emulating inertia and supporting primary frequency control
    • DOI 10.1109/TPWRS.2005.861956
    • J. Morren, S. W. H. de Haan, W. L. Kling, and J. A. Ferreira, "Wind turbines emulating inertia and supporting primary frequency control," IEEE Trans. Power Syst., vol. 21, no. 1, pp. 433-434, Feb. 2006. (Pubitemid 43204745)
    • (2006) IEEE Transactions on Power Systems , vol.21 , Issue.1 , pp. 433-434
    • Morren, J.1    De Haan, S.W.H.2    Kling, W.L.3    Ferreira, J.A.4
  • 156
    • 70349579256 scopus 로고    scopus 로고
    • A review of grid code technical requirements for wind farms
    • Sep
    • M. Tsili and S. Papathanassiou, "A review of grid code technical requirements for wind farms," IET Renew. Power Gen., vol. 3, no. 3, pp. 308- 332, Sep. 2009.
    • (2009) IET Renew. Power Gen. , vol.3 , Issue.3 , pp. 308-332
    • Tsili, M.1    Papathanassiou, S.2
  • 158
    • 24944534558 scopus 로고    scopus 로고
    • The inertial response of induction-machine-based wind turbines
    • DOI 10.1109/TPWRS.2005.852081
    • A. Mullane and M. OMalley, "The inertial response of inductionmachine- based wind turbines," IEEE Trans. Power Syst., vol. 20, no. 3, pp. 1496-1503, Aug. 2005. (Pubitemid 41300963)
    • (2005) IEEE Transactions on Power Systems , vol.20 , Issue.3 , pp. 1496-1503
    • Mullane, A.1    O'Malley, M.2
  • 159
    • 80052051489 scopus 로고    scopus 로고
    • Novel integration of DFIG-based wind generators within microgrids
    • Sep
    • M. Fazeli, G. M. Asher, C. Klumpner, and L. Yao, "Novel integration of DFIG-based wind generators within microgrids," IEEE Trans. Energy Convers., vol. 26, no. 3, pp. 840-850, Sep. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.3 , pp. 840-850
    • Fazeli, M.1    Asher, G.M.2    Klumpner, C.3    Yao, L.4
  • 160
    • 79958797977 scopus 로고    scopus 로고
    • Improved inertia and frequency support from grid-connected DFIG wind farms
    • I. A. Gowaid, A. El-Zawawi, and M. El-Gammal, "Improved inertia and frequency support from grid-connected DFIG wind farms," in Proc. IEEE/PES PSCE, 2011, pp. 1-9.
    • (2011) Proc. IEEE/PES PSCE , pp. 1-9
    • Gowaid, I.A.1    El-Zawawi, A.2    El-Gammal, M.3
  • 161
    • 67349262621 scopus 로고    scopus 로고
    • Dynamic contribution of DFIG-based wind plants to system frequency disturbances
    • May
    • M. Kayikci and J. V. Milanovic, "Dynamic contribution of DFIG-based wind plants to system frequency disturbances," IEEE Trans. Power Syst., vol. 24, no. 2, pp. 859-867, May 2009.
    • (2009) IEEE Trans. Power Syst. , vol.24 , Issue.2 , pp. 859-867
    • Kayikci, M.1    Milanovic, J.V.2
  • 163
    • 84863049563 scopus 로고    scopus 로고
    • Virtual inertia control of DFIG-based wind turbines for dynamic grid frequency support
    • X. Zhu, Y. Wang, L. Xu, X. Zhang, and H. Li, "Virtual inertia control of DFIG-based wind turbines for dynamic grid frequency support," in Proc. IET Conf. RPG, 2011, pp. 1-6.
    • (2011) Proc. IET Conf. RPG , pp. 1-6
    • Zhu, X.1    Wang, Y.2    Xu, L.3    Zhang, X.4    Li, H.5
  • 164
    • 28244480269 scopus 로고    scopus 로고
    • Control of DFIG-based wind generation for power network support
    • DOI 10.1109/TPWRS.2005.857275
    • F. M. Hughes, O. Anaya-lara, N. Jenkins, and G. Strbac, "Control of DFIG-based wind generation for power network support," IEEE Trans. Power Syst., vol. 20, no. 4, pp. 1958-1966, Nov. 2005. (Pubitemid 41700549)
    • (2005) IEEE Transactions on Power Systems , vol.20 , Issue.4 , pp. 1958-1966
    • Hughes, F.M.1    Anaya-Lara, O.2    Jenkins, N.3    Strbac, G.4
  • 165
    • 79151479221 scopus 로고    scopus 로고
    • Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems
    • Feb
    • D. Gautam, S. Member, L. Goel, R. Ayyanar, and S. Member, "Control strategy to mitigate the impact of reduced inertia due to doubly fed induction generators on large power systems," IEEE Trans. Power Syst., vol. 26, no. 1, pp. 214-224, Feb. 2011.
    • (2011) IEEE Trans. Power Syst. , vol.26 , Issue.1 , pp. 214-224
    • Gautam, D.1    Member, S.2    Goel, L.3    Ayyanar, R.4    Member, S.5
  • 166
    • 34247185867 scopus 로고    scopus 로고
    • Frequency support from doubly fed induction generator wind turbines
    • DOI 10.1049/iet-rpg:20060019
    • G. Ramtharan, J. B. Ekanayake, and N. Jenkins, "Frequency support from doubly fed induction generator wind turbines," IET Renew. Power Gen., vol. 1, no. 1, pp. 3-9, Mar. 2007. (Pubitemid 46610162)
    • (2007) IET Renewable Power Generation , vol.1 , Issue.1 , pp. 3-9
    • Ramtharan, G.1    Ekanayake, J.B.2    Jenkins, N.3
  • 167
    • 79955541414 scopus 로고    scopus 로고
    • Enhancing frequency response control by DFIGs in the high wind penetrated power systems
    • May
    • L.-R. Chang-Chien, W.-T. Lin, and Y.-C. Yin, "Enhancing frequency response control by DFIGs in the high wind penetrated power systems," IEEE Trans. Power Syst., vol. 26, no. 2, pp. 710-718, May 2011.
    • (2011) IEEE Trans. Power Syst. , vol.26 , Issue.2 , pp. 710-718
    • Chang-Chien, L.-R.1    Lin, W.-T.2    Yin, Y.-C.3
  • 169
    • 70849107847 scopus 로고    scopus 로고
    • Strategies for operating wind power in a similar manner of conventional power plant
    • Dec
    • L.-R. Chang-Chien and Y. Yin, "Strategies for operating wind power in a similar manner of conventional power plant," IEEE Trans. Energy Convers., vol. 24, no. 4, pp. 926-934, Dec. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.4 , pp. 926-934
    • Chang-Chien, L.-R.1    Yin, Y.2
  • 170
    • 81855209857 scopus 로고    scopus 로고
    • Assessment of inertial potential of variablespeed wind turbines
    • S. El Itani and G. Joos, "Assessment of inertial potential of variablespeed wind turbines," in Proc. IEEE ECCE, 2011, pp. 851-856.
    • (2011) Proc. IEEE ECCE , pp. 851-856
    • El Itani, S.1    Joos, G.2
  • 171
    • 34249775795 scopus 로고    scopus 로고
    • Strategies to smooth wind power fluctuations of wind turbine generator
    • DOI 10.1109/TEC.2007.895401
    • C. Luo, H. Banakar, B. Shen, and B. Ooi, "Strategies to smooth wind power fluctuations of wind turbine generator," IEEE Trans. Energy Convers., vol. 22, no. 2, pp. 341-349, Jun. 2007. (Pubitemid 46845632)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.2 , pp. 341-349
    • Luo, C.1    Banakar, H.2    Shen, B.3    Ooi, B.-T.4
  • 172
    • 84861862847 scopus 로고    scopus 로고
    • Novel integration of wind generator-energy storage systems within microgrids
    • Jun
    • M. Fazeli, G. M. Asher, C. Klumpner, L. Yao, and M. Bazargan, "Novel integration of wind generator-energy storage systems within microgrids," IEEE Trans. Smart Grid, vol. 3, no. 2, pp. 728-737, Jun. 2012.
    • (2012) IEEE Trans. Smart Grid , vol.3 , Issue.2 , pp. 728-737
    • Fazeli, M.1    Asher, G.M.2    Klumpner, C.3    Yao, L.4    Bazargan, M.5
  • 173
    • 72949094730 scopus 로고    scopus 로고
    • Wind turbine-energy storage control system for delivering constant demand power shared by DFIGs through droop characteristics
    • M. Fazeli, G. M. Asher, C. Klumpner, S. Bozhko, L. Yao, and M. Bazargan, "Wind turbine-energy storage control system for delivering constant demand power shared by DFIGs through droop characteristics," in Proc. 13th Eur. Conf. EPE Appl., 2009, pp. 1-10.
    • (2009) Proc. 13th Eur. Conf. EPE Appl. , pp. 1-10
    • Fazeli, M.1    Asher, G.M.2    Klumpner, C.3    Bozhko, S.4    Yao, L.5    Bazargan, M.6
  • 174
    • 61649085846 scopus 로고    scopus 로고
    • Microgrid dynamic performance improvement using a doubly fed induction wind generator
    • Mar
    • M. Shahabi, S. Member, M. R. Haghifam, S. Member, and M. Mohamadian, "Microgrid dynamic performance improvement using a doubly fed induction wind generator," IEEE Trans. Energy Convers., vol. 24, no. 1, pp. 137-145, Mar. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.1 , pp. 137-145
    • Shahabi, M.1    Member, S.2    Haghifam, M.R.3    Member, S.4    Mohamadian, M.5
  • 175
    • 84874824198 scopus 로고    scopus 로고
    • Wind energy barometer 2011
    • Feb
    • "Wind energy barometer 2011," Systemes Solaires - Le Journal de l'Éolien, vol. 10, no. 8, pp. 80-107, Feb. 2011.
    • (2011) Systemes Solaires-Le Journal de l'Éolien , vol.10 , Issue.8 , pp. 80-107
  • 176
    • 84874909140 scopus 로고    scopus 로고
    • Red Eléctrica, last accessed Feb. [Online]
    • Red Eléctrica, "The Spanish Electricity System. Summary 2008," last accessed Feb. 2013. [Online]. Available: http://www.ree.es/ ingles/sistema-electrico/informeSEE-2008.asp
    • (2013) The Spanish Electricity System. Summary 2008
  • 177
    • 84874909140 scopus 로고    scopus 로고
    • Red Eléctrica, last accessed Feb. [Online]
    • Red Eléctrica, "The Spanish Electricity System. Summary 2009," last accessed Feb. 2013. [Online]. Available: http://www.ree.es/ ingles/sistema-electrico/informeSEE-2009.asp
    • (2013) The Spanish Electricity System. Summary 2009
  • 178
    • 84874909140 scopus 로고    scopus 로고
    • Red Eléctrica, last accessed Feb. [Online]
    • Red Eléctrica, "The Spanish Electricity System. Summary 2010," last accessed Feb. 2013. [Online]. Available: http://www.ree.es/ ingles/sistema-electrico/informeSEE-2010.asp
    • (2013) The Spanish Electricity System. Summary 2010
  • 179
    • 84874887685 scopus 로고    scopus 로고
    • Red Eléctrica, last accessed Feb. [Online]
    • Red Eléctrica, "Press release: Record share of wind energy in demand coverage," last accessed Feb. 2013. [Online]. Available: http://www.ree.es/ingles/sala-prensa/web/notas-detalle.aspx?id-nota=255
    • (2013) Press Release: Record Share of Wind Energy in Demand Coverage
  • 181
    • 33750109723 scopus 로고    scopus 로고
    • Overview of control and grid synchronization for distributed power generation systems
    • DOI 10.1109/TIE.2006.881997
    • F. Blaabjerg, R. Teodorescu, M. Liserre, and A. V. Timbus, "Overview of control and grid synchronization for distributed power generation systems," IEEE Trans. Ind. Electron., vol. 53, no. 5, pp. 1398-1409, Oct. 2006. (Pubitemid 44593490)
    • (2006) IEEE Transactions on Industrial Electronics , vol.53 , Issue.5 , pp. 1398-1409
    • Blaabjerg, F.1    Teodorescu, R.2    Liserre, M.3    Timbus, A.V.4
  • 182
    • 34548274089 scopus 로고    scopus 로고
    • Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    • DOI 10.1109/TEC.2006.878241
    • J. Lopez, P. Sanchis, X. Roboam, and L. Marroyo, "Dynamic behavior of the doubly fed induction generator during three-phase voltage dips," IEEE Trans. Energy Convers., vol. 22, no. 3, pp. 709-717, Sep. 2007. (Pubitemid 47323587)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.3 , pp. 709-717
    • Lopez, J.1    Sanchis, P.2    Roboam, X.3    Marroyo, L.4
  • 184
    • 80053462586 scopus 로고    scopus 로고
    • www.energynet.dk, Energinet. Last accessed Feb. 2013. [Online]
    • Energinet, "Technical regulation 3.2.5 for wind power plants with a power output greater than 11 kW," 2010. Last accessed Feb. 2013. [Online]. Available: www.energynet.dk; http://www.energinet.dk/EN/El/Forskrifter/ Technical-regulations/Sider/Regulations-for-gridconnection.aspx
    • (2010) Technical Regulation 3.2.5 for Wind Power Plants with A Power Output Greater Than 11 KW
  • 185
    • 35348829148 scopus 로고    scopus 로고
    • Advanced grid requirements for the integration of wind turbines into the German transmission system
    • I. Erlich, W. Winter, and A. Dittrich, "Advanced grid requirements for the integration of wind turbines into the German transmission system," in Proc. IEEE Power Eng. Soc. Gen. Meeting, 2006, p. 7.
    • (2006) Proc. IEEE Power Eng. Soc. Gen. Meeting , pp. 7
    • Erlich, I.1    Winter, W.2    Dittrich, A.3
  • 186
    • 33947430524 scopus 로고    scopus 로고
    • Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    • DOI 10.1109/TEC.2006.875783
    • X. Dawei, R. Li, P. J. Tavner, and S. Yang, "Control of a doubly fed induction generator in a wind turbine during grid fault ridethrough," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 652-662, Sep. 2006. (Pubitemid 46445154)
    • (2006) IEEE Transactions on Energy Conversion , vol.21 , Issue.3 , pp. 652-662
    • Xiang, D.1    Ran, L.2    Tavner, P.J.3    Yang, S.4
  • 187
    • 80053064904 scopus 로고    scopus 로고
    • Impacts of symmetrical and asymmetrical voltage sags on DFIG-based wind turbines considering phase-angle jump, voltage recovery, and sag parameters
    • May
    • M. Mohseni, S. M. Islam, and M. A. S. Masoum, "Impacts of symmetrical and asymmetrical voltage sags on DFIG-based wind turbines considering phase-angle jump, voltage recovery, and sag parameters," IEEE Trans. Power Electron., vol. 26, no. 5, pp. 1587-1598, May 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.5 , pp. 1587-1598
    • Mohseni, M.1    Islam, S.M.2    Masoum, M.A.S.3
  • 188
    • 83455202755 scopus 로고    scopus 로고
    • An improved low-voltage ridethrough control strategy of doubly fed induction generator during grid faults
    • Dec
    • S. Hu, X. Lin, Y. Kang, and X. Zou, "An improved low-voltage ridethrough control strategy of doubly fed induction generator during grid faults," IEEE Trans. Power Electron., vol. 26, no. 12, pp. 3653-3665, Dec. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.12 , pp. 3653-3665
    • Hu, S.1    Lin, X.2    Kang, Y.3    Zou, X.4
  • 191
    • 40849141184 scopus 로고    scopus 로고
    • Wind turbines based on doubly fed induction generator under asymmetrical voltage dips
    • DOI 10.1109/TEC.2007.914317
    • J. Lopez, E. Gubia, P. Sanchis, X. Roboam, and L. Marroyo, "Wind turbines based on doubly fed induction generator under asymmetrical voltage dips," IEEE Trans. Energy Convers., vol. 23, no. 1, pp. 321-330, Mar. 2008. (Pubitemid 351392328)
    • (2008) IEEE Transactions on Energy Conversion , vol.23 , Issue.1 , pp. 321-330
    • Lopez, J.1    Gubia, E.2    Sanchis, P.3    Roboam, X.4    Marroyo, L.5
  • 193
    • 33947634098 scopus 로고    scopus 로고
    • Short-circuit current of wind turbines with doubly fed induction generator
    • DOI 10.1109/TEC.2006.889615, Special Issue on Wind Power
    • J. Morren and S. W. H. de Haan, "Short-circuit current of wind turbines with doubly fed induction generator," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 174-180, Mar. 2007. (Pubitemid 46487490)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.1 , pp. 174-180
    • Morren, J.1    De Haan, S.W.2
  • 194
    • 48449098817 scopus 로고    scopus 로고
    • An improved fault ride-through strategy for doubly fed induction generator-based wind turbines
    • Dec
    • A. H. Kasem, E. F. El-Saadany, H. H. El-Tamaly, and M. A. A. Wahab, "An improved fault ride-through strategy for doubly fed induction generator-based wind turbines," IET Renew. Power Gen., vol. 2, no. 4, pp. 201-214, Dec. 2008.
    • (2008) IET Renew. Power Gen. , vol.2 , Issue.4 , pp. 201-214
    • Kasem, A.H.1    El-Saadany, E.F.2    El-Tamaly, H.H.3    Wahab, M.A.A.4
  • 195
    • 77949897659 scopus 로고    scopus 로고
    • Effects of voltage unbalance and system harmonics on the performance of doubly fed induction wind generators
    • Mar./Apr
    • M. Kiani, "Effects of voltage unbalance and system harmonics on the performance of doubly fed induction wind generators," IEEE Trans. Ind. Appl., vol. 46, no. 2, pp. 562-568, Mar./Apr. 2010.
    • (2010) IEEE Trans. Ind. Appl. , vol.46 , Issue.2 , pp. 562-568
    • Kiani, M.1
  • 196
    • 84873374990 scopus 로고    scopus 로고
    • Use of stored energy in PMSG rotor inertia for low voltage ride-through in back-to-back NPC converter based wind power systems
    • May
    • S. Alepuz, A. Calle-Prado, S. Busquets-Monge, S. Kouro, and B. Wu, "Use of stored energy in PMSG rotor inertia for low voltage ride-through in back-to-back NPC converter based wind power systems," IEEE Trans. Ind. Electron., vol. 60, no. 5, pp. 1787-1796, May 2013.
    • (2013) IEEE Trans. Ind. Electron. , vol.60 , Issue.5 , pp. 1787-1796
    • Alepuz, S.1    Calle-Prado, A.2    Busquets-Monge, S.3    Kouro, S.4    Wu, B.5
  • 198
    • 22044432503 scopus 로고    scopus 로고
    • Voltage dip ride through of a double-fed generator equipped with an active crowbar
    • N. Jouko, "Voltage dip ride through of a double-fed generator equipped with an active crowbar," in Proc. Nordic Wind Power Conf., 2004, pp. 1409-1415.
    • (2004) Proc. Nordic Wind Power Conf. , pp. 1409-1415
    • Jouko, N.1
  • 199
    • 29244448716 scopus 로고    scopus 로고
    • Modeling and experimental verification of grid interaction of a DFIG wind turbine
    • DOI 10.1109/TEC.2005.853750
    • A. Petersson, T. Thiringer, L. Harnefors, and T. Petru, "Modeling and experimental verification of grid interaction of a DFIG wind turbine," IEEE Trans. Energy Convers., vol. 20, no. 4, pp. 878-886, Dec. 2005. (Pubitemid 41830065)
    • (2005) IEEE Transactions on Energy Conversion , vol.20 , Issue.4 , pp. 878-886
    • Petersson, A.1    Thiringer, T.2    Harnefors, L.3    Petru, T.4
  • 200
    • 44449131797 scopus 로고    scopus 로고
    • An improved control strategy of limiting the DC-link voltage fluctuation for a doubly fed induction wind generator
    • May
    • Y. Jun, L. Hui, L. Yong, and C. Zhe, "An improved control strategy of limiting the DC-link voltage fluctuation for a doubly fed induction wind generator," IEEE Trans. Power Electron., vol. 23, no. 3, pp. 1205-1213, May 2008.
    • (2008) IEEE Trans. Power Electron. , vol.23 , Issue.3 , pp. 1205-1213
    • Jun, Y.1    Hui, L.2    Yong, L.3    Zhe, C.4
  • 201
    • 77957347759 scopus 로고    scopus 로고
    • DFIG wind generation systems operating with limited converter rating considered under unbalanced network conditions - Analysis and control design
    • Feb
    • J. Hu and Y. He, "DFIG wind generation systems operating with limited converter rating considered under unbalanced network conditions - analysis and control design," Renew. Energy, vol. 36, no. 2, pp. 829-847, Feb. 2011.
    • (2011) Renew. Energy , vol.36 , Issue.2 , pp. 829-847
    • Hu, J.1    He, Y.2
  • 203
    • 78649601158 scopus 로고    scopus 로고
    • Protection system behavior of DFIG based wind farms for grid-faults with practical considerations
    • T. Kawady, C. Feltes, I. Erlich, and A. I. Taalab, "Protection system behavior of DFIG based wind farms for grid-faults with practical considerations," in Proc. IEEE PES Gen. Meeting, 2010, pp. 1-6.
    • (2010) Proc. IEEE PES Gen. Meeting , pp. 1-6
    • Kawady, T.1    Feltes, C.2    Erlich, I.3    Taalab, A.I.4
  • 204
    • 77957014951 scopus 로고    scopus 로고
    • Decoupled-DFIG fault ride-through strategy for enhanced stability performance during grid faults
    • Oct
    • L. G. Meegahapola, T. Littler, and D. Flynn, "Decoupled-DFIG fault ride-through strategy for enhanced stability performance during grid faults," IEEE Trans. Sustain. Energy, vol. 1, no. 3, pp. 152-132, Oct. 2010.
    • (2010) IEEE Trans. Sustain. Energy , vol.1 , Issue.3 , pp. 152-132
    • Meegahapola, L.G.1    Littler, T.2    Flynn, D.3
  • 206
    • 79958011415 scopus 로고    scopus 로고
    • Participation of facts in stabilizing DFIG with crowbar during grid fault based on grid codes
    • K. E. Okedu, S. M. Muyeen, R. Takahashi, and J. Tamura, "Participation of facts in stabilizing DFIG with crowbar during grid fault based on grid codes," in Proc. IEEE GCC Conf. Exhib., 2011, pp. 365-368.
    • (2011) Proc. IEEE GCC Conf. Exhib. , pp. 365-368
    • Okedu, K.E.1    Muyeen, S.M.2    Takahashi, R.3    Tamura, J.4
  • 207
    • 77952258105 scopus 로고    scopus 로고
    • STATCOM-based indirect torque control of induction machines during voltage recovery after grid faults
    • May
    • J. A. Suul, M. Molinas, and T. Undeland, "STATCOM-based indirect torque control of induction machines during voltage recovery after grid faults," IEEE Trans. Power Electron., vol. 25, no. 5, pp. 1240-1250, May 2010.
    • (2010) IEEE Trans. Power Electron. , vol.25 , Issue.5 , pp. 1240-1250
    • Suul, J.A.1    Molinas, M.2    Undeland, T.3
  • 208
    • 56449087301 scopus 로고    scopus 로고
    • Gamesa DAC converter: The way for REE grid code certification
    • I. Martinez and D. Navarro, "Gamesa DAC converter: The way for REE grid code certification," in Proc. 13th EPE-PEMC, 2008, pp. 437-443.
    • (2008) Proc. 13th EPE-PEMC , pp. 437-443
    • Martinez, I.1    Navarro, D.2
  • 209
    • 59649114419 scopus 로고    scopus 로고
    • Real-time implementation of a STATCOM on a wind farm equipped with doubly fed induction generators
    • Jan./Feb
    • W. Qiao, G. K. Venayagamoorthy, and R. G. Harley, "Real-time implementation of a STATCOM on a wind farm equipped with doubly fed induction generators," IEEE Trans. Ind. Appl., vol. 45, no. 1, pp. 98- 107, Jan./Feb. 2009.
    • (2009) IEEE Trans. Ind. Appl. , vol.45 , Issue.1 , pp. 98-107
    • Qiao, W.1    Venayagamoorthy, G.K.2    Harley, R.G.3
  • 210
    • 67349139918 scopus 로고    scopus 로고
    • Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming
    • Jun
    • W. Qiao, R. G. Harley, and G. K. Venayagamoorthy, "Coordinated reactive power control of a large wind farm and a STATCOM using heuristic dynamic programming," IEEE Trans. Energy Convers., vol. 24, no. 2, pp. 493-503, Jun. 2009.
    • (2009) IEEE Trans. Energy Convers. , vol.24 , Issue.2 , pp. 493-503
    • Qiao, W.1    Harley, R.G.2    Venayagamoorthy, G.K.3
  • 211
    • 79957449874 scopus 로고    scopus 로고
    • Fault ride-through of a DFIG wind turbine using a dynamic voltage restorer during symmetrical and asymmetrical grid faults
    • Mar
    • C.Wessels, F. Gebhardt, and F.W. Fuchs, "Fault ride-through of a DFIG wind turbine using a dynamic voltage restorer during symmetrical and asymmetrical grid faults," IEEE Trans. Power Electron., vol. 26, no. 3, pp. 807-815, Mar. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.26 , Issue.3 , pp. 807-815
    • Wessels, C.1    Gebhardt, F.2    Fuchs, F.W.3
  • 212
    • 78649561505 scopus 로고    scopus 로고
    • Reactive power control for variable speed wind turbines to low voltage ride through grid code compliance
    • A. Teninge, D. Roye, and S. Bacha, "Reactive power control for variable speed wind turbines to low voltage ride through grid code compliance," in Proc. XIX ICEM, 2010, pp. 1-6.
    • (2010) Proc. XIX ICEM , pp. 1-6
    • Teninge, A.1    Roye, D.2    Bacha, S.3
  • 214
    • 77956056188 scopus 로고    scopus 로고
    • Minimum-threshold crowbar for a fault-ride-through grid-code-compliant DFIG wind turbine
    • Sep
    • G. Pannell, D. J. Atkinson, and B. Zahawi, "Minimum-threshold crowbar for a fault-ride-through grid-code-compliant DFIG wind turbine," IEEE Trans. Energy Convers., vol. 25, no. 3, pp. 750-759, Sep. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.3 , pp. 750-759
    • Pannell, G.1    Atkinson, D.J.2    Zahawi, B.3
  • 215
    • 84861455152 scopus 로고    scopus 로고
    • Enhancing low-voltage ride-through capability and smoothing output power of DFIG with a superconducting fault-current limiter-magnetic energy storage system
    • Jun
    • W. Guo, L. Xiao, and S. Dai, "Enhancing low-voltage ride-through capability and smoothing output power of DFIG with a superconducting fault-current limiter-magnetic energy storage system," IEEE Trans. Energy Convers., vol. 27, no. 2, pp. 277-295, Jun. 2012.
    • (2012) IEEE Trans. Energy Convers. , vol.27 , Issue.2 , pp. 277-295
    • Guo, W.1    Xiao, L.2    Dai, S.3
  • 216
    • 33947653839 scopus 로고    scopus 로고
    • Comparison of fault ride-through strategies for wind turbines with DFIM generators
    • A. Dittrich and A. Stoev, "Comparison of fault ride-through strategies for wind turbines with DFIM generators," in Proc. Eur. Conf. Power Electron. Appl., 2005, p. 8.
    • (2005) Proc. Eur. Conf. Power Electron. Appl. , pp. 8
    • Dittrich, A.1    Stoev, A.2
  • 218
    • 57749096905 scopus 로고    scopus 로고
    • Ride-through control of a doubly fed induction generator under unbalanced voltage sags
    • Dec
    • O. Gomis-Bellmunt, A. Junyent-Ferré, A. Sumper, and J. Bergas-Jané, "Ride-through control of a doubly fed induction generator under unbalanced voltage sags," IEEE Trans. Energy Convers., vol. 23, no. 4, pp. 1036-1045, Dec. 2008.
    • (2008) IEEE Trans. Energy Convers. , vol.23 , Issue.4 , pp. 1036-1045
    • Gomis-Bellmunt, O.1    Junyent-Ferré, A.2    Sumper, A.3    Bergas-Jané, J.4
  • 221
    • 57849165949 scopus 로고    scopus 로고
    • Control of doubly fed induction generator under symmetrical voltage dips
    • J. Lopez, P. Sanchis, E. Gubia, A. Ursua, L. Marroyo, and X. Roboam, "Control of doubly fed induction generator under symmetrical voltage dips," in Proc. IEEE ISIE, 2008, pp. 2456-2462.
    • (2008) Proc. IEEE ISIE , pp. 2456-2462
    • Lopez, J.1    Sanchis, P.2    Gubia, E.3    Ursua, A.4    Marroyo, L.5    Roboam, X.6
  • 222
    • 77956032032 scopus 로고    scopus 로고
    • Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines
    • Sep
    • J. Liang, W. Qiao, and R. G. Harley, "Feed-forward transient current control for low-voltage ride-through enhancement of DFIG wind turbines," IEEE Trans. Energy Convers., vol. 25, no. 3, pp. 836-843, Sep. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.3 , pp. 836-843
    • Liang, J.1    Qiao, W.2    Harley, R.G.3
  • 223
    • 70349616083 scopus 로고    scopus 로고
    • Ride through of wind turbines with doubly fed induction generator under symmetrical voltage dips
    • Oct
    • J. Lopez, E. Gubia, E. Olea, J. Ruiz, and L. Marroyo, "Ride through of wind turbines with doubly fed induction generator under symmetrical voltage dips," IEEE Trans. Ind. Electron., vol. 56, no. 10, pp. 4246-4254, Oct. 2009.
    • (2009) IEEE Trans. Ind. Electron. , vol.56 , Issue.10 , pp. 4246-4254
    • Lopez, J.1    Gubia, E.2    Olea, E.3    Ruiz, J.4    Marroyo, L.5
  • 225
    • 79951957728 scopus 로고    scopus 로고
    • Dynamic modeling and improved control of DFIG under distorted grid voltage conditions
    • Mar
    • J. Hu, H. Nian, H. Xu, and Y. He, "Dynamic modeling and improved control of DFIG under distorted grid voltage conditions," IEEE Trans. Energy Convers., vol. 26, no. 1, pp. 163-175, Mar. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.1 , pp. 163-175
    • Hu, J.1    Nian, H.2    Xu, H.3    He, Y.4
  • 226
    • 80053055155 scopus 로고    scopus 로고
    • Fault ride-through capability enhancement of doubly-fed induction wind generators
    • Sep.
    • M. Mohseni, S. Islam, and M. A. S. Masoum, "Fault ride-through capability enhancement of doubly-fed induction wind generators," IET Renew. Power Gen., vol. 5, no. 5, pp. 368-376, Sep. 2011.
    • (2011) IET Renew. Power Gen. , vol.5 , Issue.5 , pp. 368-376
    • Mohseni, M.1    Islam, S.2    Masoum, M.A.S.3
  • 227
    • 84859060081 scopus 로고    scopus 로고
    • Transient control of DFIG-based wind power plants in compliance with the australian grid code
    • Jun
    • M. Mohseni and S. Islam, "Transient control of DFIG-based wind power plants in compliance with the australian grid code," IEEE Trans. Power Electron., vol. 27, no. 6, pp. 2813-2824, Jun. 2011.
    • (2011) IEEE Trans. Power Electron. , vol.27 , Issue.6 , pp. 2813-2824
    • Mohseni, M.1    Islam, S.2
  • 228
    • 84861461737 scopus 로고    scopus 로고
    • Slidingmode control for DFIG rotor- and grid-side converters under unbalanced and harmonically distorted grid voltage
    • Jun
    • M. I. Martinez, G. Tapia, A. Susperregui, and H. Camblong, "Slidingmode control for DFIG rotor- and grid-side converters under unbalanced and harmonically distorted grid voltage," IEEE Trans. Energy Convers., vol. 27, no. 2, pp. 328-339, Jun. 2012.
    • (2012) IEEE Trans. Energy Convers. , vol.27 , Issue.2 , pp. 328-339
    • Martinez, M.I.1    Tapia, G.2    Susperregui, A.3    Camblong, H.4